| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | ₹7.5 L Quoted ₹7.7 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹7.8 L+₹11,562.83 (1.50%)Rejected-Finance | ₹7.8 L+₹11,562.83 (1.50%) | L2 | Rejected-Finance Other than L1, hence rejected |
| 3 | L3₹8.2 L+₹51,790.37 (6.73%)Rejected-Finance | ₹8.2 L+₹51,790.37 (6.73%) | L3 | Rejected-Finance Other than L1, hence rejected |
| 4 | L4₹8.3 L+₹55,554.68 (7.22%)Rejected-Finance 114 BARH CHONDI TOWN BARH DISTT PATNA BIHAR PIN 803213 | PATNA | BIHAR | 803213 | ₹8.3 L+₹55,554.68 (7.22%) | L4 | Rejected-Finance Other than L1, hence rejected |
| 5 | L5₹8.3 L+₹62,537.54 (8.12%)Rejected-Finance | ₹8.3 L+₹62,537.54 (8.12%) | L5 | Rejected-Finance Other than L1, hence rejected |
Tender Value
₹7.7 L
EMD Value
₹15,300
Closing Date
13 Oct 2021, 6:00 pmClosed
AGE (I) Naya Raipur
AGE (I) Naya Raipur Military Engineer Services C/O HQ COSA Near International Cricket Stadium Atal Nagar, Distt-Raipur (CG) Pin - 492101
SPL REPAIR TO MES INSTALLATIONS NEAR OFFICERS MESS AT NAYA RAIPUR MIL STN UNDER AGE (I) NAYA RAIPUR
2021_MES_469500_2
8400/302/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE (I) Naya Raipur
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
AGE (I) Naya Raipur
₹15,300
2 Nov 2021
28 Sept 2021
15 Oct 2021
28 Sept 2021
13 Oct 2021
29 Sept 2021
Amount
Taking out carefully existing unserviceable LT cable from panels and trenches any size any capacity and removing connection from exhisting switch board/over head lines etc complete all as specified.
Taking out carefully existing unsrviceable LT panel from foundation and removing without damaging any cable and earthing , complete all as specified and directed by Engr In Charge.
Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out for laying of pipe etc,. and getting out complete all as specified and directed
Returing filling in, including spreading levelling, watering and well ramming in layers not exceeding 25cm thick with earth obtained from excavation complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour for dry river washed and screened dry sand for filling in trenches below and around the cable for cushioning including punning down complete all as specified in relevant clause of SSR Part I. Note:- Punned thickness shall only be measured and paid.
Supply and lay bricks sub class 'B' laid dry abutting each other with gap between adjacent slab not exceeding 10mm over UG cable as in cable protection complete all as specified and directed.
Supply, lay and testing XLPE, insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade of 240 sqmm, 3.5 core cross sectional area laid in trenches/ poles/ ducts/ pipes or through sleeves etc., including connecting/ jointing with lugs complete all as specified and directed. Make : Polycab/Havells/Gloster
Supply, lay and testing XLPE, insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade of 70 sqmm, 3.5 core cross sectional area laid in trenches/ poles/ ducts/ pipes or through sleeves etc., including connecting/ jointing with lugs complete all as specified and directed. Make : Polycab/Havells/Gloster
M & L For Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground (earth pit not less than 2.25 metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI strip 32X6 sqmm by means of GI bolts, nuts, check nuts and washers and earth strip protected by 25 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion.Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. Note :- Earthing will be redone if desired earth result not found during testing of the same at site.
Supply and fix in replacement VTPN DB IP66/65 ( in accordance with IEC 60 529) AC combiner Feeder Pillar, the high flexibility of the modular enclosure system allows an easy upgrading of the assembly including bus bar system at any time even after many years , made of high quality Polycarbonate (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, self-extinguishing, having high impact, made of halogen and silicon free recyclable material conform to RoHS directive 2002/95/EC ). The DB shall have high grade gasket made of Polyurethane )PUR ) Dependent on the System,Environmental conditions for distribution boards according to IEC 61439-3: -5 °C up to 35 °C, max. + 40 °C; humidity: 50% at 40 °C, 100% at 25 °C for empty enclosures: - 25°C up to + 70 °C. Enclosure should be totally insulated, protection class II. And rated insulation voltage should be 690V AC as per IEC 60664.The LDB shall have following certificates and safety features,Weather proof: UV resistant according to IEC 61439-1,IEC 60 695-2-11: should withstand glow wire test at 9600C UL subject 94, should be flame retardant and self-extinguishing in nature, IEC 61 439-3: Intended to be operated by ordinary person.The party must be submitted routine test certificate from manufacturer/principal company in accordance with IEC 61 439-1,To provide grounding in connection metal plate should be provided inside polycarbonate flange for armored cable ( SWA – steel wired armored cable) via glands in accordance with British Standard ( IS: 5039 ).,The entire system should have hinged door and it can be combination of transparent or opaque lid. All the doors should be lockable type / door fasteners for tool and hand operated. NOTE: Guarantee and warrantee certificates from original manufacturer. To prevent the condensation in each distribution board “dew guard” to be used in right quantity in each system. Panel Board should be assembled in OEM System House only.VTPN DB Incomer : 250A FP 36kA MCCB – 01 Nos. Outgoing :63A TP 10kA MCB – 02 Nos,32A TP 10kA MCB – 02 Nos,16A SP 10kA MCB – 16 Nos. Cable Size Given :1R x 3.5C x 185 Sq.mm ARM Cable. Make- Hensel/ L&T/Schneider
Supply and Fix in replacement changeover of capacity 250 Amps with enclosure confirming to IS 13947 IES 60947-3 on load changeover four pole all as required and directed by engg in chrge Make HPL / L&T / Havells
Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 19,900.00
M/S INDIA ENTERPRISES
ashish shrivastava
M/S CHETAN PRAKASH GOYAL
rupesh kumar jha
ASHOKA ASSOCIATES
C GENDALAL AGRAWAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .