Supply, Installation, Testing & Commissioning of VRF Air Conditioning System, Internal Electrical Works and Associated Power Infrastructure for Indoor Stadium at CLW Township.
EL-CON-513~CLW
EL-CON-513
Open
Works - General
6 Months
Uttara Kannada, Karnataka
₹0
₹2.5 L
9 Jan 2026
18 Dec 2025
26 Dec 2025
01-% above/ below/ at par of NS items of schedule 19992700.49 Below/P
Item Breakup - 01-% above/ below/ at par of NS items of schedule
Supply, commissioning of modular type Variable Refrigerant Flow (VRF)/Variable Refrigerant Volume (VRV) air-cooled Outdoor Unit(s) of 24.0 HP capacity, comprising minimum two high-efficiency inverter scroll compressors per unit, suitable for operation with R-410A or equivalent refrigerant, top discharge type, factory charged with first charge of refrigerant, and fitted with microprocessor- based control system. The unit shall be suitable to work on 400V ±10%, 3 Phase, 50Hz AC supply and should operate reliably at ambient temperature of up to 52°C without tripping. The Outdoor Unit (ODU) shall include: (i) Scroll inverter compressors with frequency variation from 11Hz to 110Hz, with precise 0.1Hz step inverter control. (ii) External static pressure not less than 85 Pa for ODU fan. (iii) Integrated accumulator and oil separator. (iv) Anti-corrosion coated condenser coil. (v) Provision for BMS connectivity and duty rotation. (vi) Complete with vibration isolators, supports, fixing hardware, interconnecting piping connections, and other necessary accessories for installation. ODU shall be installed on a properly constructed brick pedestal (plinth) with anti-vibration pads, grouting, and necessary foundation as required, including civil works.
Supply, commissioning of 4.0 HP capacity mid-static ductable type Indoor Unit suitable for Variable Refrigerant Flow (VRF) / Variable Refrigerant Volume (VRV) system, delivering a minimum 1170 CFM airflow with external static pressure of not less than 45 Pa, suitable for operation on 230V ±10%, 50Hz, single-phase AC supply. The scope includes: (i) Indoor unit equipped with DX copper coil, electronic expansion valve, multispeed blower, washable filter, drain pan, and corded remote controller. (ii) Suspension from ceiling using MS angle/channel with vibration isolators and required hardware (iii) Refrigerant and drain piping connections, electrical terminations (iv) Testing and commissioning of the unit as per manufacturer's specifications at standard inlet air conditions (27°C DB / 19°C WB)
Supply, fixing, testing, and commissioning of Numbers Cordless Remote Control Unit compatible with VRF/VRV indoor units, suitable for wireless operation and integrated control of fan speed, temperature, mode selection, swing, and timer functions. The scope includes: (i) Supply of OEM-approved cordless remote controller with wall mounting arrangement (if applicable). (ii) Integration with indoor unit and configuration for proper communication. (iii) Functional testing and commissioning as per manufacturer specifications. Complete in all respects as required for proper operation of the indoor unit. ELOCO-SHOP-CLW-ELECTRICAL/CLW
Supply, fixing, testing, and commissioning of Each factory-fabricated refrigerant distribution joints (Y-joints and piping connection kits), suitable for use with R-410A or equivalent refrigerant in VRF/VRV systems, for branching between one outdoor unit and multiple indoor units. The work includes: (i) Supply of copper Y-joints/piping kits complete with closed-cell insulation. (ii) Installation and connection to main and branch refrigerant piping with proper alignment and slope. (iii) Brazing, pressure testing, nitrogen purging, and vacuum testing. (v) Finishing of joints with thermal insulation as per OEM specifications. (vi) Commissioning of the jointed piping network in accordance with manufacturer recommendations All work to be executed as per standard engineering practices and approved layout drawings.
Supply of 44.5 mm outer diameter soft/hard RM drawn copper refrigerant piping, suitable for VRF/VRV air-conditioning systems, conforming to ASTM B280 or equivalent, complete with 19 mm thick Class 'O' closed- cell nitrile rubber insulation, suitable for an operating temperature range of -40°C to +105°C.
Supply of 38.1 mm outer diameter soft/hard RM drawn copper refrigerant piping, suitable for VRV/VRF air-conditioning systems, conforming to ASTM B280 or equivalent, complete with 19 mm thick Class 'O' closed- cell nitrile rubber insulation, suitable for an operating temperature range of -40°C to +105°C.
Supply of 31.75 mm outer diameter soft/hard RM drawn copper refrigerant piping, suitable for VRV/VRF air-conditioning systems, conforming to ASTM B280 or equivalent, complete with 19 mm thick Class 'O' closed- cell nitrile rubber insulation, suitable for an operating temperature range of -40°C to +105°C.
Supply of 28.6 mm outer diameter soft/hard Metre drawn copper refrigerant piping, suitable for VRV/VRF air-conditioning systems, conforming to ASTM B280 or equivalent, complete with 19 mm thick Class 'O' closed- cell nitrile rubber insulation, suitable for an operating temperature range of -40°C to +105°C.
Supply of 25.4 mm outer diameter soft/hard Metre drawn copper refrigerant piping, suitable for VRV/VRF air-conditioning systems, conforming to ASTM B280 or equivalent, complete with 13 mm thick Class 'O' closed- cell nitrile rubber insulation, suitable for an operating temperature range of -40°C to +105°C.
Supply of 22.2 mm outer diameter soft/hard RM drawn copper refrigerant piping, suitable for VRV/VRF air-conditioning systems, conforming to ASTM B280 or equivalent, complete with 13 mm thick Class 'O' closed- cell nitrile rubber insulation, suitable for an operating temperature range of -40°C to +105°C. ELOCO-SHOP-CLW-ELECTRICAL/CLW
Supply of 19.05 mm outer diameter soft/hard RM drawn copper refrigerant piping, suitable for VRV/VRF air-conditioning systems, conforming to ASTM B280 or equivalent, complete with 13 mm thick Class 'O' closed- cell nitrile rubber insulation, suitable for an operating temperature range of -40°C to +105°C.
Supply of 15.9 mm outer diameter soft/hard RM drawn copper refrigerant piping, suitable for VRV/VRF air-conditioning systems, conforming to ASTM B280 or equivalent, complete with 13 mm thick Class 'O' closed- cell nitrile rubber insulation, suitable for an operating temperature range of -40°C to +105°C.
Supply of 12.7 mm outer diameter soft/hard RM drawn copper refrigerant piping, suitable for VRV/VRF air-conditioning systems, conforming to ASTM B280 or equivalent, complete with 13 mm thick Class 'O' closed- cell nitrile rubber insulation, suitable for an operating temperature range of -40°C to +105°C.
Supply of 9.35 mm outer diameter soft/hard RM drawn copper refrigerant piping, suitable for VRV/VRF air-conditioning systems, conforming to ASTM B280 or equivalent, complete with 13 mm thick Class 'O' closed- cell nitrile rubber insulation, suitable for an operating temperature range of -40°C to +105°C.
Fixing, testing, and commissioning of the RM supplied soft/hard drawn copper refrigerant piping for VRV/VRF system, including proper layout, leveling, supporting with hangers/clamps, leak testing, nitrogen pressure testing, dehydration, and ensuring system integrity. Applicable to the following outer diameters: 44.5 mm, 38.1 mm, 31.75 mm, 28.6 mm, 25.4 mm, 22.2 mm, 19.05 mm, 15.9 mm, 12.7 mm, and 9.35 mm, complete with pre-installed nitrile rubber insulation.
Supply of 2 Core x 1 sq.mm shielded copper RM control cum transmission cable, suitable for communication between VRF/VRV outdoor and indoor units, including flexible PVC conduit, as required for looping and interconnection, conforming to relevant IS/IEC standards.
Fixing, testing, and commissioning of 2 Core x RM 1 sq.mm shielded copper control cum transmission cable, including laying through conduit, connection between VRF/VRV outdoor and indoor units, continuity check, insulation resistance testing, and ensuring proper communication functionality, complete as required.
Supply of 40 mm outer diameter UPVC pipes RM with necessary fittings, joined using solvent cement, including cutting to required lengths, suitable for VRF/VRV drain piping applications, complete with 9 mm thick Class 'O' closed-cell nitrile rubber insulation, suitable for an operating temperature range of -40°C to +105°C. ELOCO-SHOP-CLW-ELECTRICAL/CLW
Supply of 32 mm outer diameter UPVC pipes RM with necessary fittings, joined using solvent cement, including cutting to required lengths, complete with 9 mm thick Class 'O' closed-cell nitrile rubber insulation, suitable for drain piping in VRF/VRV systems.
Installation, fixing, and jointing of UPVC pipes RM and fittings (Item No. 22-23) with solvent cement joints, including cutting to required lengths, supporting with hot-dip galvanized brackets and GI U-bolts, alignment, and leak testing, complete as required for proper drainage in VRF/VRV systems.
Supply of powder-coated extruded aluminum Sqm supply air grilles, with fixed or adjustable blades, suitable for ceiling or wall mounting in air-conditioning systems, complete with mounting frame and accessories, as required.
Fixing and commissioning of powder-coated Sqm extruded aluminum supply air grilles (Item No. 25), including alignment, mounting with necessary fasteners, sealing for air tightness, and ensuring proper air distribution as per design requirements.
Testing and commissioning of the complete Job VRV/VRF air-conditioning system, including vacuumization, nitrogen pressure testing, leak detection, and trial run of all connected indoor and outdoor units, ensuring performance parameters as per manufacturer's specifications and to the satisfaction of the Engineer-in-Charge.
Supply of additional R410A refrigerant for Kg VRV/VRF air-conditioning systems, including transportation, handling, and safe storage as per applicable standards and manufacturer's specifications.
Supply, Fixing and commissioning of 20A Each power unit, comprising a 4-module plate, 20A starter, 20A socket, and 25A plug, pre-wired and suitable for heavy-duty power connections, complete with mounting accessories, conforming to IS/IEC standards or equivalent.
Supply of 4 pole 63A MCB 10kA, suitable to Each operate 230V/50Hz AC with SS encloser. All required materials as per site condition.
Surface wiring for drawing of main service Metre line using 2 run of 6.0 sq.mm (Phase & Neutral) PVC insulated, FR-LSH copper conductor wires, along with 1 run of 2.5 sq.mm PVC insulated, FR-LSH copper conductor as continuous earth wire, laid through heavy-duty rigid plain PVC casing- capping or conduit pipe, including all accessories, saddles, bends, junctions, cutting, fixing, clamping, etc., complete as required for proper installation.
Supply, fixing, and commissioning of 4-Pole, Numbers 630A, 50kA MCCB with Thermal-Magnetic Release, housed in a suitable sheet steel enclosure, including all necessary mounting accessories, interconnections, hardware, and terminations, complete as required and conforming to relevant IS/IEC standards. ELOCO-SHOP-CLW-ELECTRICAL/CLW
Supply, fixing, and commissioning of factory- Numbers fabricated, wall/floor-mounted, dust and vermin-proof LT panel made of CRCA sheet, comprising the following: Incoming: 2 Nos. 4- Pole, 400A, 50kA MCCBs Outgoing: 6 Nos. 4- Pole, 250A, 25kA MCCBs, 6 Nos. 4-Pole, 100A, 18kA MCCBs The panel shall include electrolytic copper bus bars, neutral link, earth bar, suitably rated CTs, voltmeter, and ON/OFF indication lamps for each feeder. All MCCBs/MCBs and components shall conform to relevant IS/IEC standards. Complete with interconnections, accessories, labeling, earthing, testing, and commissioning as required.
Supply, fixing, testing, and commissioning of Numbers 8-Way TPN (Triple Pole and Neutral) Distribution Board, surface/recessed type, sheet steel, dust and vermin proof, powder coated, with lockable cover, suitable for multiple outgoing cables of various sizes. Complete with neutral link, earth bar, mounting accessories, interconnections, and all required materials, conforming to relevant IS/IEC standards.
Supply, fixing, testing, and commissioning of Each MCB Protected Power Board consisting of 25A Double Pole MCB for protection against overload and short circuit, complete with industrial-type socket outlet, enclosure, wiring, and all required materials, suitable for safe power distribution as per site requirements, and conforming to relevant IS/IEC standards.
Supply of LT XLPE insulated, armoured cable Metre with stranded aluminium conductor of size 4 core x 240 sq.mm, 1.1kV grade, conforming to IS: 7098 (Part 1), suitable for underground or overhead laying with required mechanical and electrical protection.
Supply of LT XLPE insulated, armoured cable Metre with stranded aluminium conductor of size 4 core x 150 sq.mm, 1.1kV grade, conforming to IS: 7098 (Part I), suitable for underground or surface laying, with adequate mechanical protection and electrical performance as per standards.
Supply of LT XLPE insulated, armoured cable Metre with stranded aluminium conductor, size 4 core x 50 sq.mm, 1.1kV grade, conforming to IS: 7098 (Part I), suitable for underground or surface installation, with required electrical and mechanical protection.
Laying of cable(s) on wall or structure through Metre PVC casing pipe with accessories, or as per site conditions, using suitable clamps, saddles, and fixtures, including necessary termination, connection, and testing, complete as required for proper and safe installation.
Laying of cable/cables underground along Metre roads in a trench of minimum 0.40 m wide and 1.0 m deep, including excavation in all types of soil, laying of cables over a bed of sand, covering with protective bricks, backfilling with excavated soil, compaction, surface restoration, and necessary termination, connection, and testing, complete as required. ELOCO-SHOP-CLW-ELECTRICAL/CLW
Execution of micro-drilling/boring work and Metre laying of cables underground, including mobilization of all tools, equipment, and machinery, cable pushing/pulling, placement in ducts or sleeves, and reinstatement of surface as required, ensuring proper alignment, depth, and safety standards, complete in all respects.
Supply, maintenance-free Earth Cone-type electrode with factory-filled conductive compound, complete with heavy-duty sump box (FRP/RCC with cover), interconnecting clamps, earth strip/wire, and backfilling using earthing enhancement material. All works including excavation, installation, and testing to be carried out as per IS: 3043 and relevant standards, complete in all respects. Total 13967210.80 Item- 02 Item wise breakup of schedule-II(Internal Electrical Works) S No. Item Description of Item Unit Qty Rate Amount No
Design, Installation,Testing and commissionig of high- quality 350W outdoor LED floodlight with durable ADC12 die-cast aluminum housing (55 micron polyester powder coated), separate optical and control gear compartments with IP66 & IK08 rating, 360° rotatable mounting bracket, toughened glass, silicone gaskets, visor provision for glare control, structured LED array with 130 lm/W efficacy, CRI >80, CCT 5700K, universal potted driver with 6kV surge protection, low/high voltage cutoff, auto-recovery, and external IP66 rated SPD for 10kV/5kA surge protection.
Supply and installation of 80W high-efficiency Numbers LED highbay luminaires with 150 LPW system efficacy, photo biologically safe SMD LEDs, IP66-rated pressure die-cast aluminum housing, integrated lens, built-in potted driver with APFC and surge protection, suitable for industrial use.
Design, Supply, installation, testing, and Set commissioning of indoor, pedestal-mounted, totally enclosed distribution boards with IP54 protection, suitable for 415V, 3-phase, 4-wire, 50Hz system as per load design. (2 nos for two rows of luminaires)
Supply of 3C x 2.5 sq.mm copper PVC Metre insulated flexible cable as per IS 694 for connections from HMLDB to Driver JB input side and HMLDB to AOL.
(i) Earthing installation using 50 mm dia ISI Job (M) GI pipe (3.64 mm thick, 3.04 m long) with 4 SWG hot-dip GI wire (4 m long), GI bolts, nuts, washers, and 15 mm dia GI pipe protection (1 m long) filled with bitumen, driven to 3.65 m depth as per IS standards. (ii) Excavation for Earth Electrode installation, including soil filling and ramming for soft soil conditions. (iii) Connection of equipment body to earth busbar using 50mm x 6mm hot-dip galvanized MS flat with GI saddles, including drilling and fastening with bolts, nuts, and washers ELOCO-SHOP-CLW-ELECTRICAL/CLW
Support for aiming floodlights to achieve Set required lux levels, including tightening and aligning fasteners/nut bolts as per lighting design expert's instructions. Supply of necessary hardware, fasteners, nylon ropes, and markers for grid marking. Note: final lux compliance is the design expert's responsibility.
Cutting of channel on the wall 75 mm deep Metre with suitable wide for laying of PVC conduit/Alkathine pipe 25 mm dia. (Medium Gauge) of ISI marked for concealed wiring and make good by replastering with cement sand (1:4) then putty and painting of wall similar to match surrounding paint.
Supply, commissioning of 2 runs of 1 core 6 Sq mm PVC insulated unsheathed (Multi-strand) flame retardant with flexible bright annealed copper conductor cable conforming to IS: 694- 1990 for 1100 volt grade along with 1 core 0.75 Sq mm PVC insulated earth continuity conductor cable run through 25mm casing caping / PVC conduit /Alkathene pipe medium gauge (For concealed conduit wiring or other work if required) including supply of casing caping/ PVC conduit /Alkathene pipe.
Supply, commissioning of 2 runs of 1 core 4 Sq mm PVC insulated unsheathed (Multi-strand) flame retardant with flexible bright annealed copper conductor cable conforming to IS: 694- 1990 for 1100 volt grade along with 1 core 0.75 Sq mm PVC insulated earth continuity conductor cable run through 25mm casing caping / PVC conduit /Alkathene pipe medium gauge (For concealed conduit wiring or other work if required) including supply of casing caping/ PVC conduit /Alkathene pipe.
Supply, commissioning of 2 runs of 1 core 1.5 Sq mm PVC insulated unsheathed (Multi-strand) flame retardant with flexible bright annealed copper conductor cable conforming to IS: 694- 1990 for 1100 volt grade along with 1 core 0.75 Sq mm PVC insulated earth continuity conductor cable run through 25mm casing caping / PVC conduit /Alkathene pipe medium gauge (For concealed conduit wiring or other work if required) including supply of casing caping/ PVC conduit /Alkathene pipe.
Supply, installation and connection of Modular Numbers 100.00 switch 6 A, 230V.
Supply, installation and connection of Modular Numbers 3 Pin socket 6A, 230 V.
Supply, commissioning of 5 in 1 Power wall socket board 6A/16A, 230V with switch, fuse, indication lamp combination unit.
Supply, commissioning of Ceiling rose 6A, 230 V PVC round block on 2 module Plastic Box with the required size of 3mm hylum sheet and connection with flexible PVC twin twisted Cu Cable to appliance.
Supply, installation and commissioning of Numbers 5''x5'' G.I. box (Junction box) with hylum sheet of suitable size to cover. ELOCO-SHOP-CLW-ELECTRICAL/CLW
Supply, erection, and connection of surface- Numbers 100.00 mounted 22W LED batten tube light fittings with polycarbonate housing and integrated electronic driver along with PVC insulated copper wire for connection as per IS:694- 1990, complete with all fixing accessories and hardware, including suitable surface or hanging arrangement for ceiling mounting as per requirement.
Supply, installation and commissioning of Numbers recessed mounting Modular Switch Board provided with flush metal 12 Module G.I Box and combined plates for requisite size including cutting of wall with supply of all materials for cement plaster finishing of damaged wall.
Supply, commissioning of 18 Module G.I. Box with modular Combined plate including supply of fixing accessories and hardwares.
Supply, commissioning o f Modular wall socket 3 pin, 16A 230V A.C. including supply of 2 Module surface recessed mounted G.I. box with combined plate of requisite size and fixing accessories with hardwares.(for AC).
Supply, commissioning of Modular 25A Starter Switch including supply of 2 Module Plastic box with combind plate of requisite size and fixing accessories with hardwares including cutting of wall with supply of all materials for cement plaster finishing of damaged wall to its original decor for AC Machine.
Supply of 60 Watt LED Flood light fitting with Numbers integrated driver.
Installaltion,connection and commissioning of Numbers LED Flood light using 1metre long GI pipe of suitable dia compatible with Flood light fitting including GI clamps, GI strips, bolts,nut with neccessary hardwares and painting with anti- corrosive red oxide primer and painted with aluminum paint along with 2 runs of 1 core 1.5 Sq. mm. PVC sheathed stranded Copper conductor cable 650/1100 Volt grade connecting cable.
Supply, Installation, Testing & Commissioning Numbers of indoor-type Feeder Pillar Panel, fabricated from 16 SWG SS-304 stainless steel sheet, of size 1500 mm (W) x 1250 mm (H) x 450 mm (D), suitable for indoor installation with IP42 protection rating. The panel shall be floor- mounted, dust and vermin proof, and complete in all respects with the following: (i) Copper TPN busbar rated for 320 A, insulated and adequately supported. (ii) 1 No. 250 A TPN Changeover Switch, front-handle operated, 415V, 50Hz, 50kA. (iii) 1 No. 250 A, 4P, 415V, 50kA MCCB (Incomer), microprocessor-based with adjustable overload & short-circuit protection. (iv) 6 Nos. 100 A, 4P, 415V, 50kA MCCBs (Outgoing Feeders), microprocessor-based with adjustable protection. (v) Required control wiring, internal connections, cable terminations, earthing links, nameplates, labeling, and shrouding. The panel shall be installed on a masonry platform or floor grouting frame, including necessary anchoring hardware and alignment. ELOCO-SHOP-CLW-ELECTRICAL/CLW
Supply, commissioning of 3Ø/1Ø, 4-way MCB operated distribution board comprising of 01 No. 63A 4 pole, 30KA MCCB as incomer and 06 Nos. 20A SP MCB and 06 Nos. 10A SP MCB as outgoing feeders enclosed in a powder coated / Synthetic stove enamelled grey paint sheet steel enclosure. The D.B. shall be recessed into the wall including the supply of fixing accessories and hardwares.
(i) Installation,Testing and commissionig of 10- meter high polygonal hot-dip galvanised poles with top-mounted cross arms, complete with all accessories including base plate, foundation bolts, and junction box. The mast has been designed considering base wind speed as per IS 875. (ii) Design, Supply and Construction of shallow foundation with M-25 concrete for 10m Stadium mast considering safe soil bearing capacity. Note:- If the Safe Bearing Capacity (SBC) is adequate and pile foundation is not required, the rate as per DSR will be applicable.
Supply, commissioning of BLDC ceiling fan. BLDC ceiling fan technical parameters are the following: 1. Working Voltage: 230 Volts AC, Single Phase, 50Hz 2. Sweep: 1400mm 3. Number of blades: 3 4. Blade Material: Aluminium 5. Type of bearing: Double ball bearing 6. Insulation Class: Class E 7. BEE star rating: 5 8. Speed control method:- With Remote and power switch toggle 9. Nominal Power consumption: 35 Watts 10. Warranty:- 60 Months 11. Conforming to IS: IS 374 12. Make/brand: Havells, Crompton, Atomberg, Orient. The scope of work includes installing the BLDC fan at the purchaser's premises, as per the directions provided. The contractor shall supply all necessary accessories for the complete installation.
supply, commissioning of 250W Industrial Fan wall mounted , Sweep Size:600 mm, Single Phase, 230V AC,1440 RPM, 3 BLADE. ELOCO-SHOP-CLW-ELECTRICAL/CLW Total 1782959.60 Item- 03 Item wise breakup of schedule-III(Power Augmentation) S No. Item Description of Item Unit Qty Rate Amount No
Design, supply, erection, testing, and Set commissioning of a 500kVA, 11kV/415V, 3- phase, copper-wound, oil-immersed outdoor compact substation (CSS), conforming to IS:1180 (Level-3), suitable for 52°C ambient. The CSS shall include a transformer equipped with an off-circuit tap changer (+5% to -10% in steps of 2.5%), HT panel with 11kV VCB (630A, 25kA) including protection relays (OCR, EFR, UVR), CTs, PTs, and metering, and LT panel with 4-pole 1000A, 50kA ACB as incomer and 6 Nos. of 400A MCCBs as outgoing feeders. All components shall be housed in a weatherproof, vermin-proof, powder-coated enclosure with IP54 p r o t e c t i o n . The scope also includes construction of RCC foundation (plinth) of minimum 450mm height above ground level using M20 grade concrete with PCC bedding, proper compaction, and anchoring provisions as per OEM specifications. All internal wiring, interconnections, and accessories shall be provided. Final testing, commissioning, and handing over of the CSS along with test reports, drawings, and O&M manuals is included.
Supply of 3C x 50 sq.mm XLPE, Armoured Metre Aluminium Cable, 11kV grade
Laying only 11 KV grade 3C x 50 Sq mm XLPE Metre UG Cable through trench/GI pipe etc.
Digging and excavation of soil (size 300mm Metre width and 750 mm depth) and formation of kachcha cable trench after dressing, including supply and laying of bricks, brick walling, brick covering, and sand filling at the bottom to cover the cable.
Digging of earth and formation of pucca cable Metre trench of size: 1.0 M deep x 0.6 M wide for laying of H.T cable including supply of good quality bricks, cement, sand, and stone chips. A 150 mm thick R.C.C. slab should cover the trench. The cover shall be cast with steel frame (Top & Bottom) of size 75mm x 75mm x 6 mm thick angle.
Supply of LT XLPE insulated, armoured cable Metre with stranded aluminium conductor of size 4 core x 150 sq.mm, 1.1kV grade, conforming to IS: 7098 (Part I), suitable for underground or surface laying, with adequate mechanical protection and electrical performance as per standards.
Laying of 4 core x 150 sq.mm XLPE, Metre Armoured Aluminium Cable, 1.1 kV grade through Trench/Pipe/Cable Tray as per site requirement.
Boring /cutting of footpath and concrete floor Metre as per required size for laying of G.I pipe and covered the portion with cement plaster/ mixture of stone chips with pitch to make its original decor after laying of G.I pipe as per required size. ELOCO-SHOP-CLW-ELECTRICAL/CLW
Supply and erection of G.I. pipe 150 mm. dia. Metre (Medium gauge) as per IS: 1239 (part-I)-1990 including supply of G.I. fixing clamps and hardware. G.I. fixing clamps shall be made up of 25 x 6mm. thick G.I. flat with G.lnuts, bolts, and washers, etc., and clamps shall be made as per site condition to be used in road crossing & taking cable from pole to ground.
Supply of Heat Shrinkable Straight through Numbers cable jointing kits complete with all accessories suitable for 3C x 50 Sq mm 11 kV(E) grade, XLPE insulated PVC sheathed steel strip armoured Al conductor cable.
Fixing of Heat Shrinkable Straight through Numbers cable jointing kits complete with all accessories suitable for 3C x 50 Sq mm 11 kV(E) grade, XLPE insulated PVC sheathed steel strip armoured Al conductor cable.
Supply of Heat shrinkable outdoor end Numbers termination kit suitable for 11kV(E) grade 3C x 50 Sq mm XLPE armoured Al. conductor cable complete with all accessories and supply of all materials with proper phase marking.
Fixing of Heat shrinkable outdoor end Numbers termination kit suitable for 11kV(E) grade 3C x 50 Sq mm XLPE armoured Al. conductor cable complete with all accessories and supply of all materials with proper phase marking.
Earthing: Supply, installation, and connection Numbers of proper, maintenance-free, long-life zinc- coated earthing. The job shall also include supply, laying, and connection of G.I.flat 25 x 6 mm. thick from earthing pit to Distributionpanel & G.I. Earth terminal bar on the Panel and G.I.earth wire 8 SWG to be laid from earth terminal bar toDistribution Panel. The job shall also include the supply and erection of G.I. earth terminalbar & G.I. earth wire. (Used for earthing of Transformer body, Neutral & Panel.)
Supply, installation, testing & commissioning Metre of (225 mm width x 50 mm depth x 1.6 mm thickness) perforated Hot Dipped Galvanized Iron Cable Tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections fixed with MS Angle frame duly painted of 35 mm x 5 mm thick and all hardware complete in all respect for Laying of XLPE, Armoured Aluminium Cable .
Material & labour for cable Route indicator Numbers made out of RCC, marked LT/HTcable fixed on MS angle of size 25x3mm, 300 mm long embedded in PCCblock of size 300x300x400 mm with cement concrete 1:3:6 ratio all as specified and directed.
Supply and fixing of HT Danger Board of size Numbers 400x 300 x 3 mm thick painted with skull & bone and marked "DANGER"11 KV HT/LT to be provided in Tri Language Bangla, Hindi & English, secured with proper MS clamps, nuts, bolts washers etc all as directed. Total 4242530.09
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2023_12_21IndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_6ACS-61.pdf
ATTACHMENT
Ledspecsrevision1.0_251127_162109_1.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_4ACS-4.pdf
ATTACHMENT
GCCFOR2022.pdf
ATTACHMENT
2022_12_13RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril2022ACSNo_2.pdf
ATTACHMENT
2023_10_20RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_5ACS-53.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_3ACS-311.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14_07_2022.pdf
ATTACHMENT
ACS7GCC2022.pdf
ATTACHMENT
ACS8GCC2022.pdf
ATTACHMENT
GCCUpdateduptoACS-7RAILWAYSBOARD.pdf
ATTACHMENT
SpecialConditionforBidCapacity.pdf
ATTACHMENT
LetterregardingAnnexureV.pdf
ATTACHMENT
ACS10GCC2022.pdf
ATTACHMENT
ACS9GCC2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .