Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.8 LAccepted-AOC 102 AUM PLANET 102 AUM PLANET OPP NIRMALA SCHOOL NIRMALA ROAD NIRMALA ROAD RAJKOT GUJARAT 360007 | RAJKOT | GUJARAT | 360007 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹64.2 L+₹3.4 L (5.56%)Rejected-Finance SCO 40 2ND FLOOR OMAXE WORLD STREET SECTOR 79 FARIDABAD FARIDABAD HARYANA 121004 | FARIDABAD | HARYANA | 121004 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical Hard copy of DD/EMD not recevied and also Not uploaded requisite documents as per NIT. | |
| 4 | Rejected-Technical | - | Rejected-Technical Work experience has not uploaded as per NIT |
Tender Value
₹62.5 L
EMD Value
₹1.2 L
Closing Date
13 Jun 2022, 6:00 pmClosed
CWE (AF) Bamrauli
HQ CWE (AF) Bamrauli 211012
PROVISION OF ROOF TOP SOLAR PANEL 100 KWP CAPACITY AT NORTH CAMP (PHASE - I) AT AF STN BAMRAULI
2022_MES_499898_4
87180/C/E8
Open Tender
Civil Works - Others
Item Rate
182 days
Gorakhpur
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE (AF) Gorakhpur
₹1.2 L
Yes
31 Aug 2022
30 May 2022
20 Jun 2022
30 May 2022
13 Jun 2022
30 May 2022
Amount
Designing, topographic survey, getting the design vetted from any one of the approved agencies, manufacturing, Design, supply, installation, testing and commissioning of Grid connected roof top type Solar Power Plant of 100 KWp Capacity, system panels made with Multi Crystalline Silicon Modules and mounted on Galvanised steel Structure and installed on roof top of RCC framed structure complete all as specified in Particular Specifications and as directed. The rate quoted is deemed to be inclusive of the following :- [a] Grid Interactive Solar Inventor of suitable capacity. [b] AC Distribution board with multi data meter. [c] Temperature and irradiance sensors and contactors, terminals etc. [d] Cables of suitable size complete with terminations up to users LT Panel board end laid in a Engineering practice. [e] Suitable No. of Chemical Earthing including GI Earth Strip. [f] RCC Foundation and Structures for its module mounting as per the design approved. [g] Packing, Forwarding and transportation of all equipment. [h] SCADA System as specified in Particular specification. [j] Isolation transformer as specified in Particular specification. [k] Fire extinguisher, Sand, Bucket as specified in particular specification (l) Lightning arrestor as specified in particular specification. (m) Pyranometer , Temperature sensor, anemometer and wind vane i.e. total weather monitoring station (WMS) as specified in particular specification (n) metering arrangement as specified in particular specification (o) NOC (no objection certificate) from safety department for ongrid system. (p) The rate quoted is deemed to be inclusive of detailed engineering design including feasibility survey for solar power plant using “PV SYS” and “PV SOL” or equivalent software, topographic survey, foundation design etc. and getting the design vetted from “ MNNIT Allahabad/IITs/NITs including Solar Energy Centre/MNRE Approved test centre ”, manufacturing, supplying, erecting, installing, testing and commissioning of grid connected roof top type Solar PV Plant of 100 KWp capacity, being installed on Building as per feasibility study at conditions prevalent at BUILDING NO P-28 (CAC) complete comprising of sub-components, sub-systems and meeting the specifications as given hereinafter and in particular specifications. Note :- (i) All electrical cable /control cable should be properly laid as per Engineering practice ie. on cable tray (cablo foil). (ii) Unit quoted rate shall be deemed to include the cost of cable tray. (iii) The contractor shall carried out structure stability from any IITs/NITs / MNNIT Allahabad before start the work for roof and fixation of where solar module to be mounted on roof top of existing heriatge building within one month from date of commencement of work.
Outsourcing services for comprehensive maintenance, operation and repair of solar power plant at Bldg No. 28 in one shift in a day from 0900 Hrs to 1700 Hrs from Monday to Saturday after complete of project as per conditions of contract including the fwg :- The contractor shall deploy minimum tradesman as follows :- (i) One trained Electrician and one helper in each shifts for attending/monitoring the break down and preventive maintenance. (ii) The electrician must have ITI in electrical and having experience of 02 years in operation & maintenance of solar power plant and familiar with SCADA operating system, weathering monitoring system, HT/LT installation and security and safety features complete. The necessary technical qualification certificate shall be produced for verification of Engr-in-Charge & get the written approval on record before deploying for works. (iii) Contractor shall offer service for entire system as per maintenance schedule as directed by GE in presence of Engineer-in-charge and maintain necessary record for the same. (iv) The electrician must prepare all recording and documentation of Solar Power site records and parameters etc. including cleaning of modules weekly by spraying water with help of and including expandable hose pipe & wipers complete all as specified and directed.
Systemic Electric Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .