Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC B 1203 VRINDA RESIDENCY BARIATU ROAD RANCHI JHARKHAND 834009 | RANCHI | RANCHI | JHARKHAND | 834009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.7 L+₹1.4 L (3.67%)Rejected-Finance SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | L2 | Rejected-Finance Quoted amount is more than L1 | |
| 3 | L3₹48.6 L+₹10.3 L (26.8%)Rejected-Finance | L3 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Dec 2021, 6:00 pmClosed
Major S Rakesh
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REP/REPLACEMENT OF ELECT FITTINGS/FIXTURES INCLUDING REWIRING AND CONNECTED E/M WORK SERVICE FOR MH NAMKUM AND REP/MAINT OF CI/GI DISTR MAINS AT 1 (I) R AND O FLIGHT, ENGR LINE, 3/8 GR UNIT LINE, EME BN, REST CAMP, VEER LINE AND LPH UNDER GE RANCHI
2021_MES_490435_1
8400/1123/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class D Cat a(ii) and b(i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹80,000
Yes
14 Jan 2022
25 Nov 2021
23 Dec 2021
26 Nov 2021
21 Dec 2021
9 Dec 2021
Amount
Taking down carefully aluminium point wiring (light, Socket or power) complete including fittings and fixtures such as switches, ceiling roses pendents, regulators, sockets etc for re use to be measured separetly including making good the disturbed portion/surface complete all as specified and directed.
M&L for point wiring with colour coding multistranded copper conductor cable, PVC insulated (FRLS) and unsheathed size 1.5 sqmm with conceled Conduit with fixing accessories, to be fixed , for one light /fan/bell point controlled by one switch with sunken box of suitable size incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly all as specified and directed.
All as per item No 2 but for one 3/5 pin socket 5 Amp on independent board.with 1.5 Sqmm wire with 1.5sqmm earth wire complete all as specified and directed.
All as per item No 2 but for one 3/5 pin socket 5 Amp on same board, with 1.5 Sqmm wire with 1.5 Sqmm earth wire complete all as specified and directed.
All as per item No 2 but for 3 pins socket outlet 15 Amps independent with 4 sqmm incl continous earthing with multi standred copper conductor PVC insulated unsheathed size 4.0 Sqmm, complete all as specified and directed.
M&L for point wiring with colour coding multi stranded copper conductor cable, PVC insulated (FRLS) and unsheathed size 1.5 Sqmm with conceled Conduit with fixing accessories, to be fixed , for one light /fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick modular plate incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly all as specified and directed. Note :- Modular cover plate of any module with all fittings are included in point wiring.
All as per item No 6 but for one 3/5 pin socket 5 Amp on independent board.with 1.5 Sqmm wire with 1.5sqmm earth wire complete all as specified and directed.
All as per item No 6 above but for one 3/5 pin socket 5 Amp on same board, with 1.5 Sqmm wire with 1.5sqmm earth wire complete all as specified and directed.
All as per item No 6 above but for 3 pins socket outlet 15 Amps independent with 4 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sqmm complete all as specified and directed.
S&F switch piano flush type/Bell push, 5 Amps, single pole one way. (Make : Anchor/Havells/Indoasian (ISI marked)
S&F socket 5 pins, 6 Amp, flush type piano (multi purpose), (Make : Anchor/Havells/Indoasian (ISI marked)
S&F Socket 15 Amps flush type 230 Volts , AC complete. (Make : Anchor/Havells/Indoasian (ISI marked)
S&F switch 15 Amps flush type 230 Volts , AC complete. Make : Anchor/Havells/Indoasian (ISI marked)
S&F switch modular type (ISI marked confirming to IS 3854:1997), single pole, one way 10 Amp, 240 Volts complete all as specified & directed.
S&F switch modular type (ISI marked confirming to IS 3854:1997), single pole, one way 15/16 Amp 240 Volts complete all as specified & directed.
S&F socket modular type (ISI marked) confirming to IS 1293:2005, single pole, 6 Amps 2 pin/ 3 pin, 240 Volts complete all as specified & directed.
Supply & fixing socket modular type (ISI marked) confirming to IS 1293:2005, single pole, 6/16 Amps twin 3 pin power socket ,240 Volts complete all as specified & directed.
S&F 5 step fan regulator modular type (ISI marked confirming to IS 3854:1997)), single pole, 240 Volts complete all as specified & directed
S&F Bell push modular type (ISI marked confirming to IS 3854:1997), single pole, 5/6 Amp , 240 Volts complete all as specified & directed
S&F 5 step fan regulator single pole, 240 Volts complete all as specified & directed. Make- Anchor/Havells
M&L for point wiring with colour coding multi stranded copper conductor cable, PVC insulated (FRLS) and unsheathed size 1.5 sqmm with PVC casing caping with fixing accessories, to be fixed , for one light /fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet/modular plate incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly all as specified and directed.
All as per item No 21 but for one 3/5 pin socket 5 Amp on independent board.with 1.5 sqmm wire with 1.5sqmm earth wire complete all as specified and directed.
All as per item No 21 but for one 3/5 pin socket 5 Amp on same board, with 1.5 Sqmm wire with 1.5sqmm earth wire complete all as specified and directed.
All as per item No 21 but for 3 pins socket outlet 15 Amps independent with 4 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sqmm complete all as specified and directed.
S&F Ding Dong door bell complete. Make : Anchor/Havells/Indoasian ( ISI marked)
S&F ceiling rose, surface backlite, 65x50mm, three terminals. Make : Anchor/Havells/Indoasian ( ISI marked)
S&F angle lamp holder PVC/Polycarbonate base / back suitable for CFL lamp. Make : Anchor/Havells/Indoasian ( ISI marked)
S&F LED bulkhead 10W with IP 65 protection 240V. Make- Bajaj Havells or equivalent in Phillips
S&F LED Mirror Light 10 Watt with diffuser, Decorative type,complete all as specifed & directed by Engr-in - charge. Make : Crompton or equivalent in Phillips/ Havells
S&F LED bulb 10 Watt suitable for angle lamp holder base B-22 230V ,complete all as specifed and directed. Make : Crompton or equivalent in Phillips/ Havells
S&F 20W LED 6000K (4’) wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver, optics diffused, complete all as directed by Engineer-in-Charge. Make : or equivalent in Havells bajaj
S&F 36W LED 6000K (2X2) pannel light mounted white powder coated luminaire screwless design, complete all as specified and directed. Make : Havells or equivalent in Crompton/ Phillips/ Bajaj
S & F decorative wall mounting chrome finish 6W LED fitting and provn of three core cable of copper conductor of size 1.5 sqmm for electric connection including all necessary fixing arrangement on wall/ceiling complete all as directed Make : Havells cat part No. LHEHCXPBIN1W006 or equivalent of Wipro/Philips/Bajaj.
Dismantling and taking down existing unserviceable submain wiring from batten/conduit of any size and making good to disturbed surfaces to match the existing surfaces.
M&L for submain wiring with 2X6.0 SQMM+1X6.0SQMM Earth Wire single core PVC insulated FRSL sheathed cooper cable connecting to common earth dolly in and including heavy duty in concealed conduit including taking down old wiring all accessories complete all as specified and directed. Make- Havells/Finolex
Dismantling and taking down existing unserviceable cable of any size and making good to disturbed surfaces to match the existing surfaces.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core including taking down and laying with excavation, all laying mtrls, GI pipe, boring as per site requirment use for services connection as per specification, complete all as specifed and directed . Make- Grandlay/Havells/Finolex
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core including taking down and laying with excavation, all laying mtrls, GI pipe, boring as per site requirment use for services connection as per specification, complete all as specifed and directed. Make- Grandlay/Havells/Finolex/CCI
S & Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core including taking down and laying with excavation, all laying mtrls, GI pipe, boring as per site requirment use for services connection as per specification, complete all as specifed and directed. Make- Grandlay/Havells/Finolex
Taking down unservicable main switches MCB's DB's etc any type and capacity including making good the disturbed surfaces to match the existing.
S&F single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link , earth bar and din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 10 ways. Make:-Indoasian/Havells / Legrand / L&T .
All as per item No 41 but 8 ways
All as per item No 41 but 4 ways
S&F MCB SPN 32 to 63Amps 415V incl all termnials, fitting etc. Make:-Indoasian/Havells / Legrand / L&T .
S&F MCB SP 06 to 40 Amps 415V incl all termnials, fitting etc. Make:-Indoasian/Havells / Legrand / L&T .
S&F MCB TPN 40 to 63 Amps 415V incl all termnials, fitting etc. Make:-Indoasian/Havells / Legrand / L&T .
S&F Distribution board 4 way TP&N Vertical loadline double door are fitted with Bus Bars, Neutral Links, Blanking Plates, Suitable for FP MCCB. Make:-Havells / Legrand / L&T
S&F CRCA sheet metal enclosure double door, outdoor type suitable size for Energy meter Fixed with cable terminals incl 3 nos HDPE gland fixed on pole/wall/panel/where direction by Engr in charge with clamp nuts,bolts, PCC etc all as directed by Engr in charge Make:-Indoasian/Havells / HPL / L&T .
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4 mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 20 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion.
Excavation in trenches not exceeding 1.5 wide and not exceeding 1.5 mtr in depth in soft/ loose soil for laying of pipes and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose soil, complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point, complete all as specified.
Taking up or down GI tubing and connection and stacking neatly for reuse and removing the balance material from site of size 15 mm bore, complete all as specified and directed.
All as per item No 53 above but of 20 mm dia.
All as per item No 53 above but of 25 mm dia .
All as per item No 53 above but of 40 mm dia.
All as per item No 53 above but of 50 mm dia.
Refixing only of old GI tubing obtained from Item No 53 of Sch 'A' above and connections in new or old position (Walls, trenches, ceiling and floors etc) of size 15 mm bore, complete all as specified and directed.
All as per item No 58 above but obtained from item No 54 of 20 mm dia.
All as per item No 58 above but obtained from item No 55 of 25 mm dia.
All as per item No 58 above but obtained from item No 56 of 40 mm dia.
All as per item No 58 above but obtained from item No 57 of 50 mm dia.
S&F in replacement tubes, 'medium grade', galvanized, with all fittings; laid in trenches of following sizes :-
15 mm bore dia
20 mm bore dia
25 mm bore dia
40 mm bore dia
50 mm bore dia
80 mm bore dia
S&F in replacement tubes, 'medium grade', galvanized, with all fittings and fixed to complete to walls and ceiling or laid in floors of following sizes :-
15 mm bore dia
20 mm bore dia
25 mm bore dia
S&F in repair stop valves cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions, heavy duty ISI marked and fixed of size 15 mm bore, complete all as specified and directed. Make : Shakti/Leader/Kirloskar/ Kejriwal/BIR.
All as per item No 65 above but of size 20 mm bore.
All as per item No 65 above but of size 25 mm bore.
S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, for following bore dia:Make-Shakti/Scud, for the following bore dia :- Note :- Gate valve fixed and removed at different places.
50 mm dia
40 mm dia
25 mm dia
20 mm dia
15 mm dia
M&L cutting of existing GI/CI/DI pipe of nominal bore 100 mm for insertion of tee, socket, union, nipple of appropriate size and dimensions where required including stop leakage etc, complete all as specified and directed. Note :- (i) In case of CI/DI pipe line insertion of rubber flange necessary nut bolts and washers etc and run lead jointing. The same should be measured and paid for separately under the respective items of Sch 'A'. (ii) In case of GI pipe, the necessary fittings involved shall be measured and paid for seperately under the respective items of sch 'A'.
All as per item No 69 above but of size 50 mm dia GI pipe
All as per item No 69 above But of size 40 mm dia GI pipe.
All as per item No 69 above but of size 25 mm dia GI pipe, complete all as specified and directed.
All as per item No 69 above but of size 20 mm dia GI pipe, complete all as specified and directed.
M&L Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot), complete all as specified and as directed, upto 150mm bore dia collars, caps and plugs.
M&L Bends, Tapers, Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged all as specified and as directed , upt 150mm bore dia
M&L Rubber gasket joint for flange joint, complete all as specified and as directed upto 150mm bore dia.
S&F replace cast iron sluice valve with flanged ends, confirming to IS-780 type PN-1.6 cast iron body with CI wheel brass spindle, joints with rubber gaskets including bolts nuts and washers complete with ISI mark size 150 mm CI line in position, complete all as specified and directed.
All as per item No 77 above but size 100 mm bore pipe.
All as per item No 77 above but size 80 mm bore pipe.
M&L run lead joint suitable for 100 mm bore CI pipe, complete all as specified and directed.
M&L run lead joint suitable for 150 mm bore CI pipe, all as specified and directed.
S&F the CI NRV 100 mm dia with all fitting, complete all as specified and directed. Make : RMCO
S&F the CI NRV 80 mm dia with all fitting, complete all as specified and directed. Make : RMCO
S&F the CI NRV 50 mm dia with all fitting, complete all as specified and directed. Make : RMCO
S&F the CI ARV 80 mm dia with all fitting, complete all as specified and directed. Make : RMCO
S&F the CI ARV 100 mm dia with all fitting, complete all as specified and directed. Make : RMCO
S&F foot valve brass 100mm dia with all fitting, complete all as specified and directed. Make : RMCO
S&F foot valve brass 80mm dia with all fitting, complete all as specified and directed. Make : RMCO
S&F foot valve brass 50mm dia with all fitting, complete all as specified and directed. Make : RMCO
S&F foot valve brass 40mm dia with all fitting, complete all as specified and directed. Make : RMCO
M & L opening dismentling pump set 1/2 HP and taking out defective motor pump of any capacity from site, transporting to work shop for repair and rewinding with supper enameld copper conductor as per existing size and guage as recommended by OEM including varnishing drying cleaning to slots repair to any damage slot for smooth functioning of motor testing& transporting back at site ofter repair and refixing the same on its position reconnection testing, complete all as specified and directed.
M & L for Opening the pump 1/2 HP assembled with motor trace out the defective parts of the pump melting grinding the shaft by lath machine to make as per original Shape and size and fixing the new parts as required, complete all as specified and directed.
M & L transporting burnt Pressure Booster pump motor of 2 HP to work shop for opening the elect motor single phase 230 volt and rewinding with supper enameld copper conductor as per existing size and guage including varnishing drying cleaning to slots repair to any damage slot for smooth functioning of motor testing, opening the pump assembled with motor trace out the defective parts of the pump melting grinding the shaft by lathe machine to make as per original Shape and size and fixing the new parts as required & transporting back at site ofter repair and refixing the same on its position reconnection testing, complete all as specified and directed.
M&L in repairs rotational moulded polythene water storage tank three layered (Cylindrical vertical with closed top) hoisted and fixed in position including taking out of existing unserviceable tank of capacity 500 Ltrs, complete all as specified and directed. Make: Sintex/Rotex/Ploycon/Tuff/Dhara.
All as per item No 94 above but of size 1000 Ltr capacity.
Dismantling of existing/damaged masonry valve chamber of any size, complete all as specified and directed.
Construction of Brick masonry valve chamber of size (90 x 90 x 105) cm (internal dimension) chamber depth to be reckoned from the top of PCC foundation to top of brick wall, including PCC 1:4:8 type D-2 in foundation PCC 1:2:4, type B-1 in coping, brick work in cm 1:4, plaster 15 mm thick in CM 1:4 flush pointing externally as the work proceeds in CM (1:4), MS sheet cover 3.15 mm thick with handle and locking arranging and angle iron frame of size (25 x 25 x 5 mm) including painting with two coats of synthetic enameled paint over a coat of red oxide primer, complete all as specified and directed.
M&L PCC in foundations & mass concrete etc type B-1, 1:2:4 with 20 mm graded aggregate, complete all as specified and directed.
S&F in repairs valve pit chamber cover of MS sheet cover 3 mm thick with handle and locking arrangement including painting with two coats of synthestic enamelled paint over a coat of red oxide primer, complete all as specified and directed.
S&F in repairs ball valves high pressure of PTMT complete with epoxy coated aluminum rod and HDPE Ball of size 15mm dia, complete all as specified and directed. Make : Prayag/LEADER/KIRLOSKAR/BIR Jalandhar.
All as per item 100 above but of size 25 mm bore.
All as per item No 100 above but of size 20 mm bore.
BHARATI ENTERPRISES
M/S Sahib N Sahiba Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .