Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹25.0 L+₹2.1 L (9.28%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹25.0 L+₹2.1 L (9.36%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹25.0 L+₹2.2 L (9.64%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹27.7 L+₹4.9 L (21.3%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹81,000
Closing Date
10 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
REPAIR MAINT REPLACEMENT AND IMPROVEMENT WORK OF LT CABLES CABLE JOINTS LT OVERHEAD DISTRIBUTION SYSTEM VARIOUS SERVICE CONNECTIONS AND DISTRIBUTION SYSTEM AND OTHER CONNECTED WORKS IN TECHNICAL AREA AT AF STATION CHAKERI KANPUR
2020_MES_377104_1
8418/E8
Open Tender
Civil Works
Item Rate
335 days
GE (AF) E/M CHAKERI KANPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹81,000
9 Nov 2020
12 Sept 2020
16 Oct 2020
12 Sept 2020
10 Oct 2020
26 Sept 2020
60 days
Amount
Excavation in trenches, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable for soft/ loose soil and getting out complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil complete all as specified and directed.
M & L for dry Ganga Sand cushioning in trenches for protection of cable including watering and consolidation complete all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick sub class B old size laying in trenches for cable protection complete all as specified and directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width & not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material upto 15 cm in depth and 15 cm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate complete all as specified and directed.
M&L for making horizontal boring 60 cm deep below road crossing for passing of LT cable in GI pipe complete all as specified and directed.
Taking out from trenches/duct/floor/wall/roof/under road/drain or hard standing etc. old existing underground XLPE aluminium conductor LT cable for checking the serviceability of cables and making good the disturbed surface to original position complete all as specified and directed for:- Size of cable - 2 to 4 core x 10 sqmm to 16 sqmm
All as per item no. 8 above but of size 3.5/4 core x 25 sqmm to 50 sqmm.
All as per item no. 8 above but of size 3.5 core x 70 sqmm to 120 sqmm.
All as per item no. 8 above but of size 3.5 core x 150 sqmm to 185 sqmm.
All as per item no. 8 above but of size 3.5 core x 240 sqmm to 400 sqmm.
Re-laying only or fixing or passing through pipe, in Pole/duct/trench/under road/hardstanding/wall/roof etc. 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed old serviceable cable after checking of any type of faults (if any) by inspection / using equipment / meggering as required including end termination by providing lugs/thimbles/glands by compression arrangement complete all as specified and directed for :- Size of cable - 2 to 4 core x 10 sqmm to 16 sqmm
All as per item no. 13 above but of size 3.5/4 core x 25 sqmm to 50 sqmm.
All as per item no. 13 above but of size 3.5 core x 70 sqmm to 120 sqmm.
All as per item no. 13 above but of size 3.5 core x 150 sqmm to 185 sqmm.
All as per item no. 13 above but of size 3.5 core x 240 sqmm to 400 sqmm.
Supply Laying, testing and commissioning in repair of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sq mm 2 core laid in trenches/duct / laid on wall etc. incl. suitable size lugs ,thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. complete all as specified and directed. Make :- Havells/Grandlay/Polycab/Finolex/Gloster
All as per item No 18 above but size 16 Sqmm 4 core
All as per item No 18 above but size 25 Sqmm 3.5 core
All as per item No 18 above but size 35 Sqmm 3.5 core
All as per item No 18 above but size 50 Sqmm 3.5 core
All as per item No 18 above but size 70 Sqmm 3.5 core
All as per item No 18 above but size 95 Sqmm 3.5 core
All as per item No 18 above but size 120 Sqmm 3.5 core
All as per item No 18 above but size 150 Sqmm 3.5 core
All as per item No 18 above but size 185 Sqmm 3.5 core
All as per item No 18 above but size 240 Sqmm 3.5 core
All as per item No 18 but size 300-400 Sqmm 3.5 core Note for SL 08 to 29: The cable at various location shall be of varying lengths i.e. in pieces of different lengths as per requirement at site. The quantities of cables shown therein are not necessarily to be laid in one go. The bidder shall quote rates keeping the note into consideration that this being a maintenance contract, he/she is bound to attend the emergent requirement immediately. Suceessful bidder shall abide by the directions issued to him at the earliest for implementing the above items as per directions of Engr-in-Charge.
Supply and laying in trenches/Floor or fixed to Pole/Wall in replacement GI pipe light grade with fitting for protection of cable including dismantling existing pipe complete all as specified and directed.:- Size:- 40 mm bore. Make :- Jindal / Tata / Prakash/ Surya
All as per item No. 30 above but of size 50 mm bore.
All as per item No. 30 above but of size 80 mm bore.
All as per item No. 30 above but of size 100 mm bore.
M&L for detection of fault through fault locating high voltage mobile machine to locate the fault in LT cable by giving high voltage surge and to find out exact location of fault complete all as specified and directed.:- Note : The Item includes transportation, fuel charges, charging of machine etc. for full functioning of machine upto detecting fault at a time. Bidder must quote rate considering the fact that it is solely his responsibility to arrange fault locating machine & he should'nt expect facilitation from the dept. for the same.
M & L for repair of Straight through joint kit Heat shrinkable type suitable for XLPE under ground cable of size 10-16 sqmm 2/4 core complete all as specified and directed:- Make: Raychem / 3M / Denson
All as per item No. 35 above but of size 25-50 sqmm 3.5 core.
All as per item No. 35 above but of size 70-150 sqmm 3.5 core.
All as per item No. 35 above but of size 185-240 sqmm 3.5 core.
All as per item No. 35 above but of size 300-400 sqmm 3.5 core.
Surface dressing 15 cm deep and getting out including cleaning away all grass vegetation saplings, brush wood under grouting, roots & tree and not exceeding 30 cm girth and removing rubbish to a distance of 50 mtr outside the periphery of area complete all as specified and directed.
Dismantling of ACSR conductor of any sizes & length and removing the same from the site complete all as specified and directed.
Dismantling of Earth wire of any sizes & length and removing the same from the site complete all as specified and directed.
Dismantling of insulators of any type, any sizes and at any location complete and removing the same from the site complete all as specified and directed.
Restriging of exisiting ACSR conductor / GI wire of any size / any no. conductor including opening of winding wire of ACSR conductor with insulator and winding with new aluminium winding wire and replacement with new wire complete all as specified and directed.
M & L for Aluminium conductor, steel rainforced (ACSR) of existing size & length as per site requirement complete all as specified and directed.
M & L for Galvanised steel wire 4 mm dia earth wire of existing size & length as per site requirement complete all as specified and directed.
M & L for Pin type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel spindle, two galvanazed iron washer and one galvanazed nut, 100mm height, 65mm dia 1100 Volts grade complete all as specified and directed.
M & L for Shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps 31x3 mm , washers, insulator bolts 12 mm dia, 75 mm height, 90 mm dia & working pressure in 1100 volts complete all as specified and directed.
M & L for erection and repair of stay assembly (wire size 7/4 mm) with stay rod 16 mm dia & insulator loop type with nuts, bolts and washers stay wires size 7/4 mm , Flat iron clamps, Nuts, bolts and washers including necessary excavation, removal of soil, refilling of soil, PCC 1:3:6 work all as per electrical plate No 1 of MES SSR Part-I 2009 complete all as specified and directed.
M & L for repair of PVC Line separator suitable for 02 / 03 nos over conductor with nuts, bolts and washers complete all as specified and directed.
M & L for repair of PVC Line separator suitable for 04 / 05 nos over conductor with nuts, bolts and washers complete all as specified and directed.
S&F in repair of MCCB 250 Amps 36 KA,4 Pole, Ics = 100% Icu adjustable over load setting with thermal magnetic release including lugs,nut,bolts.washers etc and dismantling of old MCCB testing and commissioning complete all as specified and directed. Make:- Schenider Electric / ABB / Legrand
All as per item No. 52 above but MCCB of capacity 160 Amps 36 KA, 4 Pole, Ics = 100% Icu .
Cutting / trimming of tree branches and creepers which are touching of overhead lines / pole and disposal of timber complete without dismantling of ACSR conductor complete all as specified and directed.
Receiving complaints from Complaint Section / JE / Engr-in-charge by any mode of communication & attending the same within 24 hours. This item is inclusive of all the preliminary work like opening of connections, checking for supply, transportation of necessary tools and labour, assessing the nature of complaints, rectifying minor issues including removing carbon deposits (if any), cleaning of lugs/glands etc., meggering of cables, making temporary connections (as required), removing soil, rerouting cables and restoring back the power supply complete all as specified and directed. Note:- The occurance of fault if any, will be communicated to the contractor and the contractor shall rectify the same within 24 hrs of reporting, failing to which a recovery @ Rs 500/= per complaint per day and maximum of Rs. 10,000 /= shall be recovered from contractor's payment. Contractor shall be bound to arrange his resources accordingly and the quoted rates shall be deemed to include the same. Bidder must also appreciate the fact that the work is to be carried out in strategically important locations & hence casual delays are unacceptable. Bidder must also mobilize sufficient manpower in short span of time to meet the work expectations or else penal clauses shall be applicable. All arrangements related to protective equipments for workers & all instrumentation requirements must be arranged by the bidder & shall be in possession of workers at all time. Delay in meeting the same will invoke penal clauses and rate of which shall be deemed to be included in quoted rate.
M & L for repair of End joint kit Heat shrinkable type suitable for XLPE under ground cable of size 70-150 sqmm 3.5 core complete all as specified and directed. Make: Raychem / 3M / Denson
All as per item No. 56 above but of size 185-240 sqmm 3.5 core.
All as per item No. 56 above but of size 300-400 sqmm 3.5 core.
M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed..
BHATIA ENTERPRISES
VEE KAY ENTERPRISES
M/S DARSHAN ENGINEERING WORKS
Bharat Sales Corporation
BRIGHT TRADRES
ashokcontractors
S B ENTERPRISES
M/S ALOK SRIVASTAVA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .