Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 CrAccepted-AOC | ₹21.0 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹22.8 CrRejected-Finance | ₹22.8 Cr | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹25.5 CrRejected-Finance | ₹25.5 Cr | L3 | Rejected-Finance Not Being Lowest |
Tender Value
₹20.8 Cr
EMD Value
₹15 L
Closing Date
4 Nov 2023, 6:00 pmClosed
Chief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone Spread Eagle Falls Shillong 793011
PROVN OF TECH ACCN OF CENTRAL STERILE SERVICES DEPARTMENT OT ICU LABOUR ROOM 20 BEDDED ACUTE MALE and FEMALE WARD EACH AT MILITARY HOSPITAL SHILLONG UNDER GE SHILLONG
2023_MES_614387_1
CESZ/SHL/ OF 2023-24
Open Tender
Civil Works
547 days
Shillong
As per NIT
2 documents required · 2 mandatory
₹3,000
GE Shillong
₹15 L
Yes
24 Nov 2023
18 Aug 2023
6 Nov 2023
18 Aug 2023
4 Nov 2023
23 Oct 2023
19 Aug 2023 - 30 Aug 2023
Amount
Note:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and General conditions of contracts before entry/quoting the rates.
Lumpsum price workedout by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II.
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III.
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATIONS as listed in Schedule ‘A’ Part-IV.
Lumpsum price worked out by the tenderer for ROADS / PATH / CULVERT / FOOTPATH as listed in Schedule ‘A’ Part-V.
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI.
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII.
Lumpsum price worked out by the tenderer for CHAIN LINK FENCING/GATE as listed in Schedule ‘A’ Part-VIII.
Lumpsum price worked out by the tenderer for RETAINING WALL as listed in Schedule ‘A’ Part-IX.
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-X.
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-XI.
Lumpsum price worked out by the tenderer for FIRE FIGHTING SYSTEM as listed in Schedule ‘A’ Part-XII.
Lumpsum price worked out by the tenderer for LIFT as listed in Schedule ‘A’ Part-XIII.
Lumpsum price worked out by the tenderer for AIR CONDITIONING AND HEATING SYSTEM as listed in Schedule ‘A’ Part-XIV.
Lumpsum price worked out by the tenderer for SOLAR WATER HEATER as listed in Schedule ‘A’ Part-XV.
Lumpsum price worked out by the tenderer for DEMOLITION/DISMANTLING/TAKING DOWN as listed in Schedule ‘A’ Part-XVI.
Lumpsum price worked out by the tenderer for DG SET as listed in Schedule ‘A’ Part-XVII.
Sch 'A' Sec-XVIII (Miscellaneous Items)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Supply and installation of Effluent Treatment Plant of 20,KLD capacity consisting of Fiber glass reinforced Plastic (FRP) tank made by filament winding process from suitable polyester resin and glass fiber of the tank with suitable polyester resin and fiber glass to make tank suitable for underground application process variation. The tank to have three zones – first zone to work as anaerobic septic zone created with suitable partition of FRP; second zone to be created by partition of FRP with advanced fab media with a surface area to volume ratio of minimum of 400 Sq. Mtr / Cubic meter suitably encased free movement of the media within fixed space created by the net; the third zone to work as sedimentation zone in the remainder area of the tank. Aerobic zone have Air Blowers -2Nos(one working+ 1 stand by) installed for providing air flow coarse aeration in the zone for speedy reduction of BOD. Effluent transfer pump 2 HP-2nos(one working+ 1 stnd by) for pumping the activated sludge back to the anaerobic zone by way of PVC pipes,Dosing system with pump-3set, filter feed pump -2nos(one working+ 1 stnd by), etc. The whole plant to be controlled by automatic control panel made from sheet moulded compound including the following Items:- Supply and fixing Motor control panel cubical type of suitable size, 415 volt, factory made dust proof vermin proof (Kiosik type) for out door use made out of CRCA sheet 3.15 mm thick exept inner sheath OG 2 mm powder coated, machinepressed, both side opening in two halves with provision of rubber beading and locking system, inciuding aluminium bus bar of 100 Amp capacity,4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers each MCCB/ cubical switch shall have be independent opening, panel should be monthed on angle iron frame and legs (vertcal height of legs not less than 30 cm exept in PCC) made from angle of size 50x50x5 mm, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer legs grouted in PCC(1:3:6) type B-2(using 40 mm graded stone aggregate)complete including all connection/ control wiring with suitable size of copper conductor cable ,including danger notice sticker ,comprising the following accessory including testing complete all as specified
ITEM NO 18.01 Cont (a) MCCB 63Amp 25 kA, 4 pole, - 01 No. (Incomer) (b) MCB 16 Amp 10 kA, TP, -02 Nos. (Outgoing blower) (c) MCB 6 Amp 10 kA, TP, - 7 Nos. (Outgoing for pump) (d) Soft Starter for 0.5 hp Motor - 03Nos (e) Soft Starter for 1hp Motor - 04Nos (f) Soft starter for 2 hp blower-02Nos (g) Single phase preventer-9 Nos (h)capacitor bank 1x5 kvar rated voltage 450V AC frequency 50HZ,rated current 6.4A, rectangular type. -1Nos k) R,Y,B Indicators -01 Set (l) Digital Amp meter (0-100) Amp incl necessary CTs (set of three) - 1sets (m) Digital volt meter (0-500V)-01 No
Supply ,installing,testing and commissioning of bar Screen Unit 500 x 500 mm size consisting of 2. Nos. of bar screens made of 30x10 mm Strips spaced at a center to center distance of 30 mm and fixed at an angle of 60 degrees to horizontal, all bar strips firmly welded to single frame of 50x6x6 Mm thick as shown in drawings, entire bar screen unit is made in stainless steel 304 grade material and bolted to side walls, using anchor bolts of SS 304 material in the middle of bar Screen chamber complete all as specified and directed.
Construction of VALVE PIT TYPE 'A' of brick Masonry and of size 60 cm x 60 cm x60 cm (inner dimension) with all fittings and fixtures complete all as specified and as shown on drawing No. TD/EM/6 Sheet 1/2
Supply, install, testing and commissioning of centrifugal pump set mono block, electrically driven 3 ph, 415 volts, 'F' class insulation IP 55 protection completed with pumpset MS metal body, CI impeller with discharge 150 LPM & minimum head 30 mtr, suction and delivery size 50x50 mm including base frame and brass metal body footvalve 50 mm dia ISI mark dia, pressure guage 0 to 7 Kg/cm2, necessary electrical connections from starter to motor with 10 sqm copper conductor including foundations as per manufactures specifications complete all as specified and directed .( 01 Working & 01 Stand by)
Supply and installation of 11KV Compact substation with non extensible RMU consisting of 1No manually operated 11KV/630 Amps VCB in SF6 insulated stainless enclosure with of 11 KV, single phase, indoor resin cast CT/PT combination with CT of ratio as recommended by OEM, class 1.0 / 5P10, burden 15 VA and PT of ratio 11 KV/rt3/110V/rt3/110V/ rt3, class 0.5-3, Burden 50 VA - 50 VA including other accessories & connecting with IDMT Relay for fault detection and short Ckt protection ,HT cable/Bus bar,1 No of transformer 500KVA,11 KV/433 CRT dry type & associated LT devices with following accessorie,(i) RYB Phase indicator LED type (ii) LT ACB 800 amps 50KA- 01 Nos (for outgoing (iii) MCB SP 6 amps-4 Nos (iv) Trivector meter alongwith suitable HT CTs & PTs and their connections-01 Set Bus Bars 01 set (04 Nos):Electrolytic high conductivity copper three phase and neutral busbars rated at 1000 Amps of length as required at site as incoming & outgoing busbar on LT side, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints and complete enclosure shall be as per IEC-60298 and protection grade for HT/ LT switch compartment shall be IP-55 and protection grade for transformer compartment shall be minimum IP-23 and each compartment shall be provided with door and pad locking arrangement and each compartment shall be provided with illumination lamp with door operated switch complete with standard fitting complete all as specified and directed.
Supply & fixing 25W LED street light fitting with pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection including GI bracket made up with 32 mm dia medium grade GI pipe ( min 1.5 mtr length) with MS clamps of suitable dia made up with 25x 6 mm MS flat (03 Nos) and nut bolts etc complete all as specified and as directed
Supply and fix factory made IP-65(Dust and power jet proff according to IECc60529)transparent street light junction box size 155x92H made of high quality polycarbonate(shock proof,rust free,corrision free acid and chemical resistant,fire retardant,fire retardant having high impact 9IK 08) totally insulated,UV resistant) having high grade gasket made of polyurethane with two cable gland for cable size 10sqmm etc and fixing on pole with MS flat iron of size 20x3mm with necessary nut & bolts complete all as specified and directed.
M& L for sand cushioning in trenches for protection of under ground cable provided in layers of sand as 8 cm before laying the cable and 15 cm deep after laying cable complete all as specified and directed. Note : Punned thickness shall be measured and paid.
Supply and fix cable route indicator oval shaped of size 200x150x6mm thick made out of Cast Iron with letter embossed as "LT UG Cable" fixed to 25x25x6mm mild steel angle iron 450mm long embedded in PCC block of size 200x200x200mm in PCC 1:3:6 type C1 using 20mm graded stone aggregate and including painting two coats of synthetic enamel paint over a coat of redoxide zinc chrome premier on exposed steel surfaces complete all as specified and as directed
Supply, install, test & commissioning of factory fabricated indoor Main LT Panel panel weather & vermin proof IP 65 Class double door totally enclosed on 50 mm x50 mmx 6 mm thick angle iron frame, Cubicle modular made out of 2 mm thick CRCA sheet with epoxy powder coated dip coated primer, manual type control rust proof Siemens gray structural RAL 7032, sheet for mounting MCB/MCCB's and other accessories earth bus strip etc & with all interconnections, risers, internal wiring, labels, terminal blocks etc. complete as required and connection with existing PVC/XLPE insulated cable with provision of joints, lugs, gland, etc all as specified & directed and consisting of the following including necessary PCC work for foundation excavation & earthwork etc complete., suitable for operation 3 Phase, 4 wire, 440 volt, 50 Hz, AC system of panel size suitable for housing the following items as per IS standard & consisting of following accessories:- Incoming:(a) 01 Nos. of 800 Amp 4P ACB of 65 KA Breaking capacity with single phase to ground fault relay . (b)Metering for incoming:Digital VAF + PF meter, Cl 1 flush mounting type with CTs as required. (c) RYB Phase indicator LED type with protection MCB - 01 Set , (d) Bus Bars:Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 800 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. (e) On load change over switch 415 volts, 4 pole, 800 Amps capacity-01 Nos Outgoing : (a) 01 No. 630A TPN MCCB of 50 KA breaking capacity. (b)1Nos 200 A TPN MCCB of 36 KA breaking capacity (c)01Nos 160A. TPN MCCB of 26 KA breaking capacity . (d)01Nos 32A. TPN MCCB of 16 KA breaking capacity. (e)11Nos 6-32A. MCB of 10 KA breaking capacity. (f)01Nos 100A. TPN MCCB of 26 KA breaking capacity . (g) 02Nos 16A. TPN MCCB of 16 KA breaking capacity . Note: The MCCBs of breaking capacity 25 KA and above shall be Ics=100% Icu
Supply, install, test and commisioning of factory fabricated LT panel, outdoor type mounted on 50 mm x 50 mm x 6 mm thick angle iron frame, cubicle modular made out of 3.15 mm thick CRCA sheet with epoxy powder coated after dip coated primer manual type control, rust proof Siemens grey, structural RAL 7032, sheet for mounting MCB/MCCB's and other accessories, earth bus strip etc & connection with existing PVC/XLPE insulated cable with provision of joints Lugs gland etc all as specified & directed and consisting of the following including necessary PCC work for foundation excavation & earthwork etc complete, suitable for operation 3 Phase, 4 wire, 440 volt, 50 Hz, AC system of panel size suitable for housing the following items as per IS standard & consisting of following accessories :- (incoming) (a) Aluminium bus bar 300 Amps rating, 4 Pole, 415 volts, TPN, colour coated with PVC/epoxy insulation & mounted insulator - 1 set of TPN (RYBN) (b) RYB Phase indicator LED type with protection MCB - 1 set (c) CRCA sheet chamber for bus bar, MCCB/ MCB, Meter etc complete (d) MCCB 4 Pole with thermal magnetic release, 200 Amps TPN, 36 KA, 415 volt, AC, 50 Hz with necessary connection control wiring & accessories etc complete all as specifed & directed -1 No (e) MCCB, 415 Volts, 63 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 5No (outgoing) (a) MCB SP, 415 Volts, 6-32 Amps, 10 KA, AC, 50 Hz, - 8 No (b) Digital multifunction meter with all electrical parameters like V,A,F,PF,KW,KVA,KWh, etc. - 1 No. (c) Control wiring with FR grade PVC insulated copper cable of suitable rating with necessary CTs & locking arrangement with DC panel lock Note : Panel shall be IP 65 Class CPRI approved and contractor shall submit CPRI Test Certificate to the Engineer-in-Charge Note: The MCCBs of breaking capacity 25 KA and above shall be Ics=100% Icu
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI wire 4mm dia as earthing lead connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layers complete as shown in electrical plate No. 3 of SSR Part-I all as specified and directed .
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32 x 6mm as earthing lead connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layers complete as shown in electrical plate No. 3 of SSR Part-I all as specified and directed.
Supply and fix UPS for 30 min back up three phase Ac input 300to450V & single phase AC output Voltage 230V, 50 Hz +1% of capacity 15KVA with adequate Capacity of Battery as recommended by OEM of UPS manufacturer complete all as specified and directed .
Supply and fix Air Cushioning tank (Air vessel) 250mm diaX 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia Brass air valves (ball type),20mm dia stop valve, pressure guage with brass stop cock,nipple tees elbows complete all as specified and directed .
Providing and Fixing suitable C.I air release single valve (Zoloto/ZIP) of 20mm dia including necessary support and painting with two coats of enamel paint over a coat of primer etc for wet riser termination complete all as specified and directed .
Supply and fix Gun metal fire brigade inlet connection 2 way to external fire hydradant main consisiting of two nos 63mm dia instantaneous type male coupling with built in valves and 150mm dia,flanged outlet complete all as specified and directed .
S&F fireman switch sign-12"x4", Model No FS-124433 complete all as specified and directed .
Providing and fixing bronze orifice with 12mm thick disc with tag on plate mentioning dia of orifice for sprinkler system to control the pressure including rubber gasket packing ,bolts nuts,washers complete all as specified and directed .
S&F of ISI marked IS:15683 fire extinguisher stored pressure ABC powder type 9 kg capacity with initial charge valve pressure guage discharge horn with nozzle wall fixing bracket etc complete all as specified and directed.
S&F of ISI marked IS:15683 fire extinguisher carbon di oxide(CO2)type4.5 kg capacity with initial charge valve pressure guage discharge horn with nozzle wall fixing bracket etc complete all as specified and directed.
S&F of ISI marked IS:15683 fire extinguisher mechanical foam type(AFFF) 9 LTR capacity with initial charge valve bend with ABC horn,handle wall fixing bracket etc complete all as specified and directed.
Supply & Fix Zonal Annunciator panel conforming to IS:2189 with battery backup with built in Charger ,16X1 Line Dot matrix LCD display Operating temerature 0 to 40 degree c ,AC power 220V ,50HZ,and stand by:24V DC ,Operating humidity ;95%(non-Condensing) including control wiring using suitable size of PVC insulated copper conductor complete all as specified and directed.
S&F testing and Commissioning 100 mm dia CI double flanged alarm valve assembly with alarm gong,consisting of installation stop valve ,alarm valve drain 50mm dia and 15mm dia test valve,pressure guage on inlet and outlet with alarm motor and gong,alarm check valve clack with padlock and stop drain plug ,alarm stop valve and strainer including making inlet /outlet connection by providing necessary nuts,bolts, gasket (6mm thick) complete all as specified and directed.
Supply and fixing in position drain/test assembly comprised of 2 nos 50mm dia brass tested heavy duty ball valve with screwed ends confirming to IS 554 with ISI mark, including necessary GI 'C' class pipe,union (1nos & sight glass fitting etc.) complete all as specified and directed.
Providing and Fixing paddle type flow switch on pipes with welded socket including stainless steel paddle suitable to pipe dia 100mm to 25mm testing and commissioning etc complete all as specified and directed.
M&L Wiring twin core PVC sheathed of size 1.5 sqmm PVC insulated copper cable HRFR-LSH with ISI complete all as specified. and directed.
Supply and fixing Triple dome LED light to be suspended from the ceiling,microprocessor controlled technology,dia should be 65-70cm ,power supply 100-230V AC supply, also having battery backup for 30min(3kva) ,axial rotation of 360degree .(For major OT having lux level >140000) complete all as specified and directed.
Supply and fixing Triple dome LED light to be suspended from the ceiling,microprocessor controlled technology,dia should be 65-70cm ,power supply 100-230V AC supply, also having battery backup for 30min(3kva) ,axial rotation of 360degree .(For major OT having lux level >70000) complete all as specified and directed.
Supply, installation, testing and commissioning of silent type Diesel Engine driven Generating set of capacity 500 KVA ISI marked,Water cooled type,1500 RPM 415 volts, 3 phase 4 wire (Engine as per IS: 10001/10002 and alternator as per IS: 13364) complete with foundation as per manufacturer's recommendation, standard AMF panel with necessary protection and meters including sound proof canopy of capacity 500 KVA including retrofiting for emmision control device (RECD) for emission control to meet the latest CPCB norms complete including the following: - (a) ENGINE Diesel engine prime mover of suitable BHP to drive 500 KVA alternator with the following: - (i) Fuel level indicator (ii) Fuel tank of suitable capacity for storing minimum 8 hrs consumption capacity at 75% load. (iii) Fuel inlet arrangement from outside the acoustic enclosure with locking arrangement. (iv) Robust, MS base frame with anti vibration damper pads (v) Continuous 10% overload capacity in every 12 Hrs running. (vi) Self starting with and including suitable maintenance free battery of suitable AH rating as per OEM including charging circuit. (vii) Mechanical or Electronic governor as per OEM. (b) ALTERNATOR 500 KVA at 0.8 PF (lag), 415 volt, 3 phase, 4 wire, 50 Hz, 1500 RPM copper wound with the following: - (i) Self regulated brushless self excitation. (ii) Automatic voltage regulator with band of voltage regulation: + 2.5% of rated voltage.
Material and labour for 12mm copper pipe 0.9mm thick medical grade En-13348 DHP with installation, welding connector along with paint complete all as specified and directed.
Material and labour for 15mm copper pipe 0.9mm thick medical grade En-13348 DHP with installation, welding connector along with paint complete all as specified and directed.
Material and labour for 22mm copper pipe 0.9mm thick medical grade En-13348 DHP with installation, welding connector along with paint complete all as specified and directed.
Material and labour for 28mm copper pipe 0.9mm thick medical grade En-13348 DHP with installation, welding connector along with paint complete all as specified and directed.
Material and labour for 35mm copper pipe 1.2mm thick medical grade En-13348 DHP with installation, welding connector along with paint complete all as specified and directed.
Material and labour for 42mm copper pipe 1.2mm thick medical grade En-13348 DHP with installation, welding connector along with paint complete all as specified and directed.
Material and labour for ISOLATION VALVES 42mm outer dia having property of 90 degree turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance complete all as specified and directed Note: ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction.
Material and labour for ISOLATION VALVES 35mm outer dia having property of 90 degree turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance complete all as specified and directed Note: ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction.
Material and labour for ISOLATION VALVES 28mm outer dia having property of 90 degree turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance complete all as specified and directed Note: ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction.
Material and labour for ISOLATION VALVES 22mm outer dia having property of 90 degree turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance complete all as specified and directed Note: ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction.
Material and labour for ISOLATION VALVES 15mm outer dia having property of 90 degree turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance complete all as specified and directed Note: ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction.
Material and labour for ISOLATION VALVES 12mm outer dia having property of 90 degree turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance complete all as specified and directed Note: ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction.
M&L for gas Zonal Valve box Two Gas services An Zonal area valve box should have bellow spec. Wall mounted M.S. box with powder coated & lockable, front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position complete all as specified and directed
M&L for gas Zonal Valve box Three Gas services An Zonal area valve box should have bellow spec. Wall mounted M.S. box with powder coated & lockable, front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position complete all as specified and directed
M&L for gas Zonal Valve box Four Gas services An Zonal area valve box should have bellow spec. Wall mounted M.S. box with powder coated & lockable, front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position complete all as specified and directed
M&L for gas Zonal Valve box FIVE Gas services An Zonal area valve box should have bellow spec. Wall mounted M.S. box with powder coated & lockable, front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position complete all as specified and directed
M&L for Gas outlet self selling type complete all as specified and directed
M&L for Gas outlet point (for oxygen) complete all as specified and directed.
M&L for Gas outlet point (for compressed air) complete all as specified and directed.
M&L for Gas outlet point (for vaccum ) complete all as specified and directed.
M&L for Gas outlet point (for nitrous oxide) complete all as specified and directed.
M&L for Oxygen gas Flow meter with Humidifier Bottle: • Flow meter should be Backpressure Compensated. • Flow meter should be accurate gas flow measurement and control within a range of 0-15 liters per minute. • It should meet strict precision and durability standards. • Flow meter body should be made of brass material. • Flow tube and shroud components should be made of clear, impact resistant polycarbonate. • The humidifier bottle should be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. The humidifier should have built in safety valve complete all as specified and directed.
M&L for Single piece wall mounted suction collection & regulation unit. With jar capacity of 600ml each shall be provided at each of the bed side. Jars are should be made of autoclavable materials. The units shall be clamped to the wall using suitable clamps complete all as specified and directed.
M&L for Analouge Alarm for Three Gas Systems:- Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors complete all as specified and directed.
M&L for Digital Area Alarm for Three Gas Systems:- Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors complete all as specified and directed.
M&L for Semi Automatic control panel for Nitrous Oxide. Semi automatic control panels are should be highly test designed for various control functions required during supply of oxygen through the manifold unit. Should be Enclosed in a metal cabinet. This semi automatic control panel should be highly efficient in triggering the signal for the Reserve system to go operational in case primary and secondary system fails in emergency. This panel is normally connected in a permanent mode and change over is semi automatic. The Semi automatic control should have bellow features:- Control panel cover made of M.S.duly powder coated. Easy maintenance. Highly reliable. Designed for safety and continuity of flow supply at a constant pressure. Pressure gauge facility to indicate the gas pressure of each header and pipe line distribution pressure. Capable to provide a distribution flow rate in excess of 1500LPM. Incorporation of safety puncture in case pressure exceeds 100Psi. complete all as specified and directed.
M&L for Fully Automatic Oxygen Control Panel: The fully automatic control panel should be the following features: • Should be enclosed in a metal cabinet with a hinged cover. The side covers of the panel should be made of fiberglass. • Panel cover should be fitted with a lock to prevent unauthorized access can be swung open for maintenance. • Should be Fully Automatic Changeover operation and no manual action • The service gas should pneumatically operate gas change over system. • Delivery of gas through control panel should not be dependent on electricity. • Should be capable of delivering very high flow rate not less than 1300 litrs per minute at delivery pressure.• Should have Visual indication of the • state of the manifold by 3 gauges within the control panel, which should be clearly visible through the transparent cover. • Should have Audio – visual alarm indication for changeover of empty cylinder bank to filled cylinder bank. • Built in transformer to ensure safe operation by low voltage. • Microprocessor based alarm signal control with high ‘db’ Siren system complete all as specified and directed.
M&L for vaccum theater suction unit aluminium powder coated trolley with side rotation switch complete all as specified and directed.
M&L for Vaccum pump 2HP Base mounted with three phase (min 180 ltr) complete all as specified and directed.
M&L for Vaccum pump 2HP Base mounted with three phase(280ltr) complete all as specified and directed.
M&L for Vaccum pump 2HP Base mounted with three phase(500ltr) complete all as specified and directed.
M&L for Vaccum pump 3HP Base mounted with three phase (min 180 ltr) complete all as specified and directed.
M&L for Vaccum pump 3HP Base mounted with three phase(280ltr) complete all as specified and directed.
M&L for Vaccum pump 3HP Base mounted with three phase(500ltr) complete all as specified and directed.
M&L for Vaccum pump 5HP Base mounted with three phase (min 180 ltr) complete all as specified and directed.
M&L for Vaccum pump 5HP Base mounted with three phase(280ltr) complete all as specified and directed.
M&L for Vaccum pump 5HP Base mounted with three phase(500ltr) complete all as specified and directed.
M&L for Vaccum pump 7.5HP Base mounted with three phase complete all as specified and directed.
M&L for Vaccum pump 10HP Base mounted with three phase complete all as specified and directed.
M&L for Air compressor 1HP 40L Single stage with three phase complete all as specified and directed.
M&L for Air compressor 1HP 40L Single stage with single phase complete all as specified and directed.
M&L for Air compressor 1HP 90L Single stage with three phase complete all as specified and directed.
M&L for Air compressor 1HP 90L Single stage with single phase complete all as specified and directed.
M&L for Air compressor 2HP 90L Single stage with three phase complete all as specified and directed.
M&L for Air compressor 2HP 90L Single stage with single phase complete all as specified and directed.
M&L for Air compressor 2HP 180L Single stage with three phase complete all as specified and directed.
M&L for Air compressor 2HP 180L Single stage with single phase complete all as specified and directed.
M&L for Air compressor 3HP 90L Single stage with three phase complete all as specified and directed.
M&L for Air compressor 3HP 90L Single stage with single phase complete all as specified and directed.
M&L for Air compressor 3HP 180L Single stage with three phase complete all as specified and directed.
M&L for Air compressor 3HP 180L Single stage with single phase complete all as specified and directed.
M&L for Air compressor 3HP 220L Single stage with three phase complete all as specified and directed.
M&L for Air compressor 5HP 180L Single stage with three phase complete all as specified and directed.
M&L for Air compressor 5HP 220L Single stage with three phase complete all as specified and directed.
M&L for Air compressor 5HP 280L Single stage with three phase complete all as specified and directed.
M&L for Bed Headed Panel and Railing :- Double railing Bed head panels Should have below accessories (i) Stand Extendable type with aluminum slider. (ii). Monitor stand wall Panel mounted. (iii). Ward vacuum unit slider. (iv). SOCKET 5/15 Amp-6NOS . Electrical Sockets Provision Gas/Vacuum outlets as follows :- (i) Two oxygen outlet. (ii)TWO Vacuum outlet. (iii)One Compressed Air outlet 4 Bar
M&L for Oxygen Manifold: Main :- 6+6 Cylinder Oxygen Manifold should be suitable to withstand a pressure of 140 Kg/Cm2and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick complete all as specified and directed. Note: (i)The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. (ii)The manifold should be tested (hydraulically) at 3500 psig
M&L for Oxygen Manifold: Emergency 2 Cylinder Oxygen Manifold should be suitable be withstand a pressure of 140 Kg/Cm2and above, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mmI.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick and a single state high pressure high flow regulator connected to a high pressure brass block. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely complete all as specified and directed. Note. (i)The manifold should be tested (hydraulically) at 3500 psig and necessary test certificates should accompany along with the supply. (ii)Manifold should have in built Siren System
M&L for Nitrous Oxide Manifold: Main 02x1 Cylinder Nitrous Oxide Manifold should be suitable to withstand a pressure of 140 Kg/Cm2and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick complete all as specified and directed. Not-(i)The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. (ii)The manifold should be tested (hydraulically) at 3500 psig
Installation, Testing & Commissioning of the complete medical gas piping system and it's accessories complete all as specified and directed.
Supply ,installation ,testing and commissioning of nominal cooling capacity-48 TR AIR -COOLED SCROLL CHILLER (2W+1 Stand by)complete with multiple compressor hermetic/semi hermetic,multiple scroll type compressor each with steps less capacity control of 25% to 100% of the rated capacity with microproccesor based control panel for compressor motor with suitable capacity electric motor starter in panel, machine mounted,air cooled condensor,insulated chiller,water flow switch,vibration isolators,internal refrigerant piping and wiring with 2 circuits,automatic and safety controls mounted in central console panel and all mounted on a steel frame complete,motor shall be suitable for 415 V 3 phase AC supply.Refrigerant gas used shall be R-407C/R22 complete all as specified and directed.
Supply, installation, testing and commissioning of Monoblock horizontal pumping sets for chilled water circulation system. The pump shall be suitable for the given duty points - 3 Nos Each (Out of Three pumps, Two will be working and one will be standby). (i) Water Quantity - 115 USGPM (ii) Static Head - 20M (iii) Speed - 1450 RPM (iv) Impeller - Bronze (v) Shaft - High Tensile steel (vi) Pump/motor body - CI (vii) Seal - Mechanical (viii) Motor - Suitable HP TEFC, 415 Volt, 3 phase, 50 Hz (ix) Starter - Star-Delta (x) Base frame - Fabricated MS
Supply, laying, fixing, testing and commissioning of Chilled water, water piping of size 80mm dia with MS ERW class ' C' pipe (Heavy conforming to ISS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, descaling valves. The piping shall be laid overhead in plant and underground outside the plant room complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Chilled water, water piping of size 65mm dia with MS ERW class ' C' pipe (Heavy conforming to ISS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, descaling valves. The piping shall be laid overhead in plant and underground outside the plant room complete all as specified and directed.
Supply, installtaion, testing and commissioning of PVC Expansion tank of size 1000 ltr capacity complete with duly insulated with 25mm thick Nitrile rubber covered with aluminium cladding with vent and drain connection with flloat valve at the required height to flow the water in to the chiller unit complete all as specified and directed. Note: The cost of the providing & fixing the MS angle and fabication shall be deemed to included in qouted rate
Supply, laying, fixing, testing and commissioning of Balancing Valve 80 mm dia complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Y Strainers 80 mm dia complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of air surge Valve 15 mm dia complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Pressure Gauge of 100 mm dial with siphon & isolation valve 0 to 10kg complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of digital thermometer for industrial use of AC plant complete all as specified and directed.
Supply installation testing and commissioning low density polyethylene drain pipes size 50 mm dia (LDPE) of pressure rating 4 Kg/cm² on walls/ceiling or laying in floors including fixing with pipe fittings complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation 25mm thick on chilled water piping of size 80mm dia complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation 25mm thick on chilled water piping of size 65mm dia complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation 25mm thick on butterfly valve of size 80mm dia complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation 25mm thick on butterfly valve of size 65mm dia complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation on balancing valve of size 80mm dia complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation on Non Return Valve of size 80mm dia complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation 25MM thick on ‘Y’ Strainer of size 80mm dia complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation 25mm thick on 2way balancing valve of size 80mm dia complete all as specified and directed.
(Design, Supply, Installation, testing and commissioning Factory made high static double skinned horizontal type Air Handling Unit 1 [AHU1] 22 TR 7000 CFM (Static Pressure 50WG)with 0.6mm thick pre coated outer skin & 0.6mm thick inner skin made out of GI sheet comprising of backward or forward curved centrifugal blowers of adequate capacity housed in blower section, 3 phase squirrel cage induction motor adequate capacity TEFC type complete with motor pulleys with V-belts. Coil section with cooling coil multi row deep copper tubes with multi row deep with hydraulically bounded sine wave A1 fins tested for17 Kg/Sqcm pressure Filter section complete with cleanable type prefilter metallic type having efficiency 90% down to 10 micron. The make of cooling coils will be as per manufacturer of AHU. The insulation with 25mm thick PUF panels. The AHUs will be floor mounting with anti vibration pads for cooling the air with all accessories and controls comprising the following including painting etc as per standard practice:- INDOOR TYPE (a)Chilled water cooling coil 8 Row with copper tubes not less than 0.5mm thickness and 13mm over all diameter 10 to 12 aluminium fins per inch. (b) Micro Vee filters having dust filtration capacity of 5 microns and above down to 95%suitable to requisite static pressure with Belt drive flame proof squirrel cage inductionmotor TEFC, 415V, 3 phase, 50 Hz, AC supply class ‘B’ insulation. (c) Electrically controlled / operated controls such as humidistate and thermostat along withall equipment and accessories connection to AHU as per design requirement. (d) Self removable panels with thermal and acoustic insulation. (e) Sloped bottom to collect humidification and condensate water for draining and drainpiping of sufficient size and length as per standard practice. (f) Plenum to house micro vee filters and conical section to connect ducting with flexibleducting (canvas). (g) Acoustic insulation shall be with suitable thickness (not less than 19 mm) elastomeric Nitrile Rubber Open Cell Foam from the mouth of the AHU upto appropriate length as per standard practice. (h) Control for AHU with blower motor, heating thermostat, humidistat etc., with all accessories shall be deemed to be included as per manufacturer’s specifications.
(Design, Supply, Installation, testing and commissioning Factory made high static double skinned horizontal type Air Handling Unit 1 [AHU2] 27 TR 8000 CFM (Static Pressure 50WG)with 0.6mm thick pre coated outer skin & 0.6mm thick inner skin made out of GI sheet comprising of backward or forward curved centrifugal blowers of adequate capacity housed in blower section, 3 phase squirrel cage induction motor adequate capacity TEFC type complete with motor pulleys with V-belts. Coil section with cooling coil multi row deep copper tubes with multi row deep with hydraulically bounded sine wave A1 fins tested for17 Kg/Sqcm pressure Filter section complete with cleanable type prefilter metallic type having efficiency 90% down to 10 micron. The make of cooling coils will be as per manufacturer of AHU. The insulation with 25mm thick PUF panels. The AHUs will be floor mounting with anti vibration pads for cooling the air with all accessories and controls comprising the following including painting etc as per standard practice:- INDOOR TYPE (a)Chilled water cooling coil 8 Row with copper tubes not less than 0.5mm thickness and 13mm over all diameter 10 to 12 aluminium fins per inch. (b) Micro Vee filters having dust filtration capacity of 5 microns and above down to 95%suitable to requisite static pressure with Belt drive flame proof squirrel cage inductionmotor TEFC, 415V, 3 phase, 50 Hz, AC supply class ‘B’ insulation. (c) Electrically controlled / operated controls such as humidistate and thermostat along withall equipment and accessories connection to AHU as per design requirement. (d) Self removable panels with thermal and acoustic insulation. (e) Sloped bottom to collect humidification and condensate water for draining and drainpiping of sufficient size and length as per standard practice. (f) Plenum to house micro vee filters and conical section to connect ducting with flexibleducting (canvas). (g) Acoustic insulation shall be with suitable thickness (not less than 19 mm) elastomeric Nitrile Rubber Open Cell Foam from the mouth of the AHU upto appropriate length as per standard practice. (h) Control for AHU with blower motor, heating thermostat, humidistat etc., with all accessories shall be deemed to be included as per manufacturer’s specifications.
(Design, Supply, Installation, testing and commissioning Factory made high static double skinned horizontal type Air Handling Unit 1 [AHU3] 30 TR 13000 CFM (Static Pressure 50WG)with 0.6mm thick pre coated outer skin & 0.6mm thick inner skin made out of GI sheet comprising of backward or forward curved centrifugal blowers of adequate capacity housed in blower section, 3 phase squirrel cage induction motor adequate capacity TEFC type complete with motor pulleys with V-belts. Coil section with cooling coil multi row deep copper tubes with multi row deep with hydraulically bounded sine wave A1 fins tested for17 Kg/Sqcm pressure Filter section complete with cleanable type prefilter metallic type having efficiency 90% down to 10 micron. The make of cooling coils will be as per manufacturer of AHU. The insulation with 25mm thick PUF panels. The AHUs will be floor mounting with anti vibration pads for cooling the air with all accessories and controls comprising the following including painting etc as per standard practice:- INDOOR TYPE (a)Chilled water cooling coil 8 Row with copper tubes not less than 0.5mm thickness and 13mm over all diameter 10 to 12 aluminium fins per inch. (b) Micro Vee filters having dust filtration capacity of 5 microns and above down to 95%suitable to requisite static pressure with Belt drive flame proof squirrel cage inductionmotor TEFC, 415V, 3 phase, 50 Hz, AC supply class ‘B’ insulation. (c) Electrically controlled / operated controls such as humidistate and thermostat along withall equipment and accessories connection to AHU as per design requirement. (d) Self removable panels with thermal and acoustic insulation. (e) Sloped bottom to collect humidification and condensate water for draining and drainpiping of sufficient size and length as per standard practice. (f) Plenum to house micro vee filters and conical section to connect ducting with flexibleducting (canvas). (g) Acoustic insulation shall be with suitable thickness (not less than 19 mm) elastomeric Nitrile Rubber Open Cell Foam from the mouth of the AHU upto appropriate length as per standard practice. (h) Control for AHU with blower motor, heating thermostat, humidistat etc., with all accessories shall be deemed to be included as per manufacturer’s specifications.
Supply, fabrication, installation, testing and commissioning of galvanised steel sheet (G.S.S.) supply ducting in square/ rectangular shape fabricated from galvanised steel sheet of 24 gauge galvanized sheet steel (0.6 mm) having zinc coating of 120 gm/sq.m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 (Revised upto date) all as specified and including with required scafolding work to install the ducts at site complete all as specified and directed
Supply, fabrication, installation, testing and commissioning of galvanised steel sheet (G.S.S.) supply ducting in square/ rectangular shape fabricated from galvanised steel sheet of 22 gauge galvanized sheet steel (0.6 mm) having zinc coating of 120 gm/sq.m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 (Revised upto date) all as specified and including with required scafolding work to install the ducts at site complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Air Diffuser With Volume Control Damper of size 250x200mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Supply Air Diffuser With Volume Control Damper of size 200x200mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Diffuser With Volume Control Damper of size 200x200mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Diffuser With Volume Control Damper of size 250x200mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Diffuser With Volume Control Damper of size 300x300mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Air Grill with Volume Control Damper of size 1200x900mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 900x600mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 800x500mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 700x600mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 650x400mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 600x500mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 600x400mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 1100x800mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 1000x600mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 900x600mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 700x600mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 700x450mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 700x400mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 650x500mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 600x500mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 600x450mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 450x300mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Fire Dampers with Fusible link of size 1100x800mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Fire Dampers with Fusible link of size 900x600mm as per the OEM standard of AC plant complete all as specified and directed
Supply, laying, fixing, testing and commissioning of Fire Dampers with Fusible link of size 800x500mm as per the OEM standard of AC plant complete all as specified and directed
Supply install testing and commissioning of pan humidifier of capacity 5KW for winter season with connecting pipe with all accessories, valves etc. from tank with necessary heaters and connection wiring complete with humidist complete all as specified and directed
Supply, Install, Testing and Commissioning of thermostate, humidistat and Air stat for monsoon/winter condition (1 SET for each bank) complete all as specified and directed
Supply, Installation, Testing and Commissioning of Thermal Insulation for Inside Supply air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick 3 " wide aluminium foil faced self adesive tape at all joints as per the approved drawings complete all as specified and directed
Supply, Installation, Testing and Commissioning of ACCOUSTIC Insulation for Supply air ducting with 13 mm thick OPEN cell elastrometric Nitrile rubber and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade complete all as specified and directed
Supply, Installation, Testing and Commissioning of Thermal Insulation for Inside return air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick 3 " wide aluminium foil faced self adesive tape complete all as specified and directed
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor mounting, dust and vermin proof cubical type, CPRI approved, LT panel fabricated from 2.0 mm Indoor type thick CRCA sheet duly compartmentalized for each switch gear , front and rear open-able ( front hinged opening) ,locking arrangement with chromium plated 19 mm dia locks ( min 2 Nos in each compartment), lifting lugs of suitable size on top, louvers and air vent gasket for natural air, `U` shape rubber gasket, voltmeter, ammeter, APFC Relay, Frequency meter. Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade suitable for 600 amps with suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance , high strength FRP/SMC/DMC material at an interval not more than 500 mm throughout the length of bus bars , including suitable aluminum earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper copper/ aluminum lugs. The cubical incomer MCCB as well as outgoing shall have copper TPN extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link of min 500 mm long supported on suitable size `F` class insulator to be provided for termination on incomer and outgoing cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel should be mounted on bottom channel of suitable size with proper mounting arrangement as directed by Engr-in-Charge leaving min 500 mm all around the panel board for movements all as specified with supply and fixing the following:-
Supply, installation, testing and commissioning of LT, automatic power factor correction (APFC) panel, factory made, weather, dust & vermin proof made out of 16 gauge CRCA steel sheet duly powder coated paint with metalised poly propylene (MPP) type capacitors bank, heavy duty of 80 KVAR with variable correction shall comprise of 03 Nos stepping (1X10+1X20+2x25KVAR). The panel shall have copper bus bar of suitable size, 3 phase and with neutral and with the following:- (a) MCCB, TP, 160 Amps (adjustable type), 25 KA – 01No (incoming) (b) Heavy duty Contactors suitable frequent operation having current limiting resistors suitable for capacitive switching of variable KVAR correction of superior specifications. (c) MCCB/MCBs 'C' curve for back up protection of capacity as required. (d) Microprocessor based intelligent APFC relay for controlling variable connection KVAR (e) Indication lamp RYB (LED type) with toggle switch – 03 Set (f) MPP type heavy duty capacitor bank consisting of suitable No of switching sequences, 3 phase, 415 volts suitable for 10% over voltage & 30% over current having loses less than 0.5 W /KVAR with discharge resistors. (g) Suitable Nos & rating of contractors as required. (h) Internal wiring of panel with stranded copper cable of suitable size. Note: The MCCBs of breaking capacity 25 KA and above shall be Ics=100% Icu
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor/wall mounting, dust and vermin proof cubical type, CPRI tested, LT panel fabricated from 2.00 mm thick CRCA sheet , duly compartmentalized for each switch gear , front and rear open-able ( front hinged opening) ,locking arrangement with chromium plated 19 mm dia fancy locks ( min 2 Nos in each compartment), lifting lugs of suitable size on top, louvers and air vent gasket for natural air, `U` shape rubber gasket. Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade for 400 amps with suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance , high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of bus bars including suitable aluminum earth strips, with danger notice plate, necessary cable glands, cable connection with proper aluminum/ copper lugs, The cubical incomer MCCB as well as out going shall have copper TPN extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link of min 200 mm long supported on suitable side `F` class insulator to be provided for termination on incomer and out going cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel should be mounted on angle iron frame of size 40x40x5 mm and further mounted on PCC foundation and pedestal having min 300 mm all around the feeder pillar board for movements all as specified with supply and fixing the following:-
Supply & fix cable route / chilled water pipe route route indicator made of 6mm thick/ 6 inch dia cast iron plate duly embedded with latest LT cable / Chilled water pipe/ Hot water pipe fix in angle in 25mm X 3mm of length 40mm with fix in foundation complete all as specified and directed NOTE- PCC, Excavation & Earth work shall be measured and paid separately
Supply, fixing , testing & commisining of heater banks in multi bank 20 KW (in 2 banks) complete all as specified and directed
Supply, fixing , testing & commisining of heater banks in multi bank 20 KW (in 3 banks) complete all as specified and directed
Supply, installation, testing & commissioning of AIR COOLED VARIABLE REFRIGERANT VOLUME MODULAR TYPE AIR CONDITIONING SYSTEM having VRF Top Discharge out door units Twin Rotary Compressor/Scroll comprressor technology and low noise with R410a and on 380-440V,50Hz,3Phase A/C of capacity 14 HP . The unit shall consist of indoor units and external condensing units including y-joints between indoor and outdoor units other accessories ) complete all as specified and directed
Supply, installation, testing & commissioning of AIR COOLED VARIABLE REFRIGERANT VOLUME MODULAR TYPE AIR CONDITIONING SYSTEM having VRF Top Discharge out door units Twin Rotary Compressor/Scroll comprressor technology and low noise with R410a and on 380-440V,50Hz,3Phase A/C of capacity 10 HP . The unit shall consist of indoor units and external condensing units including y-joints between indoor and outdoor units other accessories ) complete all as specified and directed
Supply ,installation,testing and commissioning of factiry fabricated Double skinned DX Air handling unit with (floor mounted type)fabricated out of extruded aluminium section with 0.8mm pre-plasticized/pre-coated galvanised steeel sheet outside & 0.8mm plain galvanised steel sheet inside with belt driven centrifugal fans(forward/backward) blower section and blower motor TEFC type IE-3 grade suitable for operation on 415 V +10%,50HZ +5% AC supply,6 row cooling coil made of aluminium finned(12-13Fins/inch) copper tube with coil section of copper head and MS adapter,pre filter section with non woven synthetic media of 50mm thick in extruded aluminium frame of 10 micron particle size with an effiency of 90% of suitable MERV 8 rating ,filters in aluminum frame.drain pipe(made out of 22 guage stainless(SS Grade304) sheet insulated with 19mm thick closed cell insulation nitrile complete with motor,belt drive,fire retardent double layer canvass connection etc without face and bypass dampers. Centrifugal fan(with min efficiency as per NBC 2016)with blower motor,drive and flexible duct connection.The AHU shall be insulated with 23mm thick (for indoor application & 43 mm thick with thermal break profile( for outdoor application) of 36kg/m3 density PU foam. 4000CFM/10 TR,6 row DX coil,1x180dia fan with 1.5kw fan motor IE-3 rating pre filter,F/M type to be connected 1x14HP VRF ODU.
Supply ,installation,testing and commissioning of factiry fabricated Double skinned DX Air handling unit with (floor mounted type)fabricated out of extruded aluminium section with 0.8mm pre-plasticized/pre-coated galvanised steeel sheet outside & 0.8mm plain galvanised steel sheet inside with belt driven centrifugal fans(forward/backward) blower section and blower motor TEFC type IE-3 grade suitable for operation on 415 V +10%,50HZ +5% AC supply,6 row cooling coil made of aluminium finned(12-13Fins/inch) copper tube with coil section of copper head and MS adapter,pre filter section with non woven synthetic media of 50mm thick in extruded aluminium frame of 10 micron particle size with an effiency of 90% of suitable MERV 8 rating ,filters in aluminum frame.drain pipe(made out of 22 guage stainless(SS Grade304) sheet insulated with 19mm thick closed cell insulation nitrile complete with motor,belt drive,fire retardent double layer canvass connection etc without face and bypass dampers. Centrifugal fan(with min efficiency as per NBC 2016)with blower motor,drive and flexible duct connection.The AHU shall be insulated with 23mm thick (for indoor application & 43 mm thick with thermal break profile( for outdoor application) of 36kg/m3 density PU foam. 3000CFM/8 TR,6 row DX coil,1x180dia fan with 1.5kw fan motor IE-3 rating pre filter,F/M type to be connected 1x10HP VRF ODU.
M & L for Pressure testing With nitrogen (N2) complete all as specified and directed
Supply of copper refrigerant piping interconnecting the indoor unit and air cooled condensor along with 9mm thick foam insulation Hard drawn For Suction Line: 7/8" complete all as specified and directed
Supply of copper refrigerant piping interconnecting the indoor unit and air cooled condensor along with 9mm thick foam insulation Hard drawn For Liquid Line: 1/2" complete all as specified and directed
Supply of copper refrigerant piping interconnecting the indoor unit and air cooled condensor along with 9mm thick foam insulation Hard drawn For Gas Line: 1" complete all as specified and directed
S & F of Canvas of high quality and quantity as recommended by OEM for making connections for connecting the ducting and indoor units complete all as specified and directed
S & F of Ms structural work / M.S Stands for erection of condensing Units as recommended by OEM complete all as specified and directed
S & F of thermal Insulation using 9mm thick class ' 1' nitrile rubber insulation complete all as specified and directed
S & F of Acoustic insulation of Open cell 10mm nitrile rubber insulation complete all as specified and directed
S & F of Aluminium powder continue grill without Collar Dampers as recommended by OEM complete all as specified and directed
S & F of MS Collar Dampers as recommended by OEM complete all as specified and directed
S & F of Volume Control Duct Dampers as recommended by OEM complete all as specified and directed
S & F of PVC Drain Piping 25 mm dia complete all as specified and directed
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts OUTDOOR type, factory made free standing, floor/wall mounting, dust and vermin proof cubical type, CPRI tested, LT panel fabricated from 3.15 mm thick CRCA sheet , duly compartmentalized for each switch gear , front and rear open-able ( front hinged opening) ,locking arrangement with chromium plated 19 mm dia fancy locks ( min 2 Nos in each compartment), lifting lugs of suitable size on top, louvers and air vent gasket for natural air, `U` shape rubber gasket. Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade for 200 amps with suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance , high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of bus bars including suitable aluminum earth strips, with danger notice plate, necessary cable glands, cable connection with proper aluminum/ copper lugs, The cubical incomer MCCB as well as out going shall have copper TPN extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link of min 200 mm long supported on suitable side `F` class insulator to be provided for termination on incomer and out going cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel should be mounted on angle iron frame of size 40x40x5 mm and further mounted on PCC foundation and pedestal having min 300 mm all around the feeder pillar board for movements all as specified with supply and fixing the following:-
Supply, installation, testing and commissioning OF Unidirectional Laminar Air Flow Plenum Ceiling ‐ constructed out of 1.5 mm thick SS 304 sheet of size 2700 X 2500X350 mm having 8 nos of hepa filters. The hepa filters having dust spot efficiency of 99.99% 0.3 micron. Air & Light diffuser made of mono filament precision woven polyester forthe plan air ceiling to give a ″LAMINAR FLOW″ of filtered air. It also provides a diffused shadow less lighting system with Intensity control. complete all as specified and directed
Supply, installation, testing and commissioning OF HVAC‐Ducting inside OT′s Aluminium ducting with 22 Gauge Sheet including all fixtures and accessories, Insulation with 19 mm thick polypropylene insulation for supply & return duct and 13 mm thick for return air ducts complete all as specified and directed
Supply and fix air curtain size 6 ft, max velocity 25 m/s , total air flow 150cfm, static pressure 0.031 (in.w.g) ,blower dia 125mm speed 2800 rpm with remote operated ,voltage supply 220v complete all as specified and directed
S&F ceiling mounted motion sensor for automatic light on/off range 8 meter 3 wire with neutral,adjustable time delay 5s to 30min complete all as specified and directed
Supply,Installtation & commissionning Solar day lighting system roof mounted with complete following accessories 1.The light pipe solar lighting system constiutes the following components. (a) light collector (b)Light transfer system (c) Light diffuser (d)Roof kerb (e) Fixing accessories. 2.Sun Light Collector Dome:- (a)The transparent clear dome allows light to be colllected across the sky from all directions. (b)It should be moulded ,single piece, Dome shaped. (c)Material -tranparent polycarbonate . (d)thickness- 3mm thick polycarbonate sheet. (e)Thermal Conductivity-0.21/mc (f) Heat resistance Temp:-45degree-150degree celsius. 3.Light Transfer system-Extension pipes:- (a) Diameter:-530mm/400mm (b)Shape-Cylindrical shape (c)Material:-Aluminium (d)Material thickness:-not less than 0.4mm. 4.Light Diffuser:- (a)Material:- Clear Bright Diffuser (b) Thickness-2mm thick (c)Light transmission-not less than 80%. (d)Diffuser Ring-Injection molded ABS plastic ring-white color. (e) Glazing-Double glazed. (f) Diffuser to pipe fixing:-Locking button provision of pipe into the diffuser ring with silicon seal.
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One light point controlled by one,one way switch complete all as specified and directed
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One ceiling/exhaust fan point controlled by one switch complete all as specified and directed
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One3 pin 5 amps socket out let point on independent board complete all as specified and directed
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one call bell point controlled by one call bell switch complete all as specified and directed
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One light point controlled by two, two way switches complete all as specified and directed
M & L for Concealed Point wiring with 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 04 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one 16 Amp socket outlet on independent board complete all as specified and directed
S &F wireless nurse call bell system with 10 call panel, complete all as specified and directed
S&F modular flush Box 8 module complete all as specified and directed
S & F LED light fittings decorative 18Watt Recessed mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc. complete all as specified and directed
S & F LED light fittings decorative 18Watt surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc. complete all as specified and directed
S & F LED 6Watt night lamp extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories with holder internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps etc. complete all as specified and directed
S & F LED 5Watt wall mounted bulb extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories with holder internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc. complete all as specified and directed
S & F of LED batten with inbuilt driver made out of high quality aluminium extruded housing and aluminium heat sink for mounting LEDs, mercury free and decorative end caps with maximum power consumption 9-10 Watts with min system luminous efficiency lumen/watt > 100, CCT not less than 6500K and CRI > 80, operating voltage of 140-270 volts AC, P.F. > 0.90, 2.5 KV surge protection and current THD < 15% complete and including all other standard accessories as per manufacturer's instructions, internally pre-wired including connecting up with twin core 0.75 Sqmm copper conductor flexible wire/cable complete all as specified and directed
S & F of LED batten with inbuilt driver made out of high quality aluminium extruded housing and aluminium heat sink for mounting LEDs, mercury free and decorative end caps with maximum power consumption 20 Watts with min system luminous efficiency lumen/watt > 100, CCT not less than 6500K and CRI > 80, operating voltage of 140-270 volts AC, P.F. > 0.90, 2.5 KV surge protection and current THD < 15% complete and including all other standard accessories as per manufacturer's instructions, internally pre-wired including connecting up with twin core copper conductor flexible wire/cable complete all as specified and directed
S & F LED Security/Street light fittings 25 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size etc. complete all as specified and directed
Fabricate,supply & fix GI pipe bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 25W ssecurity light fitting complete all as specified and directed
M & L for Sub main Wiring with two run of 2.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 2.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Two single core cable and one No. earth wire and one run of conduit shall be measured together as one length
M & L for Sub main Wiring with two run of 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Two single core cable and one No. earth wire and one run of conduit shall be measured together as one length
M & L for Sub main Wiring with two run of 6.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 6.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Two single core cable and one No. earth wire and one run of conduit shall be measured together as one length
M & L for Sub main Wiring with four run of 10.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 10.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Four single core cable and one No. earth wire and one run of conduit shall be measured together as one length
M & L for Sub main Wiring with four run of 16.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 16.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Four single core cable and one No. earth wire and one run of conduit shall be measured together as one length
M&L for MCB DB TPN 6 way with IP 43 protection,Glazed double door,200A rated bus bar, 1 phase complete all as specified and directed.
M&L for vertical MCCB DB TPN 4 way MCCB incomer with IP 43 protection,double door with 200A rated bus bar, 3 phase complete all as specified and directed.
Supply & fixing wall mounted fan 450 mm sweep high speed, thermally protected motor, heavy duty gear box, 90 degree oscillation for wide coverage conforming to IS-2997-1964 complete all as specified and directed.
Supply & fixing Reading lamp 6watt complete all as specified and directed.
M&L for PVC junction box up to 4 Way complete all as specified and directed.
M&L for telephone jak with Modular metal flushed including flushed Box cover plate Box for 2 Way module complete all as specified and directed.
M&L for TV SOCKET with Modular metal flushed including flushed Box cover plate Box for 2 Way module complete all as specified and directed.
Supply & fix hand dryer wall mounted size 220x240x230mm,power supply 230v complete all as specified and directed.
Supply, installation, testing and commisioning OF LED Peripheral Lights : Recess mounted IP54 Protocol, Non hygroscopic Peripheral Lights 60 Watt having controls. The Peripheral light diffuseris fixed in powder coated aluminium frame. (Size: 1000/1200 X 230 mm) complete all as specified and directed.
Supply & fix DWCPE (SN8) pipe of outer dia 150mm confirming to IS 16098(Part-2):2013 complete all as specified and directed.
Supply & fix 2 way bib cock 15mm dia with flow restrictor of make Jaquar Model No CQT-CHR-23041GD or equivalent make as specified in list of makes complete all as specified and directed.
Supply & fix Florentine 15mm dia pillar cock with flow restrictor, quarter turn of brass, knob controlled of make Jaquar Model No FLR-CHR-5015G or equivalent make as specified in list of makes complete all as specified and directed.
Supply & fix 20mm dia stainless steel concealed stop cock with flow restrictor, regular body with adjustable wall flange of make Jaquar Model No CQT-CHR-23083K or equivalent make as specified in list of makes complete all as specified and directed.
Supply & fix 25mm dia stainless steel concealed stop cock with flow restrictor, regular body with adjustable wall flange of make Jaquar model No SPL-CHR-551 or equivalent make as specified in list of makes complete all as specified and directed.
Supply & fix overhead shower rose 80mm dia (ABS body chromium plated for fixing shower arm 15mm size with bend of 45 degree with flange of make Jaquar Model No OHS-CHR-1989G (OH Shower), SHA-CHR-477 (Arm) or equivalent make as specified in list of makes complete all as specified and directed.
Supply & fix wall mixer 3-in-1 system with flow restrictor, with provision for overhead shower connection with 115mm long bend pipe on upper side, connecting legs & wall flange of make Jaquar Model No CQT-CHR-23281UPRGD or equivalent make as specified in list of makes complete all as specified and directed.
Supply & fix sink cock with swinging casted round shape spout (wall mounted model) 20mm dia with flow restrictor, quarter turn of make Jaquar Model No CQT-CHR-23347GD or equivalent make as specified in list of makes complete all as specified and directed.
Supply & fix brass angular stop cock quarter turn with flow restrictior (wall mount with 20mm dia of make Jaquar Model No CQT-CHR-23059 or equivalent make as specified in list of makes complete all as specified and directed.
Supply & fix health faucet (ABS body) with 01 meter long PVC & wall hook, of make Jaquar Model No ALD-CHR-573G or equivalent make as specified in list of makes complete all as specified and directed.
Supply & fix brass urinal flush valve of 40mm dia round shape (installation type wall mount) of make Jaquar Model No FLV-CHR-1093NSQG or equivalent make as specified in list of makes complete all as specified and directed.
Supply & fix non return valves 40mm dia with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
Supply & fix 63mm dia 30meter long hose conforming to IS 636 with male and female coupling conforming to IS 903 complete all as specified and directed.
Supply & fix clean agent HFC 236fa based fire extinguisher of 4 Kg capacity with initial charge valve bend with handle wall fixing bracket etc complete all as specified and directed.
Supply & fix fire bucket filling with dry sand as per IS:2546 with handle in red colour complete all as specified and directed.
Supply & fix wall mounted CD speaker 10watt complete all as specified and directed.
Supply & fix of amplifier suitable 250watt, 230VAC, 50Hz having following properties/accesseries (i) Power source:AC 220V, 50Hz, DC-12V battery (ii) Power consumption:250watt (iii) Channels:6 (iv) Colour: Black (v) Audio input/output:6xMIS 0.60mV/4.7Kohm
Supply & fix microphone set complete all as specified and directed.
Supply, installation, testing and commisioning of anologue addressable repeater panel shall be with switch mode power supply, battery back up charger. The panel shall consisting with 160 character LCD display, touch keys, shall be networkable by RS 485 or TCP/IP, repeater/mimic connectivity. USB -2.0 for PC interface. Degraded redundancy operating mode when the main CPU fail complete all as specified and directed.
Supply, installation, testing and commisioning of anologue addressable addressable main fire alarm control panel complying with BS En 54 shall be with switch mode power supply, battery back up charger. The panel shall have loops and with 200 devices per loop in any combination. The panel shall consisting with 160 character LCD display, touch keys, shall be networkable by RS 485 or TCP/IP, repeater/mimic connectivity. USB -2.0 for PC interface. Degraded redundancy operating mode when the main CPU fail with following items:- (i) Standard LCD monitor (01No) (ii) Telephone-01 Set (iii) Router -01 Set (iv) Switch hub port-01set (v) Cat 6 Cable-25 RM (vi) Printer-01 No
S&F sheet metal enclosure DB SPN 240 Volts 6 way double door type for fixing MCB complete all as specified and directed.
M&L Steel Tubular Swaged welded Poles Type 410-SP-22 (8.5 Metre long) including cast iron base plate, finial taper plug, cap, mild steel bolts, screws, etc. including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of aluminium primer (externally from top of PCC copping) and add four alternate layer of black and yellow colour strip of width 30 CM each above the top surface of the coping including writting MES Pole No. with synthetic enamel paint (first grade quality) complete all as specified and directed. Note:- (a) Earthwork shall be measured and paid under appropriate items in Schedule 'A' Part-II and PCC shall be measured and paid under relevant items in this Schedule. (b) Volume occupied by Steel Pole shall be deducted to derive the quantity of PCC.
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for end termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. complete all as specified and as directed.
Supply, installations, testing and commissioning Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V, 3 Phase. 50 Hz 70m Head, 2280 LPM discharge at minimum pressure 3.5Kg/cm2, speed 2900RPM complete all as specified and as directed.
Supply, installations, testing and commissioning Fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz AC supply 70 m Head. 1620 LPM discharge at minimum pressure 3.5Kg/cm2, speed 1800RPM complete all as specified and directed.
M&L fire Hydrant landing valve type 'A' of size 63mm dia single head complete with instantaneous coupling conforming to IS -5290, including washer, gaskets, nuts bolts etc as required at site complete all as specified and directed.
S&F hose reel drum rotating type for 20mm dia of 30 meter length hose reel tubing conforming to IS-5132 including washers, gaskets, nuts, bolts, etc as required at site complete all as specified and directed.
S&F 63mm dia 15meter long hose conforming to IS-636 complete with male and female coupling conforming to IS 903 complete all as specified and directed.
Supply, installations, testing and commissioning of electronic horizontal type Fire Alarm sounders / Sirens two stage continous with control module normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of + 5 db 3500m range complete all as specified and directed.
S&F Pressure gauge 100mm dia with valve pressure 0-21 kgs rating complete all as specified and directed.
S&F approved quartzoid bulb 15mm dia Sprinkler pendant with rosette plate, with temperature rated at 68 degree with universable deflector as approved by T.A.C/IS-15106 complete all as specified and directed.
Supply ,installation,testing and commissioning of electronic, horizontal type Fire Alarm sounders / Sirens single stage continous with control module, normal operation for atleast 50 minutes, sound level 65 db to 120 db Measured at 1.5m with sound output Variation of + 5db 500m range range complete all as specified and directed.
S&F for Rigid steel conduit, welded stove enamelled metallic conduit of size 25 mm(outer dia) concealed in wall, ceiling slab, floor slab etc. inclusive of all steel conduit accessories such as junction box terminal box, all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
S&F of anolog Addressable sounder/flashes with standard control module complete all as specified and directed.
Design supply, installation testing & commissioning strecher cum passengers lift, having speed 0.5meter/sec to 1.5meter/sec metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS- 14665, suitable to serve 16 passengers (1020Kg) G + 04 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) automatic push button opening door for landing, haulting position indicator in car in all landing, cabin fan, cabin lighting, emergency lighting, connected civil work etc, including all other standards accessories as specified in IS:14665-1 Part-I and as per OEM of lifts standards and having minimum inside car size 1000mm x 2400mm and minimum ceiling height 2.30meters having front door opening 800mm complete all as specified and directed.
Design supply, installation testing & commissioning passengers lift, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS- 14665, suitable to serve 10 passengers (680Kg) G + 04 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) automatic push button opening door for landing, haulting position indicator in car in all landing, cabin fan, cabin lighting, emergency lighting, connected civil work etc, including all other standards accessories as specified in IS:14665-1 Part-I and as per OEM of lifts standards and having minimum inside car size 1300mm x 1350mm and minimum ceiling height 2.30meters having front door opening 800mm complete all as specified and directed.
Design, supply, installation, testing and commissioning 50,000 Litre underground high quality FRP (Fibre Glass Reinforced plastic) water storage tank confirming to IS, minimum thickness of the tank shall be 13mm, high temperature resistant alongwith top lid with locking arrangement, internal & external ladder, air vent nozzle with strap, level indicator equipped, including provision of inlet & outlet valve and necessary excavation and returning filling & 200mm thick M20 PCC base complete all as specified & directed..
Jasvit Constructions Private Limited
B D Raizada Projects Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid