| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹15.0 L+₹1.6 L (11.5%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST BID | |
| 3 | L3₹16.5 L+₹3.0 L (22.2%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST BID | |
| 4 | L4₹16.5 L+₹3.0 L (22.3%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST BID | |
| 5 | L5₹17.8 L+₹4.3 L (31.9%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST BID |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
20 Nov 2019, 6:00 pmClosed
GE Dronachal
GE Dronachal, Dronachal Top, Neori Hills, Bhopal
PROVN OF PARKING SHED, SENTRY POST AND UG SUMP FOR NAVY LAND UNDER GE DRONCHAL BHOPAL
2019_MES_293751_1
8493/E8
Open Tender
Civil Works
Item Rate
180 days
GE Dronachal
Please refer tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Dronachal
₹36,000
Yes
16 Jan 2020
30 Oct 2019
23 Nov 2019
30 Oct 2019
20 Nov 2019
13 Nov 2019
Amount
M&L for Excavating in post holes (or similar holes) each n exc 0.5 cu. m, hard/dense soil getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. soft / disintergrated rock
Removing excavated material exc.250m but not exc 500 m & depositing where directed at a level not exc. 1.5m above the starting point
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base and foundation etc complete all as specified and directed
M&L for PCC 1:2:4 type B2 (using 20mm graded stone aggregate) as in mass filling / leveling course etc complete all as specified and directed
M&L Reinforcement 10mm dia and over TMT bars cut to length, bent to shape required and binding with MS wire not less than 0.9mm dia complete all as specified and directed.
Ditto as item No 6 but 8mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed
M&L 8mm TMT bars cut to elnth bent to shape required including cranking bindding with MS wire (annealed ) not less than 0.9mm dia.
S&F in Steel work in tubular trusses including special shaped washer, required nuts and bolts fixtures etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (plain or curved) of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws, rivetting, welding etc all as specified.
S&F Plates (plain or chequered)channels, square cut or notched(ordinary and counter sunk) forming holes, with bolting, rivetting attachment Fe 410-W(Gde-E- 250)quality-A complete all as specified.
S&F for Mild steel screw bolts (machine made) 5 to 10 mm dia of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10 cm long complete all as specified.
M&L 100mm thick PCC(1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as directed.
M/L brick wk with sub class B brick straight or curved on plan exe 6 m mean radious built in C/M 1:6.
M&L, for rendering 15mm thick on fair faces of brick work or on concrete surfaces in CM (1:4) external surface finished even and smooth without using extra cement all as specified.
M&L for laying of Sand in base for cushion of PCC inter locking blocks complete all as specified and directed:
M&L for factory made Machine pressed precast 60mm thick coloured chemically treated PCC inter locking blocks (ISI Marked ) M-35 grade as desgin & pattern approved by GE as in Veh parking and filling of joints with Narmada fine sand complete all speciified and directed
M&L PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping including weathering slightly rounded of chamfered angles & thoating with and incl necessary form work etc complete all as specified & directed.
M&L for approved earth filling in floor or pavings, laid in layers n exc 15 cm thick spread , levelled and rammed including watering complete all as specified and directed:
M&L for preparation of new plaster surfaces and applying two coat of cement base paint over one coat of cement base primer complete all speciified and directed
M&L, two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel/iron surfaces exceeding 10cm width or girth.complete all speciified and directed
Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out soft disintegrated rock complete all as specified and directed
M&L RCC (1:2:4) type B1(nominal mix) using 20 mm graded stone aggregate as in foundations, including rafts, footing foundation beams, plinth beam, base for coulm, etc basement slab under ream piles and mass concrete complete all as specified and directed.
M&L RCC (1:2:4) type B1 (nominal mix) using 20 mm graded stone aggregate as in Col, Pillars post and struts etc complete all as specified and directed
M&L RCC (1:2:4) type B1 (nominal mix) using 20 mm graded stone aggregate as in beams, cantilever, bressummers, lintel over 1.5m span etc complete all as specified and directed
M&L RCC (1:2:4) type B1 (nominal mix) using 20 mm graded stone aggregate as on Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs andd in shelves and the like complete all as specified and directed
Use and waste of formwork to sides of concrete foundation ,footing,base of column ,raft beams , sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter to rough finish surface of concrete flat complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs ,floor slabs ,landing and similar work not exc 200mm thick (Horizontal or sloping) to rough finish surface of concrete flat. complete all as specified and directed
Use and waste of formwork to soffits of floor or roof beams, beam haunching ,grider, bressumber, lintels,cantilever ,sleves including supports ,over hang etc also splay between floor and beams to rough finish surface of concrete flat. complete all as specified and directed
Use and waste of formwork to sides of pillars, posts ,struts piers ,columns and stanchion to rough finish surface of concrete square ,rectangular or polygonal. complete all as specified and directed
Use and waste of formwork to edges of concrete flats ,treads, break in floors window cills, concrete railing , opening in concrete wall, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide to rough finish surface of concrete flat. complete all as specified and directed
M&L for rendering 15mm thick cement plaster on other than fair face of brickwork surfaces of wall in (internal) CM 1:6 surfaces finish fair and even with using extra cement complete all as specified and directed
M&L for rendering 5mm thick on fair faces of brick work or on concrete surfaces of ceiling in CM 1:4 surfaces finish fair and even with using extra cement complete all as specified and directed
supply only Integral waterproofing compound
M&L for Preparing of new plaster surface and applying three coat of white wash on newly plaster surface of ceiling. complete all as specified and directed
M&L, preparation of newly prepaired surface of wall and applying two coat of exterior weather proof water base emulsion paint over a coat of primer of same make on walls all as specified and directed.
M&L, preparation of newly surface of wall and applying two coat of oil bound distemper over a coat of primer of same make on walls all as specified and directed.
M&L for providing 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in sub base of flooring complete all as directed.
M&L cement concrete type B0 (1:2:4) using 12.5 mm graded aggregate 25 mm thick as in floor for receiving screed bed complete all as specified and directed
M&L Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes like tiles etc complete all as specified and directed
M&L 3mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.50 sqm each pane. complete all as specified and directed
S&F 150 mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F 150mm Aluminium handles , cast type anodised complete all as specified and directed
S&F butt hinges, extruded alluminium,with mild steel hinge pin,bright polished and fixed, type 100mm size C21 complete all as specified and directed
M&L for approved earth filling in floor or pavings, laid in layers n exc 15 cm thick spread , levelled and rammed including watering complete all as specified and directed:
M&L of anti- termite treatment for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area
M&L of anti- termite treatment for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
M&L of anti- termite treatment for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
M&L of anti- termite treatment for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
M&L of anti- termite treatment for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall
M&L for 20-25 mm thick machine cut mirror polished kota stone slab flooring with Kota stone not less then 550X550mm size, laid over cement screed of 15mm thick in CM 1:4 laid & jointed with gray cement slorry mixed with pigment to match the shade of the slab including
All as per item No 51 but in skirting size not less than 550mmx 100mm x 11-12 mm thick all as specified and directed.
S&F in door or window frame of any description with aluminum sections, coloured powder coating not less than 50micron, and fixing in positions including all necessary cleats, lugs, beading, and jointing arrangements, complete all specified & directed.
S & F in Anodised aluminium door shutters aluminium section coloured powder coating not less than 50micron,weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
Excavation in over areas exc 1.5 Mtr but n exc 3.0 mtr and getting out in hard/dense soil (including cutting of roads) for shafts, wells, man holes and for sewage lines and foundation etc n exc 10 Sqm on plan all as specified.
Use and waste of formwork to sides of pillars, posts ,struts piers ,columns and stanchion to rough finish surface of concrete square ,rectangular or polygonal.
Cast iron work grade FG150, unmachined, inbrackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stopvalve boxes, gate stops, parts of ranges, balustersand similar articles exc 5kg each cocmplete all as specified and directed
S&F CI soil spun pipes, waste and vent spun pipes in any length with or without ears ,cement joints laid in fixed to walls including clamps of 100mm dia complete all as speciified and directed
S&F CI vent cowls of 100mm size complete all as specified and directed
M&L for point wiring with and incl 1.5 sqmm (nominal area) PVC insulated multi-stranded copper conductor FRLS in and incl PVC casing and capping ISI marked 20/30 mm size or as required at site incl with its fittings and fixture such as tees, bends, elbows and juction boxes all moduler type surface mounting etc with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing and common earth terminal complete all as specified and directed.
(One light point controlled by one switch.
One fan point controlled by one switch.
One 3 pin socket outlet 5 Amps on independent board.
One 3 pin socket outlet on same board.
M&L for wiring complete 2.5 Sq.mm single core multi standard copper conductor FRLS PVC insulated 1100 Volts drawn through non metalic rigid PVC casing capping including necessary accessories like bends lees and elbows etc fixed on wall/ceiling including sunken type pressed steel terminal boxes of suitable size with plastic laminated white/coloured top sheet cover 2 mm thick including 1.5 Sq.mm FRLS PVC insulated copper green wire for earth wire complete all as specified and directed.
Supply & Fixing only DB SPN 240 Volts 200 Amps rates bus bar having 4 way double door shutters.
S&F MCB SPN 240 Volts of capacity 40 Amps complete all as directed by Engineer-in-Charge.
S&F MCB SP 240 Volts of capacity 5 to 30 Amps complete all as directed by Engineer-in-Charge.
S&F sub main wiring 4 Sqmm with two runs of 4 sqmm single core multi stranded copper conductor and one ron of 2.5 sqmm in PVC conduint including all fitting fixed on wall/ceiling including 1.5 Sqmm PVC insulated copper earth wire connected to earth, complete all as directed by Engineer-in-Charge.
Supply & fix LED tube light along with fixture, 22 W
S&F switch Piano type, 5 Amps 250 Volts single pole one way.
Supply and fixing socket outlet 5 pin flush 6 Amps multi pin 2/3 pin.
S&F ceiling rose surface bakelite 65x60 mm, 3 terminal complete all as directed.
S&F switch Socket flush type 250 Volts 5 Amps multipurpose complete all as directed.
S&F Switch socket outlet type 250 Volts 5/15 Amps multipurpose.
M & L for ceiling fan with step type regulator and all accessories including fixing arrangements of 1200 mm sweep including fixing the same and connectioning and testing complete all as directed
Supply and fix LED street light 70/75 W IP 65 with 40 mm dia light grade bracket length of 1.2 meter
M&L for XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 4 core.
Supply and laying sand cushioning for the purpose intrenches and laying of cables in duct/trench including and consiolidation all as specified and directed.
Brick Sub Class 'B' locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx 6.3mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground level with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanized iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No.5 of SSR part I and earth wire protected by galvanized pipe light grade 25 mm bore and thorugh test point including necessary earth work and excavation in any type of strata, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chember with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm kdia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and directed and testing on completion.
Supply, installation, testing and commissioning of submersible pump electrical driven 415 Volt TP monoblock type including suitable Star delta starter all as directed of capacity 152 LPM discharge at 30 mtr Head of 2 HP including necessary foundation and GI Heavy duty pipe line not more than 10 mtr long for connection work to main line foot valve with strainer , slim seal butterfly valve to suite dilivery pipe of pump, nonreturn valve, complete.
Supply and Fix DOL Starter for 02 HP
Supply , fixing & laying GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittings for laid in trenches all as specified and directed of following size.
GI pipe 25mm dia bore
GI pipe 40mm dia bore
Supply and fixing gun metal gate valves with iron wheel head screwed both ends for galvanised iron pipe of following sizes, including taking out old unserviceable gate valves
25mm dia
40mm dia
M&L for PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 3.5 core.
Supply and fixing of rotational moulded PVC water storage tank of capacity 1000 Ltrs cylindrical vertical with closed top including taking down of old broken/tank and making connection for new tank all as specified and directed by Engr-in-charge.
Supply and fix Reverse Osmosis Plant wall mounted purification production rate 40ltr /hrs max duty cycle 200L/day filter cartidge sediment,activated caarbon memnrane type thin film composite RO (2) UF membrane 0.1-0.01 micron auto flushing system inlet water pressor /temp (Min)0.3Kg /CM 2 or 4.3psi /10sentigrade inlet water pressor /temp (max) 3 Kg /CM or 42.7 psi /40degree sentigrade of 104 faregn hight over all dimention of RO 415mmx222mmx410 net weight 14.2 kg power consumption 60 watt input power supply single phase 250 volts Ac 50Hz al as per directed by Engr-in- charge.
Jyoti enterprises
Samaksh Enterprises
MODI CORPORATION
M/S RAKESH TRADERS
Vee kay construction
Raja enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .