Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.5 L+₹1,668 (0.15%)Rejected-Finance H NO 1 BLOCK NO 2 SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | L3₹13.1 L+₹1.6 L (13.8%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Highest bid quoted other then L1 | |
| 4 | L4₹13.4 L+₹1.9 L (16.4%)Rejected-Finance 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L4 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹31,300
Closing Date
6 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
PROVN OF CERTAIN SENCTION LBW AND RW WORK IN THE AREA OF AGE E/M UNDER GE SGNR AT MILITARY STATION SRI GANGANAGAR
2021_MES_408940_1
GE SGNR/ TOK-48 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Sri Ganganagar
E Class ab (i) and for un-enlisted, refer NIT para 8.
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹31,300
Yes
18 Feb 2021
2 Jan 2021
8 Feb 2021
2 Jan 2021
6 Feb 2021
9 Jan 2021
60 days
Amount
Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth for foundations of poles, struts, stays etc. or for laying underground cable etc. in soft/loose soil, including getting out bricks complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, exc 1.5 m wide and n. exc 3 m in depth for foundations of poles, struts, stays etc. or for laying underground cable etc. in soft/loose soil, including getting out bricks complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in soft/loose soil complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level n.exc 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
M & L for sand cushioning with dry coarse canal sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
M & L cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate for pole pedestal (PCC) including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing, testing and commissioning cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core complete all as specified and directed by Engr-in-Charge.
Supplying, laying, jointing, testing and commissioning 10 sqmm, 4 core, XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/ paths/ drain/ culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
Supplying, laying, jointing, testing and commissioning 25 sqmm, 4 core, XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/ wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
S&F PVC insulated and FR PVC Round Sheathed, Copper conductor (flexible) industrial cable , 1100Volt , size 2.50 sq mm , conforming to IS 694 for connection of fitting from junction box to Light fitting complete all as specified and directed by Engineer-in-Charge
Supply and installation hot dip galvanised octagonal poles with 155mm bottom & 70 mm top A/F made up of 3 mm thick HT sheet alongwith base plate of size 250x250x16 mm (Door with Hinge) with 4 nos of M24 x 750 mm high 'J' type EN 8 grade foundation bolts along with template with inbuilt junction box having 6 A single pole "B" class mcb complete all as specified and directed by Engineer-in-Charge
S&F of 1.5 m long Hot dip galvanised single arm bracket made up of 40 NB dia GI pipe suitable to mount on pole having top 70 mm A/F complete all as specified and directed by Engineer-in-Charge.
S&F 1.5 m long Hot dip galvanised Double arm bracket (1.5 m long each) made up of 40 NB dia GI pipe suitable to mount on pole having top 70 mm A/F. complete all as specified and directed by Engineer-in-Charge.
S&F 4 pole MCCB 63 Amp with thermal magnetic protection,50 HZ,415 Volt with rupturing capacity 25 KA complete all as specified and directed by Engineer-in-Charge. Make - Legrand cat No.4200 53 or equvilent as approved by GE
Boring of holes under road/pavement/hard standing or any other situation by manual mean and including passing GI pipe 50 mm bore and making good both the ends complete all as specified and directed by Engineer-in-Charge. Note : Pipe and cable will be measured and paid separately
S&F GI pipe 50 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed andinclusive of one primer coat, oneunder coat and one finishing coat of paint complete all as specified and directred by Engineer-in-Charge.
S&F 70 W IP 66 LED security light luminaire comprising of epoxy powder Die-cast aluminium housing with weather proof gasket for lamp & driver compartment with system wattage of 100 W . The LED must be of 120 degree view angle, > 110 lumen/ watt, lumen maintenace > 70% at 50000 hrs, color temperature of 5000-6500K, >70 color rendering and LM 80 test compliance. The driver must be integral APFC and constant current type having THD<10% and power factor >0.95 with short circuit protection, open circuit protection, reverse polarity protection, high voltage protection, protection against 5 kV high surges and comply to IEC 60598-1, IEC 61000-3-2, IEC 61547 including The luminaire must have secondary optics with perfectly matched lens for better light control complete all as specified and directed by Engineer-in-Charge.
S&F 150 W IP 66 LED security light luminaire comprising of epoxy powder Die-cast aluminium housing with weather proof gasket for lamp & driver compartment with system wattage of 150 W . The LED must be of 120 degree view angle, > 110 lumen/ watt, lumen maintenace > 70% at 50000 hrs, color temperature of 5000-6500K, >70 color rendering and LM 80 test compliance. The driver must be integral APFC and constant current type having THD<10% and power factor >0.95 with short circuit protection, open circuit protection, reverse polarity protection, high voltage protection, protection against 5 kV high surges and comply to IEC 60598-1, IEC 61000-3-2, IEC 61547 including PVC insulated three core 1.0 Sqmm FRLS multistranded Copper conductor cable for connection of fitting from gd installed junction box to top hight of pole. The luminaire must have secondary optics with perfectly matched lens for better light control complete all as specified and directed by Engineer-in-Charge.
S & F of Power contactor 16 Amp to 32 Amp with contactor, 3 phase for timer of street light timer support to astronomical type timer /digital type /analog type timer with all accessories complete all as specified and directed by Engineer-in-Charge.
Supply, installation, commissioning and testing water storage heater vertical type of capacity 25 Liters suitable for to operate/function on AC 220V, single phase having heating element of 2KW capacity and high thermal cut-out BEE approved 5 Star rated includinguidng fixed along walls with all fixing material required at site and electric connections with copper cable 3 core and plug top 15A includinguding making good to disturbed surface complete all as specified and directrd by Engineer in charge. Make:- USHA aquagenie 25L/ Havells cat part No GHWAMFSIV025 / crompton: imperial/ Bajaj : Majestry
S & F PVC connections 15 mm size with PTMT nuts of length 600mm suitable for Hot water application complete all as specified and directrd by Engineer in Charge.
S & F gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for GI pipes of size 15 mm bore complete all as specified and directrd by Engineer in charge.
S&F steel water tubing medium grade galvanised 15 mm bore with all fittings and fixed recess in walls and ceilings or laid in floors including making good to disturbed surfaces complete all as specified and directrd by Engineer in charge.
S&F in repair MCB protected Socket -25Amps with plastic box and plug top vertical Din rail mount type suitable to operate at 240V current rating range 25A , 50Hz 1Ph complied IS specificatin 13032 & 8623 complete all as specified and directed by Engineer - in - Charge. (Old switch socket 15 Amp deposit with MES store yard)
S & F RCCB cap 25 Amps with sensivity 30 mA, type'A' double pole in accordance with IS 12640-1 & IEC 61008-1) 240/415, 50Hz with 10kA short circuit withstand capacity including enclosure and other accessories (fixing at vertical DB of control of all points of housing wiring) complete all as specified and directed by Engineer - in - Charge. .
S & F ceiling rose, surface bakelite 65x50 mm three terminals complete all as specified and directed by Engineer - in - Charge.
S&F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engineer - in - Charge
S&F MCB TPN 63 Amp, 10 KA,415 volt complete all as specified and directed by Engineer - in - Charge.
S & F with modification sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TPN 4 ways, 415 Volts, 200 amps bus bar stove enameled suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S&F 15 mm bore bib tap cast copper alloy, with crutch or butterfly handles, screwed down, screwed for iron pipe and fixed complete all as specified and directed by Engineer - in - Charge.
M&L for concealed point wiring complete on independent /combined board with cable 2.5 Sqmm (nominal area) FRLS, PVC insulated multi stranded unsheathed copper conductor including conduit fittings after chasing in wall and making good the disturbed surfaces include sunken iron box, 3 mm thick bakelite sheet cover , pipe hooks elbows, brass screws washers with provision of earth continuity conductor of 2.5 sqmm copper single core PVC FRLS insulated cable controlledbyone switch andconnected to common earth dolly for one socket outlet 3 pin 15 amps complete all as specified and directed by Engineer-in-charge.
M&L for concealed point wiring complete on independent /combined board with cable 1.5 Sqmm (nominal area) FRLS, PVC insulated multi stranded unsheathed copper conductor including conduit fittings after chasing in wall and making good the disturbed surfaces include sunken iron box, 3 mm thick bakelite sheet cover , pipe hooks elbows, brass screws washers with provision of earth continuity conductor of 1.5 sqmm copper single core PVC FRLS insulated cable controlledbyone switch andconnected to common earth dolly for one socket outlet 3 pin 15 amps complete all as specified and directed by Engineer-in-charge.
M&L for Earth continuity conductor or main earthing lead 4mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all asspecified and directed by Engineer - in - Charge.
S&F Exhaust fan with high speed noiseless motor of size 300 mm sweep, heavy duty by grouting both ends in wall upto required length and making hole of suitable size in wall, making good the existing surface and connecting with ceiling roses with and including flexible cable 3 core copper conductor of size 23/.0076 of suitable length with frame. louvers, nuts, bolts etc. including making good disturbed complete all asspecified and directed by Engineer - in - Charge. Make- Crompton/Bajaj/Havell's/Orient
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 32 x 6mm, means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type c1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting book made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore medium grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, and 40mm light grade protection pipe complete all as specified and directed by Engineer-in-Charge.
M&L for in replacement Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth of not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia. by means of bolts, nuts and washers of the earth wire galvanized iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanized iron pipe light grade 40mm dia. up to earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia. GI medium grade of length 2.25 meter and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 6mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Complete all as specified and directed by Engr-in-charge. Notes: - (i) GI strip up to earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 meter away from the outer edge of PCC chamber.
Notes : (i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
Gyan Chand Marothia Engineer Contractor And Suppliers
Singla Electricals
jassal engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .