GARRISON ENGINEER DAMAN
Garrison Engineer Daman, Tat RakshakVihar, Dalwada, Nani Daman Post, Daman (UT) PIN396210
REPAIR AND MAINTENANCE OF HT/LT U/G CABLES, DISTRIBUTION TRANSFORMERS, ISOLATION TRANSFORMERS, SERVO VOLTAGE STABILIZERS, SWITCH GEARS, GOD, EARTHING RTC AT ICGAS DAMAN,REPAIR AND MAINTENANCE OF LT PANEL BOARDS, FEEDER PILLAR BOXES, APFC PANLES, U/G
2024_MES_636519_1
8761/E8
Open Tender
Civil Works
Works
330 days
DAMAN
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER DAMAN
₹54,000
15 Mar 2024
9 Jan 2024
15 Feb 2024
9 Jan 2024
12 Feb 2024
23 Jan 2024
Amount
Repair and Maintenance of SFC ( Static Frequency Converter) unit phase output 208V and Phase to Phase 120V, suitable for three phase of IP 44 protection incl checking all connected SMF battery. Checking all parts and replace only faulty parts like metering equipment with digital ammeter, voltmeter , frequency meter, voltage adjustment +/- 10% of nominal voltage incl battery on/off switch , manual bypass switch, indication lamps for input and output , cooling fans and including protections/indications of output under/over voltage , output over load/short circuit , input over/under voltage , input phase fail/reversal , over temrature , low battery , battery fuse protection , IGBT fuse protection etc complete servicing and replace ment of disply card, power card, inverter card if faulty and also shall have check all parts and wiring cable or main connection cable replace faulty parts/ cable after fault finding located at RMTE Lab, complete all as specified and directed by Engr-in-Charge . Make of SFC unit : Protect Services
Supply and fix in repairs on-load change over switch 315 Amps, 4pole, 3 phase, 415V, 50Hz, front handle operated, open execution type in existing panel board after making addition/alterations and connecting of existing cables by providing suitable lugs, nuts,bolts & washers etc, testing after disconnecting electric connection, complete all as specified and directed.
Supply and fixing in repairs of capacitor bank capacitor 20KVAR, MPP type, 415volts, 50Hz in existing panel boards and connecting of existing cables with proper lugs and testing including removing old unserviceable items, complete all as specified and directed.
Supply and fixing in repairs of capacitor bank capacitor 15KVAR, MPP type, 415Volts, 50Hz in existing panel boards and connecting of existing cables with proper lugs and testing including removing old unserviceable items, complete all as specified and directed.
Supply and fixing in repairs of capacitor bank capacitor 10KVAR, MPP type, 415volts, 50Hz in existing panel boards and connecting of existing cables with proper lugs and testing including removing old unserviceable items, complete all as specified and directed.
Supply and fixing in repairs of capacitor bank capacitor 5KVAR, MPP type, 415volts, 50Hz in existing panel boards and connecting of existing cables with proper lugs and testing including removing old unserviceable items, complete all as specified and directed. Make for item No 2 to 6:- Epcos/L&T/Schnieder
Filtration & Dehydration of transformer oil in distribution transformer, servo voltage stabilizers, isolation tramsformer and HT OCBs (at different locations) using ON-LINE electrically operated filtration plant to achieve dielectric strength minimum 50 KV/ 4mm including testing of oil before and after dehydation and also topping up of the transformer oil upto required level, complete all as specified and directed. Note:-(i)Transformer oil supplyng and top-up shall be measured and paid separately. (ii) The quoted rates shall also be deemed to include for submission of test reports for testing as specified above (iii) Quantity payable under the item shall be the Qty of oil filtered and dehydrated only.
Supply only transformer oil conforming to IS 335-1993 (Make : 'Savita', 'Power Oil', APAR) having di-electric strength minimum 50 KV/4mm, complete all as specified and directed.
Supply and fix in repairs breather assembly including silica gel component suitable for indoor type transformer of 160 KVA to 400 KVA capacity, complete all as specified and directed.
Material & labour in repairs for HT Danger notice plate of size 25x20 cm made cut of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with and including M.S. clamps, bolts and nuts of approved size, complete all as specified and directed.
Supply and fix in repairs 11 KV air break gang operated device of rating 400 amps, 3Pole, vertical type, mechanically operated,mounted on and including 11 KV porcelain insulators and steel frame with operating machanism worked from ground level with and including GI tubing 25 mm bore light grade and providing ACSR conductor jumpers duly crimped with lugs, includin steel work connected to existing 11 KV supply and testing and including removing old unserviceable items complete all as specified and directed.
Material and labour for high tension lightning arrestor, expulsion type suitable for 11 KV with all fittings of transmission class, discharge capacity 65 Kilo Amps and testing including removing old unserviceable item, complete all as specified and directed. Make :- OBLUM/ELPRO/ATLAS/BHEL.
Supply and fixing drop out fuse unit expulsion type for outdoor air break gang operated switch, single pole, mounted on and including insulators for 11 KV working pressure, fixed to and including channel with nuts, bolts and washers etc,synthetic bounded fuse carrying tube with line taps and suitable for current carrying capacity 25 Amp to 50 Amp, testing including removing of old U/S items, complete all as specified and directed.
Supply & fixing in repairs LED phase indicating lamp R Y B colour as required at site in existing panel boards complete all as specified and directed.
Disconnecting of LT and HT cables carefully from the existing Transformer of capacity 400KVA, 11KV/433 volts of any make/type opening of top cover and decanning of transformer oil, checking of connections internally, tightening of all connections, HT and LT bushing and studs and soldering and brazing the connections including removal of sediments, carbon deposits at bottom of transformer tank, on core, on winding etc, cleaning of oil tank and rectification of leakage problem and renewal of all gaskets and assembling and filling back of tranformer oil including top up of tranformer oil upto required level and testing, complete all as specified and directed. Note:-Transformer oil for top up will be measured and paid separately
Disconnecting of LT and HT cables carefully from the existing Transformer of capacity 200 to 250 KVA, 11KV/433 volts of any make/type opening of top cover and decanning of transformer oil, checking of connections internally, tightening of all connections, HT and LT bushing and studs and soldering and brazing the connections including removal of sediments, carbon deposits at bottom of transformer tank, on core, on winding etc, cleaning of oil tank and rectification of leakage problem and renewal of all gaskets and assembling and filling back of tranformer oil including top up of tranformer oil upto required level and testing, complete all as specified and directed. Note:-Transformer oil for top up will be measured and paid separately
Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for primary (HT) side of transformer capacity 400KVA, 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed.
Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for primary (HT) side of transformer capacity 200 to 250 KVA, 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed.
Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for secondary (LT) side of transformer capacity 400KVA, 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed.
Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for secondary (LT) side of transformer capacity 200 to 250 KVA, 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed.
M&L for prepartion of old paint with electrically operated spray machine surfaces of transformer 200 to 400 KVA capacity, 11KV/433 Volt of any make/type including removing of any oil spillage etc and applying two coats of synthetic emanel paint of shade as per existing, complete all as specified and directed.
Material and labour for fault finding and fault rectifying including cable jointing kit cold shrinkable of HT cables of size 95 to 120 sqmm, 3 core and any length with fault detective machine by thumbing method and suitable voltage and all as per manufactures instructions complete all as specified and directed.
Taking out existing underground defective cable of any type and size from the trenches and from any other locations (including taking out of cable covers, pipes etc) complete all as directed.
Supply, laying, testing and commissioning HT cable 11 KV grade, XLPE insulated (earthed) screened, PVC bedded, galvanized iron strip armoured with stranded aluminium conductor cable of cross sectional area 120 sqmm; 3 core, ISI marked with IS:7098 (part-II) as amended upto date in trenches/ ducts/ through pipes etc and making connection by providing suitable aluminium lugs with proper crimping, complete all as specified and directed. Note :- (i) Excavation & Earth work,sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make of cable:- Polycab/Havells/KEI/Finolex (ISI Marked)
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 185 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed. Note :- (i) Excavation & Earth work,sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make :- Havells/polycab/KEI/Finolex ISI Marked
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 150 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed. Note :- (i) Excavation & Earth work,sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make :- Havells/polycab/KEI/Finolex ISI Marked
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 120 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed. Note :- (i) Excavation & Earth work,sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make :- Havells/polycab/KEI/Finolex ISI Marked
S&F cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with and including jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 120 Sqmm, also including connecting with single thimbles etc after disconnecting of electric supply including removing burnt out jointing kit etc, complete all as specified and directed.
S&F cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint, complete with and including jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 120 Sqmm, also with and including connecting single thimbles etc after disconnecting of electric supply including removing burnt out jointing kit etc, complete all as specified and directed.
Material and labour for painting of HT 4 pole structure consisting of steel tubular poles, bracing, cross arms, channels,clamps, supports, nuts, bolts with two coats of Silver paint over a coat of red oxide primer after preparing the existing external surfaces and marking of nomenclature of pole with black paint and including making alternate strips each of 30 cm height with black and red synthetic enamel paint upto 1.20 mtr height from top of PCC copping, complete all as specified and directed.
Material & labour for painting of HT two pole structure consisting of steel tubuler poles and connected steel sections such as bracing, cross arms , channels, supports, clamps , nuts , bolts of any type with two coat of aluminium paint over a coat of red oxide primer after preparing the old painted external surfaces and marking of nomenclature of pole with black paint and including making alternate strips each 30 cm with black and red synthetic enamel paint upto 1.20 mtr height from ground level complete all as specified and directed .
Material & labour for GI tubes, "light grade", 80mm bore with and including all fittings laid in trenches/road crossing/floors etc for cable protection, complete all as specified and directed. Note: Excavation and earth work shall be measured and paid for separately.
Supply and fix in repair MCCB, 250 Amps, 36 KA, 4 pole, 415 volts, 50Hz and making cable connections and testing complete all as specified and directed.
Supply and fix in repair MCCB 160 Amps, 36 KA, 4 pole, 415 volts, 50Hz and making cable connections and testing, complete all as specified and directed.
Supply and fix in repair MCCB 125 Amps, 16 KA, 4 pole, 415 volts, 50Hz and making cable connections and testing, complete all as specified and directed.
Supply and fix in repair MCCB 63 Amps, 16 KA, 4 pole, 415 volts, 50Hz and making cable connections and testing, complete all as specified and directed.
Supply and fix in repair MCB 63 Amps, 10 KA, 4 pole, 415 volts, 50Hz and making cable connections and testing, complete all as specified and directed. Make for item No33 to 37 :-Schneider/Standard/Legrand/L&T/Havellls (ISI marked)
Dismantling the existing indoor type, 11 KV HT OCB, of rupturing capacity 400 Amps from location and repair /overhauling of spring drive mechanisum, coil, auxilary switch including setting of over load coil,no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting HT bushing male and female and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, toping up of transformer oil, HV testing, and assembling all items/components parts to the respective postion & testing complete all as specified and directed by engineer-in- charge .(Note: spare parts and new transformer oil will be measured & paid separetly . )
Supply & fixed in repair spout insulator assembly of HT OCB 11 KV , 400 amps indoor type including HT tape and hardware complete all as specified & directed by engineer in charge
Supply&fixed in repair of OCB through insulator assembly suiatabale for OCB,11KV,400Amps,indoor type including HT tape and hardware complete all as specified & directed by engineer in charge
S&F in repairs strip type heater 500watt With control wiring and thermostst suitable for 400 Amps,11KV 250 MVA, OCB indoor type complete all as specified and directed by Engr-in-Charge.
Taking out the LT ACB 630 Amps to 800 Amps capacity of any make and model from the existing position after disconnecting of electric supply , carrying out genaral servicing , overhauling, cleaning the parts thoroughly with cleaning agents and applying lubricant oil and grease for the moving contacts after removing the carbon deposits and cheking the trip device system and circuit control wiring and reparing of push button system complete and reconnecting back and testing complete all as specified and directed
M & L for complete servicing and maintenance of HT breaker 630 Amps to 800 Amps panel including cheking of contacts, lubrication of mechanism, cleaning, tightening , Insulation Resistance Test for existing rated H.T beaker . Tightening and replace of all control wiring panel,repair and replace to manual/electrical closing/trippping. Opening of panel back covers, removing and replace of Bus bar, revamping of CT ,removing of PT, removing of Ct's, cleaning of all bus bar and replace all sleeves and all space heaters , CT chamber and heating up chamber to remove moisture pressure test with pressure test kit.complete testing of breaker ,checking mechanism of fixed and moving contacts and removing carbon deposits and overhauling and replace of spring charged mechanism and operation of indicators are correctly showing the ON/OFF and spring charged / discharged system, cleaning the surfaces of insulators, and replace all insulators of 11 KV bus bar , fasten the bolts fixed in interrupting units, mechanism linkages etc. lubricating and greasing the mechanism of moving parts and reparing and replace of trip push button assembly including testing and calibration of protection relays and installation of battery set for continious DC supply to relay and also replace of MICOM P111- O/C & E/F relay and reconnecting back the VCB and testing complete all as specified and directed. Note:- The quoted rates shall also be deemed to include for submission of test reports for testing as specified above
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation, Cable, Pipe etc and 10 Sqm on plan and not exc 1.5 metre in depth for pits, independent holes, pole foundation etc, including getting out in any type of soil, complete all as specified and directed.
Returning, filling in with approved earth including spreading, leveling, watering and well ramming in layers n exc 25 cm thick, complete all as specified and directed.
Removing excavated material/soil to a distance not exc 50m and depositing where directed at a level not exceeding 1.5metre above the starting point , complete all as specified and directed.
Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches upto 23 cm and punning to 18 cm complete all as specified and directed. Note: Punned thickess i.e 18 cm shall be measured for payment purpose.
Supply and laying unreinforced precast factory made concrete cable cover, class HV, Type -I, flat, size 300 mm x 180mm x 40mm,ISI marked complete all as specified and directed.
Supply and laying unreinforced precast factory made concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm, ISI marked complete all as specified and directed
Supply and fix pin type insulator porcelain, vitreous white, brown or green including one galvanised mild steel spindle, two washers and one nut of size 150 mm height &150 mm dia of working pressure 11 KV grade including removing of old unserviceable item complete all specified and directed
M&L for prepartion scrubing removing of old paint and painting with electrically operated spray machine surfaces of HT Panel/ HT OCB / feeder piller box of any type/make including removing of old paint with scrubing etc and applying two coats of synthetic emanel paint of shade as per existing, complete all as specified and directed.
M& L for cutting of branches at any height of trees surrounding to the street light pole which obstruct the light to reach the ground and removing from the site to said area whrere specified and directed .(cutting tools, ladders and connected items deemed into the quoted rates)
Material and labour in repairs for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 25 X 4 mm from earth electrode to test point or up-to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Part-I provision of G I Pipe 40mm bore eight grade for protection of GI strip and GI watering pipe of 20 mm bore medium grade,GI funnel with wire mesh,including char-coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1,excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed.
Repairs to boom barrier electrically operated type,230 volts of make Godrej and opening of boom barrier assembly examine thoroughly and carry out servicing ,overhauling,grasing and replacement of spare parts/accessories such as control board,slow shaft, lever arm, release lever lock cylinder,boom bar including replacing of suitable nuts,bolts and washers etc and certain minor items and testing for its efficient functioning complete all as specified and directed. Note:-(i) Spare parts/accessories will be measured and paid separately under relevent item of schedule as supply only. (ii) Labour element for fixing of supply only items and removing of old unserviceable item are deemed to be included in quoted rate. (iii) The work shall be carry out through OEM only.
Supply only control board suitable for boom barrier of existing make Godrej
Supply only lever arm suitable for boom barrier of existing make Godrej
Supply only release lever lock cylinder suitable for boom barrier of existing make Godrej
Supply only boom bar for boom barrier of existing make Godrej
Repairs to "Road Blocker" electro-hydrualic driven type including checking of blocking segment and under ground housing and carry out lubrication of bearings,joint heads of hydraulic cylinders, check all functional components,connections etc and electrical control unit installed in the separate steel drive unit housing, hose connections to the drive unit in the under ground housing.Cleanining the under ground housing properly without damaging to other parts.Checking up the hydraulic unit with motor 5.5 KW,415 volts ,50Hz, pump: 22.0 l/min, control valve and tank, hand pump including carryout works such as loosen the screw of the oil filler socket at the filter and remove contamination, adjust the valves, control assembly and remove oil residue, titaning of all hydraulic connection hoses, checking up revers flow filter, adjust the operating pressure.Checking up the electrical control unit, PLC based control SE 140 unit ,loop detector,transformer,contactor electrical and electronic circuit system and rectify the defects by replacing certain minor spares such as fuses,terminal connectors,copper conductor control cable, gaskets, spring washers,nuts,bolts and washers of any type and replacement of hydraulic oil and spare parts/accessories such as throttle valve, push button(Open-Close) ,proximity switch, pressure gauge, electronic 24 Volts power supply charger, power contractor 3 pole, suitable for 5.5 kw motor, 415 volts,50Hz,transformer, power supply box etc and including servicing, greasing,overhauling of blocking segment,under housing and hydraulic unit assembly with motor pump and control valves and testing the complete road blocker working system as per as per manufacturer specifications complete all as specified and directed.
Note:- (a) Make of the road blocker is Tescon(Godrej) type No TC-VCB 1100/CR926/400 of comprising the following design parameters and specification:- (i) Blocking width:4000 mm size. (ii)Raised height :1100 mm (min) (iii) Crash rating : 6.8 tonnes vechicle weight (min) with Nil penetration PAS 68:2010 or ASTM-M50(DOS-K-12)certified (iv) Static equivalent load (impact load):926KN (min) (v)Raising time: 1.5 second(max) (vi) Lowering time :3.0 second (max) (vii)Driving unit: Electro hydrualic (viii) Operating temparature : (-) 5 to 50 degree C (ix) Normal position: NC (normally closed) / lowered (x)Axle weight: withstand to 100 KN (min) (xi) Features : Manual operation during power failure by integrated hydraulic hand pump. (xii) Operation on power supply:- 3 Phase,415V,50Hz. (b) Spare parts/accessories/hydraulic oil will be measured and paid separately under relevent item of schedule as 'supply only'. (i) Labour element for fixing of supply only items and removing of old unserviceable items are deemed to be included in quoted rate (ii) The work shall be carried out through OEM only.
Supply only hydraulic oil type HV 132
Supply only Solenoid switch
Supply only Relay contactor
Supply only Hydrualic jack bearing
M&L for prepartion of old paint with electrically operated spray machine surfaces of LT panel/feeder piller box of any type outdoor/indoor including removing old paint with scrubing and applying two coats of synthetic emanel paint of shade as per existing over a coat of red oxide primer, complete all as specified and directed.
Supply and fix in repair MCCB 63 Amps,16 KA,415 volts,FP,50 Hz complete all as specified and directed.
Supply and fix in repair MCCB 100 Amps,16 KA,415 volts,FP,50 Hz complete all as specified and directed.
Supply and fix in repair MCCB 160 Amps,25 KA,415 volts,FP,50 Hz complete all as specified and directed.
Supply and fix in repair MCCB 200 Amps,35 KA,415 volts,FP,50 Hz complete all as specified and directed.
Supply and fix in repair MCCB 250 Amps,35 KA,415 volts,FP,50 Hz complete all as specified and directed.
Supply and fix in repair MCB 40 Amps,10 KA,415 volts,FP,50 Hz complete all as specified and directed. Make for I No 2 to 8 :-Schneider/HPL/Legrand/Standard.
Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 3.15 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate,aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length,incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of GE to sent the site requirement complete all as specified and directed including comprising of following :- Incommer (a) ACB 800 Amps, 4 pole, 50KA, 415 Volts AC 50 Hz, draw out type, manual spring charge mechanism, digital voltmeter 0-500 Volts and ammeter 0-600 Amps, CT's, LED phase indicating lamps complete -01 No. Outgoing (a) MCCB 400 Amps, TPN, 36 KA, 415 volts, 50 Hz supply - 01 No. (b) MCCB 350 Amps, TPN, 36 KA, 415 Volts, AC, 50 Hz -03 No. (c) MCCB 250 Amps,TPN, 36 KA, 415 Volts, AC 50 Hz -02 Nos. (d) MCCB 100 Amps, TPN, 25 KA, 415 Volts, AC, 50 Hz -03 No. (e) Copper bus bar 800 Amps, TPN - 01 Set. (f) Change over switch - 320 Amp
Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz Outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate,aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length,incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of GE to sent the site requirement complete all as specified and directed including comprising of following :- (a) MCCB 250 Amps,FP, 36 KA,415 volts,50Hz-1 No (Incomer) (b) MCCB 63 Amps,TPN, 25 KA,415 volts,50Hz-3 No (Outgoing) (c) MCB 40 Amps,TP, 10 KA,415 volts,50Hz- 9 Nos (Outgoing) (f) Digital voltmeter,with VSS , Digital, Ammeter,with CTs & ASS-01 set (g) LED phase indication lamps RYB-01 set (h) Aluminium bus bar TPN 400 Amps rating -01 set
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 240 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed. Note for :- (i) Excavation & Earth work,sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make :- Havells/polycab/KEI/Finolex ISI Marked
Supply,lay and testing LT cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 16 sqmm; 4 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed.
Supply and lay GI pipe 50mm dia light grade in any length with all GI fittings such as socket, elbow, bend, union, Tee etc laid in trenches/duct/culvert/road crossing etc for protection of cables including removing old unserviceable item complete all as specified and directed. Make :- Jindal/Tata/BST
Material and labour in repairs for synthetic insulating mat of 2 mtr x 1mtr x19 mm thick complete all as specified and directed
Material and labour for fault finding of LT cables of size 70 to 240 sqmm X 3.5 core and any length with fault detective machine by thumbing method and suitable voltage and all as per manufactures instructions including providing straight through joint and additional cable of same existing size suitable to site requirement complete all as specified and directed.
Supply & fixing in repairs LED phase indicating lamp R Y B colour as required at site in existing panel boards complete all as specified and directed. Make :- Schneider/HPL/Legrand/Standard
SHRI SULAI ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .