| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.2 L+₹1.7 L (7.89%)Rejected-Finance FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹24.9 L+₹3.4 L (15.7%)Rejected-Finance | L3 | Rejected-Finance not being lowest | |
| 4 | L4₹29.9 L+₹8.4 L (38.8%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance not being lowest | |
| 5 | L5₹34.7 L+₹13.2 L (61.2%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L5 | Rejected-Finance not being lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Oct 2022, 6:00 pmClosed
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
Cleaning/maintenance of overhead reservoir and UG sump including certain repair works at water supply installation and repair/replacement of CI/DI/GI pipes, fitting, sluice valve, valve chambers and connected items etc at JCO/ORs MD accn, FCBRNP, CTW
2022_MES_551623_1
8357/E8
Open Tender
Pipes and Pipe related activities
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class D, category a(ii)
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹90,000
Yes
17 Feb 2023
16 Sept 2022
20 Oct 2022
16 Sept 2022
13 Oct 2022
1 Oct 2022
17 Sept 2022 - 30 Sept 2022
Amount
M & L for dewatering and cleaning the RCC over head tank of following capacity at the following location by dewatering the over head tank by any means and cleaning the complete inner surfces by rubbing / scrapping by wire brush to remove the sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely and writting the details of tanks like date of cleaning, capacity of tanks etc on the out side of the tank with synthetic enamel paint with letter size 20 cm high in white colour , over a black background of size 100x60 cm all as specified and directed for 3 lakh GLN capacity ( 2 compartment i.e. inner and outer of capacity 1.5 Lakh GLN) (Loc near FNBCP)
All as per ser item No. 1 above, but 25,000 GLN capacity (CTW and Sub stn No 01)
All as per ser item No. 1 above, but 100000 GLN capacity (SS No 9)
All as per ser item No. 1 above, but 20,000 GLN capacity (MAP ph-I, 454 OR PH, 80/60 single offrs)
M & L for dewatering and cleaning the RCC underground/semi under ground sump at the following location by dewatering the over head tank by any means and cleaning the complete inner surfces by rubbing / scrapping by wire brush to remove the sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely and details of tanks like date of cleaning, capacity of tanks etc shall be written on the out side of the tank with synthetic enamel paint with letter size 20 cm high in white colour, over a black background of size 100x60 cm all as specified and directed of capacity 2,00,000 GLN capacity (Bhosari Pump House)
All as per ser item No.5 above, but capacity 1,50,000 GLN capacity (Bhosari Pump House)
All as per ser item No.5 above, but capacity 50,000 GLN capacity (Bhosari Pump House)
All as per ser item No.5 above, but capacity 10,000 GLN capacity (SS No 1, BD Coy, 2x ARN)
All as per ser item No. 5 above, but capacity 20,000 GLN capacity (P454 PH, MAP PH II)
NOTE: For Item Sl No 1 to 9: cleaning of OHT and UG sump at mentioned above will be carried out twicely with a gap of six month between two consecutive cleanings.
Material and Labour for dismantling the delivery pipe line of submersible pump set of capacity 10 HP from water mains, Lifting/taking out carefully the GI column pipes, submersible cable, defective submersible pump set from bore well for repair by means of chain pulley block or other T&P, transporting to workshop, opening the pump set including repair and servicing of pump, oiling/ greasing, lubricating the parts and reassembling, shifting back to bore well at various sites at CME, complete of depth up to 100 metres including installing, commissioning and testing on full load complete all as specified and as directed by Engr-in-charge. NOTE: i) The quoted rates deemed to be inclusive of jointing of submersible cable, reconnecting the delivery pipe line of submersible pump sets to water mains, testing for satisfactory running & continuous flow of water complete all as specified. ii) The quoted rates deemed to be inclusive of servicing of LT panel of bore well.
Material and Labour for dismantling the delivery pipe line of submersible pump set of capacity 15 HP from water mains, Lifting/taking out carefully the GI column pipes, submersible cable, defective submersible pump set from bore well for repair by means of chain pulley block or other T&P, transporting to workshop, opening the pump set including Repair and servicing of pump, oiling/ greasing, lubricating the parts and reassembling, shifting back to bore well at various sites at CME, complete of depth up to 100 metres including installing, commissioning and testing on full load complete all as specified and as directed by Engr-in-charge. NOTE: i) The quoted rates deemed to be inclusive of jointing of submersible cable, reconnecting the delivery pipe line of submersible pump sets to water mains, testing for satisfactory running & continuous flow of water complete all as specified. ii) The quoted rates deemed to be inclusive of servicing of LT panel of bore well.
Material and Labour for dismantling the delivery pipe line of submersible pump set of capacity 20 HP from water mains, Lifting/taking out carefully the GI column pipes, submersible cable, defective submersible pump set from bore well for repair by means of chain pulley block or other T&P, transporting to workshop, opening the pump set including Repair and servicing of pump, oiling/ greasing, lubricating the parts and reassembling, shifting back to bore well at various sites at CME, complete of depth up to 100 metres including installing, commissioning and testing on full load complete all as specified and as directed by Engr-in-charge. NOTE: i) The quoted rates deemed to be inclusive of jointing of submersible cable, reconnecting the delivery pipe line of submersible pump sets to water mains, testing for satisfactory running & continuous flow of water complete all as specified. ii) The quoted rates deemed to be inclusive of servicing of LT panel of bore well.
Material and Labour for rewinding of defective submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush, washing with pressure water, drying, rewinding the motor with super enamelled copper winding wire of existing gauge and weight including replacement of all insulation material. “O” rings and other petty items required for making motor functional and checking the winding leak proof & taking out the electric connection and provision of suitable size new submersible cable up to 03 mtrs for motors of capacity 10 HP capacity complete all as specified and directed.
Material and Labour for rewinding of defective submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush, washing with pressure water, drying, rewinding the motor with super enamelled copper winding wire of existing gauge and weight including replacement of all insulation material. “O” rings and other petty items required for making motor functional and checking the winding leak proof & taking out the electric connection and provision of suitable size new submersible cable up to 03 mtrs for motors of capacity 15 HP capacity complete all as specified and directed.
Material and Labour for rewinding of defective submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush, washing with pressure water, drying, rewinding the motor with super enamelled copper winding wire of existing gauge and weight including replacement of all insulation material. “O” rings and other petty items required for making motor functional and checking the winding leak proof & taking out the electric connection and provision of suitable size new submersible cable up to 03 mtrs for motors of capacity 20 HP capacity complete all as specified and directed.
Supply and Fixing PVC insulated & PVC sheathed industrial copper conductor cable for submersible pump motor, flat three core of nominal area of conductor 10 Sqmm, 1100 volts including taking down old U/S cable complete all as specified and directed.
Taking out unserviceable starter from position and supply and fixing Fully automatic Star Delta starter in sheet metal enclosure Type MK1 suitable for operation on AC, Three phase four wire , 415 Volts, 50 Hz supply for Motor of capacity 10/15HP complete Cat No SS96259 Make: L&T/ SEIMENS/HAVELLS complete all as specified and directed.
Taking out unserviceable starter from position and supply and fixing Fully automatic Star Delta starter in sheet metal enclosure Type MU-G20 suitable for operation on AC, Three phase four wire, 415 Volts, 50 Hz supply for Motor of capacity 20HP complete Cat No SS95975 Make: L&T /SEIMENS/HAVELLS complete all as specified and directed.
Supply and Fix 3 pole MCCB 100A capacity with S.C. rating of 50kA,415V, 50Hz, thermal and magnetic setting with provided leads on iron frame/lamination board , Type DN0-100M Cat No CM98944OOKO Make: L&T / Standard/Havells/HPL/Indoasain including taking down old u/s MCCB from existing panel all as specified and directed by Engineer In Charge
Supply and Fix 3 pole MCCB 250A capacity with S.C. rating of 50kA,415V, 50Hz, thermal and magnetic setting with provided leads on iron frame/lamination board, Type DN2-250M Cat No CM92171OOPOOG Make: L&T / Standard/Havells/HPL/Indoasain including taking down old u/s MCCB from existing panel all as specified and directed by Engineer In Charge
Supply and Fixing in repairs MCCB 4 pole, Type DU100H, 415 volts 50 Hz AC suitable for current carrying capacity 100 Amps rating, fixed and thermal magnetic release with breaking capacity 30 KA Cat No CM97933OOE2 Make : L&T /Standard/Havells/Indoasian complete all as specified and directed.
S & F in replacement Power Contactor 3-Pole with AC Coil 300 Amps along with Aux. Contacts 02NO & 02NC ,440 volts 50Hz, MNX 250 Make : L&T Cat No.: CS94141 or equivalent make as approved in the existing panel, connecting up and testing all in repairs including material for wiring if required as specified and directed.
S & F in replacement Power Contactor 3-Pole with AC Coil 160 Amps along with Aux. Contacts 02NO & 02NC,440 volts 50Hz MNX 110 Make : L&T Cat No.: CS94137 or equivalent make as approved in the existing panel, connecting up and testing all in repairs including material for wiring if required as specified and directed.
S & F in replacement Power Contactor 3-Pole with AC Coil 160 Amps along with Aux. Contacts 02NO & 02NC ,440 volts 50Hz MNX 140 Make : L&T Cat No.: CS94138 or equivalent make as approved in the existing panel, connecting up and testing all in repairs including material for wiring if required as specified and directed.
S & F in replacement side mounting Add-on Aux. contact block first left/first right along with Aux. Contacts 01NO + 01NC, 440 volts 50Hzsuitable for MNX 95-650 power contactor Make : L&T Cat No.: CS94205/CS94206 or equivalent make as approved in the existing panel, connecting up and testing all in repairs including material for wiring if required as specified and as directed.
S & F Thermal overload relay range type MN2 suitable for 9 to 15 Amps including taking down the old relay including material for wiring if required complete all as specified and directed Cat No SS94142OOBO Make : L&T /Seimens /Havells
S & F in replacement MCB single pole 6A, C curve, 240/415Volts Cat No: BB10060C Make : L&T or equivalent make as approved in the existing panel, connecting up and testing all in repairs including material for wiring if required as specified and directed.
S & F in replacement DIN Type Fuse links Type HN size 2, 400 A as per IS 13703 Part II suitable for Type FN 400/ FNX 400 S-D-F fuse base Make: L&T Cat No. SF 94335 or equivalent make as approved in the existing panel, connecting up and testing all in repairs including material for wiring if required as specified and directed.
Supply and Fix 4 pole MCCB 250A capacity with S.C. rating of 25kA, 415V, 50Hz, thermal and magnetic setting with provided leads on iron frame/lamination board , Type DU250C Cat No CM90634OOPO Make: L&T or equivalent of Standard/Havells/HPL/Indoasain with taking down old u/s MCCB from existing panel all as specified and directed by Engineer In Charg
S& F Non return valve (NRV) without by pass arrangement including provision of joining material such as insertion sheet 3mm thick, nut & bolts all as required at site 80mm dia bore ISI marked complete with rubber gasket all as directed.
S& F Non return valve (NRV) without by pass arrangement including provision of joining material such as insertion sheet 3mm thick, nut & bolts all as required at site 100mm dia bore ISI marked complete with rubber gasket all as directed.
S& F sluice valve class PN 1.6 without by pass arrangement including provision of joining material such as insertion sheet 3mm thick, nut & bolts all as required at site 100mm dia bore ISI marked complete with rubber gasket all as directed.
M & L for cleaning of strainer 400mm dia including opening of strainer top cover by removing nut/bolts, removal of strainer screen and taking out dirt, mud, foreign particles accumulated inside strainer, assembling back and replacemnt of worn out nut bolts and gasket all as specified and directed by Engineer In Charge
S & F in repair Stainless steel wire cloth, 0.71mm nominal dia of wire and average width of aperture 1.40mm, size of mesh 12mm and fixed with tinned tacks,of stainless steel wire staples .and necessary fabrication/frame work for fixing wire cloth complete all as specified and directed by Engr in charge .
S & F illuminated Push Button Projecting Head complete all as specified and directed in RED/GREEN in color, 240V AC, Cat No EG03PDL, Make: L&T/ HPL including taking down old u/s push button of any type
S & F LED Indication lamp for LT Panel board RED/ YELLOW /BLUE, Surface Mounted Device LED technology Low Power consumption < 0.6W Low Voltage Glow Protection (LVGP) Cat No: SIL 240A-240V AC Make: L&T or HPL/Havells
Material & labour for Earthing complete using galvanised iron earth plate electrode of size 60cm X 60cm X 6mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers and protected by light grade 40 mm dia galvanised iron pipe and GI pipe light grade 20mm bore for watering, including funnel, wire mesh, CI pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on electrical plate No. 3 of SSR Part-I for different capacities pumpsets.
Repair & maintenance of Vaccum circuit breaker HT 22KV, 3 phase 50 cycle outdoor type totally enclosure metal clad switch gear complete with VCB having rapturing capacity 350 MVA incl over load earth fault protection relay, ampere meter, volt meter etc maint and of up to rating cap 630 Amps complete all as specified and directed.
Repair & servicing of existing pump starter panels/main panel of various sizes ( for capacity of pump 70 HP) by replacing unserviceable components such as contactor, relays, single phase preventer, meters, cable lugs, etc and tightening of all connecting points, cable connections complete all as directed. (Note parts required for replacement shall be measured and paid seperately as supply only under appropriate items given here in after.)
M & L for repair of u/s Electromagnetic water flow meter (EMF) ISO: 4064,Accuracy +0.5%,Make – Endress + Hauser, Model No - 10L4H-U-20A-1AN4B4AA installed at STP kasarwadi incl Transportation to & from workshop and replacement of u/s spares for meter. Installation and testing of repaired meter on same location all as specified and as direted by Engineer In Charge.
M & L for carry out water quality anyalysis for bacterial, chemical and biological analysis including for collection of water samples from the pump house or from location as specified by Engineer In Charge and testing from NABL approved testing laboratory, submitting of reprort for minimum following parameters (a) Turbudity (NTU) (b) pH (c) Total Hardness as CsCO2 (mg/l) (d) Sulphate as SO2 (mg/l) (e) Iron as Fe (mg/l) (f) Magnesium as Mg (mg/l) (g) E-Coli or thermotolerant coliform bacteria (h) Remarks of NABL approved testing lab
M & L for carry out testing of treated water of STP including for collection of water samples from the STP and testing from NABL approved testing laboratory, submitting of report for following parameters all as specified and directed by Engineer-in-Charge. (a) PH (b) TSS (c) BOD (d) COD (e) Residual Cl (f) Dissolved Oxygen (g) Coli Form (h) E-coli (j) Remarks of NABL approved testing laboratory if any Note: Rate quoted shall be deemed to be included for: (i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample
S&F in repair glow sign board box type printed on poly carbonated sheet of size 200 x 100 x 25 cm having provision of 3 x LED tube light inside the box and 20 mtrs 3 core 1.5 sqmm circular PVC connecting wire with hanging arrangment as directed by engr -in charge. Note :- Background, font size & colour and material to be printed on board shall be as per direction of Engr-in-Charge.
M&L for fixing MS sheet chequered,of size 4 mm thick laid over cable ducts as duct cover complete all as specified and directed.
Dismantling post or strut embeded in concrete (wood/steel/RCC) any section embeded in concrete including taking out embeded portion and making good all as specified and directed.
Dismantling fencing wire mesh of any description complete all as specified and directed.
S&F for hand rails, half round or others stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc, wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for secuing wire mesh etc.,) including all necessary drilling, bolting or reveting etc., and similar work confirming to FE-290 Gde E-165 complete all as specified and directed.
M & L for mild steel screw bolts (machine made) with hexagonal or square heads at one head and screwed at the other, screwed end to be fitted with washers and one hexagonal or square nut, not exc. 5cm long with dia of bolt upto 10mm complete all as specified and directed.
Supply only galvanised mild steel chain link fencing made out of 3 to 4 mm dia galvanised steel wire and of aperture 50mm x 50mm complete all as specified and directed. Note : Fixing shall be measured and paid separately.
Fixing only mild steel chainlink fencing including line wires, any mesh size and type to any type of standards, rails, straining bolts, angles etc., including provision of binding wire complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10cm in width or girth not otherwise specified and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Supply and fix in replacement HV synthetic Insulating mat (ISI Marked) of size 2m x 1m x19mm complete all as specified and directed.
M & L for shifting heavy items / excavating / cleaning areas / clearing site by providing crane/hydra/JCB/tractor with trolley as required at site complete all as per direction of Engr-in-Charge.
Excavation in trenches in soft / loose soil not exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for laying of GI / CI/DI pipe line and making bottom surfaces of excavation levelled all as specified and directed.
Excavation in trenches in, hard /dense soil not exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for laying of GI / CI/DI pipe line and making bottom surfaces of excavation levelled all as specified and directed.
Returning, filling in trenches with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed
Removing surplus soil (spoil) to a distance not exceeding 50 metre away and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 15mm dia all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 20mm dia all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 25mm to 32mm dia all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 40mm to 50mm dia all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 80mm to 100mm dia all as specified and directed.
Supply and laying in trenches Galvanised iron (Gl) tubing 'Medium grade' with screwed socket joints, together with all tube fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) with cutting, screwing, making forged bends on piping as required. insertion of Connectors where required or directed. including cutting through walls, floors, etc. and making good all as specified and as directed for following size of pipes: (Note : Earthwork shall be measured and paid saperately under relavent Item)
15mm bore dia
20mm bore dia
25mm bore dia
40mm bore dia
50mm bore dia
80mm bore dia
100mm bore dia
Supply and fixing to walls and ceilings or laid on floor Galvanised iron (Gl) tubing 'Medium grade' with screwed socket joints, together with all tube fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) with complete with clips, wall hooks, wooden plugs & including cutting, screwing, making forged bends on piping as required. insertion of connectors where required or directed. including cutting through walls, floors, etc. and making good all as specified and as directed for following size of pipes:
15mm bore dia
20mm bore dia
25mm bore dia
40mm bore dia
50mm bore dia
Taking up or down CI/DI water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints including turning water OFF or ON as necessary and taking off and refixing covers, access doors etc. all as specified and directed.
100mm dia
150mm dia
200mm dia
375/400 mm dia
Supplying and laying Ductile iron pipes conforming to IS : 8329 of class K-7, including all specials, laid in trenches conforming to IS : 1536-2001 and ISI marked,suitable for following size of pipe complete all as specified and directed. (Excavation and earth work, joints and jointing material and DI specials will be measured and paid seperately)
100mm dia
150mm dia
200mm dia
375/400mm dia
Providing and laying MS pipes confirming to IS 3589 : 1991 ,thickness 6mm, class C including welding of pipes to each other in which MS pipes connected to existing CI/DI pipes through taper piece and welding, all specials, laid in trenches conforming to IS : 1536-2001 and ISI marked, suitable for following size of pipe complete all as specified and directed by Engr -in-charge. (Excavation and earth work will be measured and paid seperately)
300mm dia
M&L Cutting cast iron / Ductile iron pipes in position for reducing to required length or insertion of new tees, branches, mechanical Joints etc, all as directed for size of pipe 375/400mm bore
All as per item No.71 above, but size of CI/DI pipe 300/350mm bore.
S & F CI/DI fittings, as per IS-1538- 1976 (Part I to XXV) ISI marked, heavy duty, such as CI bends (any type, radius and angle) Tappers any type straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch , Y junctions , double branch, cross complete fixed to walls and ceiling or laid in floors with all fittings (all sockets or socket and spigot), collars, caps , upto 150 mm dia pipe etc complete all as specified and directed.
All as per item No.73 above, but for 200mm to 400mm bore
M & L for detecting water leakage/blockages in underground water pipe lines, turning off/On water and draining the system as required, with necessary excavation at location of leakage/blockage and carrying out repair of GI/CI/DI pipe of any size with tightening of loose connection, removing & cleaning blockage, replacement of u/s fittings & repair/replacement of joints, all as specified and directed. Note: 1. Excavation & earthwork, additional pipe, joint and jointing material shall be paid under respective Items 2. GI fittings such as bends, elbows, tees, reducers, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc upto 80mm shall be included in the quoted rates.
Material and labour for rubber gasket (tyton) joint of size 300 mm CI pipes
Material and labour for rubber gasket (tyton) joint of size 200 mm CI pipes
Material and labour for rubber gasket (tyton) joint of size 150 mm CI pipes
Material and labour for rubber gasket (tyton) joint of size 100 mm CI pipes
Material and labour for rubber gasket (tyton) joint of size 80 mm CI pipes
M & L for Lead wool joint for CI pipe of dia 100mm
M & L for Lead wool joint for CI pipe of dia 150mm
M & L for Lead wool joint for CI pipe of dia 200mm
M & L for Lead wool joint for CI pipe of dia 250mm
M & L for Lead wool joint for CI pipe of dia 300mm
M & L for mechanical type joint made of MS sheet of size 6/8 mm thick along with rubber gasket nuts bolts and washers suitable for 50 mm bore dia of CI/DI pipe.
All as per item No.86 above, but 80 mm bore dia
All as per item No.86 above, but 100 mm bore dia
All as per item No.86 above, but 150 mm bore dia
All as per item No.86 above, but 200 mm bore dia
All as per item No.86 above, but 300 mm bore dia
All as per item No.86 above, but 400 mm bore dia
S&F Gun-metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed including taking down old u/s gate valve of following sizes:
15mm dia
20mm dia
25 mm dia
40 mm dia
50 mm dia
M&L for cutting existing road/footpath incl black top cover up to 1 Mtr depth and 30cm wide (each road not exc 3.2mtr wide) for laying of pipe line, refilling and making good after laying of pipe with removed soil and finally providing PCC 1:3:6 of thickness 150mm to match with the top surface of road. Note: additional length between 3.2mtr to 6.4 mtr measured as two job)
M & L for drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 25mm and providing straight plain brass ferrules (or connecting screws) screwed both ends and fixed on CI/DI/GI pipes all as specified and directed.
M & L for drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 15mm and providing straight plain brass ferrules (or connecting screws) screwed both ends and fixed on CI/DI/GI pipes all as specified and directed.
M & L for drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 20mm and providing straight plain brass ferrules (or connecting screws) screwed both ends and fixed on CI/DI/GI pipes all as specified and directed.
Dismantling and taking out from its position existing unserviceable sluice valve of any size (80mm to 100mm) by unscrewing of nut & bolts etc complete and removing from site all as directed.
Dismantling and taking out from its position existing unserviceable sluice valve of any size (150mm to 200mm) by unscrewing of nut & bolts etc complete and removing from site all as directed.
Supply, fix, and testing non rising spindle type sluice valves both end flanged with stainless steel spindle with gun metal control nut confirming to ISI mark IS 14846/2000, PN-1.6 including provision of jointing material such as insertion sheet 3mm thick, nut & bolts with washer all as required at site of the following sizes
80 mm dia
100 mm dia
150 mm dia.
200 mm dia.
Suply, fix and testing brass spindle with check Nut/ Hub nut (Gun metal) and collars suitable for existing sluice valve of size 400 mm of any make, incl taking down unserviceable complete all as specified and directed.
All as per item No.106 above, but for 350mm sluice valve of any make
All as per item No.106 above, but for 300mm sluice valve of any make
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate including plastering for foundation of MS pipes and used for supprot to MS pipe laid.
Supply & Fixing of Cast Iron Air Valves with two air Outlets, 50mm dia bore and fixing Up in cast iron/ MS Pipe water supply mains incl taking down old unserviceable one all as directed and specified by Enginner in charge.
Supply & Fixing of Cast Iron Air Valves with two air Outlets, 100mm dia bore and fixing Up in cast iron/ MS Pipe water supply mains incl taking down old unserviceable one all as directed and specified by Enginner in charge.
M&L for spraying chemical (roundup/glycel) on area to remove unwanted vegitation/grass at various locations as directed by Engr-in-Charge. Note: (i) Labour and equipments to spray chemical on required area are incl in quoted rates. (ii) Spray will be repeated quarterly or as per direction of Engr in Charge.
S&F in repair glow sign board box type printed on poly carbonated sheet of size 250 x 100 x 25 cm having provision of 3 x LED tube light inside the box and 10 mtrs 3 core 1.5 sqmm circular PVC connecting wire with hanging arrangment as directed by engr -in charge. Note :- Background, font size & colour and material to be printed on board shall be as per direction of Engr-in-Charge.
Cutting of tree branches/grass at sub station compound and removal of all the wasted materials at far distance from sub station, cleaning of ducts including levelling of undulated land complete all as specified and directed by Engr -in-Charge.
Mukund Engineers and Contractors
M/S Eagle Electricals And Rewinding Works
SKS Electricals
ONKAR ELECTRIC AND GENERAL STORE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .