| 1 | L1₹60.8 LAccepted-AOC A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹65.2 L+₹1.9 L (3.01%)Rejected-Finance | L2 | Rejected-Finance Other than being Lowest | |
| 3 | L3₹71.8 L+₹8.5 L (13.4%)Rejected-Finance ROOM NO D 290 PART III GALI NO 8 SHREE GANESH MURTHI NAGAR CUFFE PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Other than being Lowest | |
| 4 | L4₹77.0 L+₹13.7 L (21.6%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-Finance Other than being Lowest | |
| 5 | L5₹83.1 L+₹19.8 L (31.2%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L5 | Rejected-Finance Other than being Lowest |
Tender Value
₹90 L
EMD Value
₹1.6 L
Closing Date
5 Jan 2022, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR REPLACEMENT OF DETERIORATED FAULTY UNDER GROUND LT CABLES METER PANEL BOARDS MCCB MCBs INCLUDING REPAIR OF ELECTRIC METERS AND CONNECTED WORKS AT VARIOUS BLDGS OF CELL 01 and CELL 02 AT NOFRA COLABA MUMBAI
2021_MES_488869_1
8697/CWE(NW) MUMBAI/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) NOFRA
Refer NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) NOFRA
₹1.6 L
Yes
8 Feb 2022
17 Nov 2021
7 Jan 2022
17 Nov 2021
5 Jan 2022
20 Dec 2021
17 Nov 2021 - 15 Dec 2021
Amount
Taking up/out old U/S XLPE insulated screened. PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking up Old concrete cable cover from trenches/walls/ceiling/poles etc any size all as specified and directed
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, laying of UG Electric cable / staying of steel tubular pole etc. and getting out in soft and loose soil/ hard soil, complete all as specified and as directed .
Material and labour for Cutting existing road surface or hard standing 0.30 mtr depth using latest technology for laying of pipes/ cables and making good distrubed surface to match with existing complete with PCC all as specifed and directed by Engineer - in - Charge
Removing the excavated material/ soil not exc 50m out of MD land complete all as specified and directed .
Returning & filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm as in soil complete all as specified & directed .
Laying Only High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 50mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings all as specified and directed by Engineer-in-Charge.
Laying Only High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 80mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings all as specified and directed by Engineer-in-Charge.
Laying Only High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 110mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings all as specified and directed by Engineer-in-Charge.
Laying Only in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 35 Sqmm laid in trenches / through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed.
Laying Only in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 50 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed.
Laying Only in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 70 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed.
Laying Only in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 95 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed.
Laying Only in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 120 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all as specified & directed.
Laying Only in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 150 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all as specified & directed.
Laying Only in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 185 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed.
Laying Only in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 240 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed.
Laying Only in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 300 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed.
Laying Only in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 400 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed. Note for item Nos 06 to 18 :- The materials for laying will be issued under Sch 'B' item.
Material and labour for Painting with of LT panels of any size and type including one coat of primer paint all including scrapping out the old paint by scrubbing and application of primer before double coat of paint including minor repair like welding of hinges, repairing of lock and key arrangements all as specified and directed by Engineer - in - Charge.
Material and labour for servicing of LT panel including dismantling the old cable lugs by cutting the cable, meggering the cables with help of megger and detecting any faul/short circuit if any including fixing of new lugs by pealing the cable, cutting and joing the cables with the help of Cable Joint Kit of suitable size if required, servicing of MCCBs/MCBs/Bush Bar/ Checking/Replacing of Nut Bolts etc. all as specified and directed by Engineer in Charge. Note: i) The items i.e. MCCBs/MCBs, Cable Joint Kit of suitable size, Painting Job of Panel shall be measured and paid seperately under various item. ii) The Material and labour required for servicing of LT panel i.e consumables/nut bolts etc shall be deemed to be included in the item rate.
Material and labour for Locating the cable fault in UG LT cable of size ranges upto 70 Sqmm and joining the cable with the help of cable joint kits of suitable size including excavation at the location of cable fault and return filling of the excavated material after joing the cable all inclusive all as specified and directed by Engineer - in - Charge. Note: i) The rate quoted shall be deemed to included the cost of fault locator if required. ii) The rate quoted shall be deemed to be included the cost of excavation and refilling etc
Material and labour for Locating the cable fault in UG LT cable of size ranges 95 to 150 Sqmm and joining the cable with the help of cable joint kits of suitable size including excavation at the location of cable fault and return filling of the excavated material after joing the cable all inclusive all as specified and directed by Engineer - in - Charge. Note: i) The rate quoted shall be deemed to included the cost of fault locator if required. ii) The rate quoted shall be deemed to be included the cost of excavation and refilling etc
Material and labour for Locating the cable fault in UG LT cable of size ranges 240 to 300 Sqmm and joining the cable with the help of cable joint kits of suitable size including excavation at the location of cable fault and return filling of the excavated material after joing the cable all inclusive all as specified and directed by Engineer - in - Charge. Note: i) The rate quoted shall be deemed to included the cost of fault locator if required. ii) The rate quoted shall be deemed to be included the cost of excavation and refilling etc
Material and labour for Locating the cable fault in UG LT cable of size ranges 400 Sqmm and joining the cable with the help of cable joint kits of suitable size including excavation at the location of cable fault and return filling of the excavated material after joing the cable all inclusive all as specified and directed by Engineer - in - Charge. Note: i) The rate quoted shall be deemed to included the cost of fault locator if required. ii) The rate quoted shall be deemed to be included the cost of excavation and refilling etc
Material and labour for Changeover switch 630A rating with suitable panel CPRI Approved, made out of 3 mm thick CRCA Sheet, size 900x800x600 mm minimum suitable for fixing of MCCBs/Bus Bar etc, weather, vermin proof factory fabricated, with angle iron stand, outdoor type for independent mounting on floor/wall including provision for incoming and outgoing cables of any size comprising of following items including necessary PCC work for foundation, Frame work for stand and lugs, thimble etc required for fixing of panel complete all as specified and directed by Engineer in Charge. (i) Aluminum Bus Bar 1200 Amp for Phase and 800 A for Neutral - 1 Set (ii) Changeover Switch 630 Amp Rating - 01 No Make: Legrand/Havells/ABB/L & T (iii) Draw Out type ACB 630 Amp - 02 Nos (for I/C and O/G) Make: Legrand CAT Part No. 6695 42 of Model No. DMX SP - 2500 or Equivalent in L & T/ ABB/Havells
Supply and Fixing Cable Straight Joint Kit heat shrinkable type of following size complete all as specified and directed by Engineer - in - Charge. Make: 3M/Raychem or equivalent
(i) 400 Sqmm
(ii) 240 to 300 Sqmm
(iii) 150 to 185 Sqmm
(iv) 70 to 120 Sqmm
(v) Upto 50 Sqmm
Fixing Only MCCB 400A 4P, with Thermal Magnetic Protection Unit, Thermal adjustable/magnetic adjustable, breaking capacity 36 kA including addition alteration in exisiting Panels required at site, complete fittings fixtures required for fixing of MCCBs complete all as specified and directed by Engineer - in - Charge. Note :-The materials for laying will be issued under Sch 'B' itmes.
Fixing Only MCCB 320A 4P, with Thermal Magnetic Protection Unit, Thermal adjustable/magnetic adjustable, breaking capacity 36 kA including addition alteration in exisiting Panels required at site, complete fittings fixtures required for fixing of MCCBs complete all as specified and directed by Engineer - in - Charge. Note :-The materials for laying will be issued under Sch 'B' itmes.
Fixing Only MCCB 250A 4P, with Thermal Magnetic Protection Unit, Thermal adjustable/magnetic adjustable, breaking capacity 25 kA including addition alteration in exisiting Panels required at site, complete fittings fixtures required for fixing of MCCBs complete all as specified and directed by Engineer - in - Charge. Note :-The materials for laying will be issued under Sch 'B' itmes.
Fixing Only MCCB 200A 4P, with Thermal Magnetic Protection Unit, Thermal adjustable/magnetic adjustable, breaking capacity 25 kA including addition alteration in exisiting Panels required at site, complete fittings fixtures required for fixing of MCCBs complete all as specified and directed by Engineer - in - Charge. Note :-The materials for laying will be issued under Sch 'B' itmes.
Fixing Only MCCB 160A 4P, with Thermal Magnetic Protection Unit, Thermal adjustable/magnetic adjustable, breaking capacity 25 kA including addition alteration in exisiting Panels required at site, complete fittings fixtures required for fixing of MCCBs complete all as specified and directed by Engineer - in - Charge. Note :-The materials for laying will be issued under Sch 'B' itmes.
Fixing Only MCCB 100A 4P, with Thermal Magnetic Protection Unit, Thermal adjustable/magnetic adjustable, breaking capacity 25 kA including addition alteration in exisiting Panels required at site, complete fittings fixtures required for fixing of MCCBs complete all as specified and directed by Engineer - in - Charge. Note :-The materials for laying will be issued under Sch 'B' itmes.
Fixing Only MCCB 63A 4P, with Thermal Magnetic Protection Unit, Thermal adjustable/magnetic adjustable, breaking capacity 16 kA including addition alteration in exisiting Panels required at site, complete fittings fixtures required for fixing of MCCBs complete all as specified and directed by Engineer - in - Charge. Note :-The materials for laying will be issued under Sch 'B' itmes.
Supply, install, testing and commissioning of LT Panel meter cabin panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 400 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and electronic meters from old meter cabin panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmwork and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following against Sch 'B' Items. (a) MCCB, FP, 250 Amps 25 kA- 02 Nos. Make-Legrand / Schneider / L&T (b) MCB 63 Amps, 10KA, C series - 16 No . Make-Legrand / Schneider / L&T (c) Sheet metal enclosure 2 way without bus bar - 16 No, Make-Legrand / Schneider / L&T (d ) Copper Bus bar, 400 Amps Rated - R,Y,B & N (e)Digital Ammeter-01 No, Make-HPL ,SP CL-1.0/AE (f)Digital Voltmeter-01 No Make-HPL ,SP CL-1.0/AE (g) Phase indicator lamp R,Y & B (h) Making provision for fixing of digital electronic meters removed from old panel including fixing and providing vision glasses - 10 Nos. (j) Material and labour for 2 core 10 Sqmm multistranded copper conductor cable 1100V form bus bar to electronic energy meters using suitable size copper thimbles/glads. (k) Fixing of submain cable 2 core 10 Sqmm copper conductor with outgoing of energy meter all as directed.
Supply, install, testing and commissioning of meter cabin panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 300 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and electronic meters from old meter cabin panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmwork and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :- (a) MCCB, FP, 200 Amps 25 kA- 02 Nos. Make-Legrand / Schneider / L&T (b) MCB 63 Amps, 10KA, C series - 12 No . Make-Legrand / Schneider / L&T (c) Sheet metal enclosure 2 way without bus bar - 12 No, Make-Legrand / Schneider / L&T (d ) Copper Bus bar, 400 Amps Rated - R,Y,B & N (e)Digital Ammeter-01 No, Make-HPL ,SP CL-1.0/AE
(f)Digital Voltmeter-01 No Make-HPL ,SP CL-1.0/AE (g) Phase indicator lamp R,Y & B (h) Making provision for fixing of digital electronic meters removed from old panel including fixing and providing vision glasses - 10 Nos. (j) Material and labour for 2 core 10 Sqmm multistranded copper conductor cable 1100V form bus bar to electronic energy meters using suitable size copper thimbles/glads. (k) Fixing of submain cable 2 core 10 Sqmm copper conductor with outgoing of energy meter all as directed.
Material and labour for Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.5 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm with the help of bolts, nuts, check nuts and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type D2 and PCC cover 1:2:4 type B1 weatering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No.3 including connection to the earthing test point and testing on completion.
Supply, install, testing and commissioning of meter cabin panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 300 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and electronic meters from old meter cabin panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmwork and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :- (a) MCCB, FP, 200 Amps 25 kA- 02 Nos. Make-Legrand / Schneider / L&T (b) MCB 63 Amps, 10KA, C series - 10 No . Make-Legrand / Schneider / L&T (c) Sheet metal enclosure 2 way without bus bar - 10 No, Make-Legrand / Schneider / L&T (d ) Copper Bus bar, 400 Amps Rated - R,Y,B & N
(e)Digital Ammeter-01 No, Make-HPL ,SP CL-1.0/AE (f)Digital Voltmeter-01 No Make-HPL ,SP CL-1.0/AE (g) Phase indicator lamp R,Y & B (h) Making provision for fixing of digital electronic meters removed from old panel including fixing and providing vision glasses - 10 Nos. (j) Material and labour for 2 core 10 Sqmm multistranded copper conductor cable 1100V form bus bar to electronic energy meters using suitable size copper thimbles/glads. (k) Fixing of submain cable 2 core 10 Sqmm copper conductor with outgoing of energy meter all as directed.
NOEL ENGINEERS
DHARICHHAN ENTERPRISE
AGRAWAL ASSOCIATES
Shree Ayyappa Engineering
SHREE JAGDISH FURNITURE CO.
C S Sharma and Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .