| 1.00Providing and fixing of pre-fabricated GI Spiral duct / plenum of the following sheet thickness and suitable sizes as required along with necessary supports down rods, anchor fasteners, hardware, i/c Transportation, shifiting, lifting, handling etc as required. Note :- (1)All ducts are to be installed in the 4th Floor and to be shifted thru staircase only (2) The installation work needs to be carried out in the working switch room and hence utmost care and precaution shall be taken in handling tools, dust and debris during drilling, wall opening etc (3) Proper protecting /covering for Telecom Equipment racks shall be arranged and coordinated with the exchange incharge during execution of the entire work with prior intimation and perrmission of Engineer-in-charge | ||||
| 1.10 | 20 Gauge | 75 | Sqm | 1,31,250 ₹1,54,875 Lowest |
| 1.20 | 22 Gauge | 150 | Sqm | 2,40,000 ₹2,83,200 Lowest |
| 1.30 | 24 Gauge | 20 | Sqm | 28,000 ₹33,040 Lowest |
| 1.40 | Powder coating for above ducts as reqired | 225 | Sqm | 1,06,875 ₹1,26,112.5 Lowest |
| 2.00 | Supply and fixing of Thermal insulation of ducts with Class "O" closed cell, elastomeric, nitrile rubber, dust free, fibre free, and CFC free insulation. Thermal insulation 9 MM Nitrile | 250 | Sqm | 1,12,500 ₹1,32,750 Lowest |
| 3.00 | Supplying and fixing of canvas connection made of fire proof material, with opening for inspection, suitable for the existing 7TR SIDWAL / EMERSON Make HPAC unit upto 0.8 Sqmtr approx with 20 mm wide (24 Guage) metal flange all around at both ends of the canvas connection etc., as required. | 7 | job | 35,000 ₹41,300 Lowest |
| 4.00 | Providing and fixing powder coated supply air grills made of extruded Aluminium construction without volume control dampers in the supply air system as required | 6 | sqmt | 90,000 ₹1,06,200 Lowest |
| 5.00Supply and fixing oval damper made of MS, for the new spiral branch ducts i/c poroper support, fixing hardware, Air leak gasket etc as required | ||||
| 5.10 | 400 x 978 | 6 | Each | 36,000 ₹42,480 Lowest |
Tender Value
₹16.2 L
EMD Value
₹32,330
Closing Date
6 Sept 2025, 6:00 pmClosed
EET
BSNLECII Kellys
NIT for ducting and Misc. works for PAC at 4 th floor Anna Road
2025_BSNL_246296_1
NIT No 39/EE-T/EC-II/CH/2025-26
Open Tender
Electrical Works
Works
30 days
Annaroad BSNL
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL Chennai Telephones
₹32,330
Yes
12 Sept 2025
25 Aug 2025
8 Sept 2025
25 Aug 2025
6 Sept 2025
25 Aug 2025
25 Aug 2025 - 6 Sept 2025
Providing and fixing of pre-fabricated GI Spiral duct / plenum of the following sheet thickness and suitable sizes as required along with necessary supports down rods, anchor fasteners, hardware, i/c Transportation, shifiting, lifting, handling etc as required. Note :- (1)All ducts are to be installed in the 4th Floor and to be shifted thru staircase only (2) The installation work needs to be carried out in the working switch room and hence utmost care and precaution shall be taken in handling tools, dust and debris during drilling, wall opening etc (3) Proper protecting /covering for Telecom Equipment racks shall be arranged and coordinated with the exchange incharge during execution of the entire work with prior intimation and perrmission of Engineer-in-charge
20 Gauge
22 Gauge
24 Gauge
Powder coating for above ducts as reqired
Supply and fixing of Thermal insulation of ducts with Class "O" closed cell, elastomeric, nitrile rubber, dust free, fibre free, and CFC free insulation. Thermal insulation 9 MM Nitrile
Supplying and fixing of canvas connection made of fire proof material, with opening for inspection, suitable for the existing 7TR SIDWAL / EMERSON Make HPAC unit upto 0.8 Sqmtr approx with 20 mm wide (24 Guage) metal flange all around at both ends of the canvas connection etc., as required.
Providing and fixing powder coated supply air grills made of extruded Aluminium construction without volume control dampers in the supply air system as required
Supply and fixing oval damper made of MS, for the new spiral branch ducts i/c poroper support, fixing hardware, Air leak gasket etc as required
Dismantling and Removing of unwanted ducts, MS angle / MS Channel, MS Plat form and Aluminium partitions enabling space for running the new oval ducts in the switch room / existing PAC plant room i/c shifiting the dismantled materials in the same floor as per Instruction of engineer in charge etc as reqd.
Dismantling and shifting of LT Panel from TE HRD 4th Floor old GSM AC plant to ARD ZTE 4 th floor AC plant i/c disconnecting existing cables, shifting the panel to ground floor through steps only and transporting the same, loading and unloading, shifting the same to 4th floor ZTE VAS at TE ARD etc complete as requried. (PANEL SIZE -1650 mm X 1500mm X 300 mm)
ITC of panel as per item 7 at 4th floor of ARD TE i/c grouting, checking the busbar, intrenal wiring, tightening of bolts / connectins, replacing any faulty /wornout wiring, earthing the panel etc as required
Supply and fixing of Ladder type GI Cable Tray of following size i/c cutting drilling bolt nut etc as required
450 mm width
300 mm width
Providing MS frame work/extension to existing frame work/supports/ hangers/cable tray/ piping tray/roofing frame work etc fabricated with the following members i/c cutting, welding, drilling holes, threading the rods, required machine shop work, painting etc as required.
75 mm x 40 mm x 5mm channel
35mm x 35mm x 5mm MS angle
5mm thick ms base plate
Supplying and fixing of one number PVC insulated and PVC sheathed aluminium / copper conductor armoured cable of 1.1 KV grade of following size on wall surface as required.
3 ½ x 50 sqmm Al cable
4.0 X 16 sqmm Al cable
4 X 1.5 sqmm Copper cable
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying and laying 40 mm dia ISI marked PVC pipe with all accessories such as bend, elbow, union, tee, laying on surface of wall for package drain i/c making good the damages etc as required.
Providing minor masonry work such as cutting / breaking of wall and making good the same as reqd.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Dismantling and Removing of 7TR HPAC EMERSON Make AC unit indoor at ZTE AC Plant i/c Electrcal power cable / control cable, refrigerant piping, earth wire, canvas connectiong ,power VCD as required
Shifting of dismantled 7TR HPAC Emerson Make i/c Indoor unit, Power VCD with Motor from same floor ZTE Switch room with skilled man power as required
Installation, testing and commissioning of existing 7 TR precision AC package units including mounting indoor pressure testing, vaccumisation, refrigerant charging, RL32 Compressor oil charging to the required level, replacing the liquid line drier, replacement of faulty ball valves etc as reqd .
Laying of following size recovered refrigerant pipe lines in the existing perforated metallic cable tray i/c cutting, bending, brazing etc as reqd
Hot Gas Line/Liquid Line up to 7/8 Size
Supply and Laying of following size refrigerant pipe lines of size for hot and cold circuits, leak and pressure testing of refrigerant lines, vaccumising, of refrigerant piping arrangement and first charge of refrigerant for the AC system complete as per specification
7/8" Copper Pipe
1 1/8" Copper Pipe
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .