| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC SHOP NO 18 1ST FLOOR NORTH LAND BUILDING SECTOR NO 1 BACK SIDE OF BANK OF MAHARASHTRA INDRAYANI NAGAR BHOSARI PUNE 411039 | PUNE | MAHARASHTRA | 411039 | L1 | Accepted-AOC Being rate reasonable | |
| 2 | L2₹45.2 L+₹14.4 L (46.6%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹47.4 L+₹16.5 L (53.7%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
14 Mar 2022, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
CERTAIN PROVN AND SPECIAL REPAIRS WORKS UNDER GE C KIRKEE
2022_MES_509611_1
8575/E8 OF 2021-2022
Open Tender
Civil Works
Item Rate
180 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
GE CENTRAL KIRKEE
₹99,800
23 Mar 2022
22 Feb 2022
15 Mar 2022
22 Feb 2022
14 Mar 2022
1 Mar 2022
22 Feb 2022 - 28 Feb 2022
Amount
Surface excavation in soft/loose soil n.exc 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed.
Surface excavation in hard dense soil n.exc 30 cm deep and averaging 22.5cm deep and getting out complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and as directed.
Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and as directed.
Excavating in post holes (or similar holes) in soft loose soil each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick in soil complete all as directed.
Removing excavated surplus soil not exc 50 m and depositing where directed at level n.exc 1.5 m above the starting point complete all as specified and directed.
M & L Spreading and levelling soils in layer n. exc. 25 cm thick including well ramming watering as required complete all as specified and directed.
M&L Plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling as mass concrete complete all as specified and as directed.
M&L plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregates) as in foundations, filling and mass concrete etc.complete all as specified & directed.
M&L Form work to sides of concrete foundations, footings bases of columns, raft and raft beams, sides and soffits ( if any ) of foundation plinth beam and similar work vertical or bottom rough finished surfaces of concrete in flat and curved surfaces complete all as specificed and as directed.
M&L Form work to sides of pillars, posts, struts, piers, columns rough finished surfaces square, rectangular or polygonal complete all as specificed and as directed.
M&L Form work to sides and soffits of floor or roof beams, beams haunching, girders, bressumers, lintels, cantilevers shelves including supports overhangs etc, also splays between floors and beams etc flat rough finished surface complete all as specificed and as directed.
M&L Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) with rough finished flat concrete surfaces complete all as specified
M&L Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide with rough finished flat concrete surfaces complete all as specified and as directed.
M&L RCC M-25 design mix (using 20 mm graded stone aggregate.) in footings & plinth beams etc. complete all as specified and directed.
M&L RCC M-25 design mix (using 20 mm graded stone aggregate.) in columns etc. complete all as specified and directed.
M&L RCC M-25 design mix (using 20 mm graded stone aggregate.) in roof beams & lintel beam etc. complete all as specified and directed.
M&L RCC M-25 design mix (using 20 mm graded stone aggregate.) in roof slabs supported on walls etc. complete all as specified and directed.
M&L RCC M-25 design mix (using 20 mm graded stone aggregate.) in Chajjas etc. complete all as specified and directed.
M&L mild steel TMT bar 10 mm dia and over, cut to length, bent to shape required and binding with MS wire (annealed) not less than 0.9mm dia. complete all as specified and directed.
M & L TMT mild steel bars 6 to 8mm dia, cut to length, bent to shape required inluding cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed.
M&L mild steel TMT bar 5mm dia and over upto and including 10mm dia cut to length, bent to shape required and binding with MS wire (annealed) not less than 0.9mm dia. in stirrups, spacers and binders complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for Hardcore of broken stone or boulders gauge n exc 63mm, deposited spread levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for Hardcore of gauge exc 63mm bt n exc 100mm broken stone or boulders deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to true surface complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and as directed.
M&L Cement concrete 75mm thick (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specificed and as directed.
M&L 40mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) finishing the surface even and smooth with using extra cement complete all as specified and as directed.
M&L 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in sub base of floors/levelling course finished even and fair complete all as specified and as directed.
M & L cement concrete prepolished chequered tiles 300x300x25 mm thick with grey cement and pigment, set and jointed in neat cement slurry and pointed in colured cement to match the pigments, over and including 20mm thick screed bed or bedding layer in CM 1:6 etc. complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for precast cement concrete block masonry of grade C-5 having density not less than 1800 kg/cum and 28 days average minimum compressive strngth of block should be 5 N/sqmm as in walling set in cement mortar 1:6 complete all as specified and as directed.
M&L for Brickwork with sub-class old size `B' bricks, straight or curved on plan to any radius as in half brick thick walls, built in CM 1:4 complete all as specified and as directed.
M&L for Brickwork with sub class old size ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed.
Taking down cement plaster on brick or stone walls or concrete surfaces etc at any position including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for 5mm thick rendering on concrete surfaces of ceiling in CM (1:3) and rendering is to be finished even and smooth without using extra cement complete all as specificed and as directed.
M&L rendering 10 mm thick on concrete surfaces of wall in CM 1:6, finished even and smooth without using extra cement complete all as specificed and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 (external) with using WPC and finishing top surfaces even and smooth without using extra cement complete all as specified and as directed.(WPC shall be measured and paid seperately)
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 (internal) and finishing top surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L rendering 12mm thick in cement mortar (1:4) on brick walls or concrete surfaces complete all as specified and as directed.
Supply only approved integral waterproofing compound.
S&F for powder coated anodised aluminium ventilator shutters, fixed type without sash bar including stainless steel wire cloth of 0.63 mm nominal dia and average aperture 1.4 mm, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc.and fixed to block/stone masonry wall complete all as specificed and as directed.
S & F framed work such as grills, grating etc with ends bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors and similar work confirming to Fe 290 Gde E-165 complete all as specified and as directed.
M & L Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.
S & F 2nd class hardwood 35 mm thick Plain, framed, panelled shutters (two number of panels), with panels with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated supplied and fitted to chowkats complete all as specified and as directed.
S & F 35mm thick 2nd class HW glazed or skelton shutter open rebated divided into square with plain chamfered or rounded mitred and rebated without sash bar and prepared to receive gauze or glaze, size of members as per clause No. 8.20 (a) of SSR pt-1 complete all as specified and as directed by Engineer-in-Charge.
S & F Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and as directed by Engineer-in-Charge.
S & F 5.5 Sheet glass exc 0.5 sqm in each plane, ordinary quality and glazing with oil putty in square complete all as specfied and as direcetd.
S&F in repairs SS Curtain rod 20mm dia fancy type complete all as specified and directed.
S&F in repair decorative Knob stainless steel curtain rod brackets suitable for fixing of 20mm dia curtain roads including necessary fittings such as rawl plug and screws complete all as specified.
M&L for preparing new Steel Surfaces of any description, over 10cm in width or girth, not otherwise described and applying evenly two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces including all necessary preparation over 10 cms width or girth complete all as specified and as directed.
M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2010) complete all as specified and as directed.
S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified. (Make: Rajashri or equivalent as approved.)
S&F Factory made soild PVC profiled panel door shutter 28mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill, with 'C type Gl or 40 x 20 x19 of MS pipe as stiffner & supplying & fixing in frame at site as per specifications & drawing. complete all as specified. (Make: Rajashri or equivalent as approved.)
S&F 100 mm butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.
S&F for aluminium handles size 150 mm cast type anodised complete all as specified and as directed.
S&F aluminium anodised barrel tower bolt 200mm long of extruded section with steel screws complete all as specified and as directed.
S&F 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
S & F mild steel spring for doors 300mm long, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed by Engineer-in-Charge.
S&F wash down water closet (pedestal pattern) complete (including fixing of seat cover) pedestal pan and trap including connection to drain (or outgoing pipe ) and flushing pipe, antisyphonage pipe etc complete all as specificed and as directed.
S&F in repair CP health faucet for EWC with and including two way CP bib tap 15mm dia all as specified and as directed by Engineer-in-Charge.
S&F in repair Vitreous china white squatting pan orrissa pattern of size 580mm x 440 mm with integral foot rests including necessary lime concrete and 100 mm bore cast iron ‘P’ or 'S' trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, squating pan including connection to trap and to flushing pipe, antisyphonage pipe complete all as specified and as directed.
S&F bib taps, long body with flange, cast copper alloy, chromium plated, fancy type screwed for 15mm bore of iron pipe or for brass ferrule complete all as specified and as directed.(Make : Prayag cat No. 8308 or technocommercialy equivalent in Jaquar or cera)(Note:Rate quoted shall be deemed to be included taking down bib tap if any, if ordered by the Engineer-in-charge)
S&F pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe, complete all as specified and as directed.
S&F in repair pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe, complete all as specified and as directed.
S & F stop valves cast copper alloy, screwed down, high pressure with butterfly handle, screwed both ends for iron pipe or for unions 15mm bore complete all as specified and as directed.
S & F in repair angular stop valves cast copper alloy, screwed down, high pressure with butterfly handle, screwed both ends for iron pipe or for unions 15mm bore complete all as specified and as directed.
S&F PVC low level flushing cistern (white) of 10 liters capacity with inlet ball float valve, PVC flush pipe and necessary fixing arrangements and connecting to water pipe and WC etc complete all as specified and as directed.(Note:Rate quoted shall be deemed to be included taking down flushing cistern if any, if ordered by the Engineer-in-charge)
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S&F wash hand basin, flat back 550x400mm vitreous china (white) including PTMT waste fittings, 32mm bore size, angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing complete all as specified and as directed.
S&F in repair wash hand basin, flat back 450x300mm vitreous china (white) including PTMT waste fittings and PVC flexible waste pipe, 32mm bore size, angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing complete all as specified and as directed.
S&F PVC (SWR) pipes, 75 mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified and directed.
S&F 75 mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specificed and as directed.(Note:Rate quoted shall be deemed to be included taking down floor trap if any, if ordered by the Engineer-in-charge)
S&F in repair PVC (SWR) bends of any radius 110 mm bore/dia complete all as specified and as directed.
S&F PVC (SWR) bends of any radius 75 mm bore/dia complete all as specified and as directed.
S&F 110mm bore/dia PVC vent cowl all as specified and directed.
S&F in repairs cast Iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B - 1 (1:2:4) of 75 mm dia outlet including water leak proof treatment complete all as specified.
S&F Galvanised iron steel water tubing, 15mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F Galvanised iron steel water tubing, 20mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F Galvanised iron steel water tubing, 25mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F Galvanised iron steel water tubing, 50mm bore, medium grade with all fittings and laying in trenches complete all as specified and as directed.
S&F Galvanised iron steel water tubing, 25mm bore, medium grade with all fittings and laying in trenches complete all as specified and as directed.
S&F Galvanised iron steel water tubing, 50mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F gun metal gate valve with iron wheel head, screwed both ends for iron pipes 20 mm bore complete all as specified and directed.
S&F gun metal gate valve with iron wheel head, screwed both ends for iron pipes 25 mm bore complete all as specified and directed.(Note:Rate quoted shall be deemed to be included taking down gate valve if any, if ordered by the Engineer-in-charge)
S&F in gun metal gate valve with iron wheel head, screwed both ends for iron pipes 50 mm bore complete all as specified and directed.
M&L for cutting and welding of existing CI/GI pipe in trenches for fixing/inserting of valve, bends , double socket, Tee pieces, single branch, Y junction etc, of 80mm bore dia of pipe complete by using nesessary cutting material such as gas cutter etc. all as directed by Engineer-in-Charge.
M & L GI tubing 40 mm dia light grade galvanized with all fittings and fixed to wall/pole or under road crossing with necessary clamps, nuts, bolts and washers for cable protection complete all as specified and directed.
S & F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for bore of pipe 75mm etc complete all as specified and directed.
S&F 500 litres capacity rotational moulded, polythene water storage tanks triple layered (cylindrical vertical with closed top) hoisting and fixed in position on roofs including fittings, complete all as specified and as directed.
S&F 500 litres capacity rotational moulded, polythene water storage tanks triple layered (cylindrical vertical with closed top) hoisting and fixed in position on roofs including 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out existing unserviceable overhead tank of any description and in any position complete all as directed.
S&F 1000 litres capacity rotational moulded, polythene water storage tanks triple layer (cylindrical vertical with closed top) hoisting and fixed in position on roofs with and including 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
S & F Rotational moulded polyethylene water storage tanks 2000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out existing unserviceable overhead tank of any description and in any position complete all as directed.
S&F 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as directed.
Removing of old water proofing treatment and cleaning the surface of slab and clearing with wire brushes, removing dust, foreign materials, rubbish off the site to a distance n exc 100 m, removing the strips of lighting conductor including refixing the same after repair work complete all as specified and as directed.
M & L preparing new plastered surfaces of wall and applying two coats of dry distemper over a coat of alkali resistant primer complete all as specified and as directed.
M & L preparation of newly plastered surface of wall and applying two coats of water proof cement base paint over a coat of alkali resistant primer complete all as specified and directed. (Note : Curing of the Cement base paint shall be done as per the manufacturers instruction)
M&L for applying three coats of white wash on ceiling including preparation of newly plastered surfaces complete all as specificed and as directed.
M & L preparing old decorated plastered ceiling surfaces by using wire brush and applying three coats of white wash on ceiling complete all as specificed and as directed.
M & L preparing new plastered wall surfaces and applying two coats of water proof antifungal exterior acrylic emulsion paint (Apex Ultima protek) over a coat of alkali resistant primer complete all as per manufacturers instructions and as directed by Engineer-in-Charge.(Note : Application of Acrylic emulsion paint strictly done by authorised applicator only)
M & L preparing old decorated plastered wall surfaces by using wire brush and jet spray and filling the cracks if any on the surface of wall by the crack sealent of approved make and applying two coats of water proof antifungal exterior acrylic emulsion paint (Apex Ultima protek) over coats of base/primer coat complete all as per manufacturers instructions and as directed by Engineer-in-Charge.(Note : (i) Rate of the crack sealent shall be deemed to included in the quoted rate of this item. (ii) Application of Acrylic emulsion paint strictly done by authorised applicator only.)
M & L preparing new plastered wall surfaces by applying 3mm thick wall care putty to get smooth and even surfaces as directed and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L preparing old plastered wall surfaces and applying two coats of oil bound distemper over 3mm thick wall care putty to get smooth and even surfaces complete all as specified and as directed.
M&L 75mm thick Plain Cement concrete (1:3:6) Type C-2 (using 40mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement complete all as as specified and as directed by Engr-in-Charge.
M&L Forming 12 mm thick expansion joint with pre-formed filler and top 30 mm primed and sealed with sealing compound Grade ‘A’ all as specified for thickness of concrete slab 75mm complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for non skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed.
M&L for Matt finished coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed.
M & L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like over 15mm thick cement Screed base in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M & L for Matt Finished ceramic coloured tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
M&L rendering 10 mm thick on concrete surfaces of wall in CM 1:4, to receive wall tiles or kota stones complete all as specified.
M&L for Glazed ceramic coloured tiles in vertical surface 450 X300 X7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any cement mortar complete all as specified and as directed.
M & L for Machine cut kota stone slab flooring 20-25mm thick over and including 15mm thick cement screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engr in Charge.
M&L machine cut kota stone slab 20-25mm thick over and including 10mm thick backing coat of cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing as in skirting, vertical any type of surfaces, riser of steps including moulding where required complete all as specified and as directed.
M&L rubbing and mirror polishing on surfaces of existing kota stone including cleaning and preparing the suface for polishing complete all as specified as directed by Engr-in-Charge.
M & L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded granite stone aggregate) in sub base complete all as specificed and as directed.
M&L for sand/stone dust filling under floor or in foundation or for cushioning of UG cable/ at cable trenches including watering and consolidation complete all as specificed and as directed.
M & L for Coloured Machine pressed glossy finished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and no pigment laid over sand cushion complete all as specificed and as directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 m clear span, cills, steps seismic and other similar bands plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height copings, kneelers, apex stones, bed plates, kerbs, water troughs, benching in manhole half round shape and the like including weathering, slightly rounded or chamfered angles and throating, complete all as directed.
M&L for providing plain cement concrete 1:4:8 type D-2 (Using 40 mm graded stone aggregates) as in concrete bed to drain pipes for 150 mm bore dia including packing under haunching against the side of pipe after laid and tested etc. complete all as specified and as directed.
M&L for Reinforced cement concrete pipes,150 mm bore of pipes Class NP-2, laid and jointed with collars complete all as specified and as directed.
Demolition of RCC manholes covers including RCC slab set in cment mortar complete all as directed.
M&L Precast RCC cover slab 1:2:4, type B1(using 20mm graded stone aggregates) for manholes, landings, chajjas,water troughs,hangers, shelves and similar articles with plain faces set in CM 1:6 complete all as specified and directed.
Demolition of PCC in any position not otherwise specifically provided for, as in surface channel, drains, manholes, copings, ground floors and pavings of any description and in any position and removing debris out side MD land complete all as specified and directed by Engr-in-Charge.
Cutting into existing manholes for conncting new drains 150 mm dia pipe, making good to pipe and rendering , cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement conrete 1:2:4 type B-1 smooth finished , and reforming benching as required complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Taking down chowkats and frame exc 1.5 Sqm but n.exc 4.00 sqm each of any type including shutter without taking off shutter from the frame complete all as specified and as directed.
Taking down chowkats and frame n.exc 1.5 Sqm each of any type including shutters without taking off shutters from the frame complete all as specified and as directed.
S & F Pressed steel door frame for doors of size 105 x 60mm with single rebate including necessary fixing lugs, hinges, lock strike plate, etc complete with and including hollow section of frame to be filled with PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) complete all as specified and as directed by Engineer-in-Charge.
S & F Pressed steel door frame for doors of size 125 x 60mm with single rebate including necessary fixing lugs, hinges, lock strike plate, etc complete with and including hollow section of frame to be filled with PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) complete all as specified and as directed by Engineer-in-Charge.
M&L Rolled mild steel in roof truss (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, rectangular section conforming to Fe 410 -W(Gde-E- 250) quality-A, complete all as specified and as directed.
S&F pre painted galvalume aluminum zink coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa, pitch 190mm, depth 29mm (Galvalume base - PPGL trapezoidal profile sheet) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F framed work such as grills, grating etc with ends bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors and similar work confirming to Fe 290 Gde E-165 complete all as specified and as directed.
M&L Rolled mild steel in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with rivted, bolted or welded attachment conforming to Fe-290(Gde E?165) complete all as specified and as directed.
M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 10 to 20 mm from floor/roof slab/chajjas and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign, complete all as specificed and as per directed by Engineer-in-Charge.
M&L for application of high build polymer modified cement mortar (1:2.5) mixed with 3 kg SBR per bag of cement in ceiling surfaces 10 to 20mm thick in two layers surfaces over a coat of bonding agent Nito Bond SBR (1 Ltr SBR + 1 Ltr) water + 3 kg cement), complete all as specificed and as per directed by Engineer-in-Charge.
Supply and lay LT UG cable 2 core 6 sqmm XLPE insulated armoured 1100 Volts grade heavy duty cable with PVC insulated stranded aluminium conductor laid in trenches incl indoor and outdoor joint all as specified and directed.
Supply, laying and testing cable XLPE insulated screened pvc bedded galvanised steel strip or wire armoured electric power cable (heavy duty )1100 volts grade with stranded aluminium conductor of size 3.5 core 35 sq mm all as specified and directed.
Taking down defective service cable of any size, any description.
Supply only HDPE Double wall corrugated pipe (DWC) confirming to IS-14930 (Part-II) of size 50/38mm including snap fit coupler as required for cable protection.
M&L for brick protection with old size sub-class bricks ‘B’ Designation 75 for UG cable.
M & L for concealed point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC conduit of medium grade of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer with MS concealed box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc all as specified and as directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismantling taking down old unserviceable point wiring with all fitting and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size screwed with 04 nos cadmium coated screws & cup washer for mounting of switch, socket incl dismantling taking down old unserviceable point wiring with all fittings and making good to disturbed surfaces all as specified and directed.
M & L for concealed point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC conduit of medium grade of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for same bd controlled by one, one way switch including 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer with MS concealed box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches incl dismantling taking down old unserviceable point wiring with all fittings and making good to disturbed surfaces all as specified and directed.
M & L for concealed point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC conduit of medium grade of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16 amps socket (Power) point independent including 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer with MS concealed box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket including taking down unservicable point wiring with all fittings all as specified and directed.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping of suitable size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly including taking down defective sub main wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
Supply and fix switch 6 amps flush type one way single pole all as specified and as directed
Supply and fix ceiling rose 3 terminal PVC insulated body all as specified and as directed.
S&F socket flush type 6 amps, 5 pin, 230V all as specified and as directed.
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v all as specified and as directed.
S&F lamp Holder insulated body with back plate all as specified and directed.
S&F stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50 Hz supply 100 watts complete all as specified and as directed.
S&F LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) all as specified and as directed. (Make-HPL/Havells/CG/Bajaj/ Philips)
S&F MCB, Single Pole, 6 to 32 amps, 240 volts, 10 kA breaking capacity, "C" curve all as specified and directed. (Make- Cat Part No 4085-87 to 4085-95 of Legrand or equivalent of Schinder/ABB)
S&F MCB, Double Pole, 6 to 32 amps, 415 volts, 10 kA breaking capacity, "C" curve all as specified and directed. (Make- Cat Part No 4086-28 to 4086-36 of Legrand or equivalent of Schinder/ABB)
S&F MCB distribution board, Double door, metal enclosure , SPN, 230 Volts, 4 way all as specified and directed. Make- Cat part No 5076 10 of Legrand or or equivalent of Schinder/ABB
S&F Vertical MCB distribution board, as MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way all as specified and directed.
S&F MCB distribution board, as MCB incomer, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way all as specified and directed.
S&F MCCB,TPN, 100 Amps, 415 Volts all as specified and directed. MAKE- Cat Part No- 4087-92 to 4087-94 of Legrand or equivalent of Schneider/ABB
S&F LED building security light 15 watt 230 volt complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flecible conductor cable , one GI medium grade 20 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS clamp and fastner all as specified and directed. Make-HPL,cat part No HPLLEDSL1560E or equivalent in Bajaj/Philips/CG/Havells
S&F LED batten fitting, 20 watt , CDL, 230 volts, 4 feet long complete with all accdessories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 Nos including taking down if any all as specified and directed. Make-HPL,cat part No HLPT51820PCGCW or equivalent in Bajaj/Philips/CG/Havells
S&F LED batten fitting, 09 watt , CDL, 230 volts, 2 feet long complete with all accdessories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 Nos including taking down if any all as specified and directed. Make-HPL,cat part No HLPT51509PCGCW or equivalent in Bajaj/Philips/CG/Havells
S&F LED building security light 25 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20/25mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener including taking down if any all as specified and directed. Make-CG Cat Part No LSTS-25-CDL or equivalent from approved list of make circulated By E-in-C.
Supply and fixing Exhaust fan 200 mm in sweep (Steel body) 230/240 volt AC complete with all acessories including making connection by using flexible wire of size 0.50 sqmm 3 core and making holes, grouting nut bolts in wall for exhaust fan complete all as directed. Make : Bajaj/Usha/Crompton
M & L Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 04 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI lead 04mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
S.R.M.K Enterprises
Raj Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .