| 1 | L2₹72,000Qualified Make: APLAB
Model: Bio Feedback Machine-Medicaid 0 PROP M S MEDICINE AGENCIES GANDHI PARK TOWN HALL GORAKHPUR UTTAR PRADESH 273001 | GORAKHPUR | UTTAR PRADESH | 273001 | Make: APLAB
Model: Bio Feedback Machine-Medicaid | L2 | Qualified | |
| 2 | Qualified Make: APLAB
Model: Bio Feedback Machine-Medicaid 0 PROP M S MEDICINE AGENCIES GANDHI PARK TOWN HALL GORAKHPUR UTTAR PRADESH 273001 | GORAKHPUR | UTTAR PRADESH | 273001 | Make: APLAB
Model: Bio Feedback Machine-Medicaid | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
13 Oct 2018, 5:00 pmClosed
logic analyzer Logic Analyzer ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Number of Channels 34 34 Maximum Clock Rate 235 235.0 Timing (All Channels
All the time) Available * Capacitive Loading 5 * Setup/Hold Time (Adjustable) 1 * Deep Memory Timing for Full Channels 0.5 0.5
1
1.6
2
2.5 Memory Depth with Timestamp for Full channels (upgradeable) 512K 512K Trigger States 16 * Trigger Types Word * Simultaneous state and timing analysis Not available * 1/3 Setup/Hold Violation Not available * Interoperability with Oscilloscope false true
false DISPLAY Display Type TFT * Display Size 10 * GENERIC External Peripheral Interface USB * Number of set of Probes to be Supplied (each passive probe having 17 Channel ) 2 sets * POWER SOURCE Power Requirement 230 V Ac
50 Hz * OPERATING CONDITION Minimum Operating Temperature -5 * Maximum Operating Temperature 35 * Operating Humidity (RH) 75 * OTHER FEATURES Other features
if applicable - * SERVICE Warranty 1 * TEST REPORT DETAILS conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date (not a part of biddable parameter) - * Name and Address of - * 2/3 the Test lab(not a part of biddable parameter) * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajesh Kumar 222002
CMO OFFICE JAUNPUR 1 15
688367
GEM/2018/B/97452
logic analyzer
15 days
Uttar Pradesh; Jaunpur
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| logic analyzer Logic Analyzer ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Number of Channels 34 34 Maximum Clock Rate 235 235.0 Timing (All Channels | - | - | - |
| All the time) Available * Capacitive Loading 5 * Setup/Hold Time (Adjustable) 1 * Deep Memory Timing for Full Channels 0.5 0.5 | - | - | - |
| 1 | - | - | - |
| 1.6 | - | - | - |
| 2 | - | - | - |
| 2.5 Memory Depth with Timestamp for Full channels (upgradeable) 512K 512K Trigger States 16 * Trigger Types Word * Simultaneous state and timing analysis Not available * 1/3 Setup/Hold Violation Not available * Interoperability with Oscilloscope false true | - | - | - |
| false DISPLAY Display Type TFT * Display Size 10 * GENERIC External Peripheral Interface USB * Number of set of Probes to be Supplied (each passive probe having 17 Channel ) 2 sets * POWER SOURCE Power Requirement 230 V Ac | - | - | - |
| 50 Hz * OPERATING CONDITION Minimum Operating Temperature -5 * Maximum Operating Temperature 35 * Operating Humidity (RH) 75 * OTHER FEATURES Other features | - | - | - |
| if applicable - * SERVICE Warranty 1 * TEST REPORT DETAILS conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date (not a part of biddable parameter) - * Name and Address of - * 2/3 the Test lab(not a part of biddable parameter) * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajesh Kumar 222002 | - | - | - |
| CMO OFFICE JAUNPUR 1 15 | - | - | - |
Exempted
13 Oct 2018
3 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_688367.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .