Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer (West), UPSRTC Lucknow
Executive Engineer (West), U.P State Road Transport Corporation, H.Q. Lucknow
Developing EV charging stations at 19 UPSRTC various bus stations/workshops.
2026_UPSRT_1205635_1
1169 /B/DA/W/Tender/2026
Open Tender
Civil Works
Lump-sum
Uttar Pradesh
please refer tender documents
4 documents required · 4 mandatory
₹5,900
Executive Engineer (West), UPSRTC Lucknow
₹1.9 Cr
6 Nov 2026
6 Nov 2026
27 Nov 2026
6 Nov 2026
26 Nov 2026
6 Nov 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of 240kW EV DC Charger Vehicle Charger (suitable for Buses& truck) having minimum IK08 & IP 54 Protection suitable for three phase, 415V AC, 50Hz incomingsupply and 2 no's of 120kW outgoing charger with Dynamic load balancing, interface CCS2 with 200-1000VDC supply, interlocking arrangement with minimum 5 meter charging cable Length, 10" LCD Touch Screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, One hour battery backup for communication, emergency push stop button. User interface by mobile application/QR Code/RFID Card/Password Login including providing of software and its maintenance for all type of payment options and having short circuit, over & under voltage, input phase reversal, surge protection, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 coated with different colour and higher graded M.S material , with 1 year warranty, conforming to IS 17017.Supply, installation, testing and commissioning of 240kW EV DC Charger Vehicle Charger (suitable for Buses & truck) having minimum IK08 & IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming supply and 2 no's of 120kW outgoing charger with Dynamic load balancing, interface CCS2 with 200-1000VDC supply, interlocking arrangement with minimum 5 meter charging cable Length, 10" LCD Touch Screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, One hour battery backup for communication, emergency push stop button. User interface by mobile application/QR Code/RFID Card/Password Login including providing of software and its maintenance for all type of payment options and having short circuit, over & under voltage, input phase reversal, surge protection, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 coated with different colour and higher graded M.S material, with 02 (Two) year warranty, conforming to IS 17017.(Detailed Specificatin as per annexure-1 atteched ) | 95 | Nos | - | - |
| 2SUBHEAD-I : TRANSFORMER (11 KV / 0.4 KV) | |||||
| 2.01 | Supply, Installation, Testing and Commissioning of 1000 KVA, 11/0.433 KV, 3 Phase, 50Hz, Dyn11, Oil Filled, Copper Wound Transformer, ONAN, complete with OFF Load Tap Changer as specified, HV cable boxes, LV cable termination arrangement, first filling of transformer oil, all accessories, conforming to IS 2026 and IS 1180 latest amendments, complete in all respects.(Detailed Specificatin as per annexure-2 atteched ) | 38 | Nos. | - | - |
| 3SUBHEAD-I : TRANSFORMER (11 KV / 0.4 KV) | |||||
| 3.01 | HT PANEL
H.T. VCB (11KV) ( LOCATED IN METER ROOM)
Design, manufacturing, testing at works, supply of HT Panel as per specification and comprising of the following :-
a. INCOMER/OUTGOING PANEL
630 A Vacuum circuit breaker of 26.3 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, vertical isolation,vermin proof, fully interlocked horizontal drawout type having double isolation.
i. Manually and motor operated, spring charged (release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indicator.
ii. 630 amp air insulated but encapsulated,PVC insulated Copper bus bars.
iii. C.T. chamber with C.T.'s 160/5.
a. 15 VA burden for protection (class 5P 10).vi. All wiring necessary for the above including inter-connections. The size of the conductor should not be less than 2.5 sq. mm. Copper wire where required.
vii. Test terminal block, fuses/2A SPMCB , circuit labels,set of phase, indication lamps etc. as per standard practise as under.
a. Red - Breaker close (ON)
b. Green - Breaker open (OFF)
c. Amber - auto trip
d. Clear - trip circuit healthy
f. Blue spring charged
xi. Control :- T-N-C (Trip, Neutral. Close) breaker control switch with indication arrangement.
iv. Following protection shall be provided:
a. 1 Nos IDMT relay with instantaneous 2 nos. over currrent (50, 50 N) element and 1 no. instantaneous earth fault element(50-50N).(O/C setting 50%-200% and E/F setting 20%-80%) xii Terminal boxes with single gland trifucating cable box suitable for 11 KV Aluminium XLPE (E) cable of size 3C x 300 Sq. mm. for incoming/outgoing breaker.
xiii HT Danger Plate.(as per IS specification)
xiv. 2 Runs of 40 X 5 mm earth bus shall be provided for the full length of the panel.
xv. Power Pack, Battery power pack shall be rated for minimum five (5) trippings. For DC power one no. source selector switch to be incorporated i.e. one source from power pack and other from outside.
xvi. Necessary D.C. supply healthy indication lamp (White Colour), switch with alarm.
xvii. Surge supressor as required.
xviii. DC Voltmeter, 0-160 Volt, Digital type.
HT Panel switchboard complete with all interconnections, labels, wiring etc, complete as described above in item nos.A and B and as per specifications. | 19 | Nos. | - | - |
| 4 | H.T. PANEL (11KV)(3 PANEL BOARD)
Design, manufacturing, testing at works, supply, installation, testing and commissioning of Indoor Metal Clad, Air Insulated, Draw-out Type HT Switchboard suitable for 11kV, 3 Phase, 50Hz system comprising of 1 No. Incoming VCB Feeder and 2 No. Outgoing Transformer Feeders complete with busbars, protection, metering, control wiring, interlocking, earthing arrangement and all accessories as specified.
INCOMER FEEDER
630A, 11kV, 26.3kA Vacuum Circuit Breaker, draw-out type, motor operated spring charged mechanism, trip free operation, ON/OFF indication, anti-pumping relay, master trip relay, shunt trip coil, auxiliary contacts, space heater and all standard accessories.
Current Transformers suitable for metering and protection.Voltage Transformer 11kV/√3 – 110V/√3 complete with fuses and isolating arrangement. Numerical Over Current and Earth Fault Protection Relay (50/51 & 50N/51N). Digital Multifunction Meter. Indicating Lamps, Control Switches, Annunciation System, Test Terminal Blocks and associated control wiring complete
BUS BAR 1000 Amp Copper Bus Bar, PVC insulated, adequately rated for the connected load complete with supports and accessories.
OUTGOING FEEDERS (2 Nos.) 630A, 11kV, 26.3kA Vacuum Circuit Breaker, draw-out type complete with CTs, metering, numerical protection relay, indicating lamps, control switches, earth switch, cable termination compartment and all accessories required for feeding 1000 kVA Transformers.
EARTHING
Two runs of 65mm × 8mm GI/Copper Earth Bus throughout the panel length complete with connections. The HT Switchboard shall be complete with all interconnections, wiring, labels, terminal blocks, cable boxes, danger plates, metering, protection, testing and commissioning complete in all respects. | 19 | Nos. | - | - |
| 5SUBHEAD - III :HT CABLES Supply of 3 core stranded aluminium conductor 11KV grade XLPE (E) (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable confirming to IS : 7098 (part II with latest amendments). | |||||
| 5.01 | 185 sq. mm 3 core | 705 | Metre | - | - |
| 6Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. | |||||
| 6.01 | Above 120 sq. mm and upto 400 sq. mm | 732 | Metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Tendernotice_2.pdf
PDF • 0.34 MB
InformationOFBidder.pdf
Additional Documents • 0.39 MB
BOQ_2284755.xls
BOQ • 0.51 MB
EVCorrigendum2.pdf
PDF • 0.38 MB
EVChargingCorrigendum.pdf
PDF • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .