| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹33.3 L+₹2.0 L (6.29%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹33.4 L+₹2.0 L (6.51%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹34.1 L+₹2.8 L (8.86%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹35.5 L+₹4.1 L (13.2%)Rejected-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Feb 2021, 6:00 pmClosed
GE West Lucknow
11, Sardar Patel Marg, Lucknow Cantt
REPAIR TO JOINERY COMMA CUPBOARDS ETC AND REPAIR TO DRAIN COMMA FENCING AND FOOTPATH ETC IN ZONE A AREA OF AGE BR I UNDER GE WEST LUCKNOW
2021_MES_416407_1
GE/W/LKO/76 OF 2020-21
Open Tender
Civil Works
Item Rate
270 days
Lucknow Cantt
Class D
Cat a i
8 documents required · 8 mandatory
₹500
GE West Lucknow
₹80,000
Yes
17 Mar 2021
27 Jan 2021
25 Feb 2021
27 Jan 2021
23 Feb 2021
11 Feb 2021
27 Jan 2021 - 9 Feb 2021
Amount
Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles etc. complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness, laid, bedded and pointed in any mortar in floors, aprons etc. complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. NOTE: Reinforcement shall be cut as required to facilitate demolition.
Dismantling of framed work of timber scantlings 40 sq cm and over in section, in any position complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section embeded in natural ground including taking out embedded portion and making good disturbed gound complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section embeded in concrete, brick work, masonary etc., including taking out embedded portion and making good disturbed gound complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc. 0.5 cum getting out, returning, filling in, and ramming earth or broken rubble mixed with earth around in layer n.exc. 25 cm including watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/ loose soil complete all as specified and directed.
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25cm in soft/ loose soil complete all as specified and directed.
Removing surplus excavated material soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L brick work with old size fly ash bricks of class designation 75, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
All as per item no. 14 above but except bricks. NOTE: Brick retrieved from demolition shall be used
M&L for brick work with old size fly ash bricks of class designation 75, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as specified and directed.
M&L Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other bands, plinth courses, string cources, lacing cources, parapets and railing upto 60cm in hight, copings, kneelers, apex stones, bed plates, water troughs, hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
M&L Mild Steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L Mild Steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L Mild Steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts and similar works complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions and similar works for rough finished surfaces complete all as specified and directed
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area n. exc 1.50 Sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exc 1.50 Sqm but n. exc 4sqm each complete all as specified and directed.
Taking down shutters of any description, area n. exc 1.00sqm each complete all as specified and directed.
Taking down shutters of any description, area exc 1.00sqm but n. exc 2.00 Sqm each complete all as specified and directed.
Taking down shutters of any description, area exc 1.00sqm but n. exc 2.00sqm each and refixing in same opening complete all as specified and directed.
S&F 2nd class hard wood, plain, solid, straight, chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints and fixed complete all as specified and directed.
S&F 35mm thick factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc, (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut or mitred beads for securing glass, gauge etc sizes of members of shutters as specified in SSR Part-I Section 8 clause 8.24(a) and fitted to chowkats complete all as specified and directed.
S&F 30mm thick factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc, (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut or mitred beads for securing glass, gauge etc sizes of members of shutters as specified in SSR Part-I Section 8 clause 8.24(b) and fitted to chowkats complete all as specified and directed.
S&F flush shutters 30 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 35mm thick factory made 2nd class hard wood rail and style type plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial venneering on both faces, the size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
Taking down side hung, aluminium door shutters of any description, area exc 1.50Sqm but n. exc 4.00sqm each and refixing in same opening including provn of easing, necessary repair like replacement of aluminium beading, aluminium hinges, jointing cleats, glazing clips, rubber packing, screws etc complete all as specified and directed.
Taking down side hung, aluminium window shutters of any description, area n. exc 1.50Sqm each and refixing in same opening including provn of easing, necessary repair like replacement of aluminium beading, aluminium hinges, jointing cleats, glazing clips, rubber packing, screws etc complete all as specified and directed.
S&F Anodized aluminium frame for doors, windows, ventilators with one or more rebates using 1.50mm thick aluminium section including joining cleat for fixing etc. complete all as specified and directed.
S&F in repair anodized aluminium glazed window and ventilator shutters, fixed type, with sash bars, with aluminium section weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc. complete all as specified including glazed with 5mm thick tinted glass complete all as specified and directed.
S&F in repair anodized aluminium glazed window shutters, sliding type, three track (two of glass and one of stainless steel wire cloth) without sash bars, with aluminium sections weighing not less than 0.55kg/m and three track aluminium sections of size 100x38x1.50mm including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, fibre wheel rollers, anodized aluminium fittings such as hinges, tower bolts and handles etc. including glazed with 5mm thick tinted glass and wire meshed with stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and directed.
S&F 28mm thick factory made 100% solid PVC flush shutter, made out from co-extruded three layer rigid foam sheet (single extruded) duly prelaminated with 1mm thick both side decorative lamination layer of density 1400 Kg/cum and central core of density not less than 600 Kg/cum and manufactured by an ISO 9001-2015 certified company and fixed to frame at site as per specification complete all as specified and directed.
S&F 18/19mm thick factory made 100% solid PVC flush shutter, made out from co-extruded three layer rigid foam sheet (single extruded) duly prelaminated with 1mm thick both side decorative lamination layer of density 1400 Kg/cum and central core of density not less than 600 Kg/cum and manufactured by an ISO 9001-2015 certified company and fixed to frame at site as per specification complete all as specified and directed.
S&F Solid PVC frame (single rebated) size 60x30mm made out of solid PVC foam with homogeneous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100x8 sheet metal CSK screws complete all as specified and as shown on drawing. NOTE: Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.
S&F casement windows with net and grill single or multi shutter, made out of uPVC multi cavity frame section of size 60x60x2.5mm, suitably reinforced, and double multi shutters division are made by using sash mullions of uPVC section of size 50x64x2.5mm, shutters made out of uPVC section of size 50x85x2.5mm, reinforced and welded in corners with EPDM gasket for provn of glass and air tight, outer side of shutter glazed with 5mm thick sheet glass and mosquito shutter made out of uPVC extruded section of size 61x27x2mm with 1.2mm thick GI channel, welded in corners, fibre mosquito net fitted in shutter with required accessories, 12mm round grills are inserted in main frame and fixed as per manufacturer's instructions complete all as specified and directed.
S&F 100mm size stainless steel, butt hinges, medium weight and fixed with screws complete all as specified and directed.
S&F 100mm size butt hinges, medium weight, cold rolled, mild steel and fixed with screws complete all as specified and directed.
S&F 75mm size butt hinges, medium weight, cold rolled, mild steel and fixed with screws complete all as specified and directed.
S&F 150mm size extruded aluminum alloy handles, fabricated type, anodised complete all as specified and directed.
S&F in repair 150mm size extruded aluminum alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 100mm size extruded aluminum alloy handles, fabricated type, anodised complete all as specified and directed.
S&F in repair 100mm size extruded aluminum alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 200mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F in repair 200mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F in repair 150mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F in repair 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F in repair door closer, aluminium (die cast) body, hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S&F in repair rubber beading of size 65x5mm, superior quality and fixed to bottom of door with nails and washer etc. complete all as specified and directed.
M&L in repair 18/19mm thick block boards, grade 2 quality, interior grade, commercial type fixed with screw/ nails to timber frame work as in pelmet boxes/ cup boards and cabinets etc including 6mm thick teak wood lipping alround complete all as specified and directed.
M&L 0.90mm thick decorative laminates type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
S&F Continuous (piano) hinges, mild steel, bright finished or electro galvanised, with width of flap 30mm when open, and fixed with screws complete all as specified and directed.
S&F 100mm long aluminum anodised, hasp and staple, safety type, with mild steel hinge pin including bolts to hinge plate and fixed with screws complete all as specified and directed.
S&F 300mm long, mild steel, ordinary rat tail rod pattern springs including including roller and roller plate complete all as specified and directed.
S&F in repair 300mm long, mild steel, ordinary rat tail rod pattern springs including including roller and roller plate complete all as specified and directed.
S&F Ball catches (magnet catcher) with 8mm dia steel ball, brass body and striking plate including letting in, overall size 50x15mm and fixed to shutter complete all as specified and directed.
S&F in repair 50mm dia, polished, hard wood knobs for cupboards, decorative, fixed with nut, screws and washer, bright finished complete all as specified and directed.
S&F floor door stopper two legged of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor, overall length of cover plate 150mm complete all as specified and directed.
S&F in repair floor door stopper two legged of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor, overall length of cover plate 150mm complete all as specified and directed.
S&F in repair 20mm dia mild steel chromium plated pipe, superior quality, as in cloth hanging rod with end brackets and fixed with wooden plug/ PVC gully with CP screws and cup washers complete all as specified and directed.
S&F in repair 0.56mm thick plain Aluminium sheeting, Alloy 31000 H4, fixed with nails to wooden frame work complete all as specified and directed.
M&L 3mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads in square, area n.exc 0.5 Sqm in each pane complete all as specified and directed.
M&L in repair 3mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads in square, area n.exc 0.5 Sqm in each pane complete all as specified and directed.
M&L for 4mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads in square, area n.exc 0.5 Sqm in each pane complete all as specified and directed.
M&L 5.5mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads in square, area exc 0.5 Sqm in each pane complete all as specified and directed.
M&L for securing glass of any description in existing metal frames glazed with putty/ beads including removing loose or decayed putty/ beads, painting/ oiling one caoat on rebates, grooves, reputtying and painting/ oiling puttied surface to match existing work (only new length of frame re-puttied shall be measured) complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repair mild steel window handle, left or right, heavy duty, superior quality and fixed with necessary fixing arrangement complete all as specified and directed.
S&F in repair mild steel window peg stay for support of window panel, heavy duty, superior quality and fixed with necessary fixing arrangement complete all as specified and directed.
M&L 2nd class hard wood, plain fillets, sectional area exc 3sqcm but not exc 6sqcm, square, rectangular or triangular in secction, wrought finished, secured with nails or brads complete all as specified and directed.
M&L in repair 2nd class hard wood, plain fillets, sectional area exc 3sqcm but not exc 6sqcm, square, rectangular or triangular in secction, wrought finished, secured with nails or brads complete all as specified and directed.
M&L for Running welding in repairs, thickness of metal to be welded n. exc 6mm thick including cleaning, preparing surfaces to be welded and bevelling of edges, as required complete all as specified and directed.
M&L for welding in repairs not exc 2.5cm in length, thickness of metal to be welded n. exc 6mm thick including cleaning, preparing surfaces to be welded and bevelling of edges, as required complete all as specified and directed.
S&F in repair false ceiling with 4mm thick 'E' Board (Make: Everest) of size 600x600mm, white, prelaminated sheet embossed reinforced designer ceiling board tiles of approved texture and powder coated, hot dipped GI imposed grid frame work complete all as specified and directed including all necessary drilling, cutting to fix electrical items as under with the following:- (a) 24x24x0.45mm thick powder coated GI angle plugged @ 600mm c/c along perimeter of wall. (b) 24x32x0.33mm thick powder coated GI tee as main and cross runners suspended with 4mm dia GI wire suspenders with adjustable clamps and dash free fastners with rawl plug and screws plugging in RCC slab etc. placed @ 600mm c/c from perimeter of wall. (c) Fixing of 4mm thick 'E' board tiles and finished complete with one coat of oil emulsion distemper on ceiling. NOTE: The complete ceiling work shall be executed as per manufacturer's instructions and as directed.
S&F in repair 4mm thick 'E' Board (Make: Everest) of size 600x600mm, white, prelaminated sheet embossed reinforced designer ceiling board tiles of approved texture including all necessary drilling, cutting to fix electrical items complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated etc.) sheets in roof coverings complete all as specified and directed.
S&F multi-rib TM profile, tensile strength 550 Mpa, colour coated 0.50mm thick pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet, having maximum pitch of 250mm c/c and minimum 30mm crest depth in length as per site requirement, the feed material manufactured out of 0.50mm (TCT) with coating of 18-20 microns top coat over 5 microns primer and 8-10mm alkaline back of zinc aluminium alloy of AZ-150, including the sheet shall have a hot dip metallic zinc aluminium alloy coating of zinc 43.5%, aluminium 55% and silicon 1.5% with total mass coating of 150 gms/sqm on both sides having covered width 1020mm and return leg for proper side lap as in roof covering/ cladding and fixed with self tapping screws with EDPM seal complete all as specified and directed.
M&L 6mm thick corrugated or semi corrugated asbestos cement sheet in roofs, walls etc. and fixed with L-type or J-type or cranked hook bolts with washer complete all as specified and directed.
M&L for cutting holes in brick walls built in cement or cement lime mortar for inserting hold fasts, etc and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-21 as required; depth of cutting exceeding half brick but not exceeding one brick complete all as specified and directed.
M&L in repair mild steel framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L mild steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintel hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290, Gde E-165 complete all as specified and directed.
M&L 1.0mm thick mild steel, plain black sheet in hearths, covering to door shutters, covering to door chowkats (frames), chullah hoods, water tanks, water troughs, ducts, urinal troughs and funnels, etc. cut to size, edges beaded if directed, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel members, etc. with plain 40mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed.
M&L in repair structural steel work with rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc and similar articles conforming to Fe-410W (Gde E-250) quality-A complete all as specified and directed.
M&L in repair structural steel work with rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. and similar articles conforming to Fe-410W (Gde E-250) quality-A complete all as specified and directed.
S&F Structural steel framed work with rolled mild steel sections as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing conforming to Fe-290 (Gde E-165) complete all as specified and directed.
M&L cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L mild steel framed work such as posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting and/or welding etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F in repair galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provn of galvanised mild steel wire, staples or steel pins etc. complete all as specified and directed. NOTE: Each line wire to be measured.
Labour only for restraining, resecuring including making good staples etc. of galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provn of galvanised mild steel wire, staples or steel pins etc. complete all as specified and directed. NOTE: Each line wire to be measured.
Fixing only chain link fencing including line wires, any mesh size and type to any type of standards rails, straining bolts, etc. including provn of galvanised mild steel binding wire of 0.9mm dia annealed complete all as specified and directed.
Supply only 3mm dia GI wire chain link fencing of mesh size 75x75mm and any type complete all as specified and directed. NOTE: Weight constant of fencing shall be fixed by BOO.
Supply only mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, 5 to 10mm dia of neck, length of bolts exc. 5cm but not exc 10cm long complete all as specified and directed. NOTE: Weight constant shall be fixed by BOO.
Taking down cement or cement lime plaster any description from walls/ceiling etc including racking out joints, hacking for key & scrubbing down with water all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of wall and finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface of wall and finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 with integral water proofing compound @ 3% by weight of cement on fair faces of brick work or concrete surface of wall and finished surface even and smooth without using extra cement complete all as specified and directed. NOTE: WPC shall be measured and paid seperately under respective item.
Supply only integral waterproofing compound complete all as specified and directed.
M&L for two coats of oil bound distemper over one coat of primer on newly plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
M&L for two coats of cement base paint over one coat of primer on newly plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
M&L for three coats of white wash on newly plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of wood or wood based materials of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel or iron of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old or previously treated surfaces of wood or wood based materials of any description over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old or previously treated surfaces of steel or iron of any description over 10cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for 40mm thick cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in floor, finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection, laid in panels, finished surface even and smooth without using extra cement and forming 12mm wide expansion joints to the full depth, and filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonary), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match and similar works set in cement mortar 1:4 complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves etc and similar works set in cement mortar 1:4 complete all as specified and directed.
M&L in repair 35mm thick (measured solid) precast cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in louvres and jallies including all mouldings and similar works set in cement mortar 1:4 complete all as specified and directed.
M&L 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub bases of floors and pavings etc. finished even and fair without using extra cement complete all as specified and directed.
M&L for 60 mm thick M-35 grade factory made machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 with grey cement and pigment as approved laid over and including 25mm thick sand cushion and joints filled with sand complete all as specified and directed.
M&L for 60 mm thick M-35 grade rubber moulded factory made machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 with grey cement and pigment as approved laid over and including 25mm thick sand cushion and joints filled with sand complete all as specified and directed.
S&F Exterior finish floor tiles of size 300x300x25 mm thick, superior quality, approved shade, set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floor including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. Make: Endura/ Duracrete/ Naveen/ Eurocon/ NITCO.
M&L for factory made chequered cement concrete tiles of size 250x 250x 25mm thick, superior quality, set, jointed and pointed in neat cement slurry with grey cement and pigment as in floor including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L Continuous brick edging using old size sub class 'B' bricks, with width equal to the width of brick, laid dry, on edge complete all as specified and directed.
S&F in repair peg set of 6, stainless steel, fancy type, with 40mm wide stainless steel strip, fixed to wall with wooden plug/ PVC gully with CP screws and cup washers complete all as specified and directed.
S&F in repair 25mm dia mild steel PVC coated curtain rod, superior quality, any colour, with end bracket and end knobs and fixed to wall with wooden plug/ PVC gully with CP screws and cup washers complete all as specified and directed.
S&F in repair 20mm dia stainless steel CP curtain rod, superior quality, with end bracket and end knobs and fixed to wall with wooden plug/ PVC gully with CP screws and cup washers complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (using 40 mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
S&F in repair Concertina coil fencing with punched tape coil 450mm dia (at stretched position), made out of hot dipped, galvanised steel wire coated with CLR anti corrosive paint, making diamond shape barbs with 18 SWG sheet, spring core 2.5mm thick wire with tape 0.52mm thick and weight of each coil should not be less than 7.50 Kg, each coil should have 50 rounds and should covers 6 RM length, fixed over and including 6 lines of horizontal RBT (reinforced barbed tape) wire or razor wire at points wherever coil touches the bottom of wire with the help of hog rings (14 SWG) and in between Y shaped angle iron post complete all as specified and directed. NOTE: (i) Hogging shall be fixed at a interval of 600mm centre to centre, wherever it touches with the razor wire. (ii) Overlapping of concertina coil and razor wire shall be 300mm. (iii) Y shaped angle iron post shall be measured and paid separately under respective items. MAKE: M/s Global Engg or M/s Specials steels Ltd or M/s Super Fence or other equivalent make as approved by GE.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .