| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.0 L+₹5.1 L (20.6%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹32.9 L+₹8.0 L (32.2%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹33.7 L+₹8.9 L (35.6%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
16 Jul 2020, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Outsourcing the Resources for Operation and Management of AC Plant and pump House in Tech arad at Air Force Stn Jaisalmer.
2020_MES_354568_1
8673/GE/E8
Open Tender
Miscellaneous Works
Item Rate
335 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹59,000
Yes
23 Jul 2020
20 Jun 2020
18 Jul 2020
20 Jun 2020
16 Jul 2020
1 Jul 2020
Amount
Schedule 'A' Part-I General Note as applicable for serial item No 2.00 & 3.00 of BoQ/Sch 'A' Contractors attention is hereby invited that estimated cost of serial item No 2.00 & 3.00 is Rs. 14,47,200.00 based on prevailing rates of Schedule of Minimum fair wages. Quoted amount against serial item No. 2.00 & 3.00 is less than the amount the work (Estimated of serial item No. 2.00 & 3.00 of BoQ/Sch 'A') then lowest bidder will have to deposit FDR in favour of Accepting Officer within 07 days from financial bid opened difference in Estimated cost & quoted amount of serial item No. 2.00 & 3.00 before evaluation of financial bid for acceptance of tender, failing which lowest tender will not be accepted. FDR submitted at the time of Acceptance of bidder will be realesed only after satisfactory proof of payment of deployed person under the respective serial item No. 2.00 & 3.00 of BoQ.
Manning and Operation of Chilled water type Central Air Conditioning Plant capacity 3x50 TR capacity (02 working and 01 standby) installed at ATC and Package type Air Conditioning Plant (Air cooled) capacity 3x11 TR (02 working and 01 standby) installed at GCA and Air conditioning Plant capacity 3x10 TR (02 working and 01 standby) installed at PAR including (DG Set 500 KVA) Electric Supply installation and Water Supply installation with one operator in three shift each shift of 8 hours for 24 hours continuous operation every day to maintain inside design temperature condition as specified, including Sunday/Holidays with carring out daily maintenance, Daily and weekly check up, Monthly, quarterly and half yearly maintenance as per maintenance schedule, replacement/repairs of consumable parts i.e greasing of motor bearings, gasket, shellacs, rubber insertion sheets, neoprene rings, fues, water seal, cotton waste, kerosene oiI, arrangement of labour and tools for smooth functioning of all Plants, complete all as specified and directed by Engineer-in-Charge.
Manning and Operation of Pump House at UAV (3002 Sqn) including Chiller type Air Conditioning plant (Water cooled) capacity 2x11 TR (01 working and 01 Standby) installed at Base Ops and Air conditioning plant capacity 3x8.5 TR (01 working and 01 Standby) installed at Signal Section and Air conditioning Plant capacity 3x22 TR (02 working and 01 Standby) installed at UAV (3002 Sqn) and Air conditioning Plant capacity 3x22 TR (02 working and 01 Standby) installed at HQ 2260 Sqn with one operator in three shift each shift of 8 hours for 24 hours continuous operation every day of month continuous operation including sundays/holidays in a day to day maint inside design temperature condition as specified, including the maintenance, daily and weekly check up, Monthly, quarterly and half yearly maint as per maint schedule, replacement/repairs consumable parts i.e (i) Greasing of motor bearings (ii) Gasket, shellacs, rubber insertion sheets, neoprene rings, fues, water seal, cotton waste, kerosene oiI (iii) Arrangement of labour and tools for smooth functioning of plants complete all as specified and directed by Engineer-in-Charge
Note for serial item No. 2.00 & 3.00 (Contd....) (i) All installation considered in serial item No. 2.00 & 3.00 shall be operated by one operator in one shift, hence three operator for three shifts. (ii) The timing of operation in shifts shall be decided by the department and same shall be followed by the contractor. (iii) During maintenance & operation of AC Plants and DG Sets, if loss of refrigerant and compressor oil take place due to negligence/ misshandling of plant by the contractor’s operators and the same shall be made good by the contractor and cost for the same shall deemed to included in unit rate quoted by the contractor against respective items of Sch ‘A’. (iv) In the event of failure to achieve specified inside condition for any shift or part thereof due to non operation or by other reasons (Except failure of incoming electric/water supply at AC installations) contractor shall be penalized at double the rates, what quoted for against above respective items of Sch ‘A’ Part-I.
Note for serial item No. 2.00 & 3.00 (Contd....) (v) Unit rates quoted by the contractor shall deemed to be included for three shifts and incase of decrease in shifts, the adjustment of rates shall be done proportionately. Contractor shall provide proper manning to give rest to the deployed person for sunday/holiday. For this purpose contractor shall provide one extra manpower. (vi) Daily attendance shall be marked in attendance register by the JE Concerned attandance shall be checked weekly at least by the EIC and monthly by the GE. (vii) Dos" and Don'ts" standing orders of operating machines maintinance programme shall be displayed in each instalation. (viii) Log book, log sheet shall be filled shift wise.
Note for serial item No. 2.00 & 3.00 (Contd....) (ix) Operator shall be in proper uniform As approved by the GE and cost of uniform shall be included in the rate quoted by the Tenderer. (x) Surrounding area shall be kept clean and tidy.Tool required for cleaning is deemed to be included in the quoted rates by the Tenderer. (xi) Unit rates quoted by the tenderrs shall deem to include for Nuts, bolts, Washers, Lugs, Thimbles, wires, terminal clamps, disttiled water required for efficient and smooth functioning of the equipment with out any extra cost to the Govt.(xii) Tenderer shall arrange insurance to his work men and relevent proofs of the same shall be submitted to the department before commencement of work. The cost for the same is deemed to be included in the rate quoted. (xiii) Absent from duty of operator is not permissible as E&M services essential in nature. However, found penalty will be levied Rs 800.00 per men per shift and recovery from bill shall be done through recovery statement. (xiv) Tenderer shall arrange insurance to his workmen and relevant proofs of the same shall be submitted to department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. The provision of statutory laws relating to minimum wages, EPF, ESI payments shall be strictly adhered to by the contractor. The Contractor shall produce proof of payment of wages, EPF and ESI against the respective workmen while claiming payments, The contractor shall employee deployee ITI holder or 05 years experience and recognized govt institute and produce the documents.
Schedule 'A' Part-II S&F Contactor, 45 Amps with AC coil voltage, 415 volts, 50 Hz, 7.5 KW, 5.00 HP, fixed in existing panel including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed. Make : Siemens Cat Part No. 3TF46 or Legrand/ ABB/S&C.
S&F Contactor, 32 Amps with AC coil voltage, 415 volts, 50 Hz, 15 KW, fixed in existing panel including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed. Make : ABB Cat Part No. 1SBL281074R0010 or Legrand/Seimens/C&S.
S&F Contactor, 12 Amps with AC coil voltage, 415 volts, 50 Hz, 5.5 KW, fixed in existing panel including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed. Make : Cat ABB Part No. 1SBL911074R0010 or Legrand/Seimens/C&S.
S&F MCB, TPN, 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed. Make : Legrand Cat Part No. 4086 80 or Seimens/Havells/ABB
S&F MCB, TPN, 40 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed. Make : Legrand Cat Part No. 4086 81 or Seimens/Havells/ABB
S&F MCB, TPN, 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed. Make : Legrand Cat Part No. 4086 83 or Seimens/Havells/ABB
M&L for dismantling, opening and reassembling after replacement of unserviceable spare parts of Monoblock pump set (Horizontal type) capacity 5 HP, 415 volts including dismantling the pump, replacement of mechanical water seal as bearing and lock etc as required, reconnection, re-fixing in same position, transportation to workshop and back and refixing at site and testing complete all as specified and directed. Notes :- Unit rates quoted by the tenderer shall be deemed to include for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.
S&F 6 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper 1100 Volts grade submersible flat cable fixed to submersible motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed. Make : Havells or equivalant model of Finolex/Polycab.
S&F 4 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper 1100 Volts grade submersible flat cable fixed to submersible motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed. Make : Havells or equivalant model of Finolex/Polycab.
S&F electronic type Single Phase Preventor suitable for 3 Phase, 415 Volt, motor VSP-2/3 of any make and any size complete as per sample including disconnecting & taking down old unserviceable Single Phase Preventor, complete all as specified and directed by Engineer-in-Charge. Make : C&S/Havells/ABB/L&T
S&F in replacement gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 15mm bore pipe line complete all as specified & directed by Engr-in-charge.
S&F MCCB, 3 Pole, 400 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4220 02 or Havells/Siemens/ABB.
S&F MCCB, 3 Pole, 250 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4202 09 or Havells/Siemens/ABB.
S&F MCCB, 3 Pole, 200 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4202 08 or Havells/Siemens/ABB.
S&F MCCB, 3 Pole, 125 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4200 06 or Havells/Siemens/ABB.
S&F MCCB, 3 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4200 05 or Havells/Siemens/ABB
M&L for rewinding of electric motor of capacity 5.0 HP with supper enameled copper winding wire of existing gauge, size and weight with insulating mataerial and reassembling and re-fixing in the same position including dismantling and removing the burnt out copper winding wire and cleaning the slot of stator properly complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of electric motor of capacity 3.0 HP with supper enameled copper winding wire of existing gauge, size and weight with insulating mataerial and reassembling and re-fixing in the same position including dismantling and removing the burnt out copper winding wire and cleaning the slot of stator properly complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of electric motor of capacity 2.0 HP with supper enameled copper winding wire of existing gauge, size and weight with insulating mataerial and reassembling and re-fixing in the same position including dismantling and removing the burnt out copper winding wire and cleaning the slot of stator properly complete all as specified and directed by Engr-in-Charge.
Supply, install, connecting & testing electric driven centrifugal monoblock pump set of capacity 3.0 HP / 2.2 KW, Three Phase, 50 Hz, 415 Volts, Head range 10 to 26 metre with inlet/outlet 65x50mm including necessary fixing arrangement inlcuding taking down old unserviceable pump complete all as directed. Make : Kirlosker Model KDS 325++ or equivalent /CG/Havells
Supply, install, connecting & testing electric driven centrifugal monoblock pump set of capacity 5.0 HP / 3.73 KW, Three Phase, 50 Hz, 415 Volts, Head range 16 to 28 metre with inlet/outlet 80x65mm including necessary fixing arrangement inlcuding taking down old unserviceable pump complete all as directed. Make : Kirlosker Model KDS 527++ or equivalent /CG/Havells
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including dismentling & taking down old unserviceable water tank capacity 500 litre complete as specified in SSR Part-I.
Disconnecting, dismantling & taking down old unserviceable LT Feeder Panel box of any size & capacity with fixtures and Supply, install, testing and commissioning factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK), indoor type, suitable for 415 Volts, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, protection class IP-65, having bus bar chamber with insulated copper bus bars suitable capacity in colour code RYB with 3 phase & neutral installed on insulators. The panel shall be dust and vermin proof, made out of 2mm thick CRCA MS sheet and 50x50x6mm thick angle iron for base frame work. The complete feeder pillar box shall be powder coated inside & outside (of approved shade) including suitable size of copper strip from bus bar to MCCB and internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size but not less than 6 sqmm with proper ferrule & cable gland, front & rear openable with aprons for cable entry with double door shutter including locking arrangement as per manufacturers, all as specified and directed. The scope of work includes supply & fixing of the following :-
Serial item No. 26 (Contd...) Note:- (i) LT panel base frame shall be grouted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate. The base shall be 60cm height from the nearest road level/floor level or as directed. (ii) All incoming MCCB shall be connected through MCCB spreaders with incoming bus bar and incoming cable shall be connected with incoming bus bar. (iii) Drawing of LT Panel shall be got approved well in advance from GE before fabrication of LT Panel. (iv) The quoted rate shall deemed to include supply & provision of 65mm lock with 2 keys. Make of Lock :- Godrej / Harrison / Link. (v) Cost of platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration if required at site (the decision of GE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings and complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 25mm bore, complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 40mm bore with & including all fittings and complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 25mm bore, complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 50mm bore with & including all fittings and complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 25mm bore, complete all as specified and directed.
S&F in replacement gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 50mm bore pipe line complete all as specified & directed by Engr-in-charge.
S&F in replacement gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 40mm bore pipe line complete all as specified & directed by Engr-in-charge.
S&F in replacement gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 25mm bore pipe line complete all as specified & directed by Engr-in-charge.
M&L for Heating rod of capacity 2 KW to 3 KW as per existing for Dehumidifier/ Humidifier complete all as specified and directed .
Supply and filling refrigerant gas R-407c for charging complete all as specified and directed.
Supply and filling refrigerant gas R-22 for charging complete all as specified and directed.
S&F in replacement Temperature meter as per sample complete all as specified and directed.
M&L for finding out the leakage and pressure test with filling N2 gas inside of the condensor and cooling coil of Chiller Package type (Water cooled) AC Plant capacity 11/12.5 TR including dismantling of the same for repair the leakage point by brazing/soldering including taking down and refixing the unit and testing the AC unit complete all as specified.
M&L for Descaling of Condenser unit complete with Descaling Chemical (SCALE2/38249022) including cooling tower complete all as specified and directed by Engr-in-Charge. Note : Three number chillar unit will be considered as one Job)
S&F in repair solenoid valve as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in repair Drier filter complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair cooling tower fins of suitable size as per sample complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of AHU Belt of suitable size as per sample all as specified and directed by Engr-in-Charge. Make : Finner or equivalent.
S&F in replacement of cooling tower Sprinkler as per sample complete all as specified.
Supply and fixing in repair AHU filters 90% upto 5 Micron of suitable size complete all as specified and directed by Engr-in-Charge.
M&L for complete control wiring with complete interlocking of chillers units, condensers, Chillers Pump, Cooling Pump and AHU with Panels including disconnecting & taking down old unserviceable wiring complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of cooling tower Strainer filter as per sample complete all as specified.
S&F in replacement of Dehumidifier thermostate as per sample complete all as specified.
S&F in replacement of Pressure Gauge 4" dial 0-21 Kgs rating complete all as specified.
S&F in repair Blower motor pulley, as per sample as directed by Engineer-in-charge
Supply, installation, commissioning and testing of Compressor scroll type Copper wound working on R-407c, Capacity 11 TR and compressor shall be equipped with sunction and discharge stop valves, sunctions, strainer, oil pump with oil strainer, high pressures switch and safety valves and gauges oil measuring the sunction and discharge pressure and the coil pressure shall be provied.Compressor shall be provided with unloading starting device and crank case heater system shall be provided including taking down old unserviceable compressor complete all as specified and directed. Make : Danfoss Model Number SZ185S4RC or equivalent.
Supply, installation, commissioning and testing Compressor scroll type Copper wound working on R-22, capacity 5.0 TR and compressor shall be equipped with sunction and discharge stop valves, sunctions, strainer, oil pump with oil strainer, high pressures switch and safety valves and gauges oil measuring the sunction and discharge pressure and the coil pressure shall be provied. Compressor shall be provided with unloading starting device and crank case heater system shall be provided including taking down old unserviceable compressor complete all as specified and directed. Make : Copeland Scroll Model Number ZR72KC-TFD-522, Serial No. 03B0903AT or equivalnet of Kirloskar/ELG.
S&F in repair MVPD of current range 5-30 Amp, Auxiliary Supply 230 Volt, 5 Sec Curve MPD complete all as specified and directed by Engr -in-Charge. Make :- Softhard Automation Model - EC/Ser No. 81/2K11-34 or equivalent.
S&F in repair M²VPD of current range 5-30 Amp, Auxiliary Supply 230 Volt, 5 Sec Curve MPD complete all as specified and directed by Engr -in-Charge. Make :- Softhard Automation Model - EC/Ser No. 57/2K11-29 or equivalent.
S&F in repair PLC Controller for 11 TR Chillar unit of range 7/2/3, auxiliary supply 15 VAC complete all as specified and directed by Engr -in-Charge. Make : Softhard Automation Model No. 11 TR/ Scroll V2A/ Ser No. 15/SHAPL/2k 11-38 or equivalent.
M/s Shree Construction Company
M/S SHRI HARI CONSTRUCTION COMPANY
rajesh builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .