Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.6 L+₹76,420 (3.85%)Rejected-Finance 92 R BIDHAN MARKET SILIGURI 734006 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | L2 | Rejected-Finance L2 | |
| 3 | L3₹21.0 L+₹1.2 L (5.86%)Rejected-Finance LAKE ROAD LAKE TOWN WEST SILIGURI 734007 | SILIGURI | DARJEELING | WEST BENGAL | 734007 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
21 Dec 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NIRANJAN KUMAR DAS/ SE(Electrical)/NBDD
Annex Building, Uttarkanya, Fulbari, Jalpaiguri
Supply and installation of 30KVA/30KW Modular type true on-line configuration UPS with DSP CONTROLLED microprocessor based technology for Annex Building at Uttarkanya, Kamrangaguri in the district of Jalpaiguri.
2022_NBDD_431013_1
NBDD/BS/SE /NIQ-18-(EL) of 2022-2023
Open Tender
Electrical Work/ Equipment
Item Rate
120 days
Uttarkanya
Please refer Tender documents.
6 documents required · 6 mandatory
₹25,000
Yes
31 Jan 2023
7 Dec 2022
23 Dec 2022
16 Dec 2022
21 Dec 2022
16 Dec 2022
Amount
Supply,installation, testing and commissioning of 30KVA/30KW Modular type true on-line configuration UPS with DSP CONTROLLED microprocessor based technology including battery rack, connectors with following specificaton:- Digital Signal Processing (DSP) controlled Microprocessor based technology true On-line configuration. a) Modular UPS design in N+1 redundant configuration with scalability (vertical paralleling) up to 40 KVA.in parallel for forming N + 1 (Configuration) 30 KVA /30KW Modular UPS with N+1 configuration scalable up to 40 KVA means rated capacity of UPS should always be 10 KVA and one extra module should be there to make it N+1 redundant. However the UPS should be scalable up to 60 KVA with N+1 configuration .For example if 10 KVA module is used the UPS should have four 10 KVA module out of which one module is for redundancy. But the module rack should be capable for accommodating 60KVA rated capacity UPS. b) Provision for configuring three or more modules in parallel load sharing mode. Indicate the maximum No. of modules that can be connected in parallel for forming N + 1 (Configuration). Essential Features :Upgradable to ( Three Phase Input/Three phase output/Single Phase Output, Single phase Input/Single Output) as customized solution. c) The requirement is for fully rated capacity of single module in parallel with similar module sharing the load having provision for adding one or two modules of similar units. Paralleling of UPS should be achieved by paralleling the output on the power side using control logic signal bus. Each UPS should be capable of individually starting, running and feeding to the load apart from parallel operation. For vertical scalability in multiple of 10 KVA/10KW. Module Rating 10 KVA each. Inversion technique Adaptive pulse width modulation or sine weighted pulse width modulation with high switching frequency. [ii] Three phase: Input Voltage range 415 V + 15% to -20% In either case, there should be input to output isolation through separate isolation transformer . (External to UPS). Mention detail of isolation transformer. Note: Static bypass arrangement may be connected in such a way that the input and output sides shall always remain galvanically isolated.
Input Frequency 40 to 70 Hz. Generator compatibility Should be compatible with Generator. Type of rectifier DSP controlled IGBT based Rectifier. Technology DSP controlled PWM using IGBTs. Efficiency of Inverter > 94 % at 100% load. Output Voltage 380/400/415VAC ± 1 % Above for 3Ph IP / 3Ph OP. Output Frequency 50 Hz ± 4% (Synchronous to mains) 50 Hz ± 0.1% (free running). Power factor: The UPS shall be provided with Active Input. P.F. Correction system to obtain P.F. >0.99 lag at 100% load. (where the connected load P.F varies. from 0.8 to Unity). Harmonic Distortion (input current) < 3% at 100 % linear load. Wave form (output):Sine wave, Crest factor:>3, Overload capacity:110% for 1 hour, 125% for 10 minutes, 150% for 1 minute, >150% for 200 ms . (during the test the load should not get transferred to mains through static switch). i) Efficiency AC/AC(Overal):>/=94% at full load. Operating temperature:Should be designed for delivering rated KVA at ambient temperature from 0 to 40 Degree Celsius, however it should operate up to 50degree Celsius. Noise level:At 1 meter from the UPS <55 decibles. Relative Humidity:0-95% at 35 C non-condensing. It should be capable to work in the entire geographical region of the Circle including coastal region. Charger:Built in solid state float-cum-boost charger with automatic boost/trickle charge modes with current limiting features. The charger characteristics will be such as to match the float/boost charging of the batteries as per battery characteristic, for enhancing the life of batteries. The charger is designed for at least 15% of the total battery current. Interface Facility:The UPS System has necessary hardware and software with RS 232 port to work on Windows or any OS specified by LICI.. B) Remote Manageability through SNMP Facility. Protection:a) Current limiting protection (Fuse less Electronic). Built in overload/ short circuit protection with snubber circuits for current limit. b) Soft start on inverter and charger arrangement. c) Phase locking mechanism for UPS and mains frequency.- for 3 phase output. d) Over voltage/ under voltage protection. e) Short circuit/ overload protection through MCB / MCCB. f) All other protection systems required for safety of UPS system, such as over temperature protection etc.
g) Protection against earth leakage current by suitable protective devices like negative sequence current sensor/ RCCB. Thyristor based Static (Auto) bye-pass switch:Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from inverter to bypass and vice-versa. Indications:a) Mains ON with phase indication for single phase/ 3 phase separately for. all the phases. b) Inverter ON/ OFF/ FAULTY/ TRIP (Reason) . c) Charger ON/ FAULTY or TRIP (Reason). d) Battery Low. e) Static by-pass ON. f) Over temperature. g) % load. Alarm:i) Low battery alarm and mains failure / load on battery alarm provided. ii) Over temperature alarm in two stage : 1 st stage : Warning 2nd stage : Tripping. Metering:Digital Panel Meter duly calibrated to indicate the following. a) AC Voltage: Input/ Output. b) AC Current : Input/ Output B. % Load, C. DC Battery Voltage, D. DC Charging/ Discharging Current, E. Frequency- Input/ Output, System Controller:The System controller is a redundant device that provides; * All system measurements from modules and Static Switch. * Basic system configuration, * Alarm indications, * Power Analysis * Remote monitoring * Battery handling In case of System controller failure, the operation of the UPS should not change even though the UPS features will not be available. It should also be possible to replace System controller without interrupting the UPS system operation, Event logging at front panel:The display unit should, allow the user to display a time and date stamped log SNMP web Monitoring and software compatibility.:The Ethernet Web/SNMP Adaptor should allow one or more network management systems (NMS) to monitor and manage the UPS in TCP/IP network environments .The management information base (MIB) should be, provided. Battery set:i) Complete with self standing cubicle or cabinet, A. SMF:Battery : 12 V, Mono Block batteries. SMF VRLA Battery. Make:Exide/Quanta, Batteries (To be installed in ventilated/ cooled rooms only):Common Battery(For 1+1) The DC busbar of the two modules are connected to the same battery bank ;DC current is shared between the two rectifiers.
Nominal DC bus voltage:minimum +/-192 V DC, Minimum VAH rating 57600VAH, ISO 9001: 2015, ISO 14001: 2015, ISO 18001, RoHS and OHSAS 18001 , CE Certification:IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950 (Safety) IEC/EN 50091-2, IEC/EN 62040-2(EMC Emmission),IEC/EN 62040-3(performance & Design)IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146 (Design & Manufacture)
Comprehensive maintenance of existing 03 nos 20 KVA (3/3) online UPS system including all spare materials as required.
Comprehensive maintenance of existing 01 no.20 KVA (3/3) modular UPS system (10x2 Module) including all spare materials as required.
A.K.CHOUDHURY AND SONS
M/S. KRISHNA COMMERCIAL CORPORATION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .