Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC AOC | |
| 2 | L2₹24.3 L+₹2.0 L (8.92%)Rejected-Finance NO 17 PETER GNANA PRAKASAM NAGAR MARIYAMMAN KOVIL PO THANJAVUR 611501 | 611501 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹25.5 L+₹3.2 L (14.5%)Rejected-Finance 1074 BAGYALAKSHMI STREET VENKATESAPURAM ARAKKONAM 631002 | ARAKKONAM | RANIPET | TAMIL NADU | 631002 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹26.7 L+₹4.4 L (19.7%)Rejected-Finance NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹28.2 L+₹5.9 L (26.4%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
21 Oct 2022, 6:00 pmClosed
GARRISON ENGINEER AIRFORCE THANJAVUR
GARRISON ENGINEER AIRFORCE THANJAVUR
REPAIR MAINTENANCE OF DG SETS AMF PANELS SWITCH GEARS AND ALLIED WORKS AT AFS THANJAVUR
2022_MES_554074_1
8912/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
THANJAVUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER AIRFORCE THANJAVUR
₹52,000
15 Nov 2022
24 Sept 2022
22 Oct 2022
24 Sept 2022
21 Oct 2022
7 Oct 2022
Amount
Annual maintenance including all checks as recommended by the manufacturer for 250 KVA to 630 KVA generator set of Kirloskar/Cummins make once in a period of six months or 250 hrs of run whichever is earlier by authorized / OEM including replacement of engine oil, oil filter fuel filter "O" ring, tappet valve adjustment replacing the tappet gasket water leakage rectification and testing commissioning as recommended by the OEM for smooth running complete all as specified and as directed. and as directed. Note :- (i) Engine oil, fuel filter and oil filter shall be measured and paid separately under relevant items. (ii) The rate quoted by the bidders shall include the rate for minor cosumables like distilled water, greese, nut/bolts during rotine AMC checks.
All as per item No. 1 above but for 125 KVA DG set of Kirloskar / Cumins make.
All as per item No. 1 above but for 100 KVA DG set of Kirloskar/Cumins make.
All as per item No. 1 above but for 82.5 KVA DG set of Kirloskar make.
All as per item No. 1 above but for 62.5 KVA DG set of Kirloskar make.
All as per item No. 1 above but for 45 KVA DG set of Kirloskar make.
All as per item No. 1 above but for 40 KVA DG set of Kirloskar make.
All as per item No. 1 above but for 30 KVA DG set of Kirloskar make.
All as per item No. 1 above but for 15 / 20 / 25 KVA DG set of Kirloskar make.
All as per item No. 1 above but for 7.5 KVA DG set of Kirloskar make.
Dismantling and taking out blocked / choked radiator assembly including dismantling of rubber hose, fan blade and V belt etc feeding the high pressure air mixed with water alternatively and applying cleaning chemical on the surfaces of radiator and cleaning thoroughly, brazing work for leakage and refixing the same in position complete all as specified and as directed. and as directed.
Dismantling and taking out self starter assembly and replacement of wornout spare parts like field coil, armature assembly, solenoid assembly, carbon brush, carbon brush assembly, clutch plate assembly and bushes including servicing and refixing to engine complete suitable for the following sizes of DG sets all as specified and as directed.
125KVA to 250KVA DG Set
62.5 KVA to 100 KVA DG Set
20KVA to 45KVA DG Set
Dismantling and taking out battery charging alternater assembly and replacement of wornout spare parts like field coil, rotor assembly, carbon brush, rectifier assembly and bushes etc including servicing and refixing complete suitable for the following sizes of DG sets all as specified and as directed.
125KVA to 250KVA DG Set
62.5 KVA to 100 KVA DG Set
20KVA to 45KVA DG Set
Dismantling and taking out fuel injector pump assembly and complete overhauling of FIP including replacement of unserviceable parts like rebuild overhauling kit, rebuild seal kit, fuel injector 'O' rings, OEM gaskets, spring gasket injector, valve bearing etc complete suitable for the following sizes of DG sets all as specified and as directed..
125KVA to 250KVA DG Set
62.5KVA to 100 KVA DG Set
20KVA to 45KVA DG Set
Supply and fix in replacement Self starter assembly complete suitable for the following sizes of DG sets all as specified and as directed.
250 to 630KVA DG Set
82.5KVA to 125KVA DG Set
30KVA to 62.5KVA DG Set
Supply and fix in replacement Banded cogged belt (2JAX51-LP-1326) cat part No - 06.032.03.0.00
Supply and fix in replacement V Belt (A-47) 1227 length cat part No - 04.140.01.0.00
Supply and fix in replacement Fuel pipe (7.5, 14x14B, 700 PB) cat part No - 34.151.04.0.00
Supply and fix in replacement Fuel pipe (9.5I.D x 4000L) cat part No - 06.610.03.0.00
Supply and fix in replacement Leak off pipe 1000mm long cat part No - 48.112.01.0.00
Supply and fix in replacement Silencer assembly cat part No - 48.318.10.0.00
Supply and fix in replacement Rubber hose for air intake cat part No - 48.464.02.0.00
Supply and pouring KOEL care super genuine oil Cat part No - 82.050.10.0.20
Supply and pouring KOEL care Genuine coolant premix Cat part No - 82.020.35.1.01
Supply and fixing in replacement 1.1ltr fuel filter kit 7.5KVA to 630KVA cat part No - 48.040.01.0.00 or as per existing size.
Supply and fixing in replacement Lub oil filter element cat part No - 06.040.01.0.00 or as per existing size.
Supply and fixing in replacement of air filter element complete suitable for the following sizes of DG sets all as specified and as directed.
Upto 45 KVA DG Set.
Upto 62.5 KVA to 82.5 KVA DG Set.
Upto 100 KVA to 125 KVA DG Set.
Upto 250 to 630 KVA DG Set.
Supply and fix in replacement of stop solenoid 12V 10 amps single coil 75mm dia cat part No - 02.477.01.0.00
Supply and fix in replacement of stop solenoid 24V 10 amps single coil.
Supply and fix in replacement of generator control unit complete suitable for the following sizes of DG sets all as specified and as directed.
KG541 level-0 cat part No - D8.048.07.0.00
KG934 level-1 cat part No - 2H.894.06.0.00
KG545 level-2 cat part No - DV0.901.13.0.00
Supply and fix in replacement of exhaust fan (450mm) with connector cat part No -D8.079.26.0.00
Supply and fix in replacement Kirloskar green AVR for alternator complete suitable for the following sizes of DG sets all as specified and as directed.
Up to 45 KVA DG Set.
For 62.5 KVA to 125 KVA DG Set.
For 250 to 630 KVA DG Set.
Supply and fix in replacement of 4-20mA lube oil pressure sensor gems make 3100 series cat part No - Dvo.812.11.0.00
Supply and fix in replacement of Fuel level sensor height 225mm cat part No- DV0.802.15.0.00
Supply and fix in replacement of Expantion bellow assembly 3" cat part No - 06.602.10.0.00
Supply and fix in replacement of Thermostat element (74 Deg) WTIL No.DEV358 cat part No - 39.040.09.0.00
Supply and fix in replacement of Nozzle leak off pipe cat part No - 06.819.20.0.00
Supply and fix in replacement of electronic battery charger 12volt DC 10amps NHP make cat part No 02.872.18.0.00.
Supply and fix in replacement electronic battery charger 24volt DC 10amps NHP make cat part No 6H.849.09.0.00.
Dismantling of existing defective Alternator any capacity any make from the foundation, disconnecting the electric connection, coupling pulley, and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with super enamelled solid copper conductor (winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of Alternator complete all as specified and as directed.
Supply and fix in replacement pf ATS (automatic transfer switch) 4 pole (TPN) with enclosure with complete protection 100 amps 415 volts 50 HZ AC supply including mounting arrengement and disconnecting/ connecting electrically with existing cable including matching with existing generator safety unit complete all as per Havells cat part No IHYFCDE100 and as directed.
Supply and fix Battery 12V 180 AH mainteance free complete all as specified and as directed.
Supply and fix Battery 12V 90AH mainteance free complete all as specified and as directed.
Supply and fixing Battery Lead 0.5mtr long.
Supply and fixing Battery terminal as per sample.
Supply & Fix Indicating lamps 240V LED type for indication of RYB Phases including taking down the old unserviceable one.
Material and labour for Servicing /maint /repair of AMF panel by checking and replacing defective relays,timers,single phase preventer,panel control wiring with suitable size power contactor in AMF panel all as specified and as directed. and as directed. Note:- Relays, timers, contactors single phasing preventor will be measured and paid for separately under relevent items.
Supply and fix ion replacement KRB relay card 8 way 20 pin (PCB = relay card - 8 ATS - 12 V DC) cat part No 03.218.13.0.00.
Supply and fix ion replacement ATS relay card 8 way 20 pin (PCB = relay card - 8 KRB - 12 V DC) cat part No 03.218.14.0.00.
Supply and fix in replacement Contactor relay Unit of suitable DG Set 24 Volt DC,
Supply and fix in replacement Contactor relay 9 / 8 pin with base12 Volt DC.
Supply and fix in replacement timer relay, relay assembly 220Volt, 6 Terminals .
Supply and fix in replacement HBC fuse link 160amps complete all as specified and as directed.
Supply and fix in replacement DN open type fuse bases fixed type 160amps complete all as specified and as directed.
Supply and fix in replacement 400amps 3 pole power contactor suitable for 250KVA DG Set AMF panel.
Supply and fix in replacement 250amps 3 pole power contactor suitable for 125KVA DG Set AMF panel.
Supply and fix in replacement 200amps 3 pole power contactor suitable for 82.5KVA to 100KVA DG Set AMF panel.
Supply and fix in replacement 95amps 3 pole power contactor suitable for 30KVA to 62.5KVA DG Set AMF panel.
Supply and fix in replacement single phasing preventor (VMR).
Supply and fix in replacement left / right hand lock with catcher.
M/S. SRI RAMANUJA CONSTRUCTIONS
m/s SRI VALLI ENTERPRISES
D Subramani and Sons
SUPER COOL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .