| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹31.3 L+₹2.1 L (7.15%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹31.8 L+₹2.5 L (8.70%)Accepted-Finance 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | L3 | Accepted-Finance OK | |
| 4 | L4₹32.2 L+₹3.0 L (10.2%)Accepted-Finance | L4 | Accepted-Finance OK | |
| 5 | L5₹32.5 L+₹3.3 L (11.4%)Accepted-Finance WARD NO 20 BIRLA HOUSE JEDERUA KALA DISTT GWALIOR M P 474006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L5 | Accepted-Finance OK |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
14 Dec 2020, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Morar Cantt Gwalior
86828/GWL/E8 PROVN OF TOILET BLOCK NEAR BLDG NO T-05 JCO MESS AND CERTAIN SANCTIONED WORKS UNDER GE GWALIOR
2020_MES_397588_1
8628/GWL/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Gwalior
As per tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹50,000
Yes
26 Dec 2020
24 Nov 2020
16 Dec 2020
24 Nov 2020
14 Dec 2020
8 Dec 2020
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
M & L for cement concrete in foundations, filling and mass concrete ect type D-2 1:4:8 (using 40mm graded stone aggregate) complete all as specified and as directed.
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in old size bricks in cement mortar 1:6. complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed.
M & L for cement concrete in DPC, type B-0 1:2:4 (using 12.50 mm graded stone aggregate) complete all as specified and as directed.
M &L for hard core of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complet as specified and directed.
M&L for 75 mm thick Cement Concrete PCC 1:4:8 type D2 (Using 40mm geaded stone aggregate) as in sub base complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cm 1:4, complete all as specified and as directed.
M&L for glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including10mm thick rendering in cement morter 1:3 on the other side of lathing complete all as specified and as directed.
M&L for brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in old size bricks in cement mortar 1:4, complete all as specified and as directed.
M&L for 75mm thick cement concrete type C2 1:3:6 using 40mm graded stone aggregate as in plinth protection/Path/paving ect surface even and smooth complete all as specified and as directed.
M&L for machine pressed precast concrete Inter locking paver block any shape and size conforming to IS 15658-2006, 60 mm thickness rubber moulded glossy finish laid with dry over and including 25mm thick well rammed 25mm sand cushion complete all as specified and directed
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
S&F steel ventilater with top hung shutter including hinges steel peg stay complete all as specified and directed
M&L for Reinforced Cement Concrete (Design Mix M-25) (20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for Reinforced Cement Concrete (Design Mix M-25) (20mm graded stone aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for formwork rough finished flat surface to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
M&L for formwork fair finished flat surface to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for mild steel TMT bars 06 mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for 10 mm thick screed bed in cement mortar 1: 4 on concrete surfaces mixed with WPC, surface finished even and smooth W/O using extra cement complete all as specified and as directed. Note :-WPC shall be measured & paid seperately as supply only.
Supply only integral water proofing compound (ISI marked) complete all as specified and as directed.
M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 surface finished even & fair without using extra cement complete all as specified and as directed.
M&L for external plaster 15 mm thick in two layers first layer 10 mm thick in CM 1:6 and second layer of 5 mm thick in CM 1:4 with WPC on brick masonary and PCC block plaster surfaces shall be finished even and fair without using extra cement complete all as specified and as directed.
M & L for 05 mm thick rendering in CM 1:3 in ceiling surfaces ,finished fair and even complete all as specified and as directed
M&L for Preparing of newly plastered surface of wall and including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove all loose scales, and foreign materials scarping down , smoke soot moulds , moss and efflorescent salts treating oil and greasy spots and applying three coat of white wash , complete all as specified and directed.
M&L for applying two coats of exterior emulsion paint new plaster surfaces,white or tinted on wall and including one coats white Birla wall care putty to achive even and fair surfaces complete all as specified and directed.
M & L for prepartion of new steel surfaces ,exc. 10 cm width or girth and applying two coat synthetic enamel paint over one coat of red oxide primer etc complete all as specified and as directed.
S&F for rotational moulded polyethylene water storage tank white colour capacity 500 ltr (cylindrical vertical with closed top ) double layer construction , ISI marked , hoisted and fixed in position, including 20mm bore ball brass valve with polythene float and flynet complete all as specified and directed.
S&F 20 mm dia Gun-metal, globe or gate valves, with iron wheel head , screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F 15 mm GI tubing medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F, 20 mm bore tubes medium grade galvanised with all fitting and fixed to walls and ceiling or laid in floor etc complete all as specified and as directed.
S&F, 110mm bore, PVC (SWR) bends any radius complete all as specified and directed complete all as specified and directed.
S&F, 110mm bore, PVC (SWR) junction single (single T), equal or unequal, provided with access door complete all as specified and directed.
S&F, 75 mm bore, PVC (SWR) bends any radius complete all as specified and directed complete all as specified and directed.
S&F, 75 mm bore, PVC (SWR) junction single (single T), equal or unequal, provided with access door complete all as specified and directed.
S&F, 110 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F, 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall etc. complete all as specified and directed.
S&F, 75mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches, wall or in floors etc complete all as specified and directed.
S& F PVC ( SWR ) floor trap plain with grating including jointng with solvent cement and fixed in repair 75 mm dia outlet complete all as specified and directed.
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
M&L Providing precast cement concrete Type C1 (1:3:6 20 mm graded aggregate) in win- dow or door cills, ntels,bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, Watherings, throat- ing etc. and setting in mortar complete with joints to match complete all as specified and as directed.
S&F, 65 to 100 mm size brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union complete all as specified and directed.
S&F aluminum handles cast type, anodized of 100 mm size complete all as specified and directed.
S&F butt hinges 100mm long medium weight, cold rolled mild steel complete all as specified and directed.
S&F 100 mm long aluminium anodised , barrel tower bolt of extruded section and fixed complete all as specified and directed.
S & F 15mm dia stop valve CP fancy type screwed to unioun or GI pipe etc complete all as specified and as directed.
S&F 15mm dia of fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipr or for brass ferrule and fixed complete all as specified and directed.
S&F vitreous china wash down water closet pan ( pedestal pattern ) EWC white shade with required fixing arrangements and plastic water closet seat black closed pattern with flat bottom and cover complete all as specified and as directed.
S & F PVC Low level flushing cistren 10 Ltr capacety including all fitting such as flush pipe brackets complete all as specified and directed.
S&F for wash hand basin vitreous china (flat back) any size including cutting for and pinning in ends of brackets complete size (550 x 400mm ) complete all as specified and directed.
S &F for 15 mm Pillar taps cast copper alloy with capstan head Chromium Plated screwed down, high pressure with or without lettered ‘HOT’ or ‘COLD’ with long screwed shanks and fly nut screwed for iron pipe and fixed complete all as specified and as directed.
S & F concealed Stop valve cast copper alloy screwed down high pressure with CAPSTON HEAD handle chromium plated with long shank and cup (angular type) screwed both ends for iron pipe 15mm bore or for unions and fixed in repair complete all as specified and as directed.
S&F PVC Connections 15mm size and 450mm lengthcomplete all as specified and directed.
M&L for towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) all as specified and directed.
M&L for soap dish, any type, fixed to plugs with chromium plated brass screws all as specified and directed.
Supply only brass chromium plated waste fitting for wash basins and sinks with inlet and outlet, screwed for pipe or connections and with one cleaning cap, 32mm bore all as specified and directed.
S&F for Vitreous china squatting pan orrissa patteren size 580x440 mm white with integral foot rest with S & P trap complete all as specified and directed.
S&F flushing jet spray for pedestal pattern EWC including 1 mtr long flexible pipe and brass chromium plated nuts etc complete all as spd and directed
M&L for cement concrete bed 1:4:8 type D2 for over and around haunching for to 150 mm dia drain pipes including forming cradles; in complete all as specified and directed.
M&L for 150 mm dia internal bore salt glazed stoneware drain pipes laid in trenches and jointed complete all as specified specified and directed.
Taking down cement or cement plaster incl wall tiles, any description, on brick or stone walls & ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300mm x 200mm x 6mm to 7mm thick, in skirting, dados, risers to steps, etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles, over and including 10mm thick plaster in CM 1:4 complete.
M&L for Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc laid over and including 15mm thick screed in CM 1:4 and 25mm thick PCC type B1 1:2:4 (using 12.50 mm graded stone aggregate), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
S & F, Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (Minimum), with grating and union for discharge pipe incl waste pipe complete all as specified and directed.
S&F for 15 mm Bib tap standard of PTMT any colour screwed, for iron pipe and fixed complete all as specified and directed.
S&F for Cast iron Nahani trap with gratings 75mm dia including jointing to waste pipe fixed in cement type B1 (1:2:4) complete all as specified and directed.
S&F for Aluminium handles, cast type anodised of Size 125mm complete all as specified and directed.
S&F for 300 mm aluminium alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet , cast or extruded sections or cast aluminium alloy complete all as specified and directed.
S&F Anodised aluminium frame for doors , windows , ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified and directed.
S & F anodised aluminium door shutters, aluminium section weighing not less than 0.55 kg/m including necessary jointing cleats, Glazing clips , rubber neoprene packing, handles two numbers in each door, 100mm long brass hinges, 150mm long aluminium tower bolts, anodised aluminium snap beading screws etc including M&L for floor machine and godrej lock in each door complete all as specified and directed.
S&F 5 mm thick tinted glass for aluminium door /windows complete all as specified and directed.
M&L for PCC (1:3:6) type C-2, (using 40 mm graded stone aggregate), 100 mm thick, as in plinth complete all as specified and directed.
S&F for rotational moulded polyethylene water storage tank white colour capacity 1000 ltr (cylindrical vertical with closed top ) double layer construction , ISI marked , hoisted and fixed in position, including 20mm bore ball brass valve with polythene float and flynet complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed soft and loose soil complete all as specified and directed.
M&L for Providing precast cement concrete type B1, 1:2:4 (12.5 mm graded aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame (pre cast frame shall be measured separately) , set in cement mortar 1:4 complete all as apecified and directed.
M&L for Providing, precast cement concrete type B1 1:2:4 (20 mm graded aggregate post , frame, pier caps, posts, boundary pillars, brackets, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar complete with joints to match complete all as apecified and directed.
S&F for framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M&L for 1.25 mm thick mild steel, plain black sheet in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; waters tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed.
S&F, purpose made but hinges conforming to Fe-410-0 or Fe 310-0 suitable for fixing to stone/ concrete door and window frames complete all as specified and directed.
S&F Box type steel windows with side hung shutters (double shutters for glass and gauze) jointed together with and including grills using 12mm square bars @ 10cm C/C as per TD No CEBZ/TD /14/2011 including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welded complete all as specified and as directed. Note:- Glass/gauge shall be measured and paid separately under respective item as suply and fix complete all as specified and as directed.
M&L for vitrified ceramic tiles light colour 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors and skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and icluding 15 mm thick screed bed/plaster in CM 1:4 complete all as specified.
M&L for 15mm thick rendering in cement mortar on fair faces of Sqm brick work or concrete surfaces in cement CM 1:4 and surface finished even and smooth, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks (old size) straight or curved on plan, exc. 6m mean radius built, in CM 1:6 as in manholes, spetic tanks, soakage pits, drain etc in any position complete all as specified and directed
Point wiring with PVC insulated 1.5 sqmm multi stranded FRLS copper conductor cable 1100 volts grade drawn into and including concealed rigid nonmetallic PVC conduit medium grade not less than 19mm (ISI marked) with all conduit fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside) with 2.8 mm thick HYLAM brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators, etc and 1.5 sqmm multi strand copper conductor cable as continuous earthwire complete for the following :-
One light point controlled by one switch.
One fan point controlled by one switch.
One 3 pin socket outlet 5 Amps controlled with one switch on the same board.
One 3 pin socket outlet 5 Amp controlled by one switch on independent board.
All as per item No 1 but with 2.5 sqmm multistrand FRLS copper conductor cable for one 15 Amp socket outlet controlled by one switch on independent board and 1.5 sqmm PVC insulated multi strand copper conductor cable as continous earth wire complete.
S&F Switch piano flush button single pole one way 5 Amp complete. Make : Havells/Cona/Legrand.
S&F Switch socket outlet, 5 Pin, 6 Amp 2 in 1, flush type, universal complete. Make : Havells/Cona/Legrand.
S&F Switch socket combination , 5 Pin, 6 Amp 2 in 1, flush type, universal complete. Make : Havells/Cona/Legrand.
S&F Switch socket combination , 6 Pin, 5/ 16 Amp 5 in 1, flush type, universal complete. Make : Havells/Cona/Legrand.
S&F Ceiling rose 3 terminal/pvc/polycarbonate, isolated body. Make : Havells/Cona/Legrand.
S&F Lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings incl LED Bulb 09W/10W complete. Make of Lamp Holder :- Leader/Legrand/Havells. Make of LED Bulb :- Philips, Wipro, Havells.
S& F of 9/10 W LED 2Ft LED batten including LED tube rod having LED Batten suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with minimum 2.5 KV surge protection. Make :- Wipro, Philips.& Havells.
S&F Ultra bright LED Tubelight fittings complete of 18/20 w incluing req length of 1.5 Sqmm PVC multistranded copper conductor ro electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed. Make of LED fittings :- Philips, Wipro, Havells.
S & F security light fittings better optics for uniform distribution IP 65 protection LED of 30 watt, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of 40 x 6 mm FI, 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqd length of 1.5 Sqmm PVC multistranded copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed. Make of LED fittings :- Philips, Wipro, Havells.
S&F PVC type Wall mounted Ventilating Fans 150 mm sweep BEE 5 star rating energy saving including cutting of wall all as specified and directed by Engr - in - Charge. Make :- Havells/Usha/Bajaj.
Supply & fixing water heater storage type metallic outer body and stainless steel inner container, 25 Ltrs capacity, electric suitable for single phase, 50 Hz, AC Supply, 4 star rating, including all necessary fittings and fixture with minimum 1M of three core 2.5 sqmm twisted copper conductor cable PVC sheated, three pin plug top complete with necessary fittings and fixtures all as specified and directed. Make :- Usha, Havells, Crompton.
M&L for sub main wiring with 2 runx 6 Sqmm + 4 sqmm earth wire single core PVC insulated cable unseathed multistranded copper conductor LT 1100 volts grade FRLS cable IS-694 (ISI marked with valid CML No ) drawn in & icluding PVC conduit of dia not less than 25mm in concealed (ISI marked with valide CML No ) including its all fittings/accessoreis with one run single core copper cable 4 sqmm multistranded conductor (ISI marked with valide CML No) colour code as a earth continuity and connecting upto DB with suitable lugs all as specifed and directed. Make of Conduit & wire : Anchor, Finolex, Polycab.
S&F Sheet metal enclosure MCB DB, double door , 4 way TPN, 415 volts with 200 Amps rated bus bar with blanking plates wherever required and I.P. 20 degree protection complete. Make : Legrand,C&S(Electric),Schneider
S&F, in repair, MCB DB, sheet metal enclosures double door SPN 8 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F, MCB TPN 415 Volts 32 to 63 Amps, including connection with suitable size copper lugs in repair complete all as specified and directed. Make:- HPL, Havells, C&S(Electric), MDC
S&F, MCB SPN 40 to 63 Amps, 240 volts 'B' series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed.
S&F, MCB SP 240 volts, 6 to 32 Amps, 'B' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed.
S&F sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket with and including one single pole MCB 20. Amps, 240 volts,10 KA complete all as specified and directed. Make :- Legrand/Siemens/Scheider.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area of following 35 Sqmm 3.5 Core.
Excavation in trenches n exc. 1.5 m wide and n' exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete.
Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete.
Bricks, old size sub class `B' laid in trenches with width wise along the alignment of the cable as protection complete.
S&F tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe etc complete all as specified and directed.
S&F MCB single pole and neutral 240 volts, 25 to 40 Amps complete. Make :- Schneider, Havells, Legrand.
S&F Sheet metal enclosure MCB DB, single door , 04 way SPN, 240 volts with 200 Amps rated bus bar with blanking plates wherever required and I.P. 20 degree protection complete. Make :- Schneider, Havells, Legrand.
Supplying & fixing twin core PVC insulated with aluminium conductor single strained cable 1100 volts grade of size 10 Sqmm.
M & L for house service bracket (hook type) complete with 3 mtr long GI pipe 40 mm dia GI pipe Med grade two Nos 90 degree bends MS hook and stay or guy complete incl taking down old unsv one all as specified and directed.
Supply and Fixing wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum BEE 5 star rating of capacity 1.5 TR Make : Voltas/LG/Samsung
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilizer at 230 V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and directed. Make - Blue bird/Microtek/V Guard.
S&F sheet metal earth plug, socket, single pole and neutral with single pole MCB 20. Amps 240 volts in repairs complete all as specified and directed. Make : - HAVELL's Cat Part No DPSSN020 or equivalent make Legrand/IndoAsian fuse Gear.
Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 volts grade, 4 Sqmm size with multi stranded copper conductor (ISI marked with valid CML No), drawn in and including surface mounted non metallic rigid PVC conduit (ISI marked with valid CML No) not less than 20mm dia with all accessories including PVC insulated un sheathed 2.5 Sqmm cable with multistranded copper conductor (ISI marked with valid CML No) as connected to earth with dolly complete all as specified and as directed (Cutting of wall and making good disturbed surface of wall shall be measured & paid sepertely,Make of cable : Finolex, Plaza, Havells, Polycab & Make of conduit : Sri Nath pipes/Anchor/Finolex/ Polycab.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core 6 Sqmm cable flat or circular complete all as specified and directed.
M/S DHARMENFRA SINGH TOMAR
M/S AUTOMATION AND SWITCHGEAR CONTROL
lodhi builders
J.N.R. Engineers and Builders
m/s anil traders
YASH DEVELOPERS AND CONSTRUCTION COMPANY
M/s Mahesh Engineering Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .