Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance KHARNAKLING CHOGLAMSAR | LEH LADAKH | LADAKH | 194101 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
1 Feb 2025, 2:00 pmClosed
Executive Engineer EDD Leh
Executive Engineer PDD Choglamsar
Same as above
2025_PDNRE_15502_1
SITC fo shifting of 400KVA Substation along with HT line to the SRTC compound at the New bus Leh
Open Tender
Electrical Works
Turn-key
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹300
Payable To Executive Engineer EDD Leh
₹18,000
13 Mar 2025
25 Jan 2025
3 Feb 2025
25 Jan 2025
1 Feb 2025
27 Jan 2025
Amount
DT ( Supply Part)
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply of 9Mtr Long Pole, ST-410 SP33
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Supply of GI Channel/Angle/Flat of sizes including clamps
Supply of Galvinized Nuts and Bolts.
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
Supply of Danger Plates with Clamps
Supply of GI Barbed Wire for Anti Climbing
Supply of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Supply of Paint for Poles Red Oxide
Supply of Paint for Poles Aluminium Paint
Supply of Sundry items like aluminium lugs, Jumpers, binding Tape,
DT ( Installation ,Testing & Commissioning )
Installation ,Testing and commissioning of 400 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, ( Copper wound ) , and with LV Cable Box having detachable Aluminium Gland plate.
Installation ,Testing and commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Installation ,Testing and commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Installation ,Testing and commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Installation ,Testing and commissioning of 400 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 630 KVA DT
Installation ,Testing and commissioning of 9Mtr Long Pole, ST-410 SP33
Installation ,Testing and commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Installation ,Testing and commissioning of GI Channel/Angle/Flat of sizes including clamps
Installation ,Testing and commissioning of Galvinized Nuts and Bolts.
Installation ,Testing and commissioning of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Installation ,Testing and commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Installation ,Testing and commissioning of LT Distribution Box for 400 kVA DTR with MCCB for incommer and SFU's for outgoing circuit.
Installation ,Testing and commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
Installation ,Testing and commissioning of Danger Plates with Clamps
Installation ,Testing and commissioning of GI Barbed Wire for Anti Climbing
Installation ,Testing and commissioning of 11 KV HT metering CT & PT operated(complete set including cables etc) CT Ratio 50/5
Installation ,Testing and commissioning of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Installation ,Testing and commissioning of Painting of Poles Red Oxide
Installation ,Testing and commissioning of Painting of Poles Aluminium Paint
Installation ,Testing and commissioning of Sundry items like aluminium lugs, Jumpers, binding Tape,
Installation ,Testing and commissioning of Transformer Bedding /Platform ( ratio1:2:4 Concrete bedding size 6 x 6 x 6 ft.)
Installation ,Testing and commissioning of Transformer Fencing
11KV HT Line ( Supply Part)
Supply of 9 Mtr. Long Pole( ST-410 SP33)
Supply of GI V cross-arm with top Bracket including clamp AS per specification (14.631 kg/V-set
Supply of 50 mm² ACSR Conductor
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Supply of Galvinized Nuts and Bolts
Supply of Danger Plates with Clamps
Supply of Anti-Climbing Device with Clamps
Supply of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Supply of Red Oxide
Supply of Aluminium paints
Supply of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
11KV HT Line ( Installation ,Testing & Commissioning )
Installation ,Testing and commissioning of 9 Mtr. Long Pole( ST-410 SP33)
Installation ,Testing and commissioning of GI V cross-arm with top Bracket including clamp AS per specification (14.631 kg/V-set
Installation ,Testing and commissioning of 30 mm² ACSR Conductor
Installation ,Testing and commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Installation ,Testing and commissioning of Galvinized Nuts and Bolts
Installation ,Testing and commissioning of Danger Plates with Clamps
Installation ,Testing and commissioning of Anti-Climbing Device with Clamps
Installation ,Testing and commissioning of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Installation ,Testing and commissioning of Red Oxide
Installation ,Testing and commissioning of Aluminium paints
Installation ,Testing and commissioning of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Dismentling of existing 400KVA Transformer along with accessories (LS) and installation of meter/LTDB and Transformer at new location
M/S TSERING DORLAK GOVT CONTRACTOR (BID ID -147424)
NAMDRUK ELECTRICALS (BID ID -147503)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .