| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | ₹45.4 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹59.9 L+₹14.5 L (31.9%)Rejected-Finance AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | ₹59.9 L+₹14.5 L (31.9%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹60.8 L+₹15.4 L (33.9%)Rejected-Finance | ₹60.8 L+₹15.4 L (33.9%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹64.4 L+₹19.0 L (41.7%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | ₹64.4 L+₹19.0 L (41.7%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹64.6 L+₹19.2 L (42.2%)Rejected-Finance | ₹64.6 L+₹19.2 L (42.2%) | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
7 Jun 2024, 6:00 pmClosed
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
REPAIR MAINT OF HT CABLE, CONDUCTORS, TRANSFORMERS, HT VCB PANEL, HT POLE, GOD SWITCH AND RELATED ACCESSORIES INSTALLED AT SECTOR C AND D UNDER AGE E/M-I OF GE 865 EWS AT LEH
2024_MES_652075_1
138WE/L-13/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE 865 EWS
₹1.4 L
Yes
10 Jul 2024
3 May 2024
14 Jun 2024
3 May 2024
7 Jun 2024
24 May 2024
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 3.0 m in depth and getting it out for pole erection in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for crushed stone sand cushioning to UG cable, provide with the layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable complete all as specified and directed by Engr-in-Charge. Note :- Punned thickness of 18 cm shall be measured and Paid.
Supplying and laying unreinforced precast concrete cable cover, class HV, type 1 flat of size 300mm x180mm x 40mm placed perpendicular to the cable complete all as specified and directed by Engr-in-Charge.
Supply and fix GI Pipe Light grade with all connected accessories of size 100 mm dia complete all as specified and directed by Engr-in-Charge.
Cutting of existing road not exc 1.5 mtr in depth and not exceeding 1.5 mtr wide including black top, sub base and WBM, well ramming in layers with watering after laying of RCC /GI pipe under road making good in all respect to match with the existing surface all as directed by E-in-charge.
Supplying laying & testing of XLPE cable insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, earthed system of size 3 core 95 sq mm complete all as specified and directed by Engr-in-Charge.
S&F in repairs cable end joint boxes 95 Sqmm, 3 core XLPE 11kV HT Cable heat shrinkable indoor / outdoor type, complete all as specified and directed by Engr-in-Charge.
S&F in repairs cable straight through joint 95 Sqmm, 3 core XLPE 11KV HT Cable heat shrinkable complete including necessary excavation and earth work complete all as specified and directed by Engr-in-Charge.
S&F in replacement indicating lamps from cubical panel complete all as specified and directed by Engr-in-Charge.
M&L for replacement of voltmeter 0 to 500 Volts complete all as specified and directed by Engr-in-Charge.
M&L fo replacement of Ammeter 0 to 500 Amps 135mmx135mm, complete all as specified and directed by Engr-in-Charge.
M&L fo replacement of Ammeter 0 to 250 Amps 135mmx135mm, complete all as specified and directed by Engr-in-Charge.
M&L for filtration of transformer oil to remove moisture, sludge, carbon particles and to achieve dielectric strength/rupturing capacity of oil and topping up of oil to the required level of the transformer indicator level complete all as specified and directed by Engr-in-Charge. Note: (a) Oil topping up shall be measured and paid separately. (b) Filtration shall be done at site and on line. (c) BDV test shall be carried out before the filtration and after the filtration & results recorded in triplicate duly signed by the contractor, MES rep. and Engr-in-charge . (d) Dielectric strength of the oil shall not be less than 50 kV after filtration & the rate quoted for the items shall be deemed to include the filtration till the desired dielectric strength is achieved complete all as specified and directed by Engineer in Charge
Supply and Fill new transformer oil topping up / change complete superior quality having di - electric strength not less than 60 KV and ISI marked of approved make complete all as specified and directed by Engr-in-Charge. Note: (a) The transformer oil shall be ISI marked, and brought at site in sealed container only. (b) Cost of collection of samples before and after topping up/changing including testing for dielectric strength etc complete included in the rate quoted for this item
Disconnecting the transformer of capacity 100 KVA to 250 KVA any type situated at various locations 11/ 0.433 KV of any make and transporting to workshop for repairs/ rewinding. Dismantling the transformer and accessories, draining out insulating oil, taking out the core assembly, defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enamelled wire / copper strip of exsisting size, providing new insulation, sleeves for outlet connections, ovening the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning. The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop. Notes (i) Copper winding wire/strip will be measured and paid separately. (ii) Transformer oil for topping up will be measured and paid separately. (iii) Transportation of transformer for repair and re-installation is deemed to include in quoted rates complete all as specified and directed by Engineer in Charge
All as per item No 18 above but of capacity 320 KVA to 500 KVA
Removel of burnt HT coil winding and replacement of the same with new super enamelled copper wire coil of same gauge and turns including necessary insulation materials like impregnated paper or super enamelled of transformers of capacity 100 KVA to 250 KVA complete all as specified and directed by Engineer in Charge
Removal of burnt LT coil winding and replacement of the same with super enamelled copper coil of same gauge and turns including necessary insulation materials of transformers of capacity 150 KVA to 500 KVA complete all as specified and directed by Engineer in Charge
Supply and fixing of gang operated air break switches HT 11KV grade outdoor type, triple pole of capacity 200 amps rating mounted on polymer based 09 insulators fitted on steel frame horizontally, mechanically operated mechanism from ground level including GI pipe handle clamps bolts, nuts, jumper wire connecting with stranded conductors complete with locking arrangements complete for current rating 200 Amp all as specified and directed by Engr-in-Charge..
Supply and fix in replacement of drop out fuse unit expulsion type for outdoor air break gang operated switch, single pole, mounted on polymer based insulators for 11 KV working pressure, fixed to and including MS channel with nuts, bolts, washers etc, synthetic bounded fuse carrying tube complete with line taps and suitable for current carrying capacity upto 25-50Amps and connected with suitable size of ACSR conductor as jumper between GOD and DO fuse, with 11 KV HT PVC sleeve, with all fittings/accessories for current rating 200 Amps ,including taking down of only 3 fuses complete all as specified and as directed by Engr-in-charge.
Supply, fixing and connecting HT 11 KV outdoor expulsion type lightning arrestors with mounting accessories complete fixed on cross arms of 2 pole structur and connected with same size of ACSR conductor as O/H HT conductor with 11 KV KT empire tape insulation with all fittings, transmission class, having discharged capacity of 65 kilo amps and suitable for working pressure of HT 11 KV complete all as specified and directed by Engr-in-Charge
S&F in repair disc insulator porcelain vitreous brown 145mm high and 255mm dia ball and socket type single disc assembly for tension with tension clampstor conductors working pressure 11000 volts complete all as specified and directed by Engr-in-Charge.
S&F in repair pin/post type polymer based insulator 150mm height and 150mm dia suitable for 11 KV grade insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut,complete all as specified and directed by Engr-in-charge.
M&L for stay assembly complete with 30x30x6mm thick plate and 20mm dia stay rod and stay insulators all as shown in electrical plate No. 1 including necessary excavation, earthwork stay bow, stay wire and PCC complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of L Frame: Adjustable Thermal* & Fixed Magnetic setting MCCB 630 Amps, 50 KA, 415 Volts four pole complete all as specified and directed by Engr-in-Charge.
S&F for aluminium strip of size 32mm x 10mm thick with necessary clamps, bolts nuts and washers of suitable size, mounted on polymer based 11 KV insulators with jumpers including removal of unserviceable one complete all as specified and directed
Supply and erecting in true vertical position steel tubular swaged poles complete with cast iron base plate, final taper plug bolts, nuts and screws as specified type 410 SP-55(11.0 meters long) complete all as specified and directed by Engr-in-Charge
M&L for cement concrete(1:4:8) type D2 in foundation filing and mass concrete using 40 mm graded stone aggregate for pole/stay foundation etc complete all as specified and directed by Engr-in-Charge
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40 mm graded stone agg for pole/stay foundation etc complete all as specified and directed by Engr-in-Charge
Materials and labour for cross arms, bracings supports clamps and back plates fabricated from structural steel section including nuts bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of two quotes of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-Charge
M&L in replacement for aluminium conductor, steel re-inforced complete all as specified and directed by Engr-in-Charge.
M&L in replacement for Galvanised steel wire 3.15 or 4.00 dia as per site requirement complete all as specified and directed as Engr-in-Charge.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm as earthing lead buried directly in groungd vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, checknuts and washers etc made of GI and connected earthing test points all as shown in electrical plate no. 5 of SSR Part-1 of 2009.00 and as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm) funnel with grade and lugs, including galvanised iron strip 32 X 6 m with GI protection pipe of 40 mm medium grade 7.5 meter long etc complete all as specified and directed by Engr-in-Charge
M&L for HT jumper with the help of Aluminium Conductor Steel Re-inforcement covered with insulating material/sleeve and including lugs at both ends at suitable at site. The length of jumper shall not be less that 2.5 meter including connection with the help of connector on the HT pole complete all as specified and directed by Engr-in-charge.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-in-charge.
Material and labour for painting to existing HT pole 11 mtr long including cross arms/angle etc. with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed by Engr-in-charge.
Material and labour for painting to existing HT 2 pole structure 11 mtr long including cross arms/angle etc. with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed by Engr-in-charge.
Material and labour for painting to existing HT 4 pole structure 11 mtr long including cross arms/angle etc. with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed by Engr-in-charge.
M&L for Fixing chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed by Engr -in-charge.
S&F in replacement PVC LT/HT line phase seperator suitable for 2/3 wire having phase to phase gap (Spacing between the conductrs) 300mm or 380mm as per requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC LT/HT line phase seperator suitable for 4/5 wire having phase to phase gap (Spacing between the conductrs) 300mm or 380mm as per requirement complete all as specified and directed by Engr-in-Charge.
Disconnecting the transformer any type from HT/ LT system and opening carefully for rectifying the leakage by replacing the unserviceable spare parts of capacity 100 to 250 kVA transformer and complete assembling after repairs including testing for any oil leakages, proper functioning and connecting the HT/ LT system complete all as specified and directed by Engr-in-Charge. Note :- Defective parts replaced will be measured and paid separately
Disconnecting the transformer any type from HT/ LT system and opening carefully for rectifying the leakage by replacing the unserviceable spare parts of capacity 315 to 630 kVA transformer and complete assembling after repairs including testing for any oil leakages, proper functioning and connecting the HT/ LT system complete all as specified and directed by Engr-in-Charge. Note :- Defective parts replaced will be measured and paid separately
Supply and fix in replacaemaent of LT bushings with brass studs complete all as specified and directed by Engr-in-Charge
Supply and fix in replacaemaent of top cover gasket set complete all as specified and directed by Engr-in-Charge
Supply and fix in repair of oil level indicator gasket set complete all as specified and directed by Engr-in-Charge
Supply and fix in repair of HT bushing with brass studs 11 KV complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformer complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement X-volt insulating mats 2.5 mm thick in roll size of 1Mtr x 10Mtr including suitable adhesive for fixing it on the floor/surface to be laid in electrical power house/sub stations, to suit IS 15652:2006 to provide earth insulation for 11 KV voltage system complete all as specified and directed by Engr-in-Charge.
Disconnecting and removing LT Cables and other connection and strip opening of Servo stablizers of up to 100 KVA 433 Volts indoor /out door type of any make after unscrewing nuts/bolts screws and connected accessories such as breather tempreture gauge for replacement of defective LT coils /replacement of drain valve paper insulation strip electronics cards of each phase (RYB) etc and other defective parts i.e servo motor , out in terminals (payment of defective replaced parts shall be measured and paid separetly reassembling after replacing the defective coils parts and replacing the top gasket sheet and other insulating packing materials and testing complete all as specified and directed by Engr in charge. Note :- The reassembling element covers the assembling of parts not to be changed where as for the rest it shall be the part of the item being replaced.
M&L for replacement of servo motor for upto 100 KVA of existing model and capacity including testing and commissioning after repair complete all as specified and directed by Engr in charge
M&L for replacement of servo electronic card upto 100 KVA of existing model and size incl testing and commissioning after repair complete all as specified and directed by Engr in charge
M&L in replacement for Incoming Off load Changeover Switch Enclosure with 630 Amp Incoming change Over switch- to accommodate all connected accessories complete all as specified and directed by Engr-in-Chage.
Labour charges for servicing / Repairing & testing of all protection relays , CTs,PTs of 11KV 630 / 800 A of any make indoor VCB panels,complete all as specified and directed by Engr-in-Charge.
Taking out defective / wornout parts from item No 57 at the time of repairing and Supply & fixing new, in replacement (if required) for the following ,complete all as specified and directed by Engr-in-Charge. (i) Closing coil
All as per ser item No 57 above but Tripping coil.
All as per ser item No 57 above but Spring charging motor assambly
All as per ser item No 57 above but PT Fuse
All as per ser item No 57 above but Motor cut off switch'
All as per ser item No 57 above but Breaker control switch.
All as per ser item No 57 above but Roller.
Taking out defective ammeter from 11 KV VCB Panels and S&F of 3 phase digital ammeter ,complete all as specified and directed by Engr-in-Charge.
Taking out defective multifuction meter from 11 KV VCB Panels and supply and fix digital multi functional meter, ,complete all as specified and directed by Engr-in-Charge.
Taking out defective multifuctional protection relay from 11 KV VCB Panels and supply and fix of REF 615 digital multi functional protecton relay with consits overcurrent, dir earth fault, combined protection, In sync for close, Frequency protection, beaker failure, Disturd rec triggered, CB conditon moniterring and supervsion of all data, complete all as specified and directed by Engr-in-Charge.
Taking down defective indication lamps and replace with new LED pilot lamps complete for VCBs,complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC LT/HT line phase seperator suitable for 1/2 wire having phase to phase gap (spacing between the conductrs) 300mm or 380mm as per requirement complete all as specified and directed by Engr-in-Charge.
M/S NANCY ENTERPRISES
darshan kumar gandhi
SUMEET TRADING CORPORATION
M/S SHEYSHAN ENTERPRISES
R B TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .