Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 CrAdmitted-Finance NEAR FLOUR MILL DHAIYA DHANBAD JHARKHAND 826001 | DHANBAD | JHARKHAND | 826001 | ₹6.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.9 Cr+₹21.0 L (3.17%)Admitted-Finance PRATAP NAGAR NAI SARAI RAMGARH CANTT 829122 JHARKHAND | RAMGARH | RAMGARH | JHARKHAND | 829122 | ₹6.9 Cr+₹21.0 L (3.17%) | L2 | Admitted-Finance |
| 3 | L3₹7.1 Cr+₹47.1 L (7.09%)Admitted-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | ₹7.1 Cr+₹47.1 L (7.09%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
| Sl No | Description | Qty | Unit | M/s Raj Construction L3 | M/S ADARSH CONSTRUCTION L2 | M/S RANG BAHADUR SINGH L1 |
|---|---|---|---|---|---|---|
| 1.00 | EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling, ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I. | 3,850.72 | cu.m | 100 ₹3,85,072 | 109.36 ₹4,21,114.74 | 90.77 ₹3,49,529.85 Lowest |
| 2.00 | Extra for earthwork in hard soil as per specification and direction of E/I. (Vide classification of soil item - B) | 3,808.35 | cu.m | 11 ₹41,891.85 | 11.17 ₹42,539.27 | 9.27 ₹35,303.4 Lowest |
| 3.00Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed. | ||||||
| 3.01 | Hard rock (blasting prohibited) | 796.15 | cu.m | 780 ₹6,20,997 | 882.19 ₹7,02,355.57 | 732.22 ₹5,82,956.95 Lowest |
| 4.00 | FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | 3,808.35 | CU.M | 36 ₹1,37,100.6 | 39.82 ₹1,51,648.5 | 33.05 ₹1,25,865.97 Lowest |
| 5.00 | FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | 724.18 | CU.M | 85 ₹61,555.3 | 92.84 ₹67,232.87 | 77.06 ₹55,805.31 Lowest |
| 6.00 | Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) | 1,858.61 | CU.M | 210 ₹3,90,308.1 | 223.35 ₹4,15,120.54 | 185.38 ₹3,44,549.12 Lowest |
| 7.00 | Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge | 1,975.53 | SQ.M. | 220 ₹4,34,616.6 | 202.62 ₹4,00,281.89 | 197.86 ₹3,90,878.37 Lowest |
| 8.00 | Providing designation 75-B, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge | 24.63 | SQ.M. | 205 ₹5,049.15 | 196.57 ₹4,841.52 | 191.95 ₹4,727.73 Lowest |
| 9.00 | Providing P.C.C. M-10 with nominal mix of (1:3:6) in Foundation with approved quality of stone metal grade III (53 to 22.4 mm size) and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixture, placing in position, vibration, striking, curing, taxes and royalty all complete as per building specification & direction of E/I. | 668.72 | CU.M | 3,400 ₹22,73,648 | 3,101.08 ₹20,73,754.22 Lowest | 3,217.37 ₹21,51,519.67 |
Tender Value
₹8.0 Cr
EMD Value
₹8.0 L
Closing Date
28 Dec 2020, 11:00 amClosed
Nodal Officer
e-Procurement Cell, JSBCCL Building, 3rd Floor, Project Bhawan Campus, Dhurwa
Construction of Inspection and Certification Centre at Dhanbad under Dhanbad District.
2020_JSBCC_46750_1
JSBCCL/13/2020-21
Open Tender
Civil Works - Buildings
Item Rate
450 days
RANCHI
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
JSBCCL
₹8.0 L
Yes
20 Jan 2021
17 Dec 2020
30 Dec 2020
17 Dec 2020
28 Dec 2020
17 Dec 2020
Amount
EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling, ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.
Extra for earthwork in hard soil as per specification and direction of E/I. (Vide classification of soil item - B)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed.
Hard rock (blasting prohibited)
FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing designation 75-B, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing P.C.C. M-10 with nominal mix of (1:3:6) in Foundation with approved quality of stone metal grade III (53 to 22.4 mm size) and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixture, placing in position, vibration, striking, curing, taxes and royalty all complete as per building specification & direction of E/I.
Providing R.C.C. M-20 with nominal mix of (1:1.5:3) in FOUNDATION and plinth with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in COLUMN with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of Engineer Incharge.
Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in BEAM with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of Engineer Incharge.
Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in STIFFENER with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of Engineer Incharge.
Providing R.C.C. M-20 with normal mix of 1:1.5:3 in ROOF SLAB with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in LINTEL BAND with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all comple as per building specificationand direction of E/I.
Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in LINTEL with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all comple as per building specificationand direction of E/I.
Providing R.C.C M-200 with nominal mix(1:1.5:3) in stair case with approved quality of stone chips 20 mm to 6 mm size graded and clean course sand of FM 2.5 to 3 including screening, shuttering, mixing cement concrete in concrete mixer and placing in position , vibrating, striking, curing (but excluding the cost of reinforcement)royalty and taxes all complete job as per building specification and direction of E/I.
Providing 63 mm thick R.C.C. M-20 with nominal mix of 1:1.5:3 in CHAJJA with approved quality of stone chips 20 mm to 6 mm size graded 20 mm to 10 mm, 10 mm to 6 mm stone chips by volume(2:1) and clean coarse sand of F.M. 2.5 to 3 including making drip course mix in concrete in mixer, placing in position screening, vibrating, striking, and providing 6 mm cement plaster (1:4) in ceiling and sides of Chajja with making drip course curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of Engineer Incharge.
Providing 35 mm thick precast R.C.C. M- 20 with nominal mix of (1:1.5:3) shelves with approved quality of stone chips 12mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 with 1.5 mm cement punning at top and side and 6mm cement plaster (1:4) at bottom including screening , curing and placing the slab in position(but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I.
Providing 25 mm thick DAMP PROOF COURSE with cement concrete M-20 with nominal mix 1:1.5:3 with approved quality of stone ships of 20 mm to 6 mm (20mm to 10 mm : 10 mm to 6 mm stone chips 2:1) size graded and clean coarse sand of F.M. 2.5 to 3 including screening, mixing cement concrete in mixer with 5% Cico or any other approved water proofing compound and placing in position, striking, curing taxes and royalty and complete as per building specification and direction of E/I.
Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing 125 mm thick REINFORCED DESIGNATION 75 A BRICK WORK in C.M. (1:4) in SUPERSTRUCTURE with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15 mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of Engineer Incharge .
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 12 mm thick water proof CEMENT PLASTER (1:6)on outside wall with clean coarse sand of F.M.1.5 and 5% cico/ waterproofing compound as specfied including cost of screening, curing making grooves with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I. (Cost of cico/ waterproofing compound will be paid separately)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Providing tor steel reinforcement TMT FE 500 of following dia. rods as per approved design and drawing including carriage of bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction and direction of E/I. (ONLY VALID FOR SAIL & TATA STEEL, JSPL, ELECTRO STEEL LTD. AND VIZAG STEEL)
TOR 8 & 10 MMDIA.
TOR 12 -32 MM DIA.
Providing & fixing FAN HOOK of 16 mm dia M.S. bar, 1 M long bent to required size and shape, placed in position and fluid in the R.C.C. slab-beam at the time of casting all complete as per building specification and direction of E/I.
Supplying, fitting & fixing 250 x 20 x 6 mm L-type M.S. clamp properly fishtailed including making holes and setting the same in 375 x 125 x 75 mm cement concrete block (1:2:4) with cost of all layout and materials and taxes as per building specification and direction of E/I.
Making 20x6 mm grooves in plaster surface over walls trully horizontal or vertical as specified at regular intervals at all heights including cleaning finishing , scaffolding and curing with all leads and lifts of water all complete as per buildinng specification and direction of E/I.
Extra for R.C.C. work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
Extra for PLASTER ON OUTER SIDE work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
FLOORING WORKS Providing and fixinging 20 mm thick mirror polished, machine cut for kitchen platform and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 (1cement :4 coarse sand) laid and jointed with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade
Area of slab over 0.5 sqm -
Extra for providing edge moulding to Granite stone counters, vanities etc. over above including machine polishing to edge to give high gloss finish etc. complete as per design approved by Architects / E/I.
Providing and laying DOUBLE CHARGE VITRIFIED FLOOR TILES in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08% and confirming to IS : 15622/ ISO 13006, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.30 kg per sqm including grouting the joints with white cement and matching pigments etc. complete.
SIZE OF TILE- 600MMX600MM
Providing & laying 15 mm to 23 mm thick KOTAH STONE SLAB FLOORING and skirting of approved size, texture and colour over 19 mm thick base of line mortar (1:1:1) Lime putty: Surkhi: Coarse sand) laid over and jointed with grey cement slurry mixed with pigment ot match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
600X600 SIZE
Providing and laying 25 mm thick kotah stone tiles in risers of steps, skirting and pillars of approved size texture and colour laid over 12 mm thick cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing to granolithic finish with approved quality of carborandum stone including cost of curing taxes and royalty all complete as per building specification and direction of E/I.
Extra for pre finished nosing to treads of steps of Kota stone/ sand stone slab
Providing and laying C.C. pavement of R.C.C. mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately), (Cost of reinforcement will be paid seperately).
Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. (AS PER APPROVED)
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Edges of slabs and breaks in floors and walls
Under 20 cm wide
Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and1.8 cm thick fixed in Urinal Partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement :2 coarse sand : 4 stone chips)as per direction of E/I and finished smooth. Granite Stone of approved shade.
Extra for FLOORING work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
Providing 50mm thick cement concrete flooring ( 1:2:4 ) with 20mm to 6mm size graded stone chips finished with floating coat of neat cement punning in panels, including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm cement plaster(1:3) with clean course sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing taxes and royalty all complete as per building specification and direction of E/I.
DOORS & WINDOWS WORKS
suppling , fitting and fixing good quality well dressed and well seasoned sal wood work in chaukhat in doors window ,sky light, fanlight and celevitial window opening including wedge over clmps all including application of two coats of wood preservative of approved quality on the surface , building walls and lintel all complete as per building specification and direction of El.
Supplying, fitting & fixing 35 mm th. Solid core type non-decorative single leaf FLUSH DOOR SHUTTERS in doors with block board core blended with high quality phenol formal dehydes synthetic resinboth side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts , handle,cleats aldrop, door stopper & sand blocks & taxes all complete as per detail drawing building specification & direction of the E/I.
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Particle Board 12 mm thick
Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i. e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium window, ventilator shutters etc. with EPDM / Neoprene gasket etc complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 4.0 mm thickness
Providing and fixing glazing in aluminium door, shutters etc. with PVC/neoprene gasket etc complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness.
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing aluminium TOWER BOLTS ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required color or shade with necessary screws etc. complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.. (Approved Brand - GODREJ/ DORSET)
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stoppers ISI marked anodized (anodic coating not less than grade Ac 10 as per I.S. 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper
Extra for providing lipping with 2nd class teak wood battens 25mm minimum depth on all edges of shutters (over all area of door shutter to be measured).
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. (Approved Brand - Doorset)
Providing and fixing bright finished brass 100 mm mortise latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete. (Approved Brand - Doorset)
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories
1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”
2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.”
3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml”
4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm”
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site
6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass (loee glass) of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Supplying, fitting & fixing local made COLLAPSIBLE GATE of approved size and make properly fabricated with vertical double channel 20 x 10 x 2 mm at 100 mm center and braced with M.S. flat diagonals 20 x 3 mm with top and bottom rail of T. iron 40 x 40 x 6 mm with 38 dia steel pulleys complete with bolt, buts locking arrangement, steppers, handles including applying a primer coat of read lead paint carriage, hoisting and taxes etc. all complete as per building specification and direction of Engineer Incharge.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for Rolling Shutters
Extra for providing mechanical device chain and crank operation for operating rolling shutters.
Exceeding 16.80 sqm in area
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer
Using M.S. angels 40x40x6 mm for diagonal braces
WATER PROOFING TREATMENT
Providing 50mm th. Cement concrete M20 (1:1.5:3) mainaining slope in alternate 2MX2M panels with approved quality of stone chips 20mm to 6mm size graded chips and cleaned sand of F.M. 2.5 to 3 including screening, shuttering and mixing of cement concrete in mixer with sadmixture of integral waterproofing and placing in position, striking, curing, texes and royality all complete as per building specificationb and direction of E/I. Panels that has been left should be casted next day. There should be 6mm gap between panels. Brand - Sika - Plastocrete plus, MYK proof WP10, Fosroc-conplast X 4211C, Dr. Fixit Pidiproof LW+ or equivalent.
Providing and laying water proofing treatment on roof slab by applying two Component, factory designed ,ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps –
Surface preparation – Providing and cleaning of concrete surface to remove dust, oil grease including removal of existing loose paint/ coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. ponding test to be done after plugging all outlets and to be checked from soffit to be identify seepage, leakage. On identification of seepage, cement grouting to be done with non-shrink expanding admixture of Sika India Pvt Ltd. /MYK Schomberg / Dr. Fixit / Fosroc or equivalent. Providing and repairing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150 mm x 150mm fillet of mortar ( Cement : sand – 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg / Dr. Fixit or equivalent . Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concrete in base slab, dead cracks if any ,with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material labour tools complete.
1st Coat :- Apply 1st coat of two component acrylic modified ,ready to use, flexible cementitious material on surface saturated dry roof and inside wall of parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50/Sqmt / coat . For the purpose of measurement the entire treated surface will be measured .
c) 2nd coat :- To apply the 2nd coat of two component acrylic modified ready to use ,flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7kg/Sqmt/coat. For the purpose of measurement, the entire treated surface will be measured.” After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Waterproof Brand :- Sika Top seal 109hi /Fosroc Brush bond RFX/ Dr. Fixit Pidiffin 2 k / MYK Aquafin TG . Product Performance – Chemical Base Part A: Acrylic copolymer. Part B : Specially graded cementitious powder – Density 1.6kg/l (mixed density) at +27c Tensile Strength – 2 N/mm2 after 28 days ( with Fibre cloth) ( According to ASTM D 2370 ) Pullout Bond Strength – 2 N/mm2 ( concrete failure ) ( According to ISO 4624 ) Slant – SheAR Bond Strength – 4 N/mm2 ( According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth ( According to ASTM D 2370)
Protection of treated surface with PCC:- The treated surface should be covered with 25mm /50mm PCC of M- 20 GRADE (1:1:5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2 mt x 2 mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the screed concrete ( paid separately for this items) All corners shall be chamfered with 150 mm X 150 MM FILLET . The rainwater outlets shall be just levelled with the screed concrete to ensure smooth discharge of water – the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epxy putty of Sika India Pvt Ltd. / MYK schomberg / Dr. Fixit / Fosroc. For the purpose of measurement the entire treated surface will be measured .”
Groove of PCC surface should be filled with polysulphide Sealant.(paid Separately) Brand – Sika India Pvt Ltd. / MYK Schomberg / Dr. Fixit/ Fosroc. Warranty for five years.
Cover ing of treated surface with PCC:- Providing 25 mm thick cement Concrete M 20 (1:1:5:3) maintaining slope in alternate 2 mt x 2 mt panels with approved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F.M 2.5 to 3 including screening , shuttering and mixing cement concrete in mixer with admixture of integral water proofing and placing in position ,striking curing taxes and royalty all complete as per building specification and direction of E/I . Panels that has been left should be casted next day. There should be 6 mm gap between panels Brand – Sika – Plastorcrate plus, MYK proof WP 10, Fosroc – Conplast X 421ic Dr. Fixit Pidiproof LW+
Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant ( Poring Grade) as per drawings and technical specifications and direction of Ein Charge (with 18% GST) Brand – Sika Polysulphide Fosroc – Thioflex 600, Dr. Fixit Pidiseal PS ( 42p) , Myk Seal PS or Equivalent. (WORKS TO BE DONE BY REGISTERED APPLICATOR OF DR. FIXIT/ PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roof terraces etc. consisting of following operations.
Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS : 2645 over the RCC slab including cleaning the surface before treatment.
Laying cement concrete using broken bricks/brick bats 25 mm to 100 mm size with 50% of cement mortar of mix 1:5 ( 1 cement : 5 coarse sand ) admixed with proprietary water proofing compund conforming to IS :2645 over 20 mm thick layer of cement mortar 1:5 (1 cement : 5 coarse sand ) admixed with proprietary water proofing compund conforming to IS :2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs
After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS: 2645.
Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand ) admixed with proprietary water proofing compund conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300X300 mm square.
The whole terrace so finished shall be flooded with water for minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the E/I.
With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
(WORKS TO BE DONE BY REGISTERED APPLICATOR OF DR. FIXIT/ PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Providing tuck pointing [1:3] in cement on brick work clean coarse sand of F.M 1.5 FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 12mm cement plaster(1:3) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 1.5 mm th. cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Providing applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth copmlete .
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I
Providing two coat of snowcem of approved shade and make over a coat of cement of primer on new surface including preparing the plastered surface smooth with sand paper, soaping, curing and taxes all complete as per building specification and direction of E/I.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete.
Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm
Providing two coats of SYNTHETIC ENAMEL PAINT of approved shade and make over new WOODEN surface including cleaning the surface after removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification dirction of E/I.
Providing Primer one coat of read lead paint of approved make over new STEEL SURFACE preparing the surface after cleaning, removing rust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
Colour washing two coats over a coat of white wash over new surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales of smoke and mosh marks with jhama rubbing, scaffolding specification and direction of E/I
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners, etc.)
Providing & fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
Providing & fixing on wall face unplasticised -P.V.C. moulde fittings / accessories for unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion .
Coupler - 110 mm
SHOE - 110MM
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 MM
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.
The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7), (Approved Brand - Armstrong)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recomme-nded jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer-in-charge :
With Type SE - Self Extinguishing type 50 mm thick
Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : (Approved Brand - Tata Bluescope/ Equivalent)
12.51.2 Flashings/ Aprons.( Upto 600 mm)
12.51.6 Gutter (600 mm over all girth)
Making Soak Pit 2.5 m diameter 3.0 meter deep with 45x45cm dry briick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standerd design .
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and filling in position bitumen mix filler of proportion 80 kg. of hot bitumen, 1 kg. of cement and 0.25 cubic metre of coarse sand for expansion joints.
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete.
1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.
80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Supplying and fixing C. I. Cover without frame for MANHOLE. 560MM DIA C.I. COVER (HEAVY DUTY)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910, on 12 mm dia steel bar confirming to IS: 1786, having minimum cross section as 23 mmX25mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protuded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in tank with 30X20X15 cm cement concrete complete as per design.
DT: Basic rates for 125/115 mm dia Drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH ring Machine all complete including supplying all meterial, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of engineer-in-charge. (Basic rates)
(i) Drilling up to 30 mtr. Depth below G.L. in Rural Area
Supplying, assembling, lowering and fixing in vertical position in borewell unplasticized PVC medium well screen (RMS) pipes with ribs, confirming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of engineer-in-charge.
100 mm nominal size dia. -
Supplying,filling, spreading and levelling stone boulders of of size range 5cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.
Supplying,filling, spreading and levelling gravels of size range, 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in the required thickness, for all leads and lifts, all complete as per direction of E/I.
Constructing brick masonary chamber for Underground C. I. Inspection Chamber and bend with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. Cover with frame (light duty) 455X610 mm internal dimensions, total weight of cover with frame to be not less than 38 KG. (weight of cover 23 kg. and weight of frame 15 kg) RCC top slab with 1:1.5:3 mix (1 cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 mix (1 cement:5 coarse sand :10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm th. with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
Inside dimensions 455X610X mm and 45 mm deep for single pipe line with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete.
150 MM dia R.C.C. pipe
250 MM dia R.C.C. pipe
Supplying fitting and fixing Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm (2'-0"x2'-0"*2) in position as per specification and direction of E/I.
200/150 mm dia Deep borewell : Cost of drilling 200 mm X 165 mm X 125m deep brewell in all kinds of soil and rock in rural area for installation of pump set with Hydraulic DTH Rig machine, all complete including supplying all all materials, tools drilling rig, Air compressure and equipments, as well as fuel, lubricants and cost of transportation of Rig machine and other vehicle up to the site.
From 0.00 M to 50.00 M below G.L
From 51.00 M to 125.00 M below G.L
From 125.00 M to 200.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
200mm Nominal size dia.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm Dia.
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
Supplying 100mm dia. Submersible pump sets confirming to IS 8034 and motor cvonfirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft ant polypropylene/ norylimpeller. Motor suitable for working on 415 V+10%, 3PH, 50 HZ, AC supply with cable guard, thurst carbon/ fibre bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined no return valve shall be provided with pump. 3 m submersible copper conductor cable in single/ double run and nylon rope as required length shall be provided with each pump.
Submersible pump set 100mm dia (with polypropylene/ Noryl Impeller) 2 HP
Supplying and laying /lowering of GI pipe of 50 mm dia including of required fittings solvent etc complete job as per direction of E/I
CARRAIGE OF MATERIALS
LOCAL SAND, LEAD - 8 KM.
COARSE SAND , LEAD - 30 KM.
STONE CHIPS , LEAD - 8 KM.
STONE METAL , LEAD - 8 KM.
BRICKS , LEAD- = 15 KM.
EARTH , LEAD- = 3 KM.
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking at site dump manure from local or other approved source including royalty and cariage up to 1 km. (Manure measured in stacks will be reduced 8% for payment). Screened through sieve of I.S. designation 4.75 mm.
Rough dressing the trenched ground including breaking clods.
Fine dressing the ground
Spreading of sludge, dump manureor / and good earth in required thivkness(Cost of sludge, dump manure or / and earth to be paid seperately).
Mixing earth and sludge or manure in proportion specified or directed.
Providing and stacking of Cassia javanica of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v
Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Cassia siamea of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. as per direction of the officer-in-charge.
Providing and stacking of Eugenia jambolana (Jamun) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.as per direction of the officer-in-charge.
Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. as per direction of the officer-in-charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes joining of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL) Exposed on Wall
25mm dia
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end )
A) 25MM nominal bore
Supplying, installation, testing and commissioning ofElectric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered
Main Fire Pump 2280 lpm at 88 m Head
Jockey Pump 180 lpm at 88 m Head
Terrace Booster Pump 900 lpm at 35 m Head
For Pump room
Supply and fixing of PVC sheathed following conductor 1.1 KV grade armoured Cable of following sizes including making end termination with compression gland & bimetalic lugs, and support etc.complete as required
3 × 50 sq.mm.(aluminium)
3 × 10 sq.mm.(aluminium)
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
80 mm diameter
100 mm diameter
150 mm diameter
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
80 mm diameter
100 mm diameter
150 mm diameter
Pressure Gauge Assemble with Gate/Ball Valve
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing, laying, testing & commissioning of IS 1239 marked black M.S pipe including all fittings i.e bend, elbows, tees, flanges, reducing socket, nuts and bolts, gaskets etc fixed with welded / screwed joints. including necessary excavation, backfilling, removal of surplus soil etc. min. 1 mtr deep excavation and wrapping with anticorrosive treatement with 4 mm thick asphalt tape as per IS:10221, refilling the trench etc. OR fixed with screwed or welded joints, hanged with clamps, hanger supports, dash fasteners, bolts, nuts, rubber insertions etc including threading, cutting, welding, edge preparation, painting of approved colour over two coat of primer, cutting & making good the wall/ floor wherever required, complete as required or as directed by engineer incharge. Make:Tata/Nezone/Jindal
150 mm diameter
100 mm diameter
80 mm diameter
25 mm diameter
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Stainless steel
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Gun Metal
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Gun metal
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
4 way - 150 mm dia M.S. Pipe
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Two Loop Panel.
SANITARY & WATER SUPPLY
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast iron P or S trap, 10 litre low level white P.V.C. Flushing cistern with munally controlled device (handle lever) conforming to IS:7231 Parryware/ Hindware with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
White Vitreous China Orissa pattern W C pan of size 580 X 440 mm with integral type foot rest.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled devicde (handle lever), conforming to IS:7231, parryware/Hindware/with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing C.P. brass bib cock of approved conforming to IS 8931
15mm nominal bore approved brand C.P. fittings
Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 690gms.
15mm nominal bore approved brand C.P. fittings
Providing and fixing C.P Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
Providing and fixing C.P. brass angle valve for basin mixer, gyser & others points of approved quality conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china flat back half stall urinal of 580X380X350mm with white PVC automatic flushing cistern, parryware/Hindware with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass with waste fitting as per IS : 2566 P.V.C. trap with outlet grating and other couplings in C.P. brass including parenting of fitting and cutting and making good the walls and floors wherever required..
Single half stall urinals without 5 litre P.V.C. auotmatic flushing cistern
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end )
32MM nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete.
25mm nominal bore
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT grating of approved quality and colour.
18.58.2 Rectangular type with openable circular lid 18.58.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating
Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S.13983 with C.I. Brackets stainless steel plug 40mm including painting of fittings and brackets cutting and making goods the walls wherever required:
17.10.2 kitchen sink without drain board
17.10.2.1. - 610x510mm bowel depth 200mm
17.10.2.2 610x460 mm bowl depth 200 mm
Providing and fixing C.P.brass long nose bib cock of approved quality conforming to standard and weight not less thain 810gms.
15mm nominal bore approved brand C.P. fittings
Providing and fixing unplasticised P.V.C. connection pipe with c.p. nuts collar and bush of approved quality.
15 mm nominal bore with 45 cm length.
Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible Pipe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I.(Approved Brand - ASTRAL/ SUPREME)
Concealed work including cutting chases and making good the wall etc..
15mm dia
20mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL)
Exposed on Wall
25mm dia
32 mm dia.
Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete.
150 MM dia R.C.C. pipe
250 MM dia R.C.C. pipe
Constructing brick masonary chamber for Underground C. I. Inspection Chamber and bend with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. Cover with frame (light duty) 455X610 mm internal dimensions, total weight of cover with frame to be not less than 38 KG. (weight of cover 23 kg. and weight of frame 15 kg) RCC top slab with 1:1.5:3 mix (1 cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 mix (1 cement:5 coarse sand :10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm th. with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
Inside dimensions 455X610X mm and 45 mm deep for single pipe with F.P.S. bricks
Providing and fixing C.P. brass Health Faucet (Telephonic shower with flexible pipe) including 450 mm long Braided Hoses with all fittings complete job.
Hand Shower - CAT. NO. - JAQUAR, ALD - 573
Providing and fixing C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer.
ELECTRICAL
Wiring for light point/fan point/exhaust fan/call bell point with 1.5 sqmm PVC insulated copper conductor cable in surface / recessed PVC conduit with moduler type switch,moduler plate,suitable size GI box etc. as required .
Wiring for twin control light point with 1.5 sqmm PVC insulated copper conductor cable in surface / recessed PVC conduit with moduler type switch,moduler plate,suitable size GI box etc. as required .
Wiring for light/power plug with 2 x 1.5sqmm. PVC insulated, copper conductor single core cable in surface / recessed PVC conduit along with 1 no 1.5 mm PVC insulated copper wire for loop earthing as required.
Wiring for light/power plug with 2 x 4 sqmm. PVC insulated, copper conductor single core cable in surface / recessed PVC conduit along with 1 no 4.0 mm PVC insulated copper wire for loop earthing as required.
Wiring for light/power plug with 4 x 4 sqmm. PVC insulated, copper conductor single core cable in surface / recessed PVC conduit along with 2 no 4.0 mm PVC insulated copper wire for loop earthing as required.
Wiring for submain wiring with the following size of PVC insulated, copper conductor single core cable in surface / recessed PVC conduit as required:
2x1.5 sq.mm.+1x 2.5 sq mm(for 5A Switch Socket)
2x2.5 sq.mm.+1x 2.5 sq mm(for switch board / 5A Switch Socket+AC IDU)
2 x 4 sq.mm+1x4 sq mm. (for 20A Metal clad socket)
4 x 6+2x6 sq.mm. (Sub-Mains+c/ac)
4 x 10 +2x10 sq.mm. (Sub-Mains)
Supplying and drawing following sizes of PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit / PVC casing capping / as required.
2x1.5 sq mm
3x2.5 sq mm
Supplying and fixing suitable size GI box with moduler plate cover in the front on surface or in recess including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps. moduler type switch, connections painting etc. as required. (For light plugs).
Supplying and fixing suitable size GI box with moduler plate cover in the front on surface or in recess including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps. moduler type switch, connections painting etc. as required. (For power plugs).
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' catagory, miniature circuit breaker (10 KA) of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
single pole(6 to 32A)
Single Pole and Neutral 6/32A
6/32 Amp TPN MCB-10KA
40 amps.TPN
63 amps. TPN
25/100A MCCB FP MCCB
Providing and fitting Digital Timer and controller and 60A 4 Pole with all complete.
Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker with overload protection(RCBO), having a sensitivity current upto 300 milli Amp. In the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with two poles and earth metal enclosed plug top along with 20 amps. "G" series, SP MCB (10 KA) in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts,on surface /recess, complete with tinned copper bushbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing etc. as required.
4way(4+12)double door (Horizontal type)
6 way(4+18)double door (Horizontal type)
8 way (4+24)double door (Horizontal type)
12 waySPN (double door) (Horizontal type)
4 waySPN (double door for IDU/ODU AC)
8 way (8+24)double door (Vertical type)
Providing and fixing M.V. danger notice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription signal red colour on front side as required.
Suppyling and drawing co-axial TV cable RG-6 grade cable in the existing surface / recessed steel / PVC conduit as reqd.
Supplying and drawing following pair 0.5 sq. mm FR PVC insulated annealed copper conductor unarmoured telephone cable in the existing surface/recessed PVC conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed PVC conduit as required.
1 run of cable
2 run of cable
3 run of cable
S/F following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc.as required.
5/6 amps one way switch
15/16 amps one way switch
5/6 amps 3pin socket outlet
Telephone socket outlet
TV antenna socket outlet
Supplying and fixing modular stepped type fan regulator
Supplying and fixing modular type blanking plate
Supplying and fixing following sizes /modules G.I box along with modular base and cover plate for modular switches in recess etc as required.
1 or 2 module
Supplying and fixing ding dong call bell
Supplying and fixing of following sizes of PVC conduit alongwith the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required .
20 mm PVC coduit.
25 mm PVC coduit.
Providing, laying , testing and commissioning of 80 mm *3 mtr earth electrode with camical powder for earthing work. masonry chamber with concrete base CI/ heavy duty chequered plate. mixtures of soil & camical powder around earth electrode including digging of pit upto permanent moisture level and as per soil condition but not less than 3 meters and back fill compound chemical 4 bag(per bag 25 kg)
Providing and fixing 25mm x 5mm Copper strip on surface or in recess for connection etc as required.
Earthing with GI earth pipe 4.5 m long x 40 mm dia. including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc, (but without charcoal or coke and salt ) complete as required.
Earthing with Copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc (but without charcoal or coke and salt) complete as required.
Supplying and laying 6 SWG G.I wire at 0.50 mtr below ground level for conductor earth electrode ,including soldering etc as required.
Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long GI tube, having single prong at top, with 85 mm fia 6 mm thick base plate including holes etc complete as required.
Rivetting, sweating and soldering of copper/GI Tape (with another GI Tape, base of the finial or any other metallic object) as required.
Providing and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lighting conductor as required (for horizontal run).
Providing and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lighting conductor as required (for vertical run).
Providing and fixing testing joint, made of 20mm x 3mm thick copperstrip, 125mm long, with 4 Nos of brass bolts, nuts, check nuts and spring washers etc complete as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required :
4 x 16sq. mm.
3-1/2 x 35 sq. mm.
3-1/2 x 185 sq. mm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade. Direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Of size not exceeding 25 sq.mm.
Of size exceeding 25 sq. mm.but not exceeding 120 sq. mm.
Of size exceeding 400 sq. mm but not exceeding 400 sqmm.
Supply of ISI marked (IS : 7098 Pt-I) aluminium conductor XLPE Insulated armoured, served, sheathed cable 1100 volts grade.
4 x 16sq. mm.
3-1/2 x 35 sq. mm.
3-1/2 x 185 sq. mm.
Supplying Cable Route Marker with 10 cm x 10 cm x 5mm thick GI Plate with inscription thereon, bolted/welded to 35mm x 35mm x 6mm angle iron, 60 cm long and fixing the same in ground as required.
MAIN DISTRIBUTION BOARDS / L.T. PANEL.
LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMING (1- sets) each with following:
250 Amp, MCCB FP with built-in static realease-3 no, 100 Amp, MCCB FP with built-in static realease-1 no, Electronic Relay 2-OC+1-EF, Ammeter, ASS, CTs, Voltmeter, VSS, Fuses, Frequency Meter, 3 Sets of Phase Indicating Lights with fuses & following accessories: - 1 set,250A changover TPN (ON-LOAD)-2nos.,
BUS BARS
a)3 sets of 300 Amp, 415V, 3 phase, 50 Hz TPN copper bus bars.
OUTGOING
a)1 Nos of 150 Amp FP MCCB, Varible settings
b)14 Nos of 25/100 Amp FP MCCB, Varible settings
LT Panel (Normal) as above
250A MCCB FP
250A MCCB FP (for Capacitor panel)
160A MCCB FP
300A BUSBAR
25/100A MCCB FP
250A C/O FP
DIGITAL VOLT METER 500V(3phase class 0.5)
DIGITAL A METER 500V(3phase class 0.5)
COPPER STRIP 32MM*6MM(1.705 KG/MTR)
COPPER STRIP20MM*3MM(0.533 KG/MTR)
COPPER WIRE 1.5MM
COPPER WIRE 6MM
LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMING (1- sets for IInd floor) each with following:
150 Amp, MCCB FP with built-in static realease-1 no,Electronic Relay 2-OC+1-EF, Ammeter, ASS, CTs, Voltmeter, VSS, Fuses, Frequency Meter, 3 Sets of Phase Indicating Lights with fuses & following accessories: - 1 set
BUS BARS
a)1 sets of 200 Amp, 415V, 3 phase, 50 Hz TPN copper bus bars.
OUTGOING
a)10 Nos of 25/100 Amp FP MCCB, Varible settings
LT Panel (Normal) as above
160A MCCB FP
200A BUSBAR
25/100A MCCB FP
SUPPLY OF LIGHTING FIXTURES & FANS
INTERNAL LIGHTING FIXTURES
Supply of incandescent wall/ceiling light fixtures with holders complete as per standard item with copper wiring as required for proper completion of the work.
Supply & installation of 28 W T5 Tube lights fittings complete set.
Supply & installation of 14 W T5 Tube lights fittings complete set.
Supply & Fixing 2*2 (36w) recess type LED flat panel.
Providing and fixing of Surface/ Recess LED light (18/20w)
P/F LED 150W Flood Light complete Set
Providing of Decorative Ceiling fans, 1200mm dia sweep
Providing of Exhaust fans, 230 mm dia
Providing of Exhaust fans, 300 mm dia
Providing of Exhaust fans, 380 mm dia
ERECTION OF LIGHTING FIXTURES ,FANS & EXTERNAL LIGHTING
INTERNAL LIGHTING FIXTURES
Installation, testing and commissioning of prewired, fluorescent fittings, of all types (1 x 14/28 watt.) complete with all accessories and tubes etc. directly on ceiling / wall, including connections with 1.5 sq.mm. PVC insulated, copper conductor, single core cable etc as required.
Installation, testing and commissioning of 1200 mm sweep ceiling fan and regulator including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq.mm. PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan upto 450 mm. sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing, commissioning etc. as required.
SUPPLY & ERECTION OF EXTERNAL LIGHTING(street light)
S/F of 7 Mtr . height octagonal Hot -Dip galvanized pole (BOP-7030) with top dia 70 mm .bottom dia 130 mm and made of 3mm thick sheet,base plate dimensions 200 76 mm dia,6.0 m long x200x12mm (LxBxT) including suitable sizes of foundation bolt, 1 Mtr long double Arm with 120w LED street light. all complete.as required
S/F of 7 Mtr . height octagonal Hot -Dip galvanized pole (BOP-7030) with top dia 70 mm .bottom dia 130 mm and made of 3mm thick sheet,base plate dimensions 200 76 mm dia,6.0 m long x200x12mm (LxBxT) including suitable sizes of foundation bolt, 1 Mtr long single Arm with 120w LED street light. all complete.as required
3x70 sq mm
Laying of one number PILC/PVC insulated and PVC sheathed / XLPE power cable of grades exceeding 1.1KV but not exceeding 11KV of following sizes direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supplying of Cable size not exceeding 120 sq mm
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and mixing of concrete floor hardener for topping in vd floor at finishing time @ 2.0kg per Sq.m, including all complete as per dorection of E/I. Approved Brand - Fosroc/ Cico)
Providing & ejecting Chemical emulsion for pre-constructional ANTI TERMITE TREATMENT and creating a chemical barrier under a alround the column pits, wall trenches, basement excavation, top surface of plinth filling junction of wall and floor along the external perimeter of building expansion joints, surrounding of pipes and conducts tic. complete(plinth area of the building at ground floor only shall be measured) with Chlorpyrifos 20% EC as per building specification and direction of E/I. (4 stages treatment)
AS / COVERED AREA OF BUILDING
Providing water proofing treatment in Retaining wall, Basement floor slab O. H. Tank with following application including all materials, labours, taxes complete, as per follwing applications. -
After the release of shuttering, repair all bug or pin hole with polymer modified mortar on the inner surface of tank +retaining wall.
Make a 20X20 groove along with the construction joint and seal the same with polymer modified mortar , specially the starter joint of the retaining wall.
Prior to apply Sika Top Seal 107 on the surface.
Apply first coat of Sika Top Seal 107 over prepared surface. Coating should be continued over the bottom portion of the tank, the coated surface air cured for at least 4 hrs
Before application of 2nd coat , surface should be wet again with the help of sprinkling water Apply second coat of Sika Top Seal 107 over the executed first coat
The coating shall be covered with 12 mm thick plaster added with waterproofing admixture Plastocrete Super 0.2% by weigh of cement with a cement – sand (1:4)
Drill hole up to half of the depth of the concrete and fix nozzles of 12 mm dia GI / NBMS nozzle 1m c/c in a grid pattern in the interior surface of retaining wall with the help of quick setting compound Sika 2.
(WORKS TO BE DONE BY REGISTERED APPLICATOR OF DR. FIXIT/ PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Providing and fixing 21" dia STAINLESS STEEL TURBO VENT in sheet roofing of best quality (approved) including all fittings and fixtures with all taxes complete job.
Supplying and fitting of standared make starter pannel board with arrangement of all necessory protection ,including all taxes , royalty etc all complete job as per direction of E/I
Supplying ,fitting & fixing & connecting 3 core 4 sqmm flat copper submerssible cable of Finolex / Hevels make including all taxes ,royalty etc all complete job as per direction of E/I
Providing and fixing pop-up 1.5" dia. Nozzle Sprinkler in garden
Fabrication, Supplying, Installation, Testing & Commissioning of electrical control panel of cubical construction, wall mounted type, fabricated out of 2mm. thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection, and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respects, suitable for operation on 415 V, 3 phase 50 HZ AC supply with enclosure protection class IP 42.
For Terrace Pump
Supply and fixing of PVC sheathed following conductor 1.1 KV grade armoured Cable of following sizes including making end termination with compression gland & bimetalic lugs, and support etc.complete as required
3 × 50 sq.mm.(aluminium)
3 × 10 sq.mm.(aluminium)
Pressure Gauge Assemble with Gate/Ball Valve
Providing and fixing of Air release Valve of ISI marked standard and approved make.
Providing and fixing 25 mm nominal gun metal gate valve class I with CI wheel of approved quality with union (Screwed end)
Supplying and fixing of hose cabinet of size 450mm x 450mm x 250mm made of 2mm thick M.S. sheet with 6mm thick glazed glass door including necessary locking arrangment suitable to accomodate 1 nos. 15 mtr. long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect.
Providing , fixing Dry Chemical Powder (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 20oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (4 Kg Capacity)
Carbon Di-oxide Type , Gas Confirming to IS ‘15222’ , Cylinder Confirming to ‘IS 7285’ & PESO approved ,Controllable Discharge Mechanism, Discharge Hose & Horn As per ‘IS 15683’ & ‘IS 2878’ ISI mark Fire Extinguishers (Wheel Type or Squeeze Grip Type). Operating Temperature :- (-)20oC to (+)55oC Suitable for ‘B’ ‘C’ Class of FIRE (4.5 Kg Capacity)
Providing , fixing Modular type Fire Extinguishers for electrical rooms (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 10oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (5 Kg Capacity)
Providing and laying 19mm dia PVC conduit complete with required junction boxes in recessed / surface system PVC insulated copper conductor cable of 2x1.5 sq.mm. in existing conduit as required. Make:Polycab/Mescab
Providing and fixing Wash basin with C.I/ M.S brackets, 15mm C.P. pillar cock 32mm C.P brass waste of cutting and making good the wtherever require all complete.
WASH BASIN - CAT. NO. - JAQUAR, CNS-WHT-705 (WITH RIM TOP)
PILLAR TAP - PRS - CHR-031
BOTTLE TRAP - CAT. NO. - JAQUAR, ALD - CHR769L 300X190
WASTE COUPLING - CAT. NO. - JAQUAR, ALD CHR - 709 L130
provding and laying of 110mm dia. P.V.C. pipe for outlet of water to outlet drain, vent pipe, etc. including all PVC fittings & accessories all complete. (Approved Brand - ASTRAL/ SUPREME)
Providing and fixing of INDICATOR LAMP with all accessories.
Providing and fixing of CRCA ENCLOSURE (16SWG).
Providing and fixing ofCRCA ENCLOSURE 16SWG (OUTDOOR)
Panel commissioning / testing Charge
Panel commissioning / testing Charge (OUTDOOR)
Providing, designing and installing PANEL: (36KA) INCOMING: (75kvar) with followings:
1 No. of 250 Amp FP MCCB with Ammeter, ASS, CTs, Voltmeter, VSS, Fuses, 3-Sets of Phase Indicating Lights with fuses. Automatic PF Correction Relay having PF meter.
BUS BARS
One set of 300 Amp , 415V, 3 phase, 50 Hz TPN Cu bus bars.
OUTGOING
a)3 Nos. of 100 Amp TP HRC Fuses with Automatic Control, Contactor of 3 Pole, 60A, Push Button for ON/OFF, ON Indicating Lights, internal control circuit etc complete each for3 Nos, 20 KVAR Capacitor Unit with MPP capacitor complete.
b)4Nos. of 40 Amp TP HRC Fuses with Automatic Control, Contactor of 3 Pole, 32A, Push Button for ON/OFF, ON Indicating Lights, internal control circuit etc complete each for 4 Nos, 10 KVAR Capacitor Unit with MPP capacitor complete.
Auto Capacitor Panel as above: 100 KVAR
Notes:
Ammeter, Voltmeter & Frequency Meter shall be of 96x96mm flush type, panel mounting
All MCCBs & busbars shall be of minimum fault rating as indicated for panel with O/L & Short cicruit Protection Devices with variable settings.
All MCBs shall be of minimum 15 KA fault rating with O/L and Short Circuit Protection devices
All busbars shall of electrolytic aluminium grade with heat shrinkable sleeves covering.
All MCCBs shall be with rotary handle.
HT SECTION:
Supply, installation, testing and commissioning of Oil Cooled, ONAN, 11000V/415V, +/- 2.5/7.5% regulation in steps if 2.5% as standard practice, 100 KVA capacity complete with all standard accessories with both sides cable end boxes, temperature indicator, Buchholz Relay, Oil Conservator, breather etc complete.(outdoor type)
Supply of HT, 11000V XLPE Aluminium conductor, Armoured cable in following sizes:
3x70 sq mm
Fire Bucket 3 Nos on one bracket frame / stand as required at site with fine sand painted red complete as required.
Safety Charts complete on teak wood frame and 10mm ply in back and 6 mm thick glass complete including supply and hainging on wall.
Fire extinguishers dry type CO2 4.5Kg including supply and installation in charged condition.
Fire extinguishers Water type CO2 9 Ltrs including supply and installation in charged condition.
Supply and erection of H - Pole Structure as per the requirements of the State Electricity Authorities including the cost of Poles, Brackets, 400A G/O Switch, Handle, Lock, Drop Out Fuses, Arms, Insulators, 3 Nos Lightning Arrester at 11000 volts, stays, gyes etc complete as required.
Supply and installing of 50 KVA 415 Volts (3-Phase) DG Set comprising of Cummins/ Krilosker Green/ make engine model 4B3.3TAA-G11 developing and Stamford make alternator mounted on a common base, complete with:
a) Fuel tank.
b) Batteries and leads.
c) Manual Panel.
d) Residential Silencer
e) First fill of lube oil
f) AVM Pad
h) Acoustic Enclosure
All above items are as per manufacture.
Supply of 125 KVA 415 Volts (3-Phase) DG Set comprising of Cummins make engine model 6BTAA5.9-G13 developing 159 BHP and Stamford make alternator mounted on a common base , complete with:
i) Fuel tank.
j) Battery and leads.
k) Manual Control Panel.
l) Residential Silencer
m) First fill of lube oil
n) AVM Pad
p) Acoustic Enclosure
Providing and Installing, Testing & Commissioning of 10 Passenger automatic Machine room less (MRL) Lift - 1no., including one year free maintenance which will be start from handing over the lift, all taxes and all complete as per following detail specifications. APPROVED BRAND - Johnson/ Otis.
Type of Lift - SUKRANTI - MR - C - PASSENGER (MRL)
Load/ Speed - 10 Person (680 Kg)/ 1.25 m/ Sec
Drive - Microprocessor Based VVVF
Nos. of Floor - 3 (G+2)
Floor Display chart - 0,1,2
Number of Landing entrances - 3 (G+2)
Number and Position of Car Entrances - 1 (One) in Front only
Position of Machinary - MACHINE ROOM LESS - GEARLESS
Lift Car inside size - 1000x1700x2200 mm
Clear opening of Door - 800x2000 mm
Type of Design of Lift Car - Stainless Steel - Hairline Finish
Providing Suplying and Installing of High wall mounted Split air-conditioning Unit (5Star Rating, as approved) (all indoor and outdoor unit) of following capactity, including copper pipe (all length) for cabling, standard drainage pipe (all length) of required dia. Fixing of outdoor unit on m.s. platform as/ requirement and drawing all complete.
Providing and fixing preacast prestress M30, 1800mm Ht. Boundary wall made with 2400 ht (150x175mm) r.c.c. post and 50 mm th. 2400mmx300 size slab fixed on groove of r.c.c. post, including earthwork (2X2'X2') and fixing with P.C.C. M25 with all complete job and taxes.
Providing , fixing Dry Chemical Powder (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 20oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (4 Kg Capacity)
Carbon Di-oxide Type , Gas Confirming to IS ‘15222’ , Cylinder Confirming to ‘IS 7285’ & PESO approved ,Controllable Discharge Mechanism, Discharge Hose & Horn As per ‘IS 15683’ & ‘IS 2878’ ISI mark Fire Extinguishers (Wheel Type or Squeeze Grip Type). Operating Temperature :- (-)20oC to (+)55oC Suitable for ‘B’ ‘C’ Class of FIRE (4.5 Kg Capacity)
Providing , fixing Modular type Fire Extinguishers for electrical rooms (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 10oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (5 Kg Capacity)
Providing and fixing 25 mm nominal gun metal gate valve class I with CI wheel of approved quality with union (Screwed end)
Supplying and fixing of hose cabinet of size 450mm x 450mm x 250mm made of 2mm thick M.S. sheet with 6mm thick glazed glass door including necessary locking arrangment suitable to accomodate 1 nos. 15 mtr. long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect.
For Terrace Pump
Air release Valve
Providing and laying 19mm dia PVC conduit complete with required junction boxes in recessed / surface system PVC insulated copper conductor cable of 2x1.5 sq.mm. in existing conduit as required. Make:Polycab/Mescab
Add 12 % GST
Add 1% Labour Cess
M/S ADARSH CONSTRUCTION
M/s Raj Construction
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
BOQ_61533.xls
BOQ • 0.58 MB
SBD-13.pdf
Tender Documents • 3.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .