computer servers Average Turn Over of Last 3 Years 53 Lakh (s) Computer Servers ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Specification Form Factor Rack Rack Size (RU) 2 * Processor Make Intel Intel
AMD
SPARC Max. Number of sockets available on chipset 2 1-16 Max. Number of sockets populated with processor 2 1-16 Number of core per Processor 8 * Processor Configuration Intel Xeon Silver 4110 ( 2.10GHz/8-core/11MB/8 5W) Intel Xeon Silver 4110 ( 2.10GHz/8-core/11MB/8 5W) Chipset compatible with CPU LATEST INTEL CHIPSET * Availability of Co- Processor No * If Yes Co-Processor NA * 1/4 Configuration PCI Slots (Express Gen 3.0) 8 * Type of RAM DDR4 * RAM Size (GB) 64 64 RAM upgradable upto (GB) 3000 32-24000 DIMM Slots (No.) 24 * Type of Hard Disk Drive SAS SAS
NL SAS
SSD
SATA Hard disk drive Capacity (GB) 7200 7200
6300
6000 Hard disk drive Speed (RPM) 15K * RAID Controller Cache (MB) 2048 * RAID Type 5 * RAID Controller Ports @12 Gbps 2 * Video Controller (support VGA or above resolution) Yes * Keyboard Yes * Mouse Yes * Bays (min. 2 internal or more hot plug) 8 * USB Ports (version 2.0/3.0) 4 * Certifications Compliance support by Windows
Red Hat or Novell or Oracle Cluster S/W Yes * DVD ROM (or better) 8x or better * Network Card Supported 1G
10G
25G * FC HBA Dual port card NA * FC HBA Dual port card Speed NA * Power Management - * Redundant Power Supply Yes * Redundant Fan Yes * Total No of Ports 4 x 1GE * 2/4 Declare SPEC int_rate_base 2006 ; specfp_rate_2006 for 1
2
4
8 prcessor as applicable SPEC CPU® 2006 benchmark should be 687 (60% SPECint_rate _base2006+ 40% SPECfp_rate_base2006) * Server scalability to be achieved within the box without adding nodes Yes * RoHS Compliance Yes * BIS Registration number & its Validity - * Max. power consumption of the system (Watt) 750 * Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server shall be checked for all the parameters before conditioning
After completion of the above environmental tests sequence
with a recovery period of 1 to 2 hrs
the server shall be functional No * Name address of Lab - * Test Report No. date - * Power Supply 230 V +/-10%
50 Hz * On Site OEM Warranty (years) 5 1
3
5 (or higher) 3/4 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Norendra Khuraijam 795004
Office of the Chief Electoral Officer
Lamphel Game Village Road
Destrict- Imphal West
Pin-795004 2 15