Loading…
Loading…
Tender Value
₹65 L
EMD Value
₹1.2 L
Closing Date
27 Aug 2026, 6:00 pm3d left
CWE (A) Jaisalmer
HQ CWE (A) JAISALMER
MAINTENANCE AND REPAIRS TO VARIOUS 33/11 KV SUBSTATIONS AND OH/UG NETWORK OF MRS STN HQ AT ZONE -II JAISALMER MIL STN UNDER GE (A) JAISALMER
2026_MES_781633_1
84470/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹1,000
GE ARMY JAISALMER
₹1.2 L
Yes
30 Jul 2026
30 Jul 2026
29 Aug 2026
30 Jul 2026
27 Aug 2026
20 Aug 2026
30 Jul 2026 - 6 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Caliberation/Servicing/Overhauling & testing and commissioning of factory manufactured, HT 11 KV Phase 3 wire 50 C/S upto 800 Amps, 18.4 KA or suitable amps single panel switch board, vertical isolation and horizental draw out type vaccum circuit breaker (VCB) confirming to IS-13118, EIC-56 totally enclosed, single busbar floor mounting metal clad indoor extendible fully interlock complete comprising the following :-
(a) CTs primary current injection test .
(b) IR values of CTs
(c) Ratio test of PTs and IR value
(d) Protection relays testing through secondary current injection kit
(e) Voltmeter, ammeter functional tesing
(f) Breaker tesing for tripping time, closing time, contact resistance values and physically healthyness of Vaccum interuptor.
Note:- 1. Wiring of Control Panels of VCBs, wiring of WTI, OTI, CTs, PTs will be including quoted rate.
2. Contractor will be responsible for arranging the expert for checking and rectification/Alteration of control wiring of safety relays through primary and secondary injection kit
3. Relay calibration report shall be submitted to the department. | 14 | Each Job | 99 | ₹1,386 |
| 2 | Taking down and dismounting defective transformer 33/11 KV of capacity 5.0 MVA from foundation by using crane and transporting to workshop or factory (authrorised for such repair) for repair after disconnecting HV, LV side HT cable or HT aluminium conductor, dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting to back from workshop to site, installation on plate form, testing & commissioning to entire satisfaction of Engineer-in-Charge.
Note for item no 2 : Spare parts i.e transformer oil,copper winding wire for rewindig will be measured and paid separately under respective items | 1 | Each Job | 100 | ₹100 |
| 3 | Supply & fix in repair insulator, disc type,porcelain/Polymer series in three with hardware, vitreous,white, brown or green of suitable size socket type, single disc assembly for tension clamp for conductor working pressure 33000 Volt complete all as specified and directed. | 5 | Each | 100 | ₹500 |
| 4 | Supply & fix in repair insulator, pin type,porcelain, vitreous,white, brown or green of suitable size with clamp for conductor working pressure 33000 Volt complete all as specified and directed. | 8 | Each | 100 | ₹800 |
| 5 | Supply & fix in repair disc/suspension insulators for suspension strings on poles of suitable size with clamp for conductor working pressure 33000 Volt complete all as specified and directed. | 4 | Each | 100 | ₹400 |
| 6 | Supply & fix in repair strain insulators at sharp curves,high tension araes on poles of suitable size with clamp for conductor working pressure 33000 Volt complete all as specified and directed. | 5 | Each | 100 | ₹500 |
| 7 | Supply & Fixing in repair lightening arrestors 33 KV, 10 KA station type Class including all clamps, nuts, bolts and washers and connection to earth with 32x6mm GI strip complete and including taking down old unsv LA complete all as specified & directed by Engr-in-Charge. | 1 | Set of Three | 100 | ₹100 |
| 8 | Material and labour in repair for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (9 insulators type & 6 insulators for DO with horizontal operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 400 Amps 33000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately). | 1 | Each Set | 100 | ₹100 |
| 9 | Material and labour in repair for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (9 insulators type & 6 insulators for DO with horizontal operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 400 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately). | 2 | Each Set | 100 | ₹200 |
| 10 | Material and labour in repair for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (9 insulators Vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 400 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately). | 8 | Each Set | 100 | ₹800 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TENDER1.pdf
Tender Documents • 2.60 MB
BOQ_875627.xls
BOQ • 0.31 MB
84470CORRIGENDUM.pdf
PDF • 1.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].