| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.5 LAccepted-AOC 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹55.5 L+₹2.0 L (3.81%)Rejected-Finance 17 23 K P ROY LANE KOLKATA 700 031 | KOLKATA | KOLKATA | WEST BENGAL | 700031 | L2 | Rejected-Finance Quoted Higher Rate | |
| 3 | L3₹57.2 L+₹3.7 L (6.95%)Rejected-Finance | L3 | Rejected-Finance Quoted Highest Rate |
Tender Value
₹53.5 L
EMD Value
₹1.1 L
Closing Date
19 Oct 2024, 4:00 pmClosed
SE,KHEC,PWD
Kolkata Health Electrical Circle, P.W.Dte KIT Annex Building, 5th Floor KOLKATA
Proposed vertical extension, 4th Floor to 9th Floor of State Health Transport Organization, SHTO Building at 142, AJC Bose Road, Kolkata -700014 proposed to be used as Directorate of Drug control, Head Quarter, Govt. of West Bengal--- SITC of Air Con
2024_WBPWD_749123_1
WBPWD/SEKHEC/CKHED/eNIT13/ 24-25
Open Tender
A/C ORG
Item Rate
60 days
Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹1.1 L
Office of the SE,KHEC,PWD
28 Apr 2025
12 Sept 2024
21 Oct 2024
24 Nov 2025
24 Nov 2025
23 Sept 2024
19 Sept 2024
Amount
Supply, Installation, Testing & Commissioning of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (5.2 KW - 5.3 KW), with fixed speed rotary compressor, refrigerant gas R32/ R410A,, Air flow range CFM (560 - 600), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas)
Supply, Installation, Testing & Commissioning of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (6.6 KW - 7.0 KW), with fixed speed compatible rotary compressor, refrigerant gas R 32 / R 410A, Air flow range CFM (780 - 850), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas)
Supply, Installation, Testing & Commissioning of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (8.72 KW - 8.79 KW), with fixed speed rotary compressor, refrigerant gas R 32 / R 410A, Air flow range CFM (950-1050), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas)
Supply, Installation, Testing & Commissioning of Concealed type split AC machines having Cooling Capacity range (a set of full metal body indoor and outdoor unit) (9.8 KW - 11.00 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 ,minium Air flow range CFM (1150-1250) or better, both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas)
Supply, Installation, Testing & Commissioning of 240V, 4 Way Fixed Speed type Cassette Air-conditioner machine, having Cooling Capacity range (8.72 KW - 8.80 KW), with fixed speed Rotary / Scroll compressor, LCD remote & all other accessories, Refrigerant gas R 32 / R 410A, Air flow range CFM (700-1200), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 48 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas)
Supply, Installation, Testing & Commissioning of 240V, 4 Way Fixed Speed type Cassette Air-conditioner machine, having Cooling Capacity range (6.3 KW - 7.03 KW), with fixed speed Rotary / Scroll compressor, LCD remote & all other accessories, Refrigerant gas R 32 / R 410A, Air flow range CFM (470-800), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 48 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas)
SITC OF CONTROL / COMMUNICATION CABLING
Supply, Installation, Testing & Commissioning of 4C x 2.5 sqmm copper flexible power / control / communication cabling alongwith SITC of precision make pvc pipe between indoor and outdoor units.
SITC OF REFRIGERANT PIPING
Supply, installation, testing & commissioning of copper refrigeration pipe line for liquid and Suction line including vaccumiazation and Nitrogen of testing of following nominal size of soft drawn copper refrigerent piping for Package/ Ductable/ Concealed Split/ Room AC system, complete with fittings with adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XLPE class - O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 9mm. thickness for suction and liquid lines, all accessories as per specification etc. as required & as per direction of EIC with proper mending good damages to original finish. Mk. of Cu pipe - Rajco/ Ryoku/ Mandev/ Nippon Mk. of Nitrile Rubber Insulation - Aeroflex/ K-flex/ Accroflex/ Armacell.
15.88 mm O.D. (Thickness : 7mm) (Insulation : 9 mm)
12.7 mm O.D. (Thickness : 0.7mm) (Insulation : 9 mm)
9.5 mm O.D. (Thickness : 0.6mm) (Insulation : 9 mm)
6.4 mm O.D. (Thickness : 0.6mm) (Insulation : 9 mm)
Supply, Installation & Commissioning of 50 mm PVC Drain Pipe Line (50 mm OD, HD 1 mm Thick) with Insulation , Support & Bracket and other necessary arragnement for vertical run along the building including necessary scaffolding arrangement etc as per site condition & direction of EIC
Supply, Installation & Commissioning of 25 mm PVC Drain Pipe Line (25 mm OD, HD 1 mm Thick) with Insulation , Support & Bracket for connecting the vertical run drian pipe with outdoor unit including necessary scaffolding arrangement etc as per site condition & direction of EIC.
Supply, fabrication & erection/ fixing of M.S. Angle Structure for making platform for installation of outdoor unit of AC machine incl. drilling holes in angles, welding the joints including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with Vertical & Horizontal angles including supporting angle in each platform in outer edge for transmitting the load centrally through 2 or 3 Nos. Angle inserted into the exiting wall, as adequately required. The entire structure should be fabaricated & safe for ODU maintenance. Area & design of the platform should be as per Machines' Outdoor unit's dimension & load with adequate movement access for maintenance as per direction of EIC. The M.S. Angles of sizes (75 mm x 75 mm x 5 mm) (50 mm x 50 mm x 6 mm) , (40 mm x 40 mm x 6 mm) , (25 mm x 25 mm x 5 mm) minimum and M.S u-channel of 5 mm thick of size (75 mm x 40 mm x 40 mm) may be used for making platform. (Structural design should be approved by E.I.C.)
Suply , Fiting & Fixing in position suspended boxing for return/Supply air arrangement for ducting with frame work of alluminium hollow section of size 50mm X 25 mm (2.0 mm thickness) combined with aluminium corners of size 38 mm X 25 mm X , Suspended by alluminium hollow tube section of size 38 mm X 25 mm, 25mm X 25mm powder coated wall angle with alluminium composite panel of thickness 3.0 mm comprising of protective film , polyester coating primer, alluminium coil , adhesive film , polyethelene core again with one layer adhesive film , alluminium bottom coating and finally service coating as per manufacturer's specification finished with alluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of E.I.C
Supply and installation of trap door of 1600 mm x 600 mm and 9 mm thickness made of aluminium channel & ply wood for IDU maintenance.
Supply and fixing flexible canvass connection for concealed split air-conditioners.
Supply and fixing of Al powder coated continuous Grill (Make- Premier)
Supply and fixing of 1 phase timer control box for controlling AC machines made following accessories with IP - 42/43 protection with front door locking arrangement with all connection on angel iron frame on wall as per instruction of EIC.
a) 2+10 way size double door SPN MCBDB--1 No. (L&T)
b) 240/415V, AC 32A, 2P Power contactor type MNX22-2P (Make-L&T) - 1 No.
c) Daily & weekly programmable basis Digital Timer Switch, min switching time 1 min, 25 ON/OFF programs - 1 no.(L & T Cat no. - 67DDT0)
d) 240/415V, 40A, DP MCB Isolator (Make:Legrand) 1 no
e) 3 way Auto manual toggle switch--1 no.
f) AC ON/OFF indicator - 1 set
g) ON/OFF push button - 1 set.
h) Interconnection by 2.5 sqmm Cu wire -- 3 mtr.
Hiring Charge of Scafolding Arrangements for installation of all the Indoor & Outdoor Units.
TERMS & CONDITIONS
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liability period 1 (One) Year
(Rates should be Quoted inclusive of all taxes & duities and L.W.C. @ 1% as applicable)
ANAMICA ENTERPRISE (BID ID -5696279)
WAVE7 (BID ID -5702118)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .