Loading…
Loading…
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
2 Jun 2026, 1:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
Clause Regarding GST: (a) All the Bidders/tenderers should ensure that they are GST Compliant and their quoted tax Structure are as per GST LAW.(b) Tenderer Should Furnish their GSTIN numbers representing the States in Which they are registered GST, along with address of Registered Office.(c)The Contract is under GST Act and rules as applicable time to time.
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Annual Contractual Turnover Data for the Previous 3/4 Years should be submitted as per Annexure-IX.(AnnexureVIB of Tender Documents)
39 conditions · 11 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Provision of Earthing and RCCB in Electrical Installation & APFC Panels in Identified Load Centres.
LV-T-14-TSK-924-R-1
LV-T-14-TSK-924-R-1
Open
Works - General
12 Months
Tinsukia, Assam
₹0
₹2.8 L
2 Jun 2026
12 May 2026
19 May 2026
19 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,40,68,185 | ||
| — | 670.00 | — | — | ||
| Erection of earth by 50 mm dia 3 Mtrs. long (3.6 mm thickness) GI pipe , 6 SWG GI wire,GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with RCC cover slab 12.7 mm thickness and watering pipe per Drawing No PCEE/ELG/DRG/2024/1 Dtd 30.09.2024 | — | — | — | 29,17,180 | |
| — | 200.00 | — | — | ||
| Erection of earth by 50 mm dia 3 Mtrs. long (3.6 mm thickness) GI pipe ,32x6 mm GI strip- 5 Mtrs ,GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with RCC cover slab 12.7 mm thickness and watering pipe per Drawing No PCEE/ELG/DRG/2024/1 Dtd 30.09.2024 | — | — | — | 10,53,600 | |
| — | 300.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of wall mounted 8 way MCB SPN DB Double Door having IP 63 protection, Shrouded Neutral Bar & Bus Bar, Cement Spill Protector & Door Earthing with the following domestic switchgears :- (i) RCCB 32 Amps DP ,100 mA Sensitivity, In accordance with IS 12640-1 & IEC 61008-1) 240 V/415 V, 50 Hz with 10 kA short circuit withstand capacity =2 No. (ii) 32 Amps DP MCB "C" Series(2 Module), 240/415 V, 50 Hz, 10 kA BC (In accordance with IS/IEC 60898-1) =2 No | — | — | — | 31,59,300 | |
| — | 8500.00 | — | — | ||
| Supply, drawing and connection of single core 4 sq. mm PVC insulated & unsheathed multistrand FRLHS copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site. | — | — | — | 4,84,500 | |
| — | 4.00 | — | — | ||
| "Supply, installation of Automatic Power Factor Correction panel 100KVAR . Automatic Power Factor Correction panel shall be totally enclosed, metal clad, sheet steel fabricated, dust and vermin-proof, free standing, floor mounting type. one portion of the cubical enclosure will be for mounting protection MCCBs and switching contactor and the other portion is for mounting capacitors and reactors. Horizontal Bus Bar would be Copper having current density 1.4/Sqmm. The enclosure shall be powder coated and IP Rating: IP 42.(3 CT sensing for Microprocessor based APFC Relay.) The APFC Panel will come with the Following Switchgears: (i)Capacitor Bank of 100KVAR,3 Phase Delta Connctted. (ii)Power Contactor: AC6 b duty 3 pole air-break, magnetic, capacitor duty type. (iii)APFC Relay: Microprocessor based APFC Relay. (iv)Incomer: 3 Pole MCCB of rated capacity. (Ics=100% ICu)" Technical Specifications Attached. | — | — | — | 13,21,600 | |
| — | 4.00 | — | — | ||
| "Supply, installation of Automatic Power Factor Correction panel 200 KVAR . Automatic Power Factor Correction panel shall be totally enclosed, metal clad, sheet steel fabricated, dust and vermin-proof, free standing, floor mounting type. one portion of the cubical enclosure will be for mounting protection MCCBs and switching contactor and the other portion is for mounting capacitors and reactors. Horizontal Bus Bar would be Copper having current density 1.4/Sqmm. The enclosure shall be powder coated IP Rating: IP 42.(3 CT sensing for Microprocessor based APFC Relay.) The APFC Panel will come with the Following Switchgears: (i)Capacitor Bank of 200 KVAR,3 Phase Delta Connctted. (ii)Power Contactor: AC6 b duty 3 pole air-break, magnetic, capacitor duty type. (iii)APFC Relay: Microprocessor based APFC Relay. (iv)Incomer: 3 Pole MCCB of rated capacity(Ics=100% ICu)"Technical Specifications Attached. | — | — | — | 22,27,840 | |
| — | 3.00 | — | — | ||
| "Supply, installation of Automatic Power Factor Correction panel 250 KVAR . Automatic Power Factor Correction panel shall be totally enclosed, metal clad, sheet steel fabricated, dust and vermin-proof, free standing, floor mounting type. one portion of the cubical enclosure will be for mounting protection MCCBs and switching contactor and the other portion is for mounting capacitors and reactors. Horizontal Bus Bar would be Copper having current density 1.4/Sqmm. The enclosure shall be powder coated IP Rating: IP 42.(3 CT sensing for Microprocessor based APFC Relay.) The APFC Panel will come with the Following Switchgears: (i)Capacitor Bank of 250KVAR,3 Phase Delta Connctted. (ii)Power Contactor: AC6 b duty 3 pole air-break, magnetic, capacitor duty type. (iii)APFC Relay: Microprocessor based APFC Relay. (iv)Incomer: 3 Pole MCCB of rated capacity (Ics=100% ICu)"Technical Specifications Attached. | — | — | — | 20,28,915 | |
| — | 250.00 | — | — | ||
| Supply, Laying of LT Aluminium Power Cables 150 SQ MM 4 Core, Stranded aluminium conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Unarmoured/Armoured galvanised steel strip), Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments . Cable laying to be done through wall/Surface Clamped with 25/40 x3 mm MS flat clamp as per direction of Engineer Incharge at site. | — | — | — | 4,11,250 | |
| — | 400.00 | — | — | ||
| Supply, Laying of LT Aluminium Power Cables 120 SQ MM 4 Core, Stranded aluminium conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Unarmoured/Armoured galvanised steel strip), Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments . Cable laying to be done through wall/Surface Clamped with 25/40 x3 mm MS flat clamp as per direction of Engineer Incharge at site. | — | — | — | 4,64,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocumentTSK-924-R-1.pdf
ATTACHMENT
AnexxuresSectionVIINew.pdf
ATTACHMENT
EarthingSpecs.pdf
ATTACHMENT
TechnicalSpecificationAPFCpanel.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .