Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹38.0 L+₹4.9 L (14.7%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹41.6 L+₹8.5 L (25.7%)Rejected-Finance WZ 199 LAJWANTI GARDEN GALI NO 4 NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹43.1 L+₹10.0 L (30.3%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
16 Oct 2023, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
EXTERNAL PERIODICAL SERVICES, CLEANING AND REPAIR OF SEWAGE LINES AND MANHOLES INCLUDING MISC E/M WORKS INCLUDING DAILY MAINTS COMPLAINTS OF APS (OLD AND) COLONY, SANJAY VIHAR, 1 ARMY HQ SIGNAL REGT, 5 SIGNAL GP, 500 (I) SIGNAL COY, ARJAN VIHAR AND O
2023_MES_619535_1
GE/C-53/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹1 L
Yes
18 Nov 2023
19 Sept 2023
18 Oct 2023
19 Sept 2023
16 Oct 2023
3 Oct 2023
19 Sept 2023 - 3 Oct 2023
Amount
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose or disintegrated soil complete all as specified by Engineer-in-Charge .Note; Most of the Excavation will be done manually and no extra cost will be paid to contractor seperately for manual excavation. If any UG Cables, Pipes are damaged during excavation,entire cost for restoration will be borne by the contractor
All as per item no 1 above but depth exc 1.5 m but not exc 3.00 m complete all as specified by Engineer-in-Charge.
M&L PCC 1 : 4 : 8 type D2 using 40mm graded stone aggregates as in foundation of manholes, drains, posts etc complete all as specified by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1 : 4 including demolition complete all as specified by Engineer-in-Charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 finished even and smooth without using extra cement including water proofing compound complete all as specified by Engineer-in-Charge. Note : Water proofing compound shall be measured separately under appropriate items.
Supply only Integral waterproofing compound complete all as specified by Engineer-in-Charge.
Demolition and breaking up drain pipes of 150mm dia and more (Salt glazed ware, AC or Reinforced concrete) set in cement mortar.
Demolition and breaking up drain pipes of 200mm dia and more (Salt glazed ware, AC or Reinforced concrete) set in cement mortar.
S&F DWCPE(SN4) 150mm diameter sewage pipes including snap fit coupler and rubber ring incl testing ,properly jointing and laying in trenches to a level bed complete all as specified by Engineer-in-Charge .
S&F DWCPE(SN4) 200mm diameter sewage pipes including snap fit coupler and rubber ring incl testing ,properly jointing and laying in trenches to a level bed complete all as specified by Engineer-in-Charge.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose/disintegrated soil or rocks complete all as specified.
Removing excavated material rocks to a distance exc 1.5 kms but n exc 5 km and depositing where directed .
M&L for providing cement concrete coping with plain fair faces incl chamferes, weathering, throating etc type C1, 1:3:6 using 20mm graded aggregate complete all as specified.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1 : 2 : 4 type B1 finished smooth and reforming benching as required for 150 mm or 200 mm dia pipes complete all as specified.
S&F Precast plastic fibre reinforced concrete man hole covers" medium duty " of overall size 1000 mm x 500 mm x 75 to 80 mm factary made complete all as specified and directed .
Cleaning of EWC's, IWC's, bottle traps, Nahani traps, gully traps and floor traps etc and CI/ PVC pipes all types top to bottom including junctions etc, cleaning of sewage line upto GT in the area of Old/New APS, Signal enclave and adjoining area (Md accn and all types of Accn) complete all as specified by Engineer-in-Charge.
Cleaning of GT's in the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn)complete all as specified by Engineer-in-Charge.
Cleaning of manhole depth of upto 1.8 m in the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) and taking out sludge and depositing them to notified area by Municipal corp of delhi for dumping or out side Defence land complete all as specified by Engineer-in-Charge.
Cleaning of Manhole depth exc 1.8 m in the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) including removal of all waste etc obtained during cleaning of sewage line within 500 m range complete all as specified by Engineer-in-Charge.
Cleaning of Sewage line from GT to Ist Manhole in the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) including removal of all waste etc obtained during cleaning of sewage line within 500 m range complete all as specified by Engineer-in-Charge.
Cleaning of sewage line n.exc 10 m in length iin the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) including removal of all waste etc obtained during cleaning of sewage line within 500 m range complete all as specified by Engineer-in-Charge.
Cleaning of Sewage line 0.00mtr to 20.00 m in length in the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) including removal of all waste etc obtained during cleaning of sewage line within 500 m range complete all as specified by Engineer-in-Charge . (Note :- This item will be measured if length exceed from 10.00mtr.)
Cleaning of Sewage line exc 20.00 mtr but not exc 30.00mtr in length in the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) including removal of all waste etc obtained during cleaning of sewage line within 500 m range complete all as directed and as specified. Note :- This item will be measured if length exceed from 20.00mtr.)
Cleaning of Sewage line 0.00mtr to 50.00mtr and exceeding in length in the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) including removal of all waste etc obtained during cleaning of sewage line within 500 m range complete all as specified by Engineer-in-Charge (Note :- This item will be measured if length exceed from 30.00mtr.) Note :- For execution of item srl No 16 to 24 above agency should deploy minimum of 04 Nos of Safaiwala and 01 No supervisior on all days of the month/year during the contract period including Sunday and Holidays so as to complaints are attended promptly within 04 hours so that health and life of troops and their families may not be adversly affected. The Delay in rectification of complaint more than four hours, the penality will be levied @ Rs.100.00 Per complaint.
M & L Machine pressed precast concrete rubber moulded interlocking coloured paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 including demolition of existing flooring/hardstanding/ tiles all as specified and disposing to debries etc complete all as specified by Engineer-in-Charge .
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified by Engineer-in-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified by Engineer-in-Charge.
M & L complete removal of existing treatment and preparation of old plastered surfaces and applying two coats of cement base paint over a coat of anti alkaline primer complete all as specified by Engineer-in-Charge.
S & F in repairs 100 mm dia cast iron (spun pipe) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed in walls/floors/trenches etc complete all as specified by Engineer-in-Charge. Note : For pipes fixed on walls to be suitably clamped using stack clamps to maintain 10 to 15 cm distance from the wall (rates inclusive in this item) of appropriate size @ 2 m apart for height of pipe) and all the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5.
S & F in repairs 75 mm dia cast iron (spun pipe) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed in walls/floors/trenches etc complete all as specified by Engineer-in-Charge. Note : For pipes fixed on walls to be suitably clamped using stack clamps to maintain 10 to 15 cm distance from the wall (rates inclusive in this item) of appropriate size @ 2 m apart for height of pipe) and all the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5
S & F in repairs Cast iron Bends of 100mm dia (any radius), diminishing pieces or tapers (larger bore measured) etc complete all as specified by Engineer-in-Charge. Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5
S & F in repairs cast iron Bends of 75mm dia (any radius), diminishing pieces or tapers (larger bore measured) etc complete all as specified by Engineer-in-Charge. Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5
S&F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repair of PVC (SWR) bends any radius of 110mm bore complete all as specified.
S&F in repair of PVC (SWR) bends any radius of 75mm bore complete all as specified.
Mechanically used high pressure Super Sucker Machine capable of Air lifting of dense sludge like muds, slurry, small stones, debries, grits etc from sewer lines/Manholes thorough vaccum mode and capable of Jetting sewer lines of any dia. The machine shall be used by the contractor as per direction of Engineer-in-Charge as on required basis. Job shall be completed to the entire satisfaction of GE.( For ,Sanjay vihar ,Old / New APS Signal encalve and adjoining area ) Note: Rates quoted cleaned for 08 hrs of super sucker machine. Any work carried out throughout 08 hrs shall be measured as on Job.
M&L for complete removal of existing treatment from external surfaces of wall by mechanised sander of Asian paints truecare wall sander or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible complete all as specified and all as directed by Engineer in charge and two coats of weather proofing exterior emulsion paint as per approved make list in Particular Specification, incl one coat of primer up to 4 story bldg complete all as specified and all as directed. Note:- rate quoted up to G+3 bldg including scaffolding.
M&L for complete removal of existing treatment from external surfaces of wall by mechanised sander of Asian paints truecare wall sander or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible complete all as specified and all as directed by Engineer in charge and one coats of weather proofing exterior emulsion paint as per approved make list in Particular Specification, incl one coat of primer up to 4 story bldg complete all as specified and all as directed. Note:- rate quoted up to G+3 bldg including scaffolding.
M&L for applying of wall care putty on newly/old plastered walls of 2-3mm thick including preparing the surface with even and smooth complete all as specified and directed. Note : Wall putty to be procured from manufactures directly.
M&L for preparation of newly plaster surface of wall / Ceiling surface applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine incl one coat of primer up to 5 storey bldg including scaffolding complete all as specified and all as directed by Engr- in-charge. Note:- Rate quoted up to G+3 bldg including scaffolding. Note for item No 38, 39 & 41 (above all three):- 1. Stage for preparation of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. 3. 10% Amt of item No 38, 39 & 41 will be retained as security as guaranttee of material and application.
M&L for preparation of newly plaster surface of wall / Ceiling applying two coats of cement base paint by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for preparation of newly plaster surface of wall / Ceiling surface applying one coats of Oil bound distemper by spray gun/ spray machine up to 10m height complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for preparation of newly plaster surface of Wall / Ceiling surface applying two coats of white wash by spray gun/ spray machine up to 10m height complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+8 bldg including scaffolding
M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying two coats of cement base paint by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying two coats of Oil bound distemper by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for Preparation of old painted surfaces of wood surfaces of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying two coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding
M&L for Preparation of old painted surfaces of steel of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying two coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks all as specified and directed complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding
M & L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. The size of block shall be of 2 Qtrs on each floor and vary in number of floors. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint all as specified and directed by Engr-in-charge.
Checking electrical points for continuous electric supply system and replacement of unserviceable spares for all electrical fixtures, ceiling/exhaust fans of any size and capacity and carrying out minor repairs, fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge at Arjan Vihar and adjoining area.
Attending to complaint of unsv switch ,socket ,fan regulator and making of light / power point in casing caping upto 2 mtr of length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge at Arjan Vihar and adjoining area.
Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable spares, burnt copper wire connections wherever required and repairing any type of switch, socket, plug top etc complete all as specified and directed. Notes for Item No. 50 to 52 fixtures / fittings shall be paid under relevant item against supply only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician and 01 helper at Arjan Vihar Complaint cell from 0900Hrs to 1700 Hrs from Monday to Sunday. Electrician and helper shall report to complaint cell at 0900 hrs daily and get the job card for carry out the work and same will be retrun to concered JE at 1700 hrs as token of completion of job. In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account. Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours. (g) All ser numbered complaint docket will be provided by contractor and amount of docket included in this. (h) Daily attendance register will be maintained by conserned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Attending to electrical complaint of no light / short circuit in light or power circuit / MCCB tripping or any other emergency nature complaint during night hours (from 09 pm to 05 am). Notes for Item No. 53 (a) fixtures / fittings shall be paid under relevant item against supply only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician at Arjan Vihar Complaint cell from 2100 Hrs to 0500 Hrs from Monday to Sunday . Electrician shall report to complaint cell at 2100 hrs daily . In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account. Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours. (g) Daily attendance register will be maintained by converned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Supply only switch piano flush button type single pole one way 6 Amps all as specified.
Supply only socket piano outlet 6 Amp flush button type all as specified.
Supply only bell push single pole 6 Amps all as specified.
Supply only switch piano flush button type single pole 16 Amps.
Supply only socket piano outlet, 2 in 1, 3 pin 6 and 16 Amp single pole .
Supply only Ceiling fan regulator electronic step switch type/socket type, suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete.
Supply only switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply only switch Modular type 6 Amps two way 230V AC complete all as specified and directed by Engineer in charge.
Supply only replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
Supply only Modular socket outlet 5 pin 6 Amp socket 2 moduler complete all as specified and directed by Engineer in charge.
Supply only switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply only Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed.
Supply only Modular five stepped type electronic fan regulator 1/2 module 230V AC complete all as specified and directed.
Supply only ceiling rose surface PVC type with three terminals.
Supply only Electric bell Ding-Dong AC 230 Volt etc complete all as specified and directed.
Supply only insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed.
Supply only industrial metal clad plug top, 3 pin, 10amp / 20 amp (ISI marked) as directed.
Supply only industrial metal clad socket 3 pin 10 amp / 20 amp (ISI marked) as directed.
Supply only plug top 16 Amps 3 pin 230- volts
Supply only LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply only LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply only LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base.
Supply only 14W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz
Supply only 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz,
Supply only MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB DP 20 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
Supply only single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB SP 20 Amp complete all as specified and directed.
Supply only PVC Gang box surface type heavy duty suitable for single switch 5 Amps (ISI Marked) .
Supply only Gang box surface type heavy duty suitasble for 15 Amps switch and socket (ISI Marked)
Supply only replacement white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply only replacement of capacitor 2.5 Mfd, 240 V complete all as specified and directed.
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.
supply only hole fastner madeup of MS 4" long with complete nut bolt all as specified.
Supply only heating element of 2 KW any type with nut bolt washer complete all as directed.
Supply only heating element of 1.5 KW any type with nut bolt washer complete all as directed.
Supply only non return valve 15mm dia (ISI Marked) for geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed.
Supply only for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
Supply only thermostat for 25/35/50 ltrs capacity of geysers complete all as directed.
Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 1.5 sqmm with approved colour code completed all as specified.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 2.5 sqmm with approved coloured code completed all as specified.
Supply only replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
M&L for 15mm thick rendering in CM 1:6 as fair faces of brick walll finished even and fair as directed by Engr-in Charge.
M&L for 5mm thick rendering as concrete surface/ ceiling finished even and fair as directed by Engr-in-Charge.
Schedule of Credit
imran construction company
M/S MSD & Associate
POONAM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .