Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.2 L+₹1.7 L (6.31%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹28.2 L+₹1.7 L (6.45%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹30.8 L+₹4.3 L (16.1%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faridkot
GE Faridkot Military Station
Spl repair to Bldg No T-31 (MES IB) under AGE B/R (M) at Faridkot Mil Stn
2023_MES_584751_1
GE FRD-74/2022-23
Open Tender
Civil Works
Item Rate
240 days
GE Faridkot
Class D Category a i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹60,000
Yes
25 Apr 2023
7 Mar 2023
5 Apr 2023
7 Mar 2023
3 Apr 2023
21 Mar 2023
Amount
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in floors (other than ground floors), beams, staircases, landing, chajjas,shelves and similar suspended work complete all as specified and directed .
Dismantling of brick tiles or terracing tiles single layer on roof & disposal of retrieved material to a distance n.exc 100m from the starting point complete all as specified and specified
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of ) and disposal of retrieved material to a distance n.exc 100m from the starting point complete all as specified and specified
M&L for providing Reinforced cement concrete M-30 (design mix), (using 20mm graded crushed stone aggregates) as in lintels over 1.5 mtr clear span, siesmic band,beams,cantilevers and similar works complete all as specified and directed
M&L for providing Reinforced cement concrete M-30 (design mix), (using 20mm graded crushed stone aggregates) as in slab supported on walls, beams, columns,landings,balconies, canopies,deck slabs and in shelves and other similar works complete all as specified and directed and directed .
M&L for use and waste of form work to sides and soffits of floor or roof beams, beam hunching, girders, lintels, cantlievers, shelves including supports, etc for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for use and waste of form work to soffits of suspended slab such as roof slabs, not exceeding 200mm thick, horizontal or sloping complete all as specified and directed .
M&L for use and waste of formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings, openings in concrete walls, floor and roofs, n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n. exc 20cm wide fair finished surface complete all as specified and directed
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape as required, including cranking, bending and binding with & including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed .
M&L for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape as required, including cranking, bending and binding with & including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed .
M&L for Mild steel TMT bars 5mm dia and over upto 10mm dia,in stirrups,spacers and binders complete all as specified and directed.
M&L for welding in repairs n exc 2.5 cm in length in metal of thickness n. exc 6mm complete all as specified and directed .
M&L for applying one coat of epoxy bonding agent as per manufacturer's specifications complete all as specified and directed Make :- Dr Fixit/Fosroc Nitobond/Sikka Hibond
Dismantling CI pipe/PVC pipe of 75/100mm dia alongwith fittings ,below or above GL/laid in floors/fixed to walls jointed in cement mortar complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches/in floors/fixed to walls including fixing clamps with nut and bolts complete all as specified and directed .
S&F PVC (SWR) bends, any radius ,110mm bore complete all as specified and directed. .
M&L for 75 mm thick cement concrete 1:3:6 type C2( using 40mm graded crushed stone aggregates) as in plinth protection/path finishing surfaces even and fair complete all as specified and directed .
S&F 100mm dia cast iron soil, waste and vent pipe, in any length with or without ears with cement joints, laid in trenches/in floors or fixed to walls complete all as specified and directed .
S&F 75mm dia cast iron soil, waste and vent pipe, in any length with or without ears with cement joints, laid in trenches/in floors or fixed to walls complete all as specified and directed .
S&F CI bends, diminishing pieces or tapers, bore of pipe 100 mm complete all as specified and directed .
S&F CI bends, diminishing pieces or tapers, bore of pipe 75 mm complete all as specified and directed.
S&F in repairs Cast iron floor trap, long neck, 75 mm dia with stainless steel grating including jointing to waste pipe, fixed in cement concrete type B1, 1:2:4 complete all as specified and directed .
Taking up or down 15mm dia GI tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed .
Taking up or down 20mm dia GI tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed
S&F GI tubing,15mm bore, medium grade with all fittings , fixed to wall/ceiling and laid in floors complete all as specified and directed .
All as per item No 25 here-in-before but except tubes
S&F GI tubing,20mm bore, medium grade with all fittings , fixed to wall/ceiling and laid in floors complete all as specified and directed .
All as per item No 27 here-in-before but except tubes
S&F in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity,trippled layered, hoisted and fixed in position including PTMT float valves, high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed in position including all necessary fittings complete all as specified and directed.
S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed .
M&L for Vitrified ceramic tiles, (colour & shade as approved), 8 to 9 mm thick (square/ rectangular), polished,area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick screed in cement mortar 1:6 and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed.
S&F 8 to 9 mm thick ,vitrified ceramic, (colour & shade as approved) tiles of size, n.exceeding 0.36 Sqm as in vertical surfaces such as skirting / dado etc, set and jointed in neat cement slurry over & including 10 mm thick rendering in cement mortar 1:4 and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed .
S&F Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying finishes complete all as specified and directed .
S&F Glazed ceramic coloured tiles 450mmx300mmx7mm thick (colour and shade as approved) as in vertical surfaces such as skirting/dados etc, set and jointed in neat cement slurry & pointed in white cement with pigment to match the colour of tiles over & including 15mm thick rendering in cement mortar 1:4 complete all as specified and directed
S&F Machine cut kota stone slab in flooring 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing,cutting and mirror polishing over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed.
Dismantling of Brickwork or stone/boulder masonry,built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
M&L for brick work with fly ash bricks using old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed .
All as per Srl item No. 38 here-in-before but except bricks.
Dismantling Wall and ceiling boards (fibre,pulp, insulation) or insulation boards/slabs/blankets, any thickness, including cover fillets etc complete all as specified & directed.
S&F anodised aluminium snap grid frame work for false ceiling of grid 605x605mm alongwith hanging wire 2mm thick complete all as specified and directed .
S&F 12mm thick gypsum board as in ceiling fixed with screws as per manufacturer's instructions complete all as specified and directed.
M&L for taking down cement plaster on brick or stone walls/ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed .
M&L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed .
M&L for rendering 5 mm thick in cement mortar 1:3 on ceiling, surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 Cement : 4 Coarse Sand) the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square meter, top layer 15mm cement Plaster 1:1/2:2 (1 Cement : 1/2 Coarse sand : 2 Stone chipping 10mm nominal size) in panels with grooves all round as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed. Note : Payment for providing grooves shall be made separately)
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge
M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion (white/tinted) after finishing the surfaces with a coat of wall care putty by hand roller complete all as specified and directed .
M&L for complete removal of existing treatment of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of distemper oil emultion (white/tinted) after finishing the surfaces with a coat of wall care putty by hand roller complete all as specified and directed
M&L for preparation of newly plastered or unplastered ceiling surfaces and applying two coats of white wash complete all as specified and directed .
M&L for preparation of newly plastered or unplastered surfaces of wall, soffits / facia of chajja/ roof slab and applying two coats of Acrylic smooth exterior paint over and including one coat of exterior primer, using hand rollar complete all as specified and directed.
M&L for complete removal of existing treatment of old decorated surfaces of walls by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts, treating oil & greasy spots,filling depression to make smooth surfaces with wall care putty and applying two coats of Acrylic smooth exterior paint over and including one coat of exterior primer, using hand rollar complete all as specified and directed.
S&F PVC hollow wall lining interlocking type of 5mm thick plain/coloured /wood grain fitted in to the wall with PVC rawl plug and steel screws including fillets on joints as per manufacturer's instruction etc.complete all as specified and directed. Note:- Quoted rate of the item deemed to be included for taking down and refixing (as per existing) minor electric fittings and fixtures (if any) on the surface of wall
Taking down aluminium chowkats or frames n.exc 1.5 sqm each with shutters (without taking of shutters from the frames) complete all as specified and directed
Taking down chowkats or frames n. exc 1.5 sqm each with shutters (without taking of shutters from the frames) complete all as specified and directed
Taking down shutter of any description exc 1 sqm but n.exc 2sqm each & refixing the shutter in same opening including easing and adjusting complete all as specified and directed
Taking down chowkats or frames n. exc 1.5 sqm each & refixing the same in position complete all as specified and directed
S&F anodised aluminium frame for doors, window, ventilators with one or more rebates including joining cleat for fixing etc complete with powder coating on aluminium (minium thickness of powder coating 50 micron) as per the specification. The top & bottom horizontal members and vertical members adjacent to walls shall be fixed with floor, ceiling, walls and cills where required and fixing with the help of rawl plug and screw or with fixing clip or with expansion hold plate fasteners complete including making arrangement to fix guard bars with PVC sleeves all as specified and directed
S&F anodised aluminium window (glazed and gauzed both),side hung type without sash bars, aluminum section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws,anodised aluminium fitting such as peg stays 150mm long (01 no for each shutter), hinges type B-21, 100mm long (02 Nos) suitable handle (01 No) with powder coating of any colour (thickness of powder coating not less than 50micron) etc complete all as specified and directed.
S&F anodised aluminium door shutters, aluminum section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, suitable handle (02 No in each door) with powder coating of any colour (thickness of powder coating not less than 50micron) etc complete all as specified and directed.
S&F stainless steel wire cloth, 0.40mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples complete all as specified and directed .
M&L for 4 mm thick, plain sheet glass, ordinary quality and glazing with oil putty or with wooden beads (supplied alongwith shutters) in squares n.exc 0.5 sqm each pane complete all as specified and directed .
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames and S&F 4 mm thick, plain sheet glass, ordinary quality and glazing with oil putty or with wooden beads (supplied alongwith shutters) in squares n.exc 0.5 sqm each pane complete all as specified and directed .
S&F Pressed steel frames, made out of mild steel sheet 1.25mm thick of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.complete all as specified and directed.
S&F Pressed steel frames, made out of mild steel sheet 1.25mm thick of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.complete all as specified and directed.
M&L for PCC 1:3:6, type C0 (using 12.5mm graded crushed stone aggregates) as in back filling of steel frames, bed blocks for fixing of hold fasts etc including necessary formwork complete all as specified and directed
M&L for applying one coat of synthetic enamel paint on old painted steel surface of any discription over 10 cm width or girth after prepration of surface complete all as specified and directed
M&L for preparation of old painted wood and wood based surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Fixing only in repair bib tap,fancy type,chromium plated with on/off handle, screwed down, screwed for 15mm bore pipe & fixed complete all as specified and directed .
Fixing only in repair Brass Chromium plated basin mixer for mixing hot & cold water screwed down for 15mm bore iron pipe complete all as specified and directed. .
Fixing only in repair angular stop valve, cast copper alloy,chromium plated, screwed down for high pressure with crutch or butter fly handle, screwed both ends for iron pipe of 15mm bore complete all as specified and directed.
Fixing only in repair stop cock, cast copper alloy, fancy type,chromium plated, concealed type with long shank with crutch or butterfly handle, screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed .
S&F PVC connection, 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
S&F EWC vitreous china, twin action, one piece wash down water closet pan with Soft Close Duroplast Seat Cover coloured complete all as specified and directed
S&F in repair vitreous china counter wash basins, size 470x470mm, white flat back to be fixed on counter/ RCC slab including 32mm waste fittings, waste pipe, chromium plated with long screwed shanks & fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified & directed. Make :- CERA Model No SKU S2030115 or equivalent in makes specified in PS
M&L for 18 to 20mm thick Granite (of approved type and colour) work (table rubbed and polished) as in cooking platforms, stair case landing or steps,jambs,pillars and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with approved shade of granite complete all as specified and directed
M&L for Roof Treatment as specified below and as directed : (a) Cleaning, washing of surface and removing all existing bitumen coatings/ APP membrane completely with intense wire brushing or high speed water jet. Surface should be free from any loose paint, dust or grease. (b) All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, damaged portions and hollow areas must be repaired with polymer modified cement mortars. (c) Applying one coat of PrimeSeal/ Epoxy Primer/ShaliUrethane BTD White diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/ sqm (0.20 kg BTD+0.20 Kg water) (d) Laying polyster reinforced fiber net/50 gsm Geotextile mesh, upto 300 mm on walls. (e) Applying three coat of HydroShield PUD microfibre reinforced UV resistent polyurethane (solid content 68% ) / Damp Proof ultra UV Stable fibre reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers (Solid content 55%)/ SmartCare PU Magnum elastomeric waterproofing coating based on hydrophobic polyurethane (solid content 85%)/Single Component Elastomeric Liquid Membrane ShaliUrethane BTD White/coloured (Elongation 400% ± 50, Solid Contents > 80% & Specific Gravity @ 30 OC 1.5 ± 0.03) @ total 2.00 Kg per sqm in two coats for maintaining thickness of 1.5mm, with paint brush/ roller upto 300 mm on walls. (f)) Complete treatment to be carried out by authorised applicator of waterproofing manufacturer. Make : Dr. Fixit / Fosroc / BASF / STP/Asian Note : (i) The treatment shall be carried out as per the manufacturers instructions, and as directed by Engineer in Charge. (ii) The plan area of floor shall be considered for payment (iii) WPC shall be measured and paid seperately.
Taking down carefully existing aluminium/copper point wiring for light, fan, socket or power bell complete with fittings such as Switches, sockets, ceiling roses, holders, call bells & making good the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed. Note : Rate for making good shall be deemed to be included in above item rate.
Taking down carefully existing MCCB,MCB,DB TPN/SPN & making good the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed. Note : Rate for making good shall be deemed to be included in above item rate.
Taking down carefully existing submain wiring 2/4 run with earthing cable & making good the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed. Note : Rate for making good shall be deemed to be included in above item rate.
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc in the existing concealed conduit with new provision of 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 2.8mm thick plastic laminate Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated, stranded (Green colour) connected to common earth point dolly for for one light point/fan point/call bell point, 230 volts controlled by one switch complete all as specified and directed .
All as per Ser item No 82 here-in-before but for switch socket combination 5 Amp 5 Pin socket outlet 230 volts on same board with other switches complete all as specified and directed .
All as per Ser item No 82 here-in-before but for switch socket combination 5 Amp 5 Pin socket outlet 230 volts on independent board complete all as specified and directed .
All as per Srl item No. 82 here-in-before for Switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5 Sqmm FRLS PVC unsheathed copper conductor and FRLS cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed
S&F PVC Lamp holder with back plate suitable for batten fittings complete all as specified and directed .
S&F LED bulb 1 x 10 watt Lamp having luminous efficiency warranty 2 years complete all as specified and directed .
S&F complete set of tube light fitting, 1x20 watt LED (4 feet long), 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube, internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Havells Cat Part No LUMILINEBS20WLED865SPCWH/Bajaj Cat Part no 830379 20WCDL/Crompton Cat Part No LDLL20-CDL
S&F complete set of tube light fitting, 1x10 watt LED (2 feet long), 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube, internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Havells Cat Part No LHEXACP7IN1W010/Bajaj Cat Part no BCLSB 10W/Crompton Cat Part No LDLL10-CDL
S&F ceiling rose, three terminals, PVC polycarbonate, isolated body with bakalite 20mm back plate complete all as specified and directed .
S&F Sub main wiring with two runs of single core PVC FRLS sheathed, insulated, copper cable of 10 Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 10 Sqmm for continous earth wire drawn into existing PVC concealed conduit complete all as specified and directed . Note :- Two runs of 10 Sqmm copper cable and one run of 10 sqmm copper wire earth continuty conductor shall be measured as one length)
S&F in replacement Modular switch 1 way 6 amps, one module complete all as specified and directed.
S&F in replacement Modular socket 6A - 2/3 pin combined, 2 module complete all as specified and directed.
S&F in replacement Modular switch 1 way 16 amps, 1 module complete all as specified and directed.
S&F in replacement Modular socket 6A /16A - 2/3 pin combined, 2 module complete all as specified and directed.
S&F in replacement Modular bell push 6 amps, one module complete all as specified and directed.
S&F in replacement Modular fan step regulator,120W, 6 amps, two module complete all as specified and directed.
S&F in repair factory made epoxy polyester powder coated distribution board TP&N ,4 ways (VTPN DB), double door, (IP-42 protection) fabricated from minimum 1.2 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 250 Amps bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with space for provision for 4 pole MCCB as incommer and outgoing MCBs as required at site and conforming to IS: 8623 along with cable end box including making good disturbed surface complete all as specified and directed.NOTE: (a) MCCBs and MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of BoQ.
S&F MCCB, 4 Pole,adjustable type ,415 V, 100 Amps with breaking capacity 16 KA complete all as specified and directed.
S&F Sheet metal enclosure for DBs,SPN, double door, 230 Volts,8 ways with 200 amps rated bus bar complete all as specified and directed .
S&F MCB, SPN, 63 amps, 230V, C Series with breaking capacity 10 KA complete all as specified and directed
S&F MCB SP 5 to 32 Amp, 230 volts, B Curve with breaking capacity 10 KA complete all as specified and directed
S&F in repair 1X10 watt LED retrofit type bulk head fitting luminaries, die cast, aluminium alloy body, heat resistant, prismatic glass cover with specially designed gasket, lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper coductor cable with suitable size of 230 volt,50 HZ complete all as specified and directed.
S&F in repair energy efficient LED Security light fitting of 25W, pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/ roadway luminaire, with driver including electric connection, complete fitting with all accessories and with following specifications complete all as specified and directed :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max15%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with TMT bar 8mm dia both ways @100c/c. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, including taking out existing one complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Excavation in trenches in any type of soil not exceeding 1.5m deep and 1.5m wide, for foundation,laying of cable etc or manholes,piers,shafts etc not exceeding 10 Sqm on plan and getting out complete all as specified and directed.
Returning, filling in,including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed .
Removal of surplus soil to a distance not exceeding. 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed .
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
S&F GI pipe, light grade, 40mm bore, for cable protection, fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid separately.
Taking down and refixing only ceiling fan complete with accessories, any size, connecting up with and including three core copper flexible wire not less than 0.5 mtr for connecting from ceiling rose / connector to ceiling fan complete all as specified and directed.
Taking down and refixing only exhaust fan, complete with accessories, any size, connecting up with and including three core copper flexible wire not less than 0.5 mtr for connecting from ceiling rose / connector to exhaust fan complete all as specified and directed.
Taking down and refixing only geyser, complete with accessories, any size, connecting up with nuts & bolts,inlet and outlet connection with PVC tube for cold water inlet and PVC reinforced tube for hot water outlet and including three core copper flexible wire not less than 0.5 mtr for connecting from incoming to outgoing any size complete all as specified and directed
Taking down split type AC of capacity up to 2 ton complete (indoor and out door unit) and refixing the same complete with accessories all as specified and directed .
Taking down and refixing only mirror light, ceiling light & fancy light complete with accessories, connecting up with and including three core copper flexible wire not less than 0.5 mtr for connecting from ceiling rose /connector to fitting complete all as specified and directed.
Taking down switch, socket, fan regulator, bell push etc alongwith top cover sheet and refixing the same complete complete all as specified and directed .
S&F Socket Residual Current Device (SRCD) with steel enclosure including MCB,SPN 20 Amps,240 V, AC supply & plug top complete all as specified and directed. Havells Cat Part No DHDDCDP025202003 or equivalent in Makes as specified in PS..
Supply, install, testing and commissioining of hi wall split units indoor/outdoor Air conditioner (3 STAR RATING), heating and cooling type complete with cordless remote control unit and with in built air ioniser and plazma filter for better indoor air quality. Electric driven single phase 230 volts, AC, 50HZ, R-32 refrigerent and Digital Inverter twin rotary of capacity 2 Ton, including copper piping of adeuate size and required length as directed duly insulated with suitable insulating material e.g. glass wool, plywood, moulded thermocoal etc complete with steel bracket with necessary fittings for condensing unit and copper cable of suitable size for making electric connections complete all as specified and directed. Note:-Bidder has to furnish a replacement warranty of 05 years for AC from the date of completion of CA
S&F voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 volt with accurcy of + 2.5% and of capacity 5 KVA with wall mounting bracket complete all as specified and directed
S&F in replacement LED bollard 10 Watt, IP 65 rated with all fittings laid in ground with PCC 1:2:4 type B-1 block of size 60cmx60cmx60cm including making connection with wire of requisite size, 01meter long complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600mm, 35/36 watt, 220 V,AC, Recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed with following specification :- (a) Lumen efficiency of luminaire should be more than 100 Lumen per watt. (b) Voltage operating range : 140 to 270 volts. (c) Temp operating range : Minus 10º C to Plus 50º C. (d) Power factor : Minimum 0.95. (e) THD : Max 10%. (f) IP rating : IP20.(g) CRCA pre coated housing. (h) LED driver of the make as of the luminaire,(j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Inbuilt Surge protection device for 4 KV.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 6 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, including taking out existing one complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
S&F Rigid non metallic PVC conduit 25mm bore exclusive of boxes(junction/terminal) but inclusive of all tees,bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe kooks etc complete all as specified and directed . Note :- A Sum of Rs.90,279.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 29 (Schedule of credit) of Tender Documents.
NEW AMRITSAR CONSTRUCTION COMPANY
M/S BSS AND SONS
RAJINDRA AIR CONDITINOR FABRICATORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .