Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.4 LAdmitted-Finance | -9.00% | ₹14.4 L | L1 | Admitted-Finance |
| 2 | L2₹15.8 LAdmitted-Finance | -0.01% | ₹15.8 L | L2 | Admitted-Finance |
| 3 | L3₹19.8 LAdmitted-Finance | +25.00% | ₹19.8 L | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
| 5 | Not Admitted-Fee/PreQual/Technical 26 2 SHAKTI NAGAR PAOTA C ROAD JODHPUR | JODHPUR | JODHPUR | RAJASTHAN | - | - | - | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹15.8 L
EMD Value
₹31,600
Closing Date
6 Mar 2026, 10:00 amClosed
E.O
Municipal Board Sumerpur
civil work
2026_DLB_540904_1
9548-9550 date 19-02-2026
Open Tender
Civil Works
90 days
sumerpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
MD RISL
₹31,600
Yes
13 Mar 2026
23 Feb 2026
6 Mar 2026
23 Feb 2026
6 Mar 2026
23 Feb 2026
Random rubble masonry with hard stone in foundation and plinth :Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
Centring and shuttering with plywood or steel sheet upto two stories ( each story of height upto 3.5 metre from floor level) including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
Reinforced cement concrete work in beams, suspended floors,roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishingand reinforcement:M-20 Grade Concrete (1:1½:3 (1 cement : 1½ coarse sand : 3graded stone aggregate 20 mm nominal size) -As per design mix)
reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars.
Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e. 125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ mortar1:4 (1 cement : 4 fine/ coarse sand)
Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete. as per manufacturer's specification Two or more coats on new work
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - 1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).
Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275gm/m²
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Kota stone slab flooring 25mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :Area of each slab 900 to 2000 sqcm
Wiring of light point /fan point/exhaust fan point/ cell point with 1.5 sqmm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sqmm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS:694) of approved make in surface/recessed ISI marked medium duty PVC conduit & its accessories, round tiles 18 SWG M.S. box with earth terminal screwlees cage connectors for neutral looping in switch board & false ceiling point, 6A switch. 3,0mm thick phenolic laminated sheet zinc plated/brass screws cup washers making connections, testing etc. as required (Group-1) (A)short point upto 3 mtr.
(B) Medium Point upto 6 mtr.
(c) Long point upto 20 mtr.
Wiring of 3 pin 5 amp. light plug point with 1.5 sqmm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sqmm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS:694) of approved make in surface/recessed ISI marked medium duty PVC conduit & its accessories, 18 SWG M.S. box with earth terminal screwlees cage connectors for neutral looping in switch board & false ceiling point, 6A switch. 6A socket, 3,0mm thick phenolic laminated sheet zinc plated/brass screws cup washers making connections, testing etc. as required (Group-1) on board
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor I/ sl marked (IS:694) of 1.1 KV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required, (Gr.1)(a) 2X4.0 sqmm+1.2.5 sqmm
(b)2 x 2.5 sq. mm. + 1x1.5sqmm
Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works with Galvanized box of 1.2 mm thick with earth terminal with uitablesize phenolic laminated sheet (IS : 2036 - 1995) cover includingcost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socketoutlemaking connection , testing , etc. as required. For specification ofWiring accessories refer Chapter-56 related item & For dditionaltechnical parameters of product / work refer Annexure 'A' attachedwith this BSR
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protectionand fitted in existing distribution board/sheets, minimum electricaloperation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80A & above rating including making connections, testing etc. asrequired. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional echnical parameters of product / work referAnnexure 'A' attached with this BSR
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
BOQ_964203.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid