Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-AOC | ₹1.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.2 LRejected-Finance | ₹1.2 L | L2 | Rejected-Finance L2 |
| 3 | L3₹1.2 LRejected-Finance | ₹1.2 L | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹2,400
Closing Date
28 Jan 2026, 5:00 pmClosed
Executive Engineer (A-M) Burdwan (A-M) Division
Kalna Road, Near Agril Farm, Purba Bardhaman- 713101
Annual maintenance of Internal Wiring of Pump House Kiosk Box and repairing and heat varnishing of motor at different RLI scheme under Patuli (Agri Mech) Sub Division of Purba Bardhaman under Executive Engineer(AM) Burdwan (AM) Division
2026_WRDD_990482_1
WBWRDD EEAM BDN eNIT-36 (Sl No 01-04) NP 2025-26
Open Tender
Miscellaneous Works
365 days
Patuli AM SD, Purbasthali-II Block
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,400
6 Mar 2026
19 Jan 2026
30 Jan 2026
19 Jan 2026
28 Jan 2026
19 Jan 2026
Annual maintenance of Internal Wiring of Pump House/ Kiosk Box and repairing & heat varnishing of motor at different RLI scheme under Patuli (Agri-Mech.) Sub-Division of Purba Bardhaman District under Executive Engineer(AM) Burdwan (AM) Division during the Financial Year 2025-26 under Non plan.( Please see the details in Sheet Barge)
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Supply, Fitting & fixing of DPIC main switch 15/16A 240 Volts (Havells) on board on wall including mending good the damage for light circuit of pump house . (PWD ELECT. schedule.Page-D-1,Item-1(a)
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set. (PWD ELECT. schedule.Page-D-13,Item-23)
Wiring from 15/16A DPIC main switch to Busbar box in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) of 2 x 36/0.3(2.5 Sq. mm) + 1 x 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc incl supply of wire. (PWD ELECT. schedule.Page-E-11,Item-1)
Wiring from 15/16A DPIC main switch to BDB in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 2X 36/0.3(2.5 Sq. mm) + 1 X 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc.incl supply of wire . (PWD ELECT. schedule.Page-E-11,Item-1)
Distribution wiring in 1.1KV grade 2 x 22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including necessary PVC clips,fittings etc. to light/fan/calling bell with piano key type switch of (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works incl. supply of wire.[PVC casing capping and switch board both on surface] average run 5 meter . (PWD ELECT. schedule.Page-E-21,Item-1 (a)
Distribution wiring in 1.1KV grade 2X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including necessary PVC clips,fittings etc. to 5amps 3 pin flush type plug socket with piano key type switch of (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works.[PVC casing capping and switch board both on surface] average run 1.5 meter . (PWD ELECT. schedule.Page-E-22,Item-5(6)
Fitting & fixing of 100/200A 500 V iron clad/ sheet steel TP/ TPN main switch on iron legs on wall . (PWD ELECT. schedule.Page-C-1,Item-1)
Fitting & fixing of 63A 500 V iron clad/ sheet steel TP/ TPN main switch/isolators on iron legs on wall . (PWD ELECT. schedule.Page-C-1,Item-1)
Fitting & fixing of only 63A/100A/200A 500V iron clad M.S. sheet metal busbar chamber on angle iron frame on wall for 4 bars 63Amps . (PWD ELECT. schedule.Page-C-1,Item-6)
Fitting & fixing of Star - Delta starter (for 20 HP motor contol) on angle iron frame on wall. (PWD ELECT. schedule.Page-C-1,Item-7(b))
Fitting & fixing of Volt meter and Ammeter with necessary screws and other fixing materials including making holes where necessary and making connections. (PWD ELECT. schedule.Page-C-2,Item-10)
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box, including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to lEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex) [a] For Major RLI (i) 4Cx 25 sqmm Copper cable conforming to IS 694 in [100/200 A TPN switch to BUS-bar . (Ch-6.0 para9.00,Sl.no-14,Page-42 of WRDD.)
(ii) 3C X 16 sqmm copper cable conforming to IS 694 [Busbar to 63 A, TP Main switch and 63 A TP switch to Motor starter]
(iii) 2 X 3C X 10 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (lSI-Medium quality) IfStar-DeltaMotor starter to Motor]
Suppling & fitting & fixing of danger Board (mannual) 4"x6" in two distinguishing position in the door of pump house (outside) and at the palce of panel board.(PWD ELECT. schedule.Page-D-13,Item-21(a))
Earthing with 50 mm (2") dia Galvanized iron pipe(TATA MAKE) 3.64 mm thick X 3.04 mtr.(10ft) long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm (1/2") dia X80 mm (3") long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. (12") below the ground level and restoring the surface duly rammed for Soft/Morrum soil by ISI-Medium G.I. Pipe. (PWD ELECT. schedule.Page-G-1,Item-2(a))
Supplying and fixing earth bar of galvanized M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilloed holes (on busbar) about 3 cm. apart complete with G.I. bolts, nuts, washers etc. as required for tapping. (PWD ELECT. schedule.Page-G-2,Item-4(a))
Connecting the equipments to earth busbar including supplying and fixing G.I. Wire No. 8 SWG on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages..(PWD elec. Sh. 2017 Page-G-2, item-5(a))
Placing and positioning the Centrifugal pump motor set on the pump base/pump house floor, alligning properly with necessary packing and fixing the set with holding down nuts and washer including cutting holes of requisite size in the floor / base, grouting the bolts and mending good all damages- complete as per direction of Engineer-in-Charge. (WRDD Schedule-2018, Item no. 3.00/1) 20 HP capacity )
Supplying, fitting & fixing of 63 Amps , 100 Amps, 415V rewireable type porcelain body Fuse top & base complete set conforming to IS: 13947/Part- 4/Sec-1/1993 over wooden plankl board on wall and making necessary connection with the electrical cable as per direction of the E.I.C. (WRDD Schedule-2018, Ch-9.00 ,Item no. 9(ii), Page-42 )
Repairing of Main Switch For 63 Amps/100/200 Amps (REWIREABLE TYPE) by taking out and fitting fixing Action Bar with U-Clip setting &End Shield Block with connecting wire(to be supplied departmentally) with testing as per direction of the Engineer-in-Charge. (WRDD Schedule-2018, Ch-9.00 ,Item no. 20, Page-43 )
Repairing of Manually Operated Heavy Duty Star/Delta Oil Immersed Starters by taking out and fitting fixing No Volt Coil & Overload Coil(to be supplied departmentally) with testing as per direction of the Engineer-in-Charge. (For 100Amp/63Amp) (WRDD Schedule-2018, Ch-9.00 ,Item no. 16, Page-43 )
Motor heat varnishing, reassembling & Testing etc. all complete. (all type of electro motor of 17.5/20 HP 3ph. 400/415 volt ).(Item No. 08/4.00/Pg No.25 of WRIDD 2018)
Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger. (WRDD Schedule-2018, Ch-9.00 ,Item no. 15, Page-43 )
Labour charges for fitting & fixing of ball bearing & Motor bering change(Materials to be supplied by office store) (All type of elrctro motor.17.5/20 HP3ph. 400/415 Volt).
Motor Terminal plate change (All type of elrctro motor.17.5/20 HP. 400/420 Volt).
Sub-Total
Add GST @18%
Cost of civil works excluding Labour welfare cess
Add Labour welfare cess @ 1%
Cost of civil works including Labour welfare cess
Total =
Say Rs.
One Lakh Sixteen Thousand Two Hundred & Forty Seven Only
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.87 MB
Tendernotice_2.pdf
PDF • 1.24 MB
BOQ_2421286.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid