Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
24 Nov 2021, 11:00 amClosed
Shri Vijendra Arya, AGE (I)
AGE (I) Manauri Prayagraj-212212
REPAIR/ MAINT OF INTERNAL ELECTRIFICATION WITH OTHER ALLIED WORKS IN ESSENTIAL BLDGS AND EM INSTALLATION AT AF STATION MANAURI
2021_MES_483481_1
8934/E8
Open Tender
Electrical and Maintenance Works
Item Rate
182 days
Manauri
As per tender documents
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹19,600
Yes
20 Dec 2021
23 Oct 2021
25 Nov 2021
23 Oct 2021
24 Nov 2021
11 Nov 2021
Amount
Taking down carefully point wiring (light, fan, socket or power) complete with fitting such as switches, ceiling roses, lamp holder, sockets, fan regulators, Sketch light fittings wooden terminal box plastic laminated sheet cover from TW battens including TW batten or drawing from existing conduit non-metallic removing including TW batten all as specified and as directed by Engr-in-Charge
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS PVC cable IS:694 with multi stranded copper conductor of size 1.5 sqmm (Nominal area) drawn through and including rigid PVC conduit/ metelic conduit ISI marked not less than 20 mm dia with all PVC conduit fittings such as Tees, elbows, bend, reducers etc, concealed conduit wiring fixed on wall/ on ceiling with GI saddles, GI screws, rowel plugs (surface conduit wiring) with all fittings including tee, junction boxes and provision of pressed steel terminal box 1.25 mm thick of suitable size with 3 mm thick plastic laminated sheet cover for mounting modular / piano accessories such as switch sockets and regulators and drawn continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) connected to earth dolly complete all as specified and as directed by Engr-in-Charge for the followings:- Note :- (i) The cost of chases cutting on wall for concealing conduit, boxes, plate etc are included in the unit quoted rate. (ii) Switches, sockets, etc shall be measured and paid for separately.
(a) one light/fan/bell point controlled by one switch
(b) one 3 pin 5 amps socket out let on same board controlled by one switch
(c) one 3 pin 6 amps socket outlet on independent board controlled by one switch
(d) All as per item No 2 above but for one power point 3 pin 16 amps socket outlet on independent board with FRLS PVC insulated unsheathed 1100 volt grade cable with multi stranded copper conductor of size 2.5 sqmm (Nominal area) including provision of earth wire FRLS PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 sqmm (Nominal area) cable common connected to earth dolly all as specified for one 3 pin 16 amps socket outlet controlled by one switch complete all as specified and as directed by Engr-in-Charge.
(d) All as per item No 2 above but for one power point 5 pin 6/16 amps socket outlet on independent board with FRLS PVC insulated unsheathed 1100 volt grade cable with multi stranded copper conductor of size 4 sqmm (Nominal area) including provision of earth wire FRLS PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 sqmm (Nominal area) cable common connected to earth dolly all as specified for one 5 pin 6/16 amps socket outlet controlled by one switch complete all as specified and as directed by Engr-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) , laid/drawn through & including suitable size PVC casing capping with necessary fittings/ accessories fixed on walls/ ceiling by means of metalic sleeve/dash fastener with cadmium plated iron screws all as per ISI including sunk type pressed steel terminal boxes for mounting, fittings like switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet top covers concealed in walls etc and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) connected to earth dolly complete all as specified and as directed by Engr-in-Charge for the followings:-.
(a) one light point or one fan point controlled by one switch
(b) one 3 pin 5 amps socket out let same board controlled by one switch
(c) one 3 pin 6 amps socket outlet on independent board controlled by one switch
S&F of switch piano flush type 5/6 Amps single pole one way 230/250 volts complete for one light/fan point/ 5 amp socket outlet controlled by one switch all as specified and directed by Engr-in-Charge
S&F socket outlet 5 pin, 5/6 amps flush type complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type single pole one way 16 amps complete all as specified and directed by Engr-in-charge.
S&F socket outlet 2 in 1 combination, 5 pin 6/16 amps flush type complete all as specified and directed by Engr-in-Charge
S&F Ceiling rose, surface bakelite, 60 x 50 mm, three terminals.
S&F Stepped type electronic fan regulator make flush type and connecting up. Regulator shall be of Cat part No 14502 of Anchor / Cat part No 675530 of Legrand or equivalent model of make specified in appendix 'B' to particular specifications.
Supply and fixing bell ding dong type AC 230 volts single pole
Supply and fixing modular switch, flush, one way 6 Amps, single pole, 1 module including taking down old ones.
Supply and fixing modular switch, flush, one way 16 Amps, single pole, 1 module including taking down old ones.
Supply and fixing modular bell push 6 Amps 1 module including taking down old ones.
Supply and fixing modular socket 6 A, 2/3 pin combined 2 module including taking down old ones.
Supply and fixing modular socket 16 A, 3/5 pin combined 2 module including taking down old ones.
Supply and fixing modular type power unit single phase 220 volts 32 Amps socket and control switch ISI marked 4 module complete including taking down old ones.
Supply and fixing modular fan regulator step type 120W 2 module including taking down old ones.
Supply and fixing telephone sockets 2 pin modular type including taking down old ones.
Supply and fixing TV plug socket 2 pin modular type including taking down old ones.
Supply and fixing white cover plate with frame 2 module including taking down old ones.
Supply and fixing white cover plate with frame 3 module including taking down old ones.
Supply and fixing white cover plate with frame 4 module including taking down old ones.
Supply and fixing white cover plate with frame 6 module including taking down old ones.
Supply and fixing white cover plate with frame 8 module including taking down old ones.
S&F in replacement of Factory made sheet metal enclosure distribution board SPN 8 way type double door 200 amp rates bus bar concealed in wall including PCC work with all connection and making good the disturbed surfaces of wall, matching with existing wall complete all as specified and directed by Engr-in-Charge.
S&F MCB, Single pole and neutral, 230 volt, 63 Amp rating 10KA, C series fixed in DBs catered herein before.
S&F MCB, Single pole and neutral, 230 volt, 40 Amp rating 10KA, C series fixed in DBs catered herein before.
S&F MCB, SP, 230 volts, 6 to 32 Amp rating, 10 KA, C series fixed in DBs catered herein before.
M&L in replacement of unserviceable sub main wiring with two single core FRLS PVC insulated unsheathed stranded copper conductor cable confirmimg to IS-694 with copper conductor of size 6 sqmm and drawing through non rigid metallic PVC conduit (concealed in wall) incl 6.0 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth conductor connected to earth and earth dolly in conduit including connecting to main board including non metallic PVC conduit medium grade not less than of 25 mm dia size with all accessories as specified and directed by Engr-in-Charge. Note : Two single core copper conductor of 6 sqmm including earth wire of 6.0 sqmm including PVC conduit will be measured as single unit length
M&L in replacement of unserviceable sub main wiring with two single core FRLS PVC insulated unsheathed stranded copper conductor cable confirmimg to IS-694 with copper conductor of size 4 sqmm and drawing through non rigid metallic PVC conduit (concealed in wall) incl 4.0 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth conductor connected to earth and earth dolly in conduit including connecting to main board including non metallic PVC conduit medium grade not less than of 25 mm dia size with all accessories as specified and directed by Engr-in-Charge. Note : Two single core copper conductor of 4 sqmm including earth wire of 4.0 sqmm including PVC conduit will be measured as single unit length
S&F LED surface mounted round LED lownlight fitting 18W with Al die-cast, body, finish with drop down PC diffiuser to deliver low glare illumination with optimized heat sink including making connection with three core twisted flexible copper conductor cable of suitable size & length complete including taking down to old light fitting all as specified and directed by Engineer-in-Charge. Note:-Fittings shall be of Make Crompton cat part No BGSLO SLEEK surface 18W WH RD or equivalent cat part No in make Bajaj/ Philips/Wipro/ Crompton/ Havells/ Syska. Light fitting of other make of higher capacity may be used without any price adjustment.
Supply and fixing LED tube light fitting with frame, driver etc in minimum 20 W 4 feet long white colour mounting on tow Nos of PVC round/ square block on surface of wall / beam etc incl making all electric connection using three core copper cable drawn through in PVC flexible conduit pipe from ceiling rose to fittings complete including taking down to old light fitting in all specification with connecting accessories as directed. Note:-Fittings shall be of Make Syska cat Part No-SSK-ALB-20W or equivalent cat part No in make Bajaj/ Philips/Wipro/ Crompton/ Havells. Light fitting of other make of higher capacity may be used without any price adjustment.
Supply and fixing LED tube light fitting with frame, driver etc in 10 W 2 feet long white colour mounting on tow Nos of PVC round/ square block on surface of wall / beam etc incl making all electric connection using three core copper cable drawn through in PVC flexible conduit pipe from ceiling rose to fittings complete including taking down to old light fitting in all specification with connecting accessories as directed. Note:-Fittings shall be of Make Syska cat Part No-SSK-ALB-10W or equivalent cat part No in make Bajaj/ Philips/Wipro/ Crompton/ Havells. Light fitting of other make of higher capacity may be used without any price adjustment.
S&F in replacement LED bulb 12 watt complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement sheet metal enclosure distribution board TPN, 4 poles ,double door, 4 way with 200 Amps rated copper bus bar vertical type with MCCB 4 pole 100 Amps 25KA 415 volt thermal magnetic base operated as incomer including concealed in surface of wall and making all connection using gland , thimbles in required size complete all as specified and directed. Make :- Legrand/ Seimens/ L&T Note:-Quoted rate shall be included cost of MCCB , cutting plastering , coloring to surface of wall to be concealed etc all site required matching with existing surface.
Supply and fixing in replacement single pole and neutral 4 way double door type with 200 Amp rated bus bar sheet metal enclosure distribution board complete.
S&F in replacement MCCB, 4 pole, 63 Amp rating having breaking capacity of 16 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified aid directed. Make: Legrand or equivalent in makes as specified in list of make Appendix 'B' to particular specifications.
Supply and fixing angular base plate type PVC holder with minimum 09W LED bulk head light fittings incl making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings complete including taking down to old light fitting in all specification with connecting accessories as directed. Note:- (i) Make:-Syska cat No SSK-BH-9W or equivalent model of make as specified in list of makes Appendix ‘B’ to Particular specifications. (ii) Light fitting of other make of higher capacity may be used without any price adjustment.
M & L for earthing complete with galvanized steel earth plate electrode of size 60 CM x 60 CM x 6 MM thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below the ground level) with top edge of earth plate not less than 1.50 Mtrs below normal ground level connected to galvanized earth lead strip 32 x 6 MM size by means of nut, bolts & check nuts and washers of galvanized iron or steel connected to earthing test point complete all as specified or indicated, including earthing pit with PCC 1:3:6 type C 1 using 20 mm graded stone aggregate & RCC cover slab 40 MM thick as in RCC 1:2:4 type B-1 using 20 MM graded stone aggregate, reinforced with 8 MM dia TMT bars @ 150 MM centre to centre both way with two Nos lifting handle, GI pipe 20 MM dia 'light grade' with funnel and wire mesh for watering and 40 MM dia 'light grade' GI pipe for GI earth strip 32 x 6 MM protection etc complete all as shown in electrical plate No. 3 of SSR Part - I (2009) including testing on completion including dismantling of old existing earthing complete all as specified and directed. Note:- Items includes cost of 7.5 metre galvanized earth lead strip 32 x 6 MM.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit / pipes or fixed to pole or any other indicated situation for loop earthing etc for galvanised earth strip 32x6mm (beyond 7.5 metre against Srl No 35) complete all as specified and directed.
Supply only Self adhesive PVC insulation tape suitable for 11 KV, 25.1 MMx 9.1Mx 0.305mm for HT. Scotch-70
Supply only Scotch Rubber mastic tape 2228, 2" (50mm minimum) width and 10 feet in length suitable for 11 KV. Make: 3M
S&F in replacement of flood light fitting LED 120 W with mounting bracket not, bolt, washers to be fix on pole/ wall etc all as site making all connection using three core flexible copper cable drawn through in flexible conduit pipe from control box to light fittings complete all as directed. Make:- Bajaj (AMAZE) cat No BJFL 120 W LED 1 WW (warm white) or equivalent cat part No in make Philips/Wipro/ Crompton/ Havells/Syska. Light fitting of other make of higher capacity may be used without any price adjustment.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri
M/s M A Traders
M/S Garg Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .