Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-Finance | L1 | Accepted-Finance Ist Lowest bidder | |
| 2 | L2₹10.6 L+₹63,720.50 (6.41%)Accepted-Finance | L2 | Accepted-Finance IInd Lowest bidder | |
| 3 | L3₹10.6 L+₹69,252 (6.96%)Accepted-Finance | L3 | Accepted-Finance III Lowest bidder |
Tender Value
₹9.3 L
EMD Value
₹10,000
Closing Date
8 Apr 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
EDC I Saharanpur
Business Plan work in the area of EDSD Ghunna under EDD I Saharanpur
2024_PVVNL_921083_1
327/W/EDC-I/SRE/2023-24
Open Tender
Electrical Works
Lump-sum
45 days
Saharanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE EDC I SRE
₹10,000
Yes
10 Apr 2024
2 Apr 2024
8 Apr 2024
2 Apr 2024
8 Apr 2024
2 Apr 2024
Amount
Detail of Work
Safely cartage of ST/PCC Pole 8.5/11 Mtr. Long from ESC, SRE to the site of work including loading unloading at both ends. (Dist. up to 25 KM.)
Erection of single support on PCC/ST poles up to 8.5/11 Mtr Long with complete fitting of all accessories of 11 KV Line as per RESPO specification
Safely carriage of Line Material (Except PCC Pole)ESC SRE to site of works through privet vehicle including loading and unloading at both ends. (Distance 0 to 25 K.M.)
Fabrication and Erection of D/P on PCC poles/SP55 8.5/11 Mtr. Long with complete fitting including concreting in block of 450x450x1500mm. in ratio 1:4:8 with cement, sand and brick ballast size 1”x1.5” as per RESPO specification.
Safe cartage of 100 KVA T/F from ESC,SRE to site of work including loading & unloading at both ends. (Dist. Upto 25 km.)
Safe installation of 100 KVA T/F on the D/P with complete fittings including making connections and commissioning.
Safely Carriage of LT ABC cable from ESC SRE to site of work including loading and unloading at both ends.
Laying Lifting stringing & Sagging of ABC Cable size 3x120/3x95 sq.mm. including fixing of all type clamps and connector of all accessories.
Removal of 100 KVA T/F from the existing D/P after opening HT & LT connection and with shifting the T/F from the site to ESC, SRE/JE store with loading & unloading at both ends.
Safe cartage of 250 KVA T/F from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 25 km.)
Construction of plinth for installation of 250 kv T/F of size 1.5x1.5x1.5 mtr made of 9”inch thick wall in all four sides with 6”inch thick RCC top duly filled with sand and plastered 12mm thick in ratio 1:4 with cement and sand on outer surface of brick wall.
Safe installation of 250 KVA T/F on the Plinth with complete fittings including making connections and commissioning.
Wire mesh fencing of 250 KVA T/F size 2.5x2.5x2.5 mt. grouting making frame of MS angle 45x45x6 mm and fixing four no. MS strip size 25x6 mm at equal distance in between the frame and fixing squre mesh 50 mm square in each frame the fencing should cover all side of T/F with providing 1 No. door size 6'x3' with sitakni & Dandala.
Pipe/Water Level Earthing of 250 KVA T/F (1 No body & 1 No. neutral earthing) by boring of 60 Ft deep & fixing of 60 ft. G.I pipe 11/2" Dia (Jindal Class B) and connecting with G.I. Strip of size 40x5 mm and G.I wire at bottom of G.I pipe to the T/F providing of required charcoal & salt in the pipe
Safely removal of Power T/F from the plinth to safe place by private crane.
Construction of plinth for installation of previously removed Power T/F of size 3.4(L)xx4.46(W)x.9(H) including below ground level and RCC of Top floor including laying of Rail Piece of length 6.92 Mtr.
Safely Installation of Power T/F from safe place to Plinth by private crane.
Grouting of stay rods by digging of pits in block 600x600x300 MM & cement concreting in ratio 1:4:8 with cement, sand and brick ballast and nozzling of stay wire 7/10 SWG and fitting the same on the pole including fixing of stay insulator in stay wire.
Fixing of Single phase Distribution Box properly.
Providing of Lug 240 sq.mm.
Laying, lifting, stringing, sagging jump ring & binding of ACSR weasel conductor for HT/LT Line.
Providing of Suspension clamp with I hook
Earthing of pole by Earthing rod.
Laying of LT XLPE cable 1*240 sq. mm as per respo specification.
GYAS PAL CONTRACTOR
M/s Raj Kishor Contractor
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .