Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 CrAccepted-AOC 4TH FLOOR MONAL TOWER NEAR SBI DISPUR DISPUR GUWAHATI 781006 ASSAM | KAMRUP METRO | ASSAM | 781006 | ₹6.4 Cr | L1 | Accepted-AOC Award to Rank L1 |
| 2 | L2₹6.7 CrRejected-AOC | ₹6.7 Cr | L2 | Rejected-AOC Not Awarded to to high Rate Bidder |
Tender Value
Refer Docs
Closing Date
3 May 2023, 2:00 pmClosed
Shri Hakim Rongpi
The District Mission Co-ordinator, Samagra Siksha, West Karbi Anglong. Dongkamukam
Construction of Permanent Building of Rongkhang, Kasturba Gandhi Balika Vidyala(KGBV)(Type-II) Rongkhang(Donkamukam- Taralangso), Kasturba Gandhi Balika Vidyalaya (KGBV) Rongkhang Block, West Karbi Anglong.
2023_KAAC_30111_1
AS/NSB-KGBV/35/2022-23/130A
Open Tender
Civil Works - Building
730 days
Donkamukam- Taralangso
APWD Registered
4 documents required · 4 mandatory
₹0
Exempted
The District Mission Co-ordinator, Samagra S
22 Sept 2023
27 Mar 2023
3 May 2023
27 Mar 2023
3 May 2023
27 Mar 2023
27 Mar 2023 - 29 Apr 2023
29 Apr 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator )/manual means over areas(exceeding 30cm in depth, 1.5 m in which as well as 10 sqm on plan) including geting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer in charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and fitting and local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc.complete
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate (12.5mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 40 mm nominal size)
1:4:8(1 Cement: 4 coarse sand(zoneIII) derived from natural source : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Making plinth protechtion 50mm thick of cement concrete 1:3:6(1 cement :3 coarse sand(zone-III)derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources) over 75mm thick bed of dry brick basllast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, leveling & dressing & finishing the top smooth.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
1: 2: 4 (1 cement :2 coarse sand(zone-III) derived from natural sources: 4 graded stone aggregate 20mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position ready mixed or size batched design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within permissible rutilization of 20% each, portland pozzolana/Ordinary Porland/Potland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/rated setting of concrete, to improve durability and workability without impairing strength, including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering , shuttering, finishing and reinforcement as per direction of the engineer -in charge, for following grades of concrete. Note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in desgn mix is more than 110% of the spesified minimum cement content, the contactor shall have discretion to either re-desgn the mix or bear the cost of extra cement.All works up to plinth level.Concrete of M25 grade with minimum cement content of 330kg/cum
All works above plinth level up to floor V level.Concrete of M25 grade with minimum cement content of 330kg/cum
Centering and shuttering including strutting, propping ect. and removal of form work for:Foundations, footings,bases of columns, etc. for mass concrete.
Suspended floors, roofs, landings,balcolonies and access platform.
Lintels,- beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Stairs,(excluding landings) except spiral-staircases
Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4(1 cement : 4 coarse sand)
Cement mortar 1:6(1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S (non modular) briks of class designation 7.5 in foundations and plinth in:Cement mortar 1:4(1 cement : 4 coarse sand)
Half brick masonary with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level.Cement mortar :1:4 (cement : 4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonary.
Providing and fixing 18 mm thick gang saw cut,mirror polished, premouled and prepolished, machine cut for kitchen platforms, vanity couners, window sills, facias and similar locations of required size, approved shede, colour and texture laid over 20mm thick base cement mortar 1:4(1 cement :4 coarse sand), joints treated with white cement, mixed with matching pigment,epoxy touch ups,inluding rubbing curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, cherry/Ruby red. Area of slab over 0.50 Sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer- in-charge.Granite work
Extra for fixing marble/ granite stone, over and above corresponding basic iteam, in facia and drops of width upto 150 mm with epoxy resin based adhesive, inluding cleaning etc. complete.
Providing and fixing 1st quality ceramic glazed wall tiles confrming to IS: 15622(thickness to be specified by the manufactureer), of approved make, in all colours, shades except burgundy bottle green, black of any size as approved by Engineer-in-charge, in skarting risers of steps and dados,over 12mm thick bed cement mortar 1:3(1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Second class teak wood. Poviding wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured)
Extra for cutting rebate in flush door shutters (total area of the shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surfaces etc. complete: 2nd class teak wood50 x 20mm
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden flugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement:3 coarse sand: 6 graded stone aggregate 20mm nominal size)
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc.complete: 300x16 mm
Providing and fixing chromium plate brass handles with necessary screws etc. complete :125 mm
Providing and fixing aluminium sliding door bolts, ISI marked anodised ( anodic coating not less than grade AC 10 as per IS:1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:300x16 mm
Providing and fixing aluminium hanging floot door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS:1868), transparent or dyed to required colour and shade, with necessary screws etc. complete: Twin rubber stopper
Anodised aluminium ( anodised transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15.) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,aluminium snap beading for glazing/ paneling C.P brass/ stainless steel screws, all mplete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately) :
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawing and the directions of engineer-in-charge. cost of aluminium snap beading shall be paid in basic item) :With float glass panes of 4.0 mm thickness(weight not less than 10kg/sqm)
steel work welded in built up section/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and flitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer-in-charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts,fasteners etc.)
Thermo-Mechanically Treated bars of grade Fe-S00D or more. Steel reinforcement for R.C.C. work including straightening, cutting, binding placing in position and binding all complete upto plinth level.
Thermo Mechanically Treated bars of grade Fe-S00D or more. Steel reinforcement for R.C.C work including straightening, cutting, `bending, placing in position and binding all complete above plinth level.
Size of Tile 600x600 mm.Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacture, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) joining with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete.
Size of the Tile 600x600 mm Glazed vitrified tiles matt/Antiskid finish of size Providing and laying vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with water absorption less than 0.080% and conforming to IS:15622,of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement morter 1:4 (1cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero- chipping daimond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles ently and easily.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from MS sheet and galvanised with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6 mm thick with flages of 27mm and 37mm, at 1200 mm centre to centre , one flanges fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate GI channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermediate channel with connecting clips made out of 2.64mm diax230mm long GI wire at every junction, including fixing perimeter channels 0.5 mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mmlong dry wall screws@ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c including jointing and finishing to a flush finish of tapered and square edges of the board with recommendedjointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coat of primer suitable for board all as per manufacture specification and also including the cost of making opening for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding- the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to Is:2095-(part-I): 2011(Board with BIS certification marks
12.5 mm thick tapered edge gypsum moisture resistant board.FINISHES.12 mm cement plaster of mix:
1:4 (1 cement : 4 fine sand). 12mm cement plaster of mix:
1:4 (1 cement : 4 fine sand). 15 mm cement plaster on the rough side of single or half brick wall of mix.
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works. Applying priming coat
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new wood over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and appying white cement based putty of average thickness 1 mm, of approved brand and manufacturer. Quote for each layer over the plastered wall surface to prepare the surface even and smooth complete.
New work (two or more coats) over and inclding water thinnable priming coat with cement primer.Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
New work(two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm).Finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade:
New work (three or more coats). White washing with lime to give an even shade:
100 mm nominal dia pipes.MANHOLE COVER. Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings this includes jointing of pipes & fitting with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge.
Circular shape 450 mm internal diameter. Providing and fixing in position pre-cast RCC manhole cover and frame of required shape and approved quality
0.63 mm thick with zinc coating not less than 275 gm/m2 . Providing corrugated GS sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and GI limpet washers or with GI limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
0.63 mm thick with zinc coating not less than 275 gm/m2 .Providing ridges or hips of width 60 cm overall width plain G.S sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
1.60 mm thick with zinc oating not less than 350 gm/m2.Providing valleys of 90 cm wide overall in plain G.S sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
Barge board(up to 300 mm).Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete:
(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry). Providing and laying water proofing treatment in sunken portion of WSs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm this layer will be allowed to air cure for 4 hours. (b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
With average thickness of 120 mm and minimum thickness at khurra as 65 mm. providing and laying integral cement based water proofing treatment- including preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations:
Constructing soak pit 1.20 x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
INTERNAL SANITARY WORKS.Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Western W.C. pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.
Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe,white PVC automatic flushing cistern with fittings, standard size GI/ PVC flush pipe for back and front flush with standard spreader pipes with fittings, GI clamps and CP brass coupling complete, including painting of fitting and cutting and making good the walls and floors etc. wherever required: single squatting plate with 5 litre PVC automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting og fittings and brackets, cutting and making good the walls wherever require: White Vitreous China wash basin size 630 x450 mm with a single 15 mm C.P. brass pillar tap.
Providing and fixing toilet paper holder C.P. brass
Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 metre long with S.S. traingular plate to Eureopean type W.C. of quality and make as approved by Engineer in charge.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 510x1040 mm bowl depth 250mm
Providing and fixing unplasticised P.V.C. connection pipe with PTMT nuts, collar and bush of approved quality and colour, 15 mm nominal bore with 45 cm length.
Providing and fixing CP brass long nose bib cook of approved qualityconforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931, 15 mm nominal bore.
15 mm nominal bore, 125 mm long foam flow,weighing not less than 120 gms
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long , 200 mm wide with minimun distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing PTMT bottle trap for wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25mm minimum water seal, weighing not less than 260 gms.
Providing and fixing PTMT grating of approved quality and colour.18.58.1 Circular type, 18.58.1.1 100 mm nominal dia
Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangments, weighing not less than 106 gms. Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS: 15801 UV stabilized & anti-microbial fusion welded, having thermal stability for hot & cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer- in-charge.
EXTERNAL WORK. PN-10 Pipe, 110 mm OD (SDR-11)
PN-10 Pipe, 90mm OD (SDR-11)
PN-10 Pipe, 75 mm OD (SDR-11)
PN-10 Pipe, 63 mm OD (SDR-11)
PN-10 pipe, 50 mm OD (SDR-11)
PN-16 pipe, 40 mm OD (SDR-7.4).
Internal Exposed on wall. PN-16 pipe, 32 mm OD (SDR-7.4)Providing and fixing 3 layer PP-R(Poly propylene Random copolymer) pipes confirming to IS: 15801, UV stabilized & anti-microbial fusion welded, having thermal stability for hot & cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer- in-charge.
PN-16 pipe, 20 mm OD (SDR-7.4) providing and fixing 3 layer pp-r(poly propylene random copolymer) pipes confirming to IS:15801,UV stabilized & anti- microbial fusion welded, having thermal stability for hot & cold water supply, concealed work, including cutting chases and making good the wall etc.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
75 mm diameter. Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
75 mm bend. Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion shoe plain.
75 mm shoe. Providind and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised rigid PVC rain water pipes conforming to IS: 5382, leaving 10 mm gap for thermal expansion.
300 mm dia. Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part-1), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire8 & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. all types of soil
100 mm nominal size dia. Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
150 mm dia nominal size dia.
EXTERNAL WORK. 40 mm nominal outer dia Pipes. Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings complete as per direction of Engineer in charge. (SUCTION PIPE)
Providing and placing in position filters of 40 mm diameter G.I./PVC pipe with brass strainer of approved quality.
Providing and fixing gun metal non-return valve of approved quality (screwed end): Horizontal
Vertical
Development of tube well in accordance with IS:2800 (Part-I) and IS:11189, to establish maximum rate of rusable water yield without send content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully devoloped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc.by step draw down method, collecting water samples & getting tested in approved laboratory,i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc, all as per requirement and direction of Engineer in charge. Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removaled as per reqirement, all complete for borewell of09-03-2023
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm dia
150 mm dia.
150 mm clamp.Providing and fixing MS clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 part-I, including necessary bolts & nuts of required size complete.
100 mm dia
150 mm dia
Gravel packing in tubwell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & sizes as per actual requirement,all complete as per direction of Engineer in charge.
Supplying including installation, connection as approved by the Deptt, testing and commissioning of SUBMERSIBLE PUMP SET 3 (three phase)with steel cable rope and submersible cable complete as directed and specified by the deptt.Three phase submersible motor pump set(Texmo/Crompton Greaves/Aquatic/CRI/V-Guar suitable for 100 mm bore well and above. 1 HP STAGE 5 to 18 with MCB controlled submersible motor pump set control panel.
Supplying including installation, connection as approved by the Deptt, testing and commissioning of JET PUMP SET (HORIZONTAL) complete as directed and specified by the deptt. 1 HP single phase Jet pump set(Horizonal(Cromton Greaves/Aquatic/CRI/V-Guard make) 2900 rpm with DOL starter (Crompton Greaves/Control & Switch Gear/BCH/L & T/Siemens make)
INERNAL ELECTRICAL WORKS. Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earting the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitalbe GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.
Wiring for circuit/ submain- wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, 2x15 sq.mm +1x1.5 sq.mm earth wire
2 x 2.5 sq.mm +1 x2.5 sq.mm earth wire
2 x 4 sq.mm +1 x 4 sq.mm earth wire
3 x 6 sq.mm +1 x 6 sq.mm earth wire
Supplying and drawing co-axIal TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the sxisting surface/recessed steel/ PVC conduit as required. Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
100 mmx 100mmx60 mm deep. Supplying and fixing metal box of following sizes(nominial size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
Seupplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding- modular plate etc. as required 5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A Socket
6 pin 15/16 A socket
TV antenna socket outlet
bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but existing modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box including modular plate as required.Supplying and fixing following size/modules,GI box alongwith modular base & cover plate for modular switches in recess etc.as required.
3 Module (100mmx 75mm)
4 Module (125mmx 75mm)
6 Module (200mmx 75mm)
8 Module (125mmx 125mm)
12 Module (200mmx 150mm) .
3 Module Supplying and fixing following Modular base & cover plate on the existing modular metal boxes etc. as required
4 Module
6 Module
8 Module
12 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on the surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc.as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 Amodular socket outlet and 15/16 A modular switch, connections etc.as required.
Supplying and fixing brass batten/angle holder including connection etc. as required.
Installation testing and comissioning of prewired, flouriscent fitting/compact flouriscent fitting of all typs, complete with accessories and tube/lamp directly on ceiling/wall including connection with 1.5 sq.mm FRLS PVC insulated, copper ,conductor single core cable and earthing etc.as required.
Installation testing and comissioning of ceiling fan, including wiring the down rods of standard length 30 cm with 1.5 sq.mm FRLS PVC insulated, copper ,conductor single core cable as required.
Installationof exhaust fan in the existing opening including making good the damages, connection, testing and commissioning etc. as required. 450 mm sweep.
12 way, Double door.Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, including earthing etc. as required. (but without MCB/RCCB/Isolator)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected , duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 4 way(4+ 12), Double door.
Single pole
Double pole.
Supplying and fixing following rating , double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc.as required.40A.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 63A.
Supplying and fixing 20 amps, 240 volts,SPN industral type, socket outlety, with 2 pole and earth, metal inclused plug top alongwith 20 amps"C" curve,SP, MCB,in sheet steel enclusure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclusure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclusure with cover plate having locking arrangement and watering pipe etc. of 2.7 metre long etc. with charcoal/coke and salt as required.
Supplying and laying 6 SWG GI wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc as required.
Providing and fixing of lightning coductor finial, made of 25 mm dia long, GI tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq.mm and upto 95 sq.mm.
3 1/2 x 70 sq.mm(38mm). Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.
3% x 70 sq.mm(38mm). Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.
Installation, testing and commissioning of prewired fluorescent fitting compact fluorescent fitting of all types complete with all accesssories and tube/lamp etc. directly on ceiling/wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Instalation, testing and commissioning of ceilin fan, including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Numbering of ceiling fan/exhaust fan/fluorescent fitting as required.
Upto 450mm sweep. Installation of exhaust fan in the existing opening, including making good the damages, connection, testing and commissoning etc. as required.
80 mm dia . Providing laying and fixing following dia GI pipe (medium class) in ground complete with GI fittings including trenching (75 cm deep) and re-filling etc. as required.
63 Amp TP & N. Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with isi marked HRC fuces including drilling holes in cubicle panel, making connections etc.as required.
160 Amp,16 KA, TP MCCB. Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
3 1/2 Corex 70 sqmm aluminium.Supplying of following sizes XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 650/1100 V grade conforming to IS 7098 (part-I)/ 1988 with a mendment upto date etc as required.
Supplying including installation, commissioning of vermin and dust proof totally enclosed, phosphatised powder painted cubical indoor type floor/wall mounting compartmentalize panel board of size 0.95 M(B)x 1.30M(H)x0.40M(D) made of 16 SWG(1.66 mm) thick CR sheet and 40mmx40mmx5mm size angle having 4 nos legs at the bottom. the panel board is to be errected in 1:3:6 PCC foundation including brick soling/ grounting etc. complete of the following electrical items:(Incoming & outgoing switch gear of reqd. rating along with meters will be measured and paid separately)
EXTERNAL ELECTRIFICATION.Earthing with GI earth plate 600mmx 600mm x 6mm thick including accessories, and providing and masonry endclusure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and solt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.upto 120sq.mm.
250Amp, 25 KA, TPMCCB. Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
63 Amp TP & N. Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
70 sqmm. Supplying and making indoor- cable end termination with heat shrinkable jointing kit complete with all acessories cast including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
3 1/2 X95 sq.mm. Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making straight through joint with heat shinkable kit including ferrules and other jointing materials for following size of PVC inslated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2 x 95 sq.mm.
Erection of matellic pole of following length in cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc.as required.Above 10.00 metre and upto 12 .00 metre.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia x 1.8 metres long stay rod, anchor plate of size 45 cm x 45 cm x7.5 mm, thimble, stay clamps, turn buckle (20 mm x60 cm),7/4.00 mm dia G.I. stay wire and strain insulator etc.in cement concrete 1:3:6 ( 1 cement: 3 coarse sand :6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supplying and erection of 30 A aerial fuse complete as required.
Erection of aerial fuse as required.
Supplying and fixing MV horn gap lightning arrestor as required.
Fixing of MV lightning arrestor as required.
Erection of angle iron/ channel iron cross arm on wood/RCC/steel tubular/rail pole etc. as required.
Supplying and erection of galvanised "D" iron clamps complete with shackle insulator (75 mmx 90 mm),G.I. bolts and nuts washers, coach screws etc. as required.
Supplying and fixing of 32 mm dia x2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent/HPMV/HPSV steet light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm x 3 mm flat iron claps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Erection of disc/pin insulator for 11 KV over head lines as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11KV overhead lines with rated voltage 9 KV( rms) with a nominal discharge current rating of 5 KV and complete with galanised clamping arrangement, G.I.bolts, nuts, washers rtc. as required.
Supplying ,installation testing and commissioning of the- 100 KVA Aluminium wound indoor/outdoor type transformer complete including the payment to the made to power supply authority for supervision charge, labour charge, cost of LT/HT metering etc.(excluding the cost of load security)and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the deptment. Transformer should be as per CEA guidelines as ammended up to date up to 200 KVA star rating up to 5 star, above 200 KVA as per CEA guidelines for losses along with LV enclosure. Supplying of following size XLPE insulated ,insulation screening with extruded semi conducting compound in combination with copper tape cores laid up inner sheath of PVC tape, galvanised flat steel strip armoured anf over all PVC sheathed cable confirming to I.S. 7098(part-II)1985 with latest amendments
Supplying of following sizes XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape cores laid up inner sheath of PVC tape,galvanised flat steel strip armoured and overall PVC sheathed cable confirming to IS7098(part-II) 1985 with latest amendment. 3CX95sqmm HT.
Supplying of following size GI pole confirming to IS: 2713.12 Mtr(SP-66)
Supplying and drawing of 11KV overhead high tension line through Racoon conductor on the existing pole struture with necessary binder pin, cross arm etc. as required complete.
Supplying including installation, testing and commissioning of 62.5 KVA Air/water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V,AC. 1/3- phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame,2) M.S fuel tank of required capacity,3) Residual Silencer,4) Standard Control panel,5) Suitable batteries with lead,5) First fill of tube oil,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical SpecIfication,as per manufacturer.
Payment of load security to the local APDCL authority.
SIDE DEVELOPMENT.Surface dressing of the ground including removing vegetation and inequalities not exceding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including remmaining and watering of the earth in layers not exceeding 20 cm in trenches,plinth, sides of foundation etc.complete
Peparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and cosilidating with road roller including making good the undulation etc. and re-rolling the sub-grade and disposal of surplus earthwith lead upto 50 meters.
Laying ,spreading and cpmpacting stone aggregate of specified sizes to WBM specifications in unifrm thickenss, hand picking, rolling with 3 wheeled road/vivratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening/ binding material to fill up intersitices of coarse aggregate, watering and compacting to the required density.
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-130 made by block making machine with strong vibratory compaction, of approve size, design & shape, laid in required colour ang pattern over and including 50 mm thick compactedbe of coarse sand, filling the joints with line sand etc.- all completed as per the direction of Engineer in charge.
BOUNDARY WALL. Earth work in excavation by Mechanical means(Hydraulic excavator/menual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift up to 1.5 n, as directed by Engineer- in charge. All kinds of Soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CEMENT CONCRETE WORKS.Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6( 1 cement : 3 coarse sand(Zone-III) : 6 graded stone aggregate 40 mm nominal size)
Poviding and laying damp-proof course 40mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate (12.5 mm nominal size).
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- all work up to plinth level:
Reinforced cement concrte work in walls(any thickness), including attached pilasters,buttresses, plinth and string courses, fillets, colunms, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25 mmx 25 mm made of G.I wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer in charge.
TIMBER SHUTTERING (FORMWORK).Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns, etc. for mass concrete.
Lintels,- beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
MASONARY WORKS.Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4( 1 cement: 4 coarse sand).
Half Brick masonary with common burnt clay F.P.S.( non modular) bricks of class designation 7.5 in Superstructure above plinth level up to floor level V.Cement mortar 1:3(1 cement : 3 coarse sand)
PLASTERING WORKS. 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4( 1 cement : 4 coarse sand). 12 mm cement plaster of mix:
1:4(1 cement : 4 fine sand)
PAINTING.Providing and appying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.Finishing walls with premium Acrylic smooth exterior paint of required shade:
New work (Two or more coat applied 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
REINFORCEMENT. Steel reinforcement for RCC work including staightening, cutting, bending , placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-S00D or more.
Electric resistance or induction butt welded tubes
Ceiling fan
LED Lights
Exhaust fan
MREEGEN SAHARIAH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid