Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.8 LAccepted-AOC HOSHIARPUR | HOSHIARPUR | PUNJAB | ₹76.8 L | L1 | Accepted-AOC Responsive |
Tender Value
₹87.0 L
EMD Value
₹1.7 L
Closing Date
10 Feb 2026, 5:00 pmClosed
Executive Engieer
Provl. Divn. PWD B and R Br. Hpur.
Earthwork for Low Level Area Around New Tehsil Building with Public Utilities in Tehsil Complex Hoshiarpur.
2026_CEPW_159186_1
53
Open Tender
Civil Works - Buildings
90 days
Hoshiarpur
Please refer Tender documents.
22 documents required · 22 mandatory
₹5,000
₹1.7 L
13 Apr 2026
3 Feb 2026
11 Feb 2026
3 Feb 2026
10 Feb 2026
3 Feb 2026
Construction of cement concrete kerb with channel with topandbottomwidth115and165 mmrespectively,300mmhighinM20gradekerb channel 300mmwide, 50mmthick inPCCM20 grade, sloped towards thekerb, kerbstonewith channel laidwithkerb layingmachine, foundation concretelaidmanually,allcompleteasperclause 409
Cement concrete 1:4:8
First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density,complete as per MORT&H technical Specifications
Providing, laying, spreading and compacting graded stone aggregate to wet mixmacadam specification includingpremixingtheMaterialwith wateratOMCinmechanicalmixplant, laying in uniform layers with paver in sub- base / base courseonwell preparedsurfaceandcompacting withvibratoryroller toachievethedesireddensity completeasper technicalclause406ofMORT&H specification
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro hydraulic compaction machine and of approved size and design/shape laid in Ordinary Grey and pattern over and including 40 mm thick compactedbedof coarsesand, filling the joints with fine sand etc,all complete as per directions of Engineer-in-Charge for Non traffic Area sand streets having width less than 3.05mt.(Also not to used over footoaths).
Extra cost for using darker fast shade for interlocking paverstiles of any shape & thickness instead of grey colour
Applyingprimingcoatwithcement primer in all shade on newly plastered or concrete exterior surface
Paintingtwoormorecoatsexcludingpriming coatwithsyntheticenamel paint inall shades onwoodwork,metallicorplastered,concrete surface to give an even shade.
Earth fillingunder floorswith surplus soil containingmore than40%takingoutside the premises in 15 cm layers including ramming watering and consolidated lead upto 5000 metres
Rain Harvesting
Earthwork in excavation in foundations trenches etc. in all kinds ofsoil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in15cm, layers with compaction including disposal of all surplus soil asdirected within lead of 30 metres
Cement concrete 1:5:10 with brick ballast 40mm gauge mixingbymechanicalmeansusingconcrete mixer volumetric type
First class burnt brick laid in cement sand mortar 1:4 in foundation and plinth
1st class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4mt above plinth level.
Cement concrete 1:2:4. With stone ballast or shingle
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
12.5 mm thick cement plaster 1:4
Conglomerate floor 40mm thick cement concrete toppi mechanical mixer for mixing of material
S/F spreading & leveling gravels size range Smm to 10mm thick the recharge pitover the existing layers of boulder's in required thickness for the lads & complete as per direction of Engineer-in-charge.
Supplying at quarry site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe)
Boring / drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer — in- charge, upto 90 metre depth below ground level. All types of soil. 300 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore weII,unpIasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010 including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer — incharge. 200mm dia pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc. Complete 300 mm dia. R.C.C. pipe
Providingorangecolour safety footrest of minimum 6mm thick plastic encapsulatedasper IS:10910on12mm dia steel bar confirming to IS: 1786 havingminimuncrosssectionas23mm x 25mmandover all minimum length 263mm and width as 165mm with minimum 112mm space between protrutedlegshaving2mmtreadontop surfacebyribbingorchequeringbesides necessary and adequate anchoring projectionsontail lengthon138mmas per standard drawing and suitable to withstand thebend test andchemical resistance test asper specificationand having manufacturer's permanent identificationmark to be visible even after fixing, includingfixing inmanholes with 230x150x75cm cement concrete block1:2:4(1cement: 2sand: 4stone aggragate) complete as per design.
PUBLIC UTILITY (TIOLET BLOCK)
CONSTRUCTION OF TOILET BLOCK
Earth work in excavation in foundation in all kind of soil not exceeding 2.0m depth.
Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical meansusing concrete mixer volumetric type
First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
CC 1:2:4 (foot basin)
Reinforced cement concrete M-20mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels.
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels. Beam and Lintels @ 8.00 Sqm / cum
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Cold twisted deformed (ribbed/ tor steel) Bars Fe 500 grade as per IS 1786-2008 for R.C.C. works, where not included in the complete rate of R.C.C. including bending, binding, and placing in position complete.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmxwith 35mm wide single rebate
Providing & fixing of Box type steel windows,made of various ERW section outer 60mm x25mm, central mullion 0mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically lashwelded,with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.(b) Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area
Wrought iron and mild steel in window
Wire Guage in window/ vent. Etc
Providing and Fixing MS Angle iron 40x40x6 mm chowkhat including iron hold fasts butt hinges fixed in position ,finished with red lean non setting primer complete in all respect.
Providing and Fixing 14 gauge MS sheet Garage doors with 40mmx40mmx6mm angle iron frame with diagonal braces 3.15 mm gusset plates including locking arrangement eith handles etc.complete in all respects.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:1
P/F 110mm dia UPVC rain water pipe of 4KGF/Sqm etc
P/F 110mm dia UPVC bend for Rain water pipe
P/F 110mm dia UPVC Coupling/ Sockete for Rain water pipe
Cement concrete 1:2:4 gola 10cm x 10cmconcave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
20 mm thick Cement plaster 1:5 internal
12.5mm thick Cement plaster 1:5
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/ Highlighter /emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Conglomerate floor 50mm thc.C.C Toping 1:2:4
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete
Chequerd tiles of any shape size 25mm th.
Wrough tiron mild steel ladder, framed grills, grating etc.
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade. With preparation of plastered surface.
Finishing walls with cement based water soluble exterior paint such as snowcem
Applying priming coat with metal primer on new steel or iron work including preparation of surface
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Public Health Works in Toilet Block to be Constructed in Sports Nursery
Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes to I.S.I. specification (IS:13592) of approved make (to the approval of Engineer-in-charge ) including cutting, jointing, wastage, but excluding cost of lead jointing. S.S.Type B (a) 160mmo/d SWRUPVC pipe lines laid complete
Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes to I.S.I. specification (IS:13592) of approved make (to the approval of Engineer-in-charge ) including cutting, jointing, wastage, but excluding cost of lead jointing. (b) 110mm o/d SWR UPVC pipe lines laid complete
Cement conc. 1:2:4 on pipes
Providing & fixing in position SWR UPVC special for soil waste vent or anti syphonagf pipes i/c cutting, jointing etc. but excluding the cost of lead jointing . For 110 mm o/d pipes . (x) P / Floor Trap 110x75
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. 20 mm i/d
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. 25mm i/d
Providing & fixing & jointing union coupling G.I. 25 mm dia
Providing & fixing & jointing union coupling G.I. 40 mm dia
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. (b) Through wall 22.86 cm thick
Providing and fixing in position Chinaware European type water closet P trap or S trap (to the approval of the Engineer-in-Charge) suite-consisting of 10 ltr. PVC flushing cistern supported on angle iron bracket, short bend 32 mm dia including cost of solid white cover complete in all respect .
Providing and fixing in position vitreous Chinaware white large flat back or angular lipped front urinal 610 mm high of approved make (to the approval of the Engineer-in-charge) (610 mm x 410 mm x 380mm) consisting of C.P. waste 32 mm dia and C.P. brass spreader, complete.
Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm (to the approval of the Engineer-in-Charge) complete in all respect
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Providing and fixing in position vitreous chinaware white lavatory suites consisting of C.P. brass waste 32mm dia, with one C.P. brass pillar tap complete. Size 550mm x 400mm x815mm
Providing & fixing in position C.P. Brass Hexa nipple15mm i/d of approved make .
Providing & fixing in position premium range 15mm i/d bib cock of best quality (as approved by the Engineer-in-charge). (i) C.P.brassBibcocklongnose/ longbody foam flow without flange
Providing & Fixing in position stop cock / Angle valve (as approved by the Engineer-in-charge). (c) C.P. Brass 15mm Angle valve.
Providing & fixing in position best Indian make PVC flexible tube connection. (b) PVC tube connection of size 15mm x 450mm with C.P. brass nut
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. (b) 100mm internal Diametre S W. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, lime concrete with 40 per cent lime mortar 2:3 in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside light duty C.I. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. (a) Size 450 mm x 450 mm inside with RCC 455 mm x 455 mm cover and frame medium duty double seal
Excavation manually in trenches for pipe lines with straight or opencutting instreetsand lanes inbuiltupareawherewidthof street / Lane fromwall towall is less than3meter including trimming and dressing sides levellingofbedsof trenchestocorrectgrade, cutting joint holes, refilling consolidation,watering, including thecost of dewateringof rainwater,diversionfor traffic, night signals. Providing & fixing caution boards,watching, fencing, etc. and removal of surplus soil from thesiteupto15meter distance complete in all respects. Earth work upto 1.5 m. Depth. All classes of soil except rocky
Providing,fixing and jointing ISI Marked Gun Metal peet valves (HeavyPattern)asper IS 778 with hand wheels,onG.I.Pipelines laid in the ground or in side buildings including all carriages complete. 25mm i/d Gun Metal peet valve heavy pattern.
Providing and fixing jet spray with 2'-6" long PVC pipe. (a) With C.P.Brass nut
P/F in position towel rails / ring fixed in with rawl plugs embedded in walls with brass screws, complete in all respects including cutting & making good the walls etc. C.P brass towel ring
Providing&placing inpositiononterrace(atall floor levels) HDPE water storage tanks of approvedmake (totheap provalofEngineer-in charge) with cover with suitable locking arrangement andmaking necessary holes for inlet,outletandover flopipesbutwithout fittings and base support for tank. Triple Layer Tanks
Providing and fixing in position automatic brass ball cock in tanks. (b) Brass ball cock with rod and plastic ball.(ii) 25 mm dia.
Providing & fixing in position C.P. Brass Flange of approved makeunder various fixtures .
Providing and fixing in position S.S. Grating with frame of approved make (to the approval of Engineer-in-charge) complete in all respect .
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. G.I.tank nipple 25mm i/d
Providing & Fixing in position C.P. Brass extension piece 25mm long to100mm longo approved make (to the approval of Engineer-in charge )with various fixtures complete inall respect. C.P.Brassextensionpiece, 25mmlong to 50mm long
Grab bar
Grab bar
CONSTRUCTION OF SEPTIC TANK AND SOAKAGE PIT
Earth work in excavation in foundation and trenches in all kinds of soil. (Ch. No. 6.6 )
Cement concrete 1:8:16 with 40 mm gauge brick ballast. ( Ch. No. 10.6 a )
First class B.B. work laid in cement sand mortar 1:5 ( Ch. No. 11.5 )
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. Ch No. 9.8
R.C.C. work m20 for slab excluding steel reinforcement of concrete centering and shuttering. (Ch. No. 10.15)
Cold twisted for steel ( deformed, ribbed bars.) Ch. No. 18.18
12.5 mm thick cement plaster 1:4
Cement Rendering 1mm thick ch.No. 15.48
50 mm thick C.C. Topping 1:2:4 and Neat floating coat ( Ch. No. 14.7+ 14.4)
Providing and fixing H.C.I.vent pipe. 100mm dia
Providing and fixing inlet and outlet Tee CSR
Providing and fixing Man - hole cover.
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 Ch. No. 29.35
Add for Soakage Pit (29.48 Ch.no)
Electrical Installation
Providing Internal Electrical Installations:
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring fan point (With fan box)
Wiring light point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
G.I. EARTHING:
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling).
Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 14Metre in length) ( Two For Monoblock Pump )
Additional length G.I. wire 7/14 S.W.G. (7/2.18mm dia.) in 20mm dia. G.I. pipe (Flushed)
SUPPLY AND ERECTION OF WIRING ACCESSORIES:
Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,:-
Ceiling Rose (Flush Piano type)
Bakelite Batten Holder (Large size)
MINIATURE CIRCUIT BREAKERS:
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 63amp. (10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:
Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color- coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
SP&N Double Door Distribution Board 8 way each
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-
Overall size 10sq.mm (2Core) Un-armoured (On-Surface)
SINGLE ARM BRACKETS FOR GI PIPE POLE:
Supply and erection of G.I. Pipe (A- Class) Single arm bracket of suitable length to give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the existing surface/ wall with 2nos. MS flat clamp 25mm x 5mm, 30cm long and 4nos. fastner 10mm x 75mm long with two coats of an approved aluminium paint complete in all respect as approved by the Engineer- in-charge at site:-
Single Arm Bracket 1 metre Long G.I. Pipe 40mm Dia.
Supply and erection of Ceiling Fans 1200 mm Sweep (48") having two ball bearing including flexible wire & petty material etc.complete in all respects as appd. and desired by the Engineer in-charge at site.
Supply & Erection of Exhaust FanTransair 300 RPM. With Aluminium louver Shutter And plyboard complete in all respect as appd. And desired by the Engineer in-charge at site.
Supply/erection of LED Batten 40w. High quality aluminium extruded having efficacy of LED fixture mimimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021.. Complete in all respect as appd. And desired by the Engineer in-charge at site.
Supply and erection of LED Street Light 45 watt (including LED driver) with pressure die cast aluminium housing with control gear ( IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021
Dismentling of exiting building
Srtiping and Satcking slate or tiles of a roof
Earthwork excavation in ordinary soil,exclusive of compensation of earth:-Earthwork undressed with a combined lead upto 15 meters including breaking of clods
Dismantling of brick work in cement sand mortar / limemortar including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material.& staking the serviceable material with all lifts& lead of 100 metre (By Mechanical Means)
Removing doors and windows together with the dismentling of walls
Removing doors and windows together with the dismentling of walls
Dismantling of pre-stressed / RCC including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts&leadof 100 mtr (By Mechanical Means
Taking out existing CC interlocking paver blocks from footpath/ central verge/pavement, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in Charge.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge
Tiles from dismentling of brick work
Bricks from dismentling of Brickwork
BRICK/TILES BATS
Old doors complete set as fuel wood
Old windows complete set as fuel wood
Old/Rusted steel from Dismentling of RCC work slab
Taking out existing CC interlocking paver blocks from footpath/ central verge/pavement, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in Charge.
Old aluminium doors complete set
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_322798.pdf
techsummary_322798.pdf
BOQ Comparative Chart
xlsx
finsummary_322798.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.37 MB
SBD53.pdf
Tender Documents • 14.94 MB
BOQ_322798.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid