Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | ₹43.4 L | L1 | Accepted-Finance Admitted |
| 2 | L2₹43.5 L+₹11,678.45 (0.27%)Accepted-Finance 14 10 4TH MAIN 8TH C CROSS SRINIVASA NAGAR BSK 3RD STAGE BENGALURU 560085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹43.5 L+₹11,678.45 (0.27%) | L2 | Accepted-Finance Admitted |
| 3 | L3₹44.8 L+₹1.4 L (3.24%)Accepted-Finance NO 64 5TH C MAIN 7TH CROSS AGROGYAPPA LAYOUT KAMMANAHALLI NEAR RAJ KUMAR PARK BANGALORE 560084 | BENGALURU URBAN | KARNATAKA | 560084 | ₹44.8 L+₹1.4 L (3.24%) | L3 | Accepted-Finance Admitted |
| 4 | L4₹46.2 L+₹2.8 L (6.45%)Accepted-Finance NO 45 5TH CROSS MALLAPPA LAYOUT BABUSAPALYA KALYAN NAGAR BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | ₹46.2 L+₹2.8 L (6.45%) | L4 | Accepted-Finance Admitted |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
26 Oct 2023, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
CERTAIN REPAIR REPLACEMENT TO DOOR, WINDOW, FALSE CEILING, PLINTH, SEEPAGE, ROOF SHEET INCLUDING PLUMBING AND INTERNAL ELECTRIFICATION AT HOSPITAL AREA AND OTM ACCN AT CHAF BANGALORE
2023_MES_620302_1
8153/GE/57
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BANGLAORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE (AF) BANGALORE
₹95,000
30 Nov 2023
23 Sept 2023
30 Oct 2023
23 Sept 2023
26 Oct 2023
11 Oct 2023
25 Sept 2023 - 30 Sept 2023
Amount
Taking down chowkhats or frames not exc 1.5 sqm with shutter(without taking of shutter from the frames) including taking out hold fasts and PCC bed block all as specified and directed by Eng-in-Charge
Taking down chowkhats or frames exc 1.5 sqm but not exc 4 Sqm with shutter(without taking of shutter from the frames) including taking out hold fasts and PCC bed block all as specified and directed by Eng-in-Charge
Taking down shutters of any description n.exc 1 sqm each all as specified and directed by Eng-in-Charge
Taking down shutters of any description exc 1sqm and n exc 2 sqm each all as specified and directed by Eng-in-Charge
Demolition brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc.
Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise speciall as specified and directed.
Dismantling structural steel work of any description and any position including doors, gate but excluding framed trusses all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not balking) removing serviceable tiles to store.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in cement mortar all as specified and as directed.
Dismantling plain or corrugated steel sheeting any guage, thickness including roof covering etc.
M&L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded granite stone aggregate) in hold fasts and similar works all as specified and directed by Eng-in-Charge
S&F Pressed steel frames for doors size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc., complete, as specified and directed
S&F Pressed steel frames for doors size 105 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc., complete, as specified and directed
M&L for PCC 1:3:6 type C-1 (using 20mm graded aggregate) as filled in pressed steel foor frames etc complete all as specified and as directed.
S&F factory made solid PVC door frame (chowkhat) of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS tube supplied and fixed in opening as per specification and drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.for factory made solid PVC moulded door shuters 28 to 30 mm thick (Stiles) with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face with particle board core all as specified and directed.
S&F for 35 mm thick factory made second class hard wood plain framed panelled shutter ( two panel) with lock rail and panel of 9mm B.W.P. commecrcial ply or 12mm veneered particle board with commecrcial veneering on both face. The size of rail and stile as per IS 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 30 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, divided into squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc, size of members of shutters as specified in SSR Part I, section 8, clause 8.24 (a) supplied and fitted to chowkats, complete all as specified and directed.
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, divided into squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc, size of members of shutters as specified in SSR Part I, section 8, clause 8.24 (a) supplied and fitted to chowkats, complete all as specified and directed.
S&F 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides fixed to chowkhats all as specified and directed.
S&F steel window/ventilator with side hung shutter including projecting type hinges with steel handles and steel peg stay and with glazing bars complete with dovetailed or welded all as specified and as directed.
S&F steel window/ventilator with side hung shutter including projecting type hinges with steel handles and steel peg stay and but without glazing bars suitable for fixing of gauze all as specified with dovetailed or weldedall as specified and as directed
S&F for framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors, ladders; framed balusters; walk ways; railings; framework of watertanks and similar work confirming to Fe-290, Gde E-165 all as specified.
S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane, complete all as specified and directed.
S&F alluminium alloy wire cloth, o.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples, complete all as specified and directed.
S&F 100mm butt hinges , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed, type C-21 complete all as specified and directed.
S&F 75 mm butt hinges , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed, type C-21 complete all as specified and directed.
S&F 150 mm long Aluminium handles, cast type, anodised, complete all as specified and directed.
S&F 100 mm long Aluminium handles, cast type, anodised, complete all as specified and directed.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F 100 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, complete all as specified and directed.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square nexc 0.5 sqm in each pane including hacking out old broken glass (any thickness, size ,quality or description), from wooden/ steel frame glazed putty or fixed with beads up to 4 storeies, complete all as specified and directed.
S&F in repairs alluminium alloy wire cloth, o.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples, complete all as specified and directed.
S&F in repairs 100mm butt hinges , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed, type C-21 complete all as specified and directed.
S&F in repairs 75mm butt hinges , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed, type C-21 complete all as specified and directed.
S&F in repairs 150 mm long Aluminium handles, cast type, anodised, complete all as specified and directed.
S&F in repairs 100 mm long Aluminium handles, cast type, anodised, complete all as specified and directed.
S&F in repairs 200 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F in repairs 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F in repairs 100 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F 20 mm dia curtain rods of aluminium annodised powder coated fixed including with fixing brackets,stops, rollers etc brackets, fixed as in repairs, complete all as specifed and directed.
M&L Granite 18 to 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and tabil top for fixing wash basin and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite shade including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes all as specified and as directed by Engr-in-charge.
M&L for providing, cement concrete type B-0 (1:2:4) using 12.5mm graded stone aggregate as in roof kerbs, padding or mud stops, rounded or chamfered on edges all as specified and directed
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry (1:3) complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:3 on roof padding finished even and fair with approved water proofing compound @ 200ml per 50kg of cement or as per manufacturer's instruction all as specified and as directed.(Note : WPC shall be measured and paid separately as supply only under relevent item)
Supply only liquid water proofing compound
M&L for water proofing treatment on horizontal and vertical surfaces with Providing and laying / fixing TPO (Thermoplastic Polyolefin) membraneincl Cleaning the surface and laying of 200GSM Geo textile and cover up with TPO RF 1.2 mm thermoplastic membrane on roof & up to 300 mm of parapets and crumple joint including junction of roof and parapet, welding the seam joints with hot air gun/machine and terminate the corners with extra protection to bear the high wind pressure. The TPO should be thoughroly tightened with the lower structure using mechanical fastening properly to avoid the corners and seam joint failure. Make :Asian paints TPO or equivalent product of M/s Bauchemic/CIPY/SIKA/Pidilite/Dr fixit TO membrane
M&L for PCC 1:5:10 Type E-2 (using 40mm graded aggregate) as in filling in sunken slab complete.
M&L for providing water proofing treatment to sunken floor complete all as per following specification :- providing 20mm thick cement plaster in cement mortar 1:3 in mixed with Pidi Proof LW or Dr Fixit @ 200 ml per 50kg of cement and finished even and smooth surface without using extra cement. Note : WPC shall measured and paid saperately
Application of two coats of pidifin 2k water proof coating i.e proof coat of Pidilite @ approx 1.00 Kg per sqm as per manufactures instructions. Note of item No 51 & 52 (i) The rate includes for preparation of surface treatment and sealing of all joints, cracks, corners and junction of pipes etc and ponding test complete all as specified and directed by Engineer-in-Charge . (ii) PCC filling shall be measured and paid separately. (iii) Water testing of sunken floor shall be carried as per direction of GE & rates quoted by the tenderer shall be deemed inclusive of expdr incurred on testing.
M&L for Non skid ceramic coloured joint free tiles 7to 8mm thick (square/ rectangular), area of each tiles exceeding 0.06 sqm but n exc 0.11 sqm, in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles,laid over and including cement screed bed 15 mm thick in cement mortar (1:6) laying floor finish complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surfaces 350 x250x7/450x350x7 mm thick , set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 10mm thick cement plaster in cm (1:4) all as spd.
M&L for 25 mm th PCC (1:2:4) type B0 using 12.5 mm graded aggregagte as in floor to receive floor finishes etc. all as specified.
M&L for Non skid ceramic coloured joint free tiles 7to 8mm thick (square/ rectangular), area of each tiles exceeding 0.11 sqm but n exc 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles,laid over and including cement screed bed 15 mm thick in cement mortar (1:6) laying floor finish complete all as specified and directed.
Supply and fixing steel water tube medium grade galvanized with all fittings 15mm bore and connections, complete including taking up and down steel tubing all as specified and as directed.
Supply and fixing steel water tube medium grade galvanized with all fittings 20mm bore and connections, complete including taking up and down steel tubing all as specified and as directed.
Supply and fixing steel water tube medium grade galvanized with all fittings 25mm bore and connections, complete including taking up and down steel tubing all as specified and as directed.
S&F in repairs 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed. all as specified and as directed. Note :- Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work
S&F in repairs 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed. all as specified and as directed. Note :- Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work
S&F 500 ltrs capacity potential moulded polyethylene water storage tank (cylindrical or vertical) hoisted and fixed in position including dismantling existing unserviceable any type, any capacity, water tank, complete all as specified and directed.
S&F 1000 ltrs capacity potential moulded polyethylene water storage tank (cylindrical or vertical) hoisted and fixed in position including dismantling existing unserviceable any type, any capacity, water tank, complete all as specified and directed.
S&F in repairs 15 mm bore fancy type bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specifed and directed.
S&F in reparis 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe all as specifed and directed.
S&F in repairs 15 mm bore Stop valves, fancy type, chromium plated, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specifed and directed.
S&F Wash basin vitreous china white flat back of size 550x400mm including brass chromium plated pillar tap 15mm size, cast copper alloy with capstan head, brass chromium plated waste fittings, PVC waste pipe of suitable size, plug and porcelin stopper, CI brackets, cutting for and pinning in ends of brackets or erecting stand including taking down the old unserviceable one, complete all as specified and directed.
S&F 15mm PVC connection 600mm long between ends with PTMT nut and washer, fixed as in repairs, complete all as specified and directed .
S&F PVC flexible pipe(wastepipe) suitable for 32 mm waste coupling, fixed as in repairs, complete all as specified and directed .
Waste pipe (PVC) for urinal, fixed as in repairs, complete all as specified and directed .
S&F in repairs plastic water closet seat , white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device.all as specified and as directed.
S&F in repairs Vitreous China wash down water closet pan (Pedestal Pattern), EWC White with 'P' or 'S' trap, including provision of fixing bolts and connecting upto drain and flushing pipe etc complete all as specified and as directed.
S&F in repairs vitreous china squatt pattern, Orissa Pattern size 580x440mm White,with integral Foot rests and 'P' or 'S' trap, white, including provision of fixing bolts and connecting upto drain and flushing pipe etc. complete.
S&F Vitreous china urinal, bowl type flat back of size 465 x 355 x 265 mm white (minimum), with grating, fulsh pipe and union for discharge pipe, fixed as in repairs, complete all as specifed and directed.
S&F in repair Ball valve high pressure of PTMT with epoxy coated aluminium rod and highdensity plastic ball screwed for 20mm dia iron pipe and fixed (minimum wieght 15mm-142gms/20mm 210gms/25mm 455gms/40mm 690gms.
Taking up or down 15mm bore or down steel tubing and connections, including cleaning and re-fixing the old steel tubing and connections new or old position walls,ceilling,floors etc complete all as specified and directed
Taking up or down 20mm bore or down steel tubing and connections, including cleaning and re-fixing the old steel tubing and connections new or old position walls,ceilling,floors etc complete all as specified and directed
Taking up or down 25mm bore or down steel tubing and connections, including cleaning and re-fixing the old steel tubing and connections new or old position walls,ceilling,floors etc complete all as specified and directed
Disconnecting existing tanks exc 250 & n exc 500 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
Disconnecting existing tanks exc 500 & n exc 1000 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
M&L for Pre-cast cement concrete block masonry with solid blocks, exc 10cm in width and setting in mortar type C1 (1:3:6) set in cement mortar (1:6) all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement all as specified & directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement morter 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5mm thick on concrete surfaces of ceiling in cement morter 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for PCC (1:3:6) type-C1 using (20 mm graded broken stone as in surface channel and drain incl. necessary form work all as specified and as directed.
M&L for extra fair forming fair finished drain or channel 30 cm inner girth in cement concrete,using extra cement, including forms, moulds, mi-tred/stopped ends etc.
M &L for providing cement concrete type B1,1:2:4 (20 mm graded aggregate) as in copings including formwork.
M&L for cement concrete type C-1, 1:3:6 (20mm graded aggregate) 75mm thick as in plinth protection, pavement etc and finished the surface even and fair.
M&L for 100mm thick cement concrete 1:2:4 type B2 (40mm graded aggregate) as in floor finishines & pavings even and smooth without using extra cement laid in alternate panels complete all as specified and directed.
S & F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) as in sub base complete all as specified and directed.
M&L for coloured rubberised chequered cement concrete tiles of size 300mm x 300mm x 25 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:6.
M&L 7.5cm thick (compacted thickness) WBM, with coarse aggregates of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size), spread, rolled and consolidated to gradient and camber required complete all as specified and directed
M&L for 60mm thick coloured rubberised machine pressed interlocking pattern paver block any shape and size conforming to IS 15658-2006 of M-35 Grade laid over and including 50mm thick M sand cushioning layer and grouted with dry sand all as specified and directed by Engineer-in Charge.
S&F rolled sections as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates etc complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based carrugated steel sheet 0.50 mm th of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick as in ridge of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness including cover fillets etc., complete all as specified and directed.
8 to 9 mm thick Pre painted gypsum building boards of size 595 x 595mm PVC laminated at back side of board insulation & acoustic purpose flat in ceiling fixed or laid / including powder coated GI snap grid of size 605mm x 605mm frame work using 36.50 x 23.50 x 1.5mm main Tee, 23.50 x 23.50 x 1.5mm cross Tee and 25x25x1.5mm angles for false ceiling with screws fixed to false ceiling including hangers 4 mm dia G.I (upto 1.5m length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and directed. Note: (The rate inclusive of scaffolding and necessary arrangements)
M &L for preparing new plastered or un plastered surface of walls and applying two coats of Cement base paint on walls a coat of chalk primer complete all as specified and directed.
M &L for preparing old plastered or un plastered surface of walls and applying two coats of Cement base paint on walls complete all as specified and directed.
M&L for preparation of new plasiered surfaces of ceiling and applying two coat of white wash all as specified.
M&L for preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of chalk primer whitening complete all as specified and directed.
M&L for preparation of untreated new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint ( 1st grade quality ) over a coat of red oxide primer complete all as specified and as directed.
M&L for two coats of synthetic enamel paint on NEW WOODEN surfaces over coat of pink primer to new surfaces including preparation of surfaces, over 10cm width or girth.
Removing building materials (any type) to a distance of 30 Km beyond the lead including in the rates, including loading, unloading and stacking at the destination all as specified and as directed. (Note : All debris shall be removed from MoD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Taking down eaves gutters and rain water pipes (any size or pattern ) incl all fittings head, shoes,bends swan-necks , etc incl cleaning and refixing or removed to store (measured overall as fixed along the centre line over fittings and accessories.
S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls complete
S&F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls/floor
S&F 75mm PVC (SWR) bends any radius
S&F 110mm PVC (SWR) bends any radius
S&F 110mm PVC (SWR) vent cowl
S&F 75mm PVC (SWR) vent cowl
S&F PVC (SWR) 75mm dia multi floor trap with grating including jointing with solvent cement etc complete all as specified and as directed
S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement etc complete all as specified and as directed
M & L for taking down ceiling fan ,sealing cable end dismantling blades and removing unserviceable fan and blades to store for repair all as specified and directed
M & L for hanging only ceiling fan and connecting up including provision of cable from ceiling rose /connector to fan all as specified and directed
M & L for rewinding of ceiling fan with super enamel copper wire as per existing size/gauge to achieve the required RPM as per manufacturers design including proper heating varnishing and provision of insulating etc and testing complete all as specified and directed. Ceiling fan of size 1200mm sweep
M & L for taking down exhaust fan ,sealing cable end dismantling blades and removing unserviceable fan and blades to store for repair all as specified and directed
M & L for fixing only exhaust fan and connecting up including provision of cable from ceiling rose /connector to fan all as specified and directed
M & L for rewinding of exhaust fan with super enamel copper wire as per existing size/gauge to achieve the required RPM as per manufacturers design including proper heating varnishing and provision of insulating etc and testing complete all as specified and directed for the following sizes
Exhaust fan of size 300mm to 380mm sweep
Exhaust fan of size 400mm to 450mm sweep
Supply & fixing in repair Heating element 1.5 KW capacity AC 230 V and conforming to IS specifications screw/flange type.
Supply & fixing in repair Heating element 2.0 KW capacity AC 230 V and conforming to IS specifications screw/flange type.
Supply & fixing in repair Thermostat suitable for water heater upto 80 litres capacity.
Supply & fixing in repair PVC connection 15mm size with PTMT nuts of length 450 mm for hot water supply.
Supply & fixing in repair PVC connection 15mm size with PTMT nuts of length 600 mm for cold water supply.
Supply & fixing in repair PVC connection 15mm size with PTMT nuts of length 900 mm for cold water supply.
M&L in repair for earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically ( earth pit not less than 2.25 mtrs deep below ground level ) with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, connected to galvanised eath lead wire 4.00 mm dia by means of bolts, nuts ,check nuts & washers of G I or steel all as shown in electrical plate no 3 SSR part I connected to earthing test point all as specified or indicated including testing on completion.
M & L in repair earth continuity conductor GI wire 4.00 mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed any other indicated situation for direct/loop earthing with proper PVC/Porcelain insulator etc all as specified and directed .
M & L for Repair/Reconditiong of exisitng earth pit by removing damaged Earth PCC chambers and excavate pit soil upto 25% of earth plate/electrode and adding alternate layers of charcoal and salt up to 15cm above the earth plate/electrode and moist the mixture using water , cleaning/replacing of funnel with wire mesh where ever necessary ,testing the earthing after reconditioning that the earth resistance value should not be morethan 1.5 Ohms , making good to distrubed surface and all as specified and directed at site. Note: 1. Deemed including excavation, returning filling and connected items. 2. Salt , charcoal , pit chamber , Testing will be measured and paid seperatly
Supply only pure charcoal granular/aggregate type having Ash content < 5% , stone free for earthing
Supply only iodine free pure common salt crystal ( NaCl) for earthing
M & L for Testing of earth resistance of existing earthing using calibrated 3/4 wire digital Earth resistance tester and recording the earth resistance value in register , obtaining the signature of user and MES executive after verification all as specified and directed by the Engr in charge. Note:- contractor has to provide digital earth resistance tester and should be available all the time during the contract period.
S&F in repair capacitor of cap 2.5 MFD paper type for fans complete all as specified and directed.
Supply and fixing in repair of electronic fan regulator socketed step type upto 100 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm. all as specified and as directed
Supply and fixing in repair LED street light fitting 36 Watt, with pressure die cast aluminum housing and heat resistant complete with driver, Integrated Lenses complete with IP 66 protection complete all as specified and directed. MAKE : CROMPTON, MODEL : FREEDOM NEO, CAT NO : LSTS-36-CDL-M or Equivalent in Havells, Indo asian, standard
Supply and fixing in repairs of 15 Watts, LED Luminaire, Round Recess mounted LED edge lit Slim downlight with die cast aluminium housing white powder coated Make : CG, Model : PEARL ULTIMA, CAT NO: LSCRM-15 CDL or Equivalent in BAJAJ/HAVELLS/ PHILPS/ WIPRO
Supply and fixing in repairs of 12 Watts, LED Luminaire, Round Recess mounted LED edge lit Slim downlight with die cast aluminium housing white powder coated Make : CG, Model : PEARL ULTIMA, CAT NO: LSCRM-12 CDL or Equivalent in BAJAJ/HAVELLS/ PHILPS/ WIPRO
Supply and fixing in repairs of LED Bulbs 7 Watts, BEE star rated energy, efficient Retrofit bulb, Make BAJAJ, Model : LEDZ BULB, 830212 or Equivalent in BAJAJ/HAVELLS/ PHILPS/ WIPRO
Supply and fixing in repairs of LED Bulbs 9 Watts, BEE star rated energy, efficient Retrofit bulb, Make BAJAJ, Model : LEDZ BULB, 830213 or Equivalent in BAJAJ/HAVELLS/ PHILPS/ WIPRO
Supply and fixing in repairs of LED Bulbs 12 Watts, BEE star rated energy, efficient Retrofit bulb, Make BAJAJ, Model : LEDZ BULB, 830066 or Equivalent in BAJAJ/HAVELLS/ PHILPS/ WIPRO
Supply and fixing in repairs of Modular box, Plastic enclosure, unbreakable heavy duty with ISI Power unit with 20 amps SP, MCB & Plug top, Make : ANCHOR ROMA, CAT NO : 98488 or Equivalent in ANCHOR/ HAVELLS/ PHILIPS
Supply and fixing, in repair Piano type switch single pole 5 Amps one way 230 volts all as specified and as directed, MAKE : INDO ASIAN or equivalent in HAVELLS/STANDARD/ BAJAJ
Supply and fixing, in repair bell push 5 amps ,230 volts all as specified and as directed
Supply and fixing, in repair switch socket combination outlet 5 A , 5 pin Flush type all as specified and as directed
Supply and fixing, in repair switch socket combination outlet multipurpose 2 in 1 , 5/15 A Flush type all as specified and as directed
Supply and fixing in repair call bell 230 v single pole fancy type Ding Dong Bell all as specified and as directed
Taking down and connecting the electric meters above 25 Amps from meter board and refixing the same including connecting up and provision of cable all as specified and directed.
Servicing/ overhauling of Electric energy meters of any size/ any capacity including testing of meters for running properly and accuracy including load testing with proper equipments
Supply and Fixing in repair of Modular Switch socket combination 6 pin, 6 amps multi purpose, 3 module complete all as specified and directed
Supply and Fixing in repair of Modular Switch socket combination 5 in 1, 3 pin 5 and 16 amps multi purpose flush type universal, with indicator complete all as specified and directed.
Supply and fixing in repair of Modular switch , 1 Module single pole one way 10 Amps, complete all as specified and directed.
Supply and fixing in repair of Modular switch , 1 Module single pole one way 16 Amps, complete all as specified and directed.
Supply and fixing in repair of Modular socket , 2 Module 6 Amps 240 volts Ac 2/3 pin combined suitable for inserting 2 pin 5 Amps/ 3 pin 5 Amps plug top, complete all as specified and directed.
Supply and fixing in repair of Modular socket , 2 Module 6/16 Amps 240 volts Ac 6 pin combined suitable for inserting 3 pin 6/16 Amps plug top, complete all as specified and directed.
Supply and fixing in repair of Modular type fan regulator 120W 2 Module type heavy duty, complete all as specified and directed.
Supply and fixing in repair of switch socket combination outlet, box type 5 A , 5 pin all as specified and as directed Make : ANCHOR, CAT NO. 38841 or Equivalent in Havells, Indo asian, standard
Supply and fixing in repair switch socket combination outlet, box type 6/16 A , 5 pin all as specified and as directed Make : ANCHOR, CAT NO. 14620 or Equivalent in Havells, Indo asian, standard
Supply and fixing in repair LED lights fitting 1x 10 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete all as specified and directed.
Supply and fixing in repair LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete all as specified and directed.
S & F in repair LED light fitting 1 X 10 W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing in repair suspension LED light fitting, 36watt classic styling with cutting edge technology to provide quality illumination and superior optical control, including connecting up with twin core flexible copper conductor cable all as specified and as directed. Make : CROMPTON Model No TREND I, CAT NO : LCPL54-36- CDL or Equivalent in Havells, Indo asian, standard
M & L inreplacement of sub main wiring with Two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 10 sqmm in and including heavy grade PVC casing and capping and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 10 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
All as per serial item No 165 above but for 2x6 sqmmsqmm copper conductor cable 6 sqmm pvc insulated unsheathed copper earth continuity conductor.
All as per serial item No 165 above but for 2x4 sqmm copper conductor cable 4 sqmm pvc insulated unsheathed copper earth continuity conductor.
All as per serial item No 165 above but for 2 x 2.5 sqmm copper conductor cable 2.50 sqmm pvc insulated unsheathed copper earth continuity conductor.
All as per serial item No 165 above but for 2 x 1.5 sqmm copper conductor cable 1.50 sqmm pvc insulated unsheathed copper earth continuity conductor.
M & L in repair for sub main wiring with four single core PVC insulated cable with copper conductor multistranded 1100 volts grade 4.00 sqmm in and including heavy grade PVC casing and capping and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 4.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed.. Note : One run of earth continuity conductor and four run of copper conductor including 3 runS of PVC casing and capping together taken as one length for measuring unit length.
All as per serial item No 170 above but for 4x6 sqmmsqmm copper conductor cable 6 sqmm pvc insulated unsheathed copper earth continuity conductor.
All as per serial item No 170 above but for 4 x 10.00 sqmmsqmm copper conductor cable 10.00 sqmm pvc insulated unsheathed copper earth continuity conductor.
Supply & fixing in repairs sheet metal enclosure MCB DB, Double door type 230v with 4 ways SPN 200 amps bus bar inrepalcement of old unserviceable DB all as specified and directed
Supply & fixing in repairs sheet metal enclosure MCB DB, double door type 230v with 8 ways SPN 200 amps rated bus bar inrepalcement of old unserviceable DB all as specified and directed
Supply & fixing in repairs sheet metal enclosure MCB DB double door type 230v with 12 ways SPN 200 amps bus bar inrepalcement of old unserviceable DB all as specified and directed
Supply & fixing in repairs sheet metal enclosure MCB DB double door type 430 Volts, 4 ways TPN, 200 amps rated bus bar inrepalcement of old unserviceable DB all as specified and directed
Supply & fixing in repairs sheet metal enclosure MCB DB double door type 430 Volts, 6 ways TPN 200 amps bus bar model inrepalcement of old unserviceable DB all as specified and directed
Supply and fix in repairs MCCB 125 Amps fixed thermal fixed magnetic setting, 430 volts, 16KA, 4 pole complete all as specified and directed.
Supply and fix in repairs MCCB 100 Amps fixed thermal fixed magnetic setting, 430 volts, 16KA, 4 pole complete all as specified and directed.
Supply and fix in repairs MCCB 63 Amps fixed thermal fixed magnetic setting, 430 volts, 10KA, 4 pole complete all as specified and directed.
S & F in repairs of old u/s MCB SP of 05 to 32A,'C' curve, 10KA rupturing capacity all as specified and as directed.
S & F in repairs of old u/s MCB SPN of 05 to 32A,'C' curve, 10KA rupturing capacity all as specified and as directed.
S & F in replacement of old u/s MCB SPN of 40 to 63A,'C' curve, 10KA rupturing capacity all as specified and as directed.
S & F in repairs of old u/s MCB TPN of 63A,'C' curve, 10KA rupturing capacity all as specified and as directed.
S & F in repairs of old u/s MCB TPN of 40 A,'C' curve, 10KA rupturing capacity all as specified and as directed.
Supply and fixing in repair of Single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole 20A MCB ,C curve , 10KA with metal clad top as all as directed.
M & L for detecting faults in internal wiring/fittings in OTM/Md accn under AGE E/M CHAFB and rectifiying the defects for restoring supply including replacing of unserviciable defective electrical accessories Note :- (i) Rate for any item shall be measured and paid under respective item of schedule . (ii) Essential material like, insulation tape,screws and all tools required for carrying out the works and instruments to the defect fault shall be deemed to be included in the quoted rate (iii) The work is of day to day maintenace, required Electricians and Helper has to be attend daily for carryout the above work. (iv) All emergency nature complaints must be attended and completed within 2 hrs as and when assigned (v) All other complaints to be attended and completed within 24 hrs as and when assigned (vi) Not rectification of complaints in said time shall be penalized ar Rs 300- per complaint and recovery shall be made in the payment due to the contractor.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Kavitha Constructions
K V RAJANNA
M/S Suresh Raju
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .