Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹31.3 L+₹1.8 L (6.04%)Rejected-AOC BOOTH NO 119 SECTOR 9 PANCHKULA 134109 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹32.0 L+₹2.5 L (8.54%)Rejected-AOC 217 ARHAT BAZAR KASAULI DISTT SOLAN HP 173204 | SOLAN | HIMACHAL PRADESH | 173204 | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | Rejected-Technical | - | Rejected-Technical DD/Bankers Cheque NOT UPLOADED |
Tender Value
₹34.8 L
EMD Value
₹69,600
Closing Date
22 Oct 2022, 6:00 pmClosed
Rahul Meena, IDSE, EE, Garrison Engineer
MES OFFICE GE KASAULI DISTT SOLAN HP
PROVN OF 250 KVA STANDBY DG SET FOR P-3 WATER SUPPLY INSTALLATION AND SPL REPAIR (E/M WORKS) TO BLDG NO. 29 (OR MD ACCN) OF MH KASAULI UNDER GE KASAULI
2022_MES_552260_1
GEK-56/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KASAULI UNDER GE KASAULI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KASAULI
₹69,600
Yes
11 Nov 2022
15 Sept 2022
29 Oct 2022
15 Sept 2022
22 Oct 2022
10 Oct 2022
Amount
Schedule 'A' Section - I
Supply, installation, commissioning and testing of Diesel Engine driven factory assembled, floor mounted ,silent type diesel generating set of capacity 250 KVA output at NTP with AMF control panel, 3 phase, 4 wire, 50 Hz, 415 Volts 1500 RPM power factor of 0.8, as per IS 10001/10002 complete with safety contact and metering equipment mounted on common base frame on PCC platform with anti-vibration pads as recommended by manufacturer including inbuilt type Manual Control Panel from DG set manufacturer’s with all fixing arrangement complete all as specified, directed and comprising the following:-
PRIME MOVER : Prime mover directly coupled with water cooled engine suitable rated matching BHP but not less than 310 BHP for driving 250 KVA (200 KW) capacity alternator, 1500 RPM , electric-start four stroke diesel engine confirming to ISO -3046/ BS- 5514 and IS 10001/10002 for continuous running and capable for taking 10% over load for one hour for every 12 hours with the following accessories:-
Cooling sytem
Heavy duty Radiator Cooled
Engine Mounted water pump
Thermostat
Coolant
Self contained piping
Fuel system
High pressure common rail fuel system/ CRDI fuel injection technology.
Spin on type fuel filter
Self contained piping
Lubrication System
Lube Oil pump
spin on type Lube Oil filter
Self contained piping
Air Intake system
Dry type replaceable paper element Air Filter
Air Intake Manifold with necessary connections
Turbo charger
Exhaust system
Exhaust Manifold
Flexible piping
Silencer Hospital Grade
Governing System
Power Command (PC) Microprocessor based Controller system
Starting System
DC starter
Battery Charging Alternator
Inbuilt regulator
Other System
Fly wheel with fly wheel housing
Any other items required for functional requirement as per OEM
ALTERNATOR : Alternator 250 KVA at 0.8 Power factor self regulated three phase 4 wire system with neutral, 415 volts, 50 Hz, 1500 RPM conforming to BS 2613 or BS 5000/IS-4722 complete with automatic voltage regulator to give rated output at NTP conditions. (i) The alternator shall be self excited, self regulated, self ventilated in brushless design, provided with suitable automatic voltage regulator and shall conform to BS 2613 or BS 5000. Alternator foot mounted fitted with ball or roller bearing including making cable connections. The alternator shall be suitable for tropical climatic condition of Kasauli. The excitation system consists of an electronic automatic regulator having very fast response to load changes. The silent features of alternator are:- (i) (+) or (-) 1% voltage regulation under static conditions. (ii) Class H insulation. (iii) Permanently lubricating bearing. (iv) 10% over load allowed for one hour for every 12 hour. (v) Copper winding with Star connection (all six leads shall be brought out of stator frame)
Control Panel with AMF Panel :- Control Panel shall be made of CRCA sheet of suitable gauge and powder coated for weather proof and long lasting finish. The control panel shall consist of the following features:- (i) Microprocessor based control panel for generator set monitoring, metering and control system with LCD display designed to meet the demands of engine driven DG sets having Digital AVR, electronic governing with temp compensation, start/stop, Engine Metering Oil pressure, coolant temp, battery voltage, engine speed and AC alternator metering L-L Voltage, L-N voltage, current, Volt-Ampere, frequency. Engine protection:- low lube oil pressure, High/Low coolant temp, over speed, battery over/under/waek volts fail to crank/start, sensor failure.AC alternator Protector:- over/under voltage, over/under frequency, over current, short circuit and loss of AC sensing and also having Data logging history of engine etc with protection against phase sequence, phase missing & earth fault tripping complete. (ii) Aluminium Bus Bar of Suitable rating with incommimg/ outgoing terminals. (iii) Indication Lamps for load ON and set Running. (iv) MCCBs of suitable rating with overload and short circuit protections. (v) Contactor of suitable rating with control wiring including all metering accessories complete.
ACOUSTIC ENCLOSURE : Floor mounted Accoustic enclosure (canopy) suitable for 250 KVA DG set as per CPCB norms of the same make as that of DG set to be provided with following provisions/ specifications:- (i) The accoustic enclosure is made from CRCA sheet of suitable gauge and specially designed to meet stringent CPCB norms of 75dBA @ 1Mtr at 75% load under free field condition. (ii) The sheet metal components are Hot dip not less than seven tank pretreatment process. (iii) It is purepolyster based powder coated(inside as well as outside). All nuts / bolts / hardware are zinc coated. (iv) Baterry is accommodated in a tray inside the enclosure. (v) The doors are fitted with gasket with high quality EPON gasket to avoid leakage of sound. (vi) Sound proofing of enclosure is done with high density fire retardant PU foam conforming to IS 8183. (vii) Hospital Grade silencer shall be provided within enclosure to control exhaust noise. (viii) Adequate ventilation shall be provided to meet requirement for combustion and heat removal. If required a blower shall be used to meet total air requirement and air changes. (ix) Temperature of enclosure does not exceed beyond 50 degree C of ambient temperature. (x) Enclosure shall be provided with 'High enclosure temperature safety device'. (xi) There shall be provision of emergency shut down from outside the enclosure. (xii) There is arrangement of proper illumination inside the canopy. (xiii) Enclosure is provided Air inlet louvers,drains for lube oil/ fuel, fuel filling arrangement etc. (xiv) Two point for lifting for easy handling,
(i) Maintenance free sealed lead acid battery of appropiate AH and volts as per OEM recommendation along with all accessories along with battery lead copper, connector with in built trolley for battery. (ii) Starter motor (iii) Starter gearing (iv) Start/Stop push button (v) Invertor cum battery charger 500 VA capacity suitable to work on 230 volts 50 Hz AC supply system for charging of DG set batteries externally when DG set is in off position (vi) Alternator/Dynamo of suitable capacity to charge the battteries while DG set running complete with cut out all as per manufacturer's recommendation .
Daily services fuel tank in built type suitable for full load running of DG set for min 8 hours enclosed within the canopy all as per CPCB norms with level indicator inlet, outlet, drain plug, air vent and locking arrangement etc including fuel pipe connections etc complete.
Standard safety device and self starter having 12 volts DC
Heavy duty base frame of sturdy design made of MS stud with necessary reinforcement and lifting arrangements.
Sets of AVM pads between the engine alternator feet and the base frame as per OEM.
Exhaust system shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to ISO 3046/ BS-5514 to prevent excess heat radiation on the engine and safety of operator including flexible coupling with guards.
Tools:- Following set of tools shall be provided alongwith DG Set and the cost of the same shall deemed to be included in the unit rate quoted for DG set:- (i) Set of DE spanner – 6 – 32 mm - 1 set (ii) Insulated cutting plier 250mm - 1 No (iii) Ring spanner 300mm - 1 No (iv) Screw driver set - 1 No (v) Ring spanner set (Ratchet type) – 6mm to 32mm - 1 Set of 10. (vii) Allen key set - 1 Set (1.5mm to 10mm) (viii) Cell tester - 1 No (ix) Hydrometer - 1 No (x) Tool box-01 No (xi) Rotary type fuel pump-01 No
DG set shall be inspected in factory premises before despatch by representative of the Accepting officer.
Note:- (i) The engine of DG set shall be suitably designed to give output of 250 KVA at NTP including 10% overload. (ii) The quoted rate for DG set is inclusive of PCC foundation. The foundation for DG set shall be made of PCC as per OEM recommedations. The size of platform shall be as per manufacturers recommondations complete all as specified and directed. (iii) The DHPP (fuel) required for testing of DG set shall be arranged by the contractor and the cost of the same shall deemed to be included in the unit rate quoted for DG set. (iv) Phase-I test shall be carried out by Engineer-in-Charge for no load for 1 hour and Phase-II test shall be carried out in presence of IEM/EI for a period not less than 12 hours continuously out of which at least half an hour each on No load and 25% load, two hours on 50% load and four on 75% load, four hours on rated full load and one hour on 10% in excess of rated full load (v) DG Set shall be composite type with Control panel, Prime mover, alternator and allied accesories in one enclosure.
Supply and laying passing through pipe testing and commissioning of 1100 Volts grade 'Heavy duty' PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi standed served with inner sheating of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed of size 300 Sq mm nominal cross sectional area 3.5 core confirming to IS specification, Laid in trenches/fixed on poles, walls or under floors etc complete all as specified and directed incl dismentling taking out unsv all as specified and direcetd.
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed by Engr-in-charge. Note : The units rate includes the cost of excavation & earth work in any type of soil charcoal & salt in altemate layers, 25mm GI Pipe (light grade) for watering 50mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
S&F HDPE (DWC) duct pipe 63 mm outer dia confirming to IS: 14930 (Part-II) of approved colour with all accessories, bends, joints, nuts, bolts, clamps etc fittings for cable protection complete all as specified and directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in hard/dense soil for laying of cable/errection of poles etc complete all as specified and as directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick after laying of cable complete all as specified and directed.
Removing surplus excavated material (Soil) to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.
Taking down carefully to existing copper/Aluminum point wiring (light,fan, socket or power) complete including fittings such as switches, ceiling roses, pendents, regulators sockets, light fitting etc removiing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc.
M&L Point wiring using approved colour coding as per IS with unsheathed multistranded FRLS copper conductor single core 1.5 sqmm (nominal area) PVC conduit (ISI marked) including cutting chiseling and grouting concealed PVC conduit pipe, tee, elbow and bend etc. and making good and match with existing surface with all connecting accessories including Recess Metal Wall Box (GI), PVC insulated and unsheated standard copper conductor single core of size 1.5 sqmm as earth continuity conductor to common earth and connecting to earth dolly (switch and sockets to be measured and paid separately) proper colour coding will be maintained complete all as specified for the following.
One light / Fan point controlled by one way switch 5 Amp.
One 3 pin 5 Amp socket out let controlled by one switch on same board.
One 3 pin 5 Amp socket out let controlled by one switch on independent board.
Call bell point.
One light point controlled by swiches two ways.
-do- all as per item No 10.00 here in before but for one socket out let 3 pin 15 Amp with 4 sqmm PVC copper conductor and 4.0 sq mm PVC insulated copper conductor as earth contiuity conductor.
Taking down old unsv and S & F switch piano flush type (ISI marked), single pole, one way 6/5 Amp, 240 Volts complete all as specified & directed.
Taking down old unsv and S & F switch piano flush type (ISI marked), single pole, 2 way 6/5 Amp, 240 Volts complete all as specified & directed.
Taking down old unsv and S & F switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts complete all as specified & directed.
Taking down old unsv and S & F socket outlet 2 / 3 pin, 6/5 Amp piano flush type complete all as specified & directed.
Taking down old unsv and S & F socket outlet, 2 in 1, 3 pin 6 / 16 (5/15) Amp, piano flush type complete all as specified & directed.
Taking down old unsv and S & F bell push 5/6 Amps SP flush type complete all as specified & directed.
Taking down old unsv and S & F call bell ding dong type AC 230 V complete all as specified & directed.
Taking down old unsv and S & F ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed.
Taking down old unsv and Supply & Fixing sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 8 way, 240 Volt .
Taking out old unsv and S&F MCB single pole having braking capacity 10 KA, 6 to 32 Amps 240 volts B curve complete all as specified & directed.
Taking down old unsv and Supply & Fixing MCB SPN having braking capacity 10 KA 35-60 Amp, 240 Volt , complete all as specified and directed.
S& F 20 W Rechargeable Led Batten with Elegant design offers high Brightness, Energy Saving, Size-4 ft, 20W Inverter Led batten Upto 4 hrs Back up,Powerful lithium battery-5600 mah, Long battery life-500+ Recharge Cycle,Charging Time-8 hrs to 10 hrs including dismantling taking down unsv fitting any type complete all as specified and direcetd .
Taking out old unsv and S&F Wall mounted LED batten extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 10 W 6000K.
Supply and fixing energy saving LED sorrunding light 45 W 6000K 240 W,One GI medium grade 40 mm dia bracket of total length 1 m and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed.
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50 m below notmal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 20 mm bore with funnel wire mesh and medium grade GI wire protection pipe 15 mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete ass as specified and testing on completion complete ass as specified and directed .Note - The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20 mm GI pipe (light grade) for watering 15mm GI protection pipe (medium grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
Taking out old unserviceable and M&L for sub main wiring with two single core PVC unsheathed FRLS copper cable 2X6 Sq mm+ 1x6 Sqmm, 650/1100 volts stranded conductor wire & drawing through rigid non metallic PVC casing -N- caping/ PVC conduit including continuous earth wire PVC insulated unsheathed cable 4 Sq mm copper multi stranded conductor and connecting to common earth and earth dolly complete all as specified and directed by Engineer-in-Charge.
S&F lamp Holder Angular type insulated body with back plate for batten fitting incl dismentling taking down unsv one all as specified and as directed.
S&F LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL.
Taking out old unsv and S&F LED bulkhead fitting 10 W LED complete all as specified and direcetd.
Taking down old unsv and S&F Polycarbonate meter fixing case of size 168X253X115 mm with transparent cover, IP 65 protection class with mounting plate including fixing of existing serviceable KWH meter and connection complete all as specified.
Taking out old unsv and deposit to E/M store S&F Exhaust Fan 250mm Sweep Plastic body, 1500 RPM complete all as specified and directed.
Taking out old unsv and deposit to E/M store S&F Exhaust Fan 300mm Sweep Metal body, 1500 RPM complete all as specified and directed.
Amount of credit of Rs. 4461.10 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
SHARMA ELECTRICAL ENGINEERS
Vinod Kumar Aggarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .