Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹31.0 L+₹2.0 L (6.93%)Rejected-Finance | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹32.8 L+₹3.8 L (13.2%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Third lowest amount quoted | |
| 4 | L4₹34.9 L+₹6.0 L (20.6%)Rejected-Finance 1814 NARSING NAGAR RANJHI JABALPUR MP 482005 | JABALPUR | JABALPUR | MADHYA PRADESH | 482005 | L4 | Rejected-Finance Highest amount quoted |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
7 Nov 2022, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
REPAIR AND COMPREHENSIVE MAINTENANC OF ELECT FITTING/FIXTURES INCLUDING INTERNAL WIRING DISTRIBUTION SYSTEM AND SECURITY LIGHT IN RESTRICTED/DOMESTIC AREA OF GCF/VFJ AND REPAIR/MAINT OF COOLING/HEATING APPLIANCES INCLUDING CEILING FANS, GEYSERS, SOLA
2022_MES_554426_1
8489/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Garrison Engineer (East) Jabalpur
D b (i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹84,000
Yes
23 Dec 2022
11 Oct 2022
9 Nov 2022
11 Oct 2022
7 Nov 2022
25 Oct 2022
11 Oct 2022 - 18 Oct 2022
Amount
Taking down carefully ceiling fan/exhaust fan/wall fan of any size/make with cable and all accessoreis remove from site to store for repair/overhaulling complete all as directed.
Preventive maintenance and checking of Ceiling/Exhaust/wall fan /air circulator / table fan / padestal fans of any size / type / make, checking the serviceability of safety pins, clamps, down rods, rubber bushes, nuts, bolts, canopies and electric connections etc, connecting / hanging in original position, reconnecting the electric cables and testing complete all as directed. Note. Items required to be replaced, over hauling & rewinding of fan motor if required will be measured and paid separately including.
Dismantle the Ceiling /Exhaust /wall fan /air circulator / table fan / padestal fans of any size /sweep, cleaning, servicing, greasing the fan motor and reassemble the fan complete all as directed. Note. Items required to be replaced & rewinding of fan motor if required will be measured and paid separately).
Dismantling of ceiling fan 1200 /1400 mm sweep and removing the burnt winding and Material and labour for rewinding the same with supper enamelled copper wire of existing size, gauge and turns including cleaning the slots properly and testing complete all as directed.
Dismantling of exhaust fan/wall mounting fan/padestrial fan of any sweep and removing the burnt winding and Material and labour for rewinding the same with supper enamelled copper wire of existing size, gauge and turns including cleaning the slots properly and testing complete all as directed.
S&F in repair of Ceiling fan with down rod,canopy and all accessories 1200 mm sweep, 230 volts,50 Hz. complete all as directed.
Supply and fixing in replacement of Unserviceable fan blade suitable for ceiling fan of any type / size complete all as directed.
Supply and fixing in repairs down rod suitable for Ceiling fan complete all as directed.
Supply and fixing in replacement of Unserviceable clamps with rubber bush and safty pin for ceilling fan of any size/make as per site requirment complete all as directed.
Supply and fixing in replacement of Unserviceable condenser ISI marked 2.5 mfd complete all as directed.
Supply and fixing in replacement of Unserviceable condenser ISI marked 3.15 mfd complete all as directed.
Supply and fixing in replacement of Unserviceable condenser ISI marked 4 mfd (Suitable for desert/industrial cooler) complete all as directed.
Supply and fixing in replacement of Unserviceable ball bearing suitable for ceilling fan any size complete all as directed.
Supply and fixing in replacement of Unserviceable ball bearing suitable for exhaust fan/wall fan/air circulator /padestal fan of any size complete all as directed.
Supply and fixing electronic fan regulator stepped type suitable for ceiling fans, 110 watts, 230 volts, complete all as directed.
Supply and fixing in replacement of Unserviceable bush suitable for ceiling fan /wall fan / air circulator /padestal fan of existing size complete all as specified and directed.
Comprehensive maint of window type/multi split/plit type air conditioner of capacity 1.5 / 2 ton including taking out, reinstalling after repairing, cleaning, servicing, oiling in moveable parts and charging of refrigrent gas if required including testing, comissioning and quarterly servicing of each Air Conditioner and in between period as an when required machanic will visit for minor repair such as electric connections, replacement of small size of wire, cleaning of filter and complete till completion of work all as specified and as directed. Note:- (a) Cost of refrigrent gas and necessary spare parts shall be paid separately. (b) No extra payment will be made to the contractor for machanic visit.
Servicing, maintenance and repairs to Refrigerator / Deep Freezer of capacity up to 310 Ltrs of any make and model including periodical cleaning to condenser coil and compresser, replacement of defective spares will be measured and paid separately under relevant items as under complete all as specified and directed.
Comprehensive maint of water cooler of any make, any type and any capacity after disconnecting inlet, outlet drain pipe and reinstalling, connecting the same after repairing including taking out, reinstalling after repairing, servicing, cleaning of water tank and charging of refrigrent gas if required including testing, comissioning and quarterly servicing of each Water Cooler and in between period as an when required machanic will visit for minor repair such as electric connections, replacement of small size of wire, cleaning of inner tank and complete till completion of work all as specified and as directed. Note. (a) Cost of refrigrent gas and necessary spare parts shall be paid separately. (b) No extra payment will be made to the contractor for machanic visit.
Supply and fix in repair sealed unit compressor suitable for window type/split type air conditioner of 1.5 ton capacity, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as directed. Note:- Cost of refrigrent gas shall be paid under relavent item.
Supply and fix in repair sealed unit compressor suitable for split type air conditioner of 2 Ton capacity, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as directed. Note. Cost of refrigrent gas shall be paid under relavent item.
Supply and fix in repair sealed unit compressor suitable for Deep freeze, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as directed. Note. Cost of refrigrent gas shall be paid under relavent item.
Supply and fix repair sealed unit compressor suitable for water cooler of 40/80 litres capacity, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as directed. Note. Gas for charging shall be measured and paid under relavent item.
Supply and fix in repair sealed unit compressor suitable for water cooler of 60/120 litres capacity, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as directed. Note : Gas for charging shall be measured and paid under relavent item.
Supply and fix in repair PCB (Printed Control Board) with remote control operation and sensor for window/split/multi split type AC 1.5 / 2 TR capacity complete all as specified and directed.
Supply and fixing in replacement of un-serviceable starting capacitor of 80-100 MFD capacity 220-240 volt including taking down old (starting capacitor for water cooler) complete all as directed.
All as per srl item No. 26 here-in-before but 40 - 60 MFD.
Supply and fixing in replacement of Unserviceable running capacitor 220-240 volt , 50 HZ of 36 MFD capacity including taking down old running capacitor (Suitable for Air conditioner / water cooler) complete all as directed.
All as per srl item No. 28 here-in-before but 25 MFD.
All as per srl item No. 28 here-in-before but 10 - 20 MFD.
All as per srl item No. 28 here-in-before but 6 MFD.
Supply and fixing in replacement of un-serviceable relay suitable for 1.5/2 TON capacity AC of any type and any make complete all as directed.
Supply and fixing in replacement of un-serviceable thermostate suitable for water cooler of any make and any capacity complete all as directed.
Supply and fixing in replacement of un-serviceable Over load protector for water cooler of any type and any make complete all as directed.
Supply and fixing in replacement of un-serviceable thermostate suitable for 1.5/2 TON capacity of air conditioner complete all as directed.
Supply and fixing in replacement of Unserviceable Over load protector for 1.5/2 TON capacity AC, any type and any make complete all as directed.
Supply and fixing in replacement of Unserviceable Filter pad for 1.5/2 TON air conditoner of any type and any make complete all as directed.
Supply and fixing in replacement of Split AC Outdoor unit complete with all accessories including compressor not less than Three star rating of same make and capacity replaced one all per site requirement for 1.5 TON capacity AC, complete all as directed.
Supply and fixing in replacement of inverter Split AC Indoor unit complete with all accessories not less than Three star rating of same make and capacity of replaced one,all per site requirement for 1.5 TON capacity AC, complete all as directed.
Supply and fixing in replacement of water cooler copper condensor coil complete with all accessories, all per site requirement for any capacity / any type water cooler complete all as directed.
Supply and fixing in replacement of Split AC indoor unit copper cooling coil complete with all accessories, all per site requirement for 1.5/2 TON capacity AC, complete all as directed.
Supply and fixing in replacement of Split AC Outdoor unit copper condensor coil complete with all accessories, all per site requirement for 1.5/2 TON capacity AC, complete all as directed.
Supply and fixing in replacement of Unserviceable brass flare nut for joint discharge section of indoor and outdoor unit of 1.5/2 TON air conditoner any type and any make complete all as directed.
Supply and fixing in replacement of Unserviceable front grill for window type 1.5/2 TON capacity air conditoner of any make complete all as directed.
Replacement of rusted outdoor mounting stand set with new one for outdoor unit of Split type AC including nuts, bolts & wahers complete all as directed.
S&F Drain hose pipe for 1.5/2 TON AC complete all as directed.
S&F Swing motor suitable for 1.5/2 TON AC complete all as directed.
S&F coil Sensor and air sensor suitable for 1.5/2 TON AC complete all as directed.
Supply and fixing in replacement of un-serviceable PVC sleeves with taflon tape to copper tubing of split type air conditioner from indoor unit to out door unit complete all directed.
Supply and fixing in replacement of un-serviceable AC drier filter suitable for Any capacity window/split type air conditioner complete all directed.
Supply and fixing in replacement of un-serviceable propeller fan blade suitable for window/split type air conditioner outdoor unit complete all directed.
Supply and fixing in replacement of un-serviceable propeller fan blade suitable for water cooler outdoor unit any type and any capacity complete all as directed.
Supply and fixing in replacement of un-serviceable Chromium plated cock of 15mm dia for water cooler Push type complete all directed.
Supply and fixing in replacement of un-serviceable Chromium plated cock of 15mm dia for water cooler self close type complete all directed.
Supply and charging of gas F-22/R-32/R-134/R-290/R-600A/R-410A (freon) suitable for water cooler/window or split AC any type complete all as directed.
Supply and fixing in replacement of Unserviceable copper tube ( suction /discharge line copper tube ) for Window/ spit A/C any make and any type complete all as directed.
Supply and fixing in replacement of un-serviceable Wire kit for Window type A/C any make and any type complete all as directed.
Supply and fixing in replacement of Float valve for Water cooler of existing size any make and any type complete all as directed .
Supply and fixing in replacement of Door gasket for Water cooler any make and any type complete all as directed .
Supply and fixing in replacement of un-serviceable condensor motor in Air conditioner of capacity 0.087 HP (65 watt ) / 0.08 HP(60 watt ) / 0.120 HP (90 watt), 240 volt, 50HZ (suitable for Air conditioner) & testing complete all as directed. Make :- Blue star / Voltas / LG / Godrej
Supply and fixing in replacement of un-serviceable blower motor in Air conditioner of capacity 0.038 HP (29 watt ) / 0.024 HP (18 watt ) / 0.048 HP (36 watt ), 240 volt, 50HZ (suitable for Air conditioner) & testing complete all as directed.
Supply and fixing in replacement of un-serviceable condensor motor in water cooler of capacity 0.087 HP (65 watt ) / 0.120 HP (90 watt), 240 volt, 50HZ (suitable for water cooler) & testing complete all as directed.
Supply and fix in repair sheet steel enclosure suitable for window type air conditioner of capacity 1.5 Ton complete all as directed.
Supply and fix in repair cooling coil & condensing coil including necessiary brazing etc. work for window type air conditioner of capacity 1.5 Ton complete all as directed.
Supply and fixing in replacement of un-serviceable three core copper flexible wire PVC insulated and PVC sheathed of size 1.5 Sqmmcomplete all as directed .
Supply and fixing in replacement of un-serviceable three core copper flexible wire PVC insulated and PVC sheathed of size 2,5 Sqmm complete all as directed.
Taking down and disconnecting existing voltage stabilizer upto 5KVA and strip opening up, single phase automatic buck and boost type with input voltage not less then 130 volts to 280 volts and output voltage 230 volts, plus or minus 2.5% replacement of unserviceable parts re-assembling complete all as directed.
Re-winding power transformer of stabilizer of capacity 1 KVA to 5 KVA with super enamelled copper winding of same gauge and turns as per existing including all insulating material such as latherite paper, glass sleeves, paper insulation if required, varnishing, drying and testing complete all as directed.
Supply and fix in replacement of unserviceable voltage stabilizer of capacity 3 KVA to 5 KVA of super enamelled copper winding including all aaccessories complete all as directed.
Comprehensive maint of desert cooler/ Industrial cooler of any make,any type Cleaning / overhauling, servicing, greasing of fan motor and other movable parts complete all as directed. Note : Items required to be replaced & rewinding of fan motor /replacement of khas pads / wood wools if required shalll be measured and paid separately.
Dismantling fan motor of desert cooler / Industrial cooler and removing the burnt winding and material and labour for rewinding the same with super enamelled copper wire of any type/ capacity/ size, gauge and turns including cleaning the slots properly and testing testing complete all as directed.
Supply and fixing fan regulator stepped type single plase 230 volt suitable for desert coolers complete all as directed.
Supply and fixing front grill suitable for desert Cooler of any make any type complete all as directed .
Supply and fixing PVC switch board assy for desert coolr incl 5 Amps switch - 02 Nos and indicator lamps complete all as directed .
Supply and fixing in replacement of un-serviceable fan blade suitable for desert cooler any type and any capacity complete all as directed.
Supply and fixing in replacement of un-serviceable khas pads/wood wool pad of required size for desert cooler of any make complete all as directed .
Supply and fix in repair of fan motor with motor holding stand complete suitable for desert cooler of any capacity / type single phase, 230 volt complete all as specified and directed.
Supply and fix repair of shutter made of GI sheet suitable for desert cooler including nesessary clamps for holding, steel frame, wood / wool pads any type any capacity complete all as specified and directed.
Supply and fix repair of GI square type water tank of capacity not less than 100 Ltr suitable for desert cooler/ industrial cooler including panting of botth surfaces of the tank complete all as specified and directed.
Supply and fixing in replacement of un-serviceable bush suitable for desert Cooler/Industrial cooler of existing size complete all as specified and directed.
Supply and fixing in replacement of un-serviceable connecting shaft suitable for desert cooler of any size / any make as per site requirment complete all as directed.
Supply and fixing sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with & including one single pole MCB 20 Amps complete all as directed. Make- Havells/Indio Asian/HPL
Supply and fixing in replacement of unserviseble submersible water lifting pump for desert cooler, 240 volts, 50 Hz, AC, 12 watt, 1.5 Metres max head and output : 800 LPH complete all as directed.
Supply, laying and fixing of GI tubing medium grade 15 mm bore ISI Marked with all necesary fittings laid in tranches fixed to wall, laid under floor complete all as specified and directed.
Maint and repair of solar water heating system (plant) of capacity 200 Ltr, cleaning, servicing of complete system with panel and solar water tube including cleaning of air blockage and minor repair with replacement of parts as and when reqired at site complete all as directed.
Supply only Solar Water Tubes of plants Cap 200 litres,complete all as specified and directed. Make : SUDERSHN
Supply only panel washer for top and bottom of tubes for Solar Water Tubes of plants Cap 200 litres all as specified and directed. Make : SUDERSHN
Supply and fix PVC gray pipe of size 2" for insulation covering to hot water pipe line complete all as directed.
M&L for CPVC hot water pipe 20 mm self socket pipe for connection, conforming to IS 4985 ,with all asseseries such as PVC solvent, bend, elbow, valve, NRV, couplings complete all as specified and directed.
Supply and fix in repair of electric water heater storage type of capacity 25 Ltrs, vertical type, 5 star rated with 2/3 KW heating element and grouting including suitable size of nuts and bolts fixing in the wall with PCC 1:2:4 type B1, using 20 mm graded stone aggregate and making good to disturbed surfaces. PVC connection 15 mm size with PTMT nuts of length 400 mm as inlet for cold water and PVC connection of 15 mm size, spirally reinforced with stainless steel wire inside the pipe for outlet hot water pipe connection with brass nuts at both ends of length 450 mm including necessary electric and water connection complete all as directed. Make - Bajaj/Havells/CG.
Taking down carefully storage type water heaters (Geyser) of any type and make of capacity upto 50 Ltrs, after disconnecting their electrical and water connections. De-scaling the inner container, heating element, base assembly using diluted hydrochloric acid and cleaning thoroughly. Filling the inner container with water and detecting leakage including brazing as required to stop the leakage, if any, reassembling the geysers after replacing the un-serviceable spare parts, filling water and testing the geysers by applying pressure by means of hand/foot operated pump, to ensure leak proof. Refixing geyser in the same original position/location and making the electrical/water supply connections incl testing on completion complete all as specified and directed. Note : Items required to be replaced shall be measured and paid separately under relevent items of the Schedule.
Supply and fixing Geyser Indicating lamp as per sample complete all as specified and directed.
Supply and fixing Thermostat suitable for Geyser 25/35/50 ltr complete all as specified and directed.
Supply and fixing Geyser Element 1000/1500 Watt of any type complete all as specified and directed..
Supply and fixing Geyser connection pipe 12/18'' long with sockets in both end, made of steel complete all as specified and directed.
Taking down carefully old unserviceable electric water heater storage type of capacity 50 Litres with all accesseries complete all as directed
Material and labour for Apparatus plate suitable for 25/35/50 ltr geyser all as per sample complete all as specified and directed.
Supply only with replacement of inner container fabricated copper plate of 1.3 mm thick as per the existing size and suitable for up to 50 Ltrs capacity vertical type geyser of any make as per the existing all specified and directed.
Supply and fixing in repair battery of capacity 12 V, 200 AH tubular battery as per manufacturer recommendation, suitable for inverter and making proper connection all as per directed by Engr-In-Charge. Make - luminous invertelast 200 Ah ILTT25060/Amron/Exide
M&L For repair/Servicing of inverter power circuit of capacity 1 KVA as per manufacturer recommendation suitable for 12 volt battery (including battery maintenance distilled water and battery acid filling ) and making proper connection all as per directed by engineer encharge. Make- Microtek.
Supply and fix in replacement of solar water heater of capacity 200 Ltrs with all accessories (storage tank, solar tubes, washers, storage tank mounting stand ) complete including all GI pipe fittings (Gate valve, NRV etc) and mounting structure suitable for existing 1000 Ltrs water tank all as specified and directed. Make:- Sudarshan/V-Guard.
M&L for mild steel compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases splices etc. build up from two or more beam or channel section or angles with plates, including all lattice bars, stiffeners, gusset plates, etc conforming to Fe-290 ( Grade E-165) complete all as specified and directed.
M&L, repair/maintanance and servicing of RO filter of capacity upto 20 litres per hour, 230V AC supply including replacement of micron pre filters, activated carbon filters, sediment filters, cleaning the housing, servicing UV filters, complete all as directed. Note : RO membrane if required to be replaced shall be measured separately.
S&F in repair membrane of suitable size as per site requirement for water cooler RO plant of capacity upto 20 Ltrs/hr complete all as directed.
S&F in repairHousing of suitable size as per site requirement for water cooler RO plant complete all as directed.
S&F in repair Solenoid valve (S.V) of suitable size as per site requirement for water cooler RO plant,complete all as directed.
S&F in repair FRT of suitable size as per site requirement for water cooler RO plant complete all as directed.
S&F in repair in repair PVC Pipe of suitable size as per site requirement for water cooler RO plant,complete all as directed.
S&F in repair RO Booster pump of suitable capacity as per site requirement for water cooler RO plant complete all as directed. Note : For item Srl No. 103 to 110 cost of service charge for monthly visit of mechanic is included in the coated rate.
S&F in repair RO plant water cooler sensor complete all as per site requirement all as directed.
Taking down carefully unserviceable point wiring including making good to disturbed surfaces, matching with existing complete all as directed. Note - Accessories viz switch, Sockets fittings etc shall be measured separately).
Taking down submain wiring any type and in any size including making good to disturbed surfaces, matching with existing complete all as directed.
Material and labour for point wiring for explosive atmosphere with 1100 volts grade, PVC insulated single core FRLS cable with stranded copper conductor of size 2.5 sqmm drawn through and including ERW rigid stove enamelled steel conduit of size 18/19mm dia with bends, elbows, couplings etc., duly approved by CMRI Dhanbad and as per IS, fixed with PVC FRLS, insulated unsheathed multi stranded copper conductor cable of 2.5 sqmm as an earth wire connected to common earth and earth dolly as per IS specification for one light point controlled by one switch complete all as directed.
Supply and fix in repairs flame proof LED fttings 2 x 18/20 watts, aluminium alloy, LM-6 ,IP-65 protection including provision of two Nos. angle iron on wall suitable size for fixing of FLP fittings and connected to junction box with 2.5 sqmm PVC single copper conductor multi stranded along with flame proof flexible metalic hose conduit all as per manufacturers instructions, duly approved by CMRI Dhanbad complete all as directed. Note: Flame proof flexible hose conduit shall be measured and paid Separately.
Supply and fix in repairs flexible metalic hose conduit from junction box to tube light fittings not less than 500mm long of size M20/3/4" conduit M x M / FM x M / F 500mm duly approved by CMRI Dhanbad complete all as directed. Make :- Sudhir baliga/ FCG power/ Shyam swich gear.
Supply and fix in repairs for sheet metal enclosures for TPN DB's, 415 volts, factory made double door, IP-42 protection and all as per IS-8623, made from sheet metal 4 way 200 amps rated bus bar to be fixed with wall and matching the disturbed surface including all accessories complete all as specified and as directed.
Supply and fix in repairs for sheet metal enclosures for SPN DB's, 240 volts, factory made double door , IP-42 protection and all as per IS-8623, made from sheet metal 8 way 200 amps rated bus bar to be fixed with wall and matching the disturbed surface including all accessories complete all as specified and as directed.
Supply and fix in repairs for sheet metal enclosures for SPN DB's, 240 volts, factory , IP-42 protection and all as per IS-8623, made from sheet metal 6 way 200 amps rated bus bar to be fixed with wall and matching the disturbed surface including all accessories complete all as specified and as directed.
Supply and fix in repairs for sheet metal enclosures for SPN DB's, 240 volts, factory made , IP-42 protection and all as per IS-8623, made from sheet metal 2 way 200 amps rated bus bar to be fixed with wall and matching the disturbed surface including all accessories complete all as specified and as directed.
Supply and fix in repairs MCB SP, 6 to 32 amps, as ordered 'C' series, breaking capacity 10 KA, 'C' curve, 240 volts, 50Hz including necessary incoming and outgoing electric connection complete all as directed.
Supply and fix in repairs MCB SPN, 6 to 32 amps,as ordered 'C' series, breaking capacity 10 KA, 'C' curve, 240 volts, 50 Hz including necessary incoming and outgoing electric connection complete all as directed.
Supply and fix in repairs MCB TPN, 40 to 63 amps as ordered 'C' series, breaking capacity 10 KA, 'C' curve, 415 volts, 50 Hz including necessary incoming and outgoing electric connection complete all as directed.
Supply and fix in repairs LED tube light fitting 22 watts T-8 having lumen output 2200-2400 lumen, connecting cable PVC insulated and PVC sheathed copper flexible cable of size 16/ 0.20 mm and necessary fixing arrangements and matching the surface with existing as required on ground, complete all as directed. Make- Philips/Orient/Bajaj/Havells. Note : (a) LED Chip /Driver and housing shall be of same make. (b) LED lamp/ fittings shall comply with LM79/LM80 test/eye certification/biologically test. (c) Test certificate for the above shall be submitted alongwith warranty certificate.
Supply and fix in repairs high efficiency recessed mounted 36 W LED luminaire light fitting, with 120 lumen/watt output, opal diffuser with all connected accessories, prewired with 3 core flexible wire of size 1.5 sqmm, Size 595 x 595 mm connecting and testing complete all as directed. Make -Philips/Orient/Bajaj/Havells. Note : (a) LED Chip /Driver and housing shall be of same make. (b) LED lamp/ fittings shall comply with LM79/LM80 test/eye certification/biologically test. (c) Test certificate for the above shall be submitted alongwith warranty certificate.
Supply and fix in repairs surface mounted LED fitting to with uniform light distribution of 12 W,230 Volts and proper connection from fitting to existing point all as per required and directed by Engg in charge. Make- Philips/Orient/Bajaj/Havells. Note - (a) LED Chip /Driver and housing shall be of same make. (b) LED lamp/ fittings shall comply with LM79/LM80 test/eye certification/biologically test. (c) Test certificate for the above sahll be submitted alongwith warranty certificate.
Taking down existing light fittings any type/any capacity cleaning completely to remove the dust and other particals including checking of all connection and re-fixing the same in original position including provision of single core flexible wire upto ceiling rose complete all as directed.
Supply and fix in repairs LED street light lights 20 Watts in existing bracket and connecting with cable all as per required and directed by engg in charge. Make- Philips/Orient/Bajaj/Havells. Note - (a) LED Chip /Driver and housing shall be of same make. (b) LED lamp/ fittings shall comply with LM79/LM80 test/eye certification/biologically test. (c) Test certificate for the above sahll be submitted alongwith warranty certificate.
Material and labour in repairs for wiring with two single core 6 sqmm multi stranded copper conductor, FRLS, PVC insulated, unsheathed cable, ISI marked, drawn into ERW Steel conduit including 6 sqmm FRLS, PVC insulated and unsheathed stranded copper conductor as earth wire in surface/recess including taking down unserviceable sub-main wiring of any description and making good to the disturbed surfaces to match the existing surfaces complete all as specified and directed. Note:- Two runs of 6 sqmm copper conductor cable, one run of 6 sqmm copper conductor and one run of steel conduit will be measured as one unit.
Suuply and fix in repairs LED Flood Light flameproof Flatglass type 30W, 230 V, suitabe for gas grp IIA and IIb, Zone 1 and 2 , die casting aluminium housing with heat resistant toughned glass /domeglass/ external reflector IP-65 protection fittings to be fixed in hanging with ceiling/fixing in wall any type and providing some hanging /fixing arrangements for the same all a per required and specified by Engr-in-Charge.
Supply and fix in repairs flame proof rotory switch, LM-6 aluminium body enclosure with threaded cover and switch operated by a shrouded knob, single pole, 16 amps capacity with double entries way suitable for 20mm dia ERW threaded rigid steel conduit duly approved by CMRI Dhanbad complete all as directed.
Supply and fix in repairs flame proof switch, socket and plug combined in LM-6 of capacity 16 amps, 240 volts, single phase (2P+Earth) with suitable entry of steel conduit 25mm dia and conecting up complete all as directed.
Suppy and fix junction boxes FLP 4 way/3 way as per requirement of all flameproof gas category CMRI approved all as per required and directed by Engr-in-Charge.
Supply and fix recessed mounted LED luminaire light fitting, 36/40 watts, dimension 1' x 4', 230 V full glow and glare free light louvers with all connected accessories, prewired with flexible wire of size 1.5 sqmm, connecting and testing complete all as directed. Make- Philips/Orient/Bajaj/Havells . Note- (a) LED Chip /Driver and housing shall be of same make. (b) LED lamp/ fittings shall comply with LM79/LM80 test/eye certification/biologically test. (c) Test certificate for the above shall be submitted alongwith warranty certificate.
Supply and fixing in repairs sheet metal enclosure for DBs when MCBs to be used, VTPN double door suitable for MCCB incomer, 415 Volts with 200A rated busbar complete with following accessories all as per requirement and directed by Engr-in-Charge:- (a) Incomer : MCCB, 160 A P, 25 KA - 1 Nos. (b) Outgoing : (i) MCB, TP 40A, 10KA - 4 Nos. (ii) MCB, SP, (6-32A), 10 KA-12 Nos.
Suuply and fix in repairs LED flameproof Flatglass type 20/30/45W, 230 V, suitabe for gas grp IIA and IIb, Zone 1 and 2, die casting aluminium housing with heat resistant toughned glass /domeglass/external reflector IP-65 protection fittings to be fixed in hanging with ceiling/fixing in wall any type and providing some hanging /fixing arrangements for the same all a per required and specified by Engr-in-Charge.
Supply and fix in repairs FLP DB TPN 4 way, 415 Volts with 200 ams rated bus bar, for gas grp IIA and IIB, Zone 1, 2 die casting aluminium housing with, IP 45 degree protection, suitable for incoming cable upto 70 Sqmm 3.5 core including fixing on wall using suitale fixing arrangements all as specified and directed complete with following accessories :- Incoming: MCB TPN-100 A, 10 KA Outgoing: (a) MCB TP 63 A -1 No., 10 KA (b) MCB TP 32 A -1 No., 10 KA (c) MCB DP 16 A -1 No., 10 KA
Material & labour in repairs for air termination, single pointed, aluminium rod 12 mm dia and 300 mm long including fixing arrangements complete all as specified and as directed.
M&L in repairs for test point terminal block made of gun metal or phosphorus Bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos, 8 mm dia 25 mm long hexagonal head screw and brass bolts, nuts , washers suspended on down end earth conductor on insulator on either ends conected to existing aluminium or GI strip complete all as directed.
S&F in repairs earth continuity conductor or main earth lead of aluminium strip 25 x 3 mm with saddles and fixing screw etc for roof conductorand down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting GI strip of size 32mm x 6mm from earth plate to body of the equipment by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40 mm bore GI light grade pipe for protection of earth lead from earth plate(6 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing all as specified and shown in electrical plate No.3 of MES Schedule Part-I.
Supply and fix in repairs light grade galvanised iron tube 50 mm bore with all fittings and fixed to walls / ceiling or laid in floor, pole or laid in trenches and road crossing fixed with walls / poles complete all as specified and as directed.
S&F in repairs change over switch 200 amps on load type, 4 pole, 415 volts in steel sheet metal enclosure with side handle operation complete all as specified and directed.
Supply and fix in repairs 30 watt LED flood light (white) luminaire with high presure die cast housing with IP 66 protection including necessary fixing arrangement complete all as required and directed..
S&F in repairs Post top lantern fittings with 25 watts led bulb fixed in 40 mm medium class GI pipe and grouted properly including PCC work 1:2:4, type B1 provided with all as directed by engineer-in-charge. Make: Bajaj/Wipro/Havells/CG/Philips
Supply and Fix in repairs driver for LED fitting 2 x 2 of 36/45 watt as per sample available complete all as specified and as directed.
S&F in repairs LED decorative night lamp upto 10 Watts, 230 Volt with complete fitting and fixing arrangement on wall with proper connection complete all as directed.
S&F in repairs/replacement of bell ding dong 230 V, single phase complete all as specified and directed.
Supply anfd fix in repairs digital type tamper proof electronic energy meter 3 phase,4 wire Class-1, 3 x 240 V volts,10-60 amps current rating complete all as directed. Make - HPL
Taking down steel shutter electric motor operated from existing position and reassamble/refix the shutter in original position after replacing, electric motor 230 V, 3 HP control gears braking system, chain pully and servicing movable parts including any other works complete for smooth function of the rolling shutter all as directed.
Supply, lay and testing in repairs XLPE, insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of 6 sqmm, 2 core cross sectional area laid in trenches/ poles/ ducts/ pipes or through sleeves etc, including connecting/ jointing complete all as specified and directed.
Schedule of credit amount of Rs. 95,863.00 to be deducted during AOC
SONAL CONSTRUCTION AND ENGINEERS
Goodluck Enterprises
TRISHLA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .