GE Alwar
GE Alwar
REPAIR/MAINTENANCE OF DB, EARTHING, SECURITY LIGHTS AND CONNECTED WORK IN CITY AREA UNDER GE ALWAR
2023_MES_599823_5
8182/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Alwar
As per NIT
3 documents required · 3 mandatory
₹500
Yes
GE Alwar
₹60,000
Yes
6 May 2024
13 Oct 2023
6 Nov 2023
13 Oct 2023
4 Nov 2023
21 Oct 2023
13 Oct 2023 - 20 Oct 2023
Amount
Taking down carefully copper/Aluminium point wiring for light/fan/socket/power point and taking down of teak wood batten / PVC casing caping/ PVC conduit/steel conduit and making good disturbed surfaces of walls/ceilings /floors etc incl dismentling of fittings.
M&L point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated in existing/New wooden terminal box for mounting fittings like switches, sockets, regulators etc with and including new 3mm thick phenolic laminated sheet top cover, fixed on top of terminal box complete all as specified & directed.
M&L point wiring complete with 1.5 Sqmm single core multistranded copper conductor fire resistant low smoke (FRLSH) PVC insulated and unsheathed cable 1100 Volts grade confirming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20mm external dia) but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling including 1.5 mm FRLSH PVC insulated unsheathed copper earth wire including sunken type pressed steel terminal boxes electro plated of suitable size with bakellite white/ coloured top sheet cover 3.0 mm thick for one light point controlled by one way switch all as specified & directed. Note:- The quoted rates shall be inclusive of cutting, chasing & making good of disturbed surfaces including matching of the existing coloured surfaces of the walls complete & as directed by Engr-in-Charge.
All as per item No 2.00 here-in-before but for one light point controlled two, two way switch.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts.
S&F switch piano fulsh type , single pole, two way 5 Amps 230 Volts.
S&F LED type security-DRACO SERIES light luminaire 20 watt 230 V 50 Hz including all necessary fitting accessories and LED complete all as directed. Make : C&S Cat Part No LTESS20WLED or equvalent Crompton Greaves /Wipro
S&F in repair street light bracket made to shape at required angle made out of 40 mm dia (light grade)/suitable size for fitting of security light GI tubing of length not less than 1.5m long suitable for fixing /holding street light fittings including mild steel flat iron 50 x 6 mm clamp 02 Nos with bolts, nuts and washer complete all as directed.
S&F sheet metal enclosure concealed in wall incl making good of disturbed surfaces double door type suitable for fixing MCB's, TPN 4 way, 415 Volts and including taking down old U/S DB ,TPN,4 way complete all as specified & directed.
S&F sheet metal enclosure concealed in wall incl making good of disturbed surfaces double door type suitable for fixing MCB's, SPN with 200 Amps rated bus bar,8 way, 230 Volts and including taking down old U/S DB ,SPN,8 way complete all as specified & directed.
S&F sheet metal enclosure concealed in wall incl making good of disturbed surfaces double door type suitable for fixing MCB's, SPN with 200 Amps rated bus bar,4 way, 240 Volts and including taking down old U/S DB ,SPN 4 way complete all as specified & directed.
S&F sheet metal enclosure in wall incl making good of disturbed surfaces single door type suitable for fixing MCB's, SPN without busbar 2 way, 230 Volts and including taking down old U/S DB ,SPN 2way complete all a specified & directed.
S&F sheet metal enclosure concealed in wall incl making good of disturbed surfaces double door type suitable for fixing MCB's, TPN 8 way, 415 Volts and including taking down old U/S DB ,TPN,8 way complete all as specified & directed.
S&F MCB 35 to 63 Amps, single pole & neutral, 240 volts.
S&F MCB 5 to 32 Amps, single pole & neutral, 240 Volts.
S&F MCB 6 to 30 amps, single pole, 240 Volts.
S&F MCB 35 to 63 Amps, triple pole & neutral, 415 volts.
S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with 01 No. single pole MCB 20 Amps complete all as specified & directed.
S&F sub main wiring on and including passing through PVC conduit pipe 1100 Volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm and continuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm of green colour confirming to IS 694/1990 including taking down existing U/S sub main wiring. (Note: Two runs of cable with one run of earth wire and one run of PVC Conduit should measured as one length).
S&F 2nd class hard wood rectangular block open recessed of size 45cmx30cmx5cm depth with 3mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawl plug (4 Nos),for DB complete all as specified & directed.
S&F 2nd class hard wood rectangular block open recessed of size 30cmx25cmx5cm depth with 3mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawl plug (4 Nos), for DB complete all as specified & directed.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overll PVC sheathed weather proof service connections one twin core cable flat or circular of aluminium, conductors size 10 Sqmm, stranded conductors.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.30mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre,charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & directed.
S&F in repair ceiling rose surface Bakelite 65mm x 50mm two or three terminals and connecting up.
S&F in repair sub main wiring on and including passing through in existing conduit pipe 1100 Volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm and continuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm of green colour confirming to IS 694/1990. (Note : Two runs of cable with one run of earth wire should measured as one length).
S&F in repair globe shaped for existing garden light in frosted finish made up of Polycarbonate suitable for LED 9/10 watt all as specified and directed.
S&F in repair globe shaped post top lanternin frosted finish made out of polycarbonate including suitable for upto 27W retrofit LED . Make Havells, model No LHDC13126099 or equivalent.
Taking down & refixing of servicable MCBs from any DB of any size, any location complete all as specified & directed.
Taking down & refixing of servicable DB of any size, at any location complete all as specified & directed.
S&F decorative colour of 3 mtr length having pole material GI PU painted pipe and light material as polycarbonate acrylic of length as per Halonix Cat Part No HLDC-45-75-TRI-3M with rated voltage and frequency 240V 150 Hz, system voltage 75W ±10%, system current <0.382mA power factor >0.90 colour out put suffron, white & green (Tiranga colour with same sequence) and driver efficiency ≥80%. Base plate of the pole light shall be of dia 300mm and thickness 12mm PCB hole 260mm dia & 25mm dia light shall be mounted on a half feet PCC plaster, properly fixed with plate and foundation bolts. Make : Halonix, Havells, Bajaj or equivalent as approved by GE.
S.R.Enterprises
M/s Yash Electrical and Maintenance
Hitesh Construction
Shiv Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .