Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹27,000
Closing Date
5 Oct 2026, 2:00 pm4d left
SE MI NCTPS1 CH 120
O/o SE MI NCTPS1 CH 120
NCTPS I SE MI Circle AOH 26 27 BM Dn Unit I Rectification Renewal of overheated sagged eroded Radiant roof tubes in inter pass by phased manner plastering of refractory and rectification of skin casing sheet in penthouse and other allied works d
2026_EB_709608_1
CE SE MI NCTPS I 112 26 27
Open Tender
Power/Energy Projects/Products
Works
18 days
Works
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹27,000
Yes
30 Sept 2026
30 Sept 2026
6 Oct 2026
30 Sept 2026
5 Oct 2026
30 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | U-Clamp | 90 | Nos | 27,200 | ₹24,48,000 |
| 2 | Cotter Pin M 39 X3X175 MM, HT Head Bolt (Half Thread) with Spring and Washer. | 10 | Nos | 26,323 | ₹2,63,230 |
| 3 | Channel Size:140 mm x 100 mm x 1000 mm carbon steel | 6 | Mtrs | 21,624 | ₹1,29,744 |
| 4 | Corton Steel Plate 3.15 mm Thick | 4 | MT | 14,172 | ₹56,688 |
| 5 | Skin casing expansion joint for radinat roof (1.5M length) | 20 | Nos | 9,448 | ₹1,88,960 |
| 6 | Super castable refractory Tricast CC70 Super-1450 Application Temperature: 1450°C Maximum grain size: 5 mm Water Required for casting: 10-12% Make: PKV Refractory/ Madras Refractory/ Total globe or equivelant | 10 | MT | 6,182 | ₹61,820 |
| 7 | GI corrugated sheet 920mm X 1830 mm thick 18 SWG Material: | 20 | Nos | 1,802 | ₹36,040 |
| 8 | Charges for leading, lifting and arranging platform and scaffolding in platen SH coil to facilitate rectification of sagged Radiant tubes, and roof dismantling completion of work. Including consumables and hire charges for T&Ps. | 3 | Nos | 901 | ₹2,703 |
| 9 | Charges for bending of plates :
Drawal of 3.15 / 10 mm M.S plate from central stores transporting the materials to outside workshop cutting in to required size, bending to the required size and profile, transporting back to NCTPS boiler area. | 1.5 | Ton | 9,273 | ₹13,909.5 |
| 10 | Charges for renewal of overheated / sagged /eroded radiant roof tubes in second pass for 10 Nos of tube (1 tube required 4 joints) of size 51 mm X 5 mm (above 44.5 mm dia) including cost of consumables and T&Ps (Required tubes will be supplied by TNPGCL) | 40 | Nos | 5,604 | ₹2,24,160 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
BOQ_852665.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .