Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAdmitted-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L1 | Admitted-Finance | |
| 2 | L2₹3.4 L+₹3,357.30 (1.01%)Admitted-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L2 | Admitted-Finance | |
| 3 | L3₹3.4 L+₹5,240.34 (1.57%)Admitted-Finance 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | EASTERN INDIA SALES AND SERVICE L3 | DAS ENTERPRISE L2 | WEST BENGAL ENGINEERING CO. L1 |
|---|---|---|---|---|---|---|
| 1.00Actuator starter repairing portion:- | ||||||
| 1.01 | 9 Amp, 3 Pole power contactor, 415 V AC, 50 Hz, with 1 No auxiliary contact block, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1.(Make:- L & K, Type No-MNX 9, Cat No-CS94106/Other approved make) | 2 | Nos | 1,390 ₹2,780 | 1,385 ₹2,770 | 1,370 ₹2,740 Lowest |
| 1.02 | 2 NO+ 2 NC auxiliary add on contact block for 240 V AC control voltage.(Make:-L & K, Type No-MCX 01-22, Cat No-CS91107/Other approved make) | 2 | Nos | 1,940 ₹3,880 | 1,930 ₹3,860 | 1,909 ₹3,818 Lowest |
| 1.03 | Thermal overload relay range from 3-5 Amp, ambient temperature compensated up to 55° C, built-in single phasing protection, manual and auto reset mode, conforms IS/IEC 60947-4-1 & IEC 60947-4-1.(Make:-L & K, Type No-MN2, Cat No-SS94141OOSO) | 1 | No | 2,405 ₹2,405 | 2,395 ₹2,395 | 2,369 ₹2,369 Lowest |
| 1.04 | Kit for Mounting MN-2 Relay separately (Direct Mounting Type)(Make:- L & K, Cat No-SS94700OOOO) | 1 | No | 335 ₹335 | 330 ₹330 | 323 ₹323 Lowest |
| 1.05 | Ø22.5 mm LED indicaor operating voltage-240 VAC, low power consumption < 1W, surge & low voltage glow protection (LVGP).(Make:-L & K, Cat No-EPL) | 1 | No | 160 ₹160 | 155 ₹155 | 151 ₹151 Lowest |
| 1.06 | 1.5 Sqmm PVC insulated(Un-sheathed) FR-LSH Cu wire single core multi strand 1.1 KV grade as per IS:694.(Make:-Polycab/Gloster/Other approved make)(For Control Circuit) | 27 | Mtrs | 34 ₹918 | 33 ₹891 | 32 ₹864 Lowest |
| 1.07 | 2.5 Sqmm PVC insulated(Un-sheathed) FR-LSH Cu wire single core multi strand 1.1 KV grade as per IS:694.(Make:-Polycab/Gloster/Other approved make)(For Control Circuit) | 13 | Mtrs | 55 ₹715 | 54 ₹702 | 53 ₹689 Lowest |
| 1.08 | Pin/ring type socket, lugs, PVC chanels, etc. | 1 | Item | 900 ₹900 | 890 ₹890 | 880 ₹880 Lowest |
| 1.09 | Atfirst disconnection of all power line.Then fixing the above supplied materials at same place, then making power & control circuit wiring through out the local push button/starter work must be done by Experienced electrician and wholly satisfaction of EIC. | 1 | Item | 1,250 ₹1,250 | 1,200 ₹1,200 | 1,183 ₹1,183 Lowest |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
31 Aug 2026, 4:00 pmClosed
Executive Engineer,AMD P.H.E dte
Office of the Executive Engineer,Asansol Mechanical Division,Public Health Engineering Directorate,SEN-RALEIGH ROAD,713305
Repairing of No-4 actuator starter, actuator operated butterfly valve for delivery side of centrifugal pump no-1 and 3, replacement of damaged UPS for level indicator at Amdohi Boosting Station under Jamgara-Jagannathpur W/S scheme.
2026_PHED_1037874_3
WBPHED/EE/AMD/ NIeT-24 of 2026-2027
Open Tender
Miscellaneous Works
Item Wise
15 days
Amdohi
Please refer Tender documents.
4 documents required · 4 mandatory
₹7,000
8 Oct 2026
13 Aug 2026
2 Sept 2026
13 Aug 2026
31 Aug 2026
13 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Actuator starter repairing portion:- | |||||
| 1.01 | 9 Amp, 3 Pole power contactor, 415 V AC, 50 Hz, with 1 No auxiliary contact block, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1.(Make:- L & K, Type No-MNX 9, Cat No-CS94106/Other approved make) | 2 | Nos | 3 | ₹6 |
| 1.02 | 2 NO+ 2 NC auxiliary add on contact block for 240 V AC control voltage.(Make:-L & K, Type No-MCX 01-22, Cat No-CS91107/Other approved make) | 2 | Nos | 3 | ₹6 |
| 1.03 | Thermal overload relay range from 3-5 Amp, ambient temperature compensated up to 55° C, built-in single phasing protection, manual and auto reset mode, conforms IS/IEC 60947-4-1 & IEC 60947-4-1.(Make:-L & K, Type No-MN2, Cat No-SS94141OOSO) | 1 | No | 4 | ₹4 |
| 1.04 | Kit for Mounting MN-2 Relay separately (Direct Mounting Type)(Make:- L & K, Cat No-SS94700OOOO) | 1 | No | 5 | ₹5 |
| 1.05 | Ø22.5 mm LED indicaor operating voltage-240 VAC, low power consumption < 1W, surge & low voltage glow protection (LVGP).(Make:-L & K, Cat No-EPL) | 1 | No | 6 | ₹6 |
| 1.06 | 1.5 Sqmm PVC insulated(Un-sheathed) FR-LSH Cu wire single core multi strand 1.1 KV grade as per IS:694.(Make:-Polycab/Gloster/Other approved make)(For Control Circuit) | 27 | Mtrs | 7 | ₹189 |
| 1.07 | 2.5 Sqmm PVC insulated(Un-sheathed) FR-LSH Cu wire single core multi strand 1.1 KV grade as per IS:694.(Make:-Polycab/Gloster/Other approved make)(For Control Circuit) | 13 | Mtrs | 8 | ₹104 |
| 1.08 | Pin/ring type socket, lugs, PVC chanels, etc. | 1 | Item | 6 | ₹6 |
| 1.09 | Atfirst disconnection of all power line.Then fixing the above supplied materials at same place, then making power & control circuit wiring through out the local push button/starter work must be done by Experienced electrician and wholly satisfaction of EIC. | 1 | Item | 10 | ₹10 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
Tendernotice_2.pdf
PDF • 0.53 MB
Tendernotice_3.pdf
PDF • 0.38 MB
BOQ_2549639.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .