Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹37.6 L+₹1.4 L (3.81%)Rejected-Finance WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L2 | Rejected-Finance Due to not lowest | |
| 3 | L3₹40.4 L+₹4.2 L (11.7%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L3 | Rejected-Finance Due to not lowest | |
| 4 | L4₹46.0 L+₹9.8 L (27.2%)Rejected-Finance | L4 | Rejected-Finance Due to not lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Jun 2022, 6:00 pmClosed
GE North Bikaner
GE North Bikaner Rajasthan 334001
REPAIR MAINTENANCE OF DG SET AND OTHER CONNECTED ITEMS REPAIR MAINT OF EXTERNAL ELECTRIC WORKS STEET LIGHTS AND LT UG CABLES AT WEST CAMP SOUTH CAMP AND DB AND MOTIGARH PUGAL RD ASCON NODES AND REPAIR MAINT OF SUMMER APPLIANCES DEEP FREEZER WATER
2022_MES_519658_2
GE (N) BKN TOKEN NO 11 /2022-2023
Open Tender
Miscellaneous Works
Item Rate
335 days
Mahajan MFFR
Class D category b i
7 documents required · 7 mandatory
₹500
GE North Bikaner
₹90,000
Yes
4 Jul 2022
12 May 2022
7 Jun 2022
12 May 2022
1 Jun 2022
19 May 2022
Amount
Desert Cooler Repair to Desert Cooler Removing of old paint complete with emery paper and cleaning with scrapper and preparation of internal surfaces & bottom of the desert coolers and apply one coats of black bituminous paint complete all as specified and as directed by Engineer-in-charge.
All as per item No. 1 here in before but applying one coats of synthetic enamel paint to external surfaces of desert coolers including steel grills, removing of wooden grass pad & refixing the same after necessary work side panel etc complete all as specified and as directed by Engineer-in-charge.
Taking down carefully old unserviceable water pumps heavy duty of capacity 1/70 HP, 230 volts 50 HZ single in lieu providing new submersible type water pump including necessary wire connection complete all as specified and as directed by Engineer-in-charge. Make;- Bajaj/CG/ Havells
Taking down carefully fan motor from existing desert coolers and in lieu providing new fan motor 1/5 to 1/6 HP 230 volts, 50 HZ, including replacement of mounting legs & nuts bolts with capacitor 4 Mfd as reqd at site complete all as specified and as directed by Engineer-in-charge. Make;- Bajaj/CG/ Havells
Taking down carefully fan motor 1/5 to 1/6 HP 230 volts, 50 HZ, from existing desert coolers of each camp at MFFR and refixing the same camp fan motor after rewinding with super enameled copper wire of existing size complete including replacement of bush/bearing, mounting legs & nuts bolts capacitor 4 Mfd as reqd at site complete all as specified and as directed by Engineer-in-charge. Make: Milan/chetak Note:- Contractor will be arranged all required T&P (winding machine) repair for desert cooler motor/sevicing i.e winding/greasing /oiling in AGE MFFR yard)
Taking down the following parts from the existing desert coolers & providing new parts in same possition as listed below- (a) Capacitor for desert cooler 4 MFD 230 volts Make: Asian/Tibcon
S&F GI sheet as per existing guage front grill including nuts bolts and washers suitable for 18/20" sweep desert coolers including necessary wire connection, regulator & on/off switch etc reqd at site, Make-Alka/kinark.
Taking down following old part of desert cooler old rusted as under and M & L out of 20 gauge GI plain sheet class-III including cost of riveting welding, nuts and bolts as required accessories for fixing etc complete (a) Bottom tank as existing size
b) Top cover as existing size
c) Side panels size- set of three
d) Wood wool pad for desert coolers (set of three)
d) Supporting jali for desert coolers (set of three)
e) Plug Top 3 pin, 5-A, 230 Volt
f) Plug Top 3 pin, 15-A, 230 Volt
g) Fan blades made of aluminium for desert cooler as per sample
h) Cable, 3 core, copper conductor size 23/0.0076 for desert cooler. Make: plaza/finolex/kalinga
i) Supply only condenser 2.5 MFD
Replacement of PVC pipe 15mm for desert cooler including all necessary 'T' joints & clamps complete all as specified and as directed by Engineer-in-charge.
b) Distributor of PVC for desert cooler with fixing bolt
c) Replacement of Elbow of PVC for desert cooler
S&F in repair tap mounting with nipple 1/2" as per sample complete all as specified and as directed by Engineer-in-charge.
S&F in repair water outlet nipple with washers and check nuts (copper/brass) complete all as specified and as directed by Engineer-in-charge.
DEEP FREEZER Taking down unserviceable compressor from deep freezer including bushes, gromments, sleeves, washers, mounting rubbers, nuts, bolts terminal cover brazing and clips from existing deep freezers of capacity 320 ltr, Make: voltas/Usha/Sidhwal/Blue star complete all as specified and as directed by Engineer-in-charge.
Supply and fixing compressor suitable for deep freezer 320 ltr make- Blue star/Gulmarg/Usha, Compressor of make: Emerson Model No. CAJ 34/KCE 444 HAG with necessary accessories including provn of new bushes, gromments, sleeves, washer, mounting rubbers, nuts and bolts, terminal covers, brazing and clips complete all as specified and as directed by Engineer-in-charge.
Supply and fixing compressor suitable for deep freezer 405 ltr make- Blue star, Compressor of make: Emerson Model No. CAJ 34/KCE 444 HAG with necessary accessories including provn of new bushes, gromments, sleeves, washer, mounting rubbers, nuts and bolts, terminal covers, brazing and clips complete all as specified and as directed by Engineer-in-charge.
Cleaning of complete deep freezer existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing deep freezer of 320 /405 ltrs capacity of make and model as per existing complete all as specified and as directed by Engineer-in-charge.
Water Cooler Taking down unserviceable compressor form deep freezer including bushes, gromments, sleeves, washers, mounting rubbers, nuts, bolts terminal cover brazing and clips from existing water coolers of Make: voltas/Usha/Sidhwal/Blue star 60/120,150/180 complete all as specified and as directed by Engineer-in-charge.
Supply and fixing new hermetically sealed unit (compressor) of following Makes and model including provision of new bushes,grommets, sleeves , washers, mounting rubers nuts boltes,terminals,covers,brasing and clips in the existing Water coolers 60/120 Ltrs Make :- Blue star /usha /voltas with necessary accessaries complete all as specified and as directed by Engineer-in-charge.
All as per item No. 28 here in before but for 150/180ltrs capacity complete all as specied and as directed by engr -in-charge.
Taking down carefully existing internal wiring of existing water coolers and in liu provision of new internal wiring of with PVC insulated copper conducter cable of size 40/ 0.0076 sq mm including replacementof main lead 03 meter long, terminals clips, thimbles, 03 pin plug top 15 amps & soldering extra complete all as specified and as directed by Engineer-in-charge. Make :- of wiring plaza/finolex
Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing water cooler complete all as specified and as directed by Engineer-in-charge.
Removing of old rusted warn out portion of sheet/angle/flat iron from base, front and top etc. of the water cooler/ air conditioner and providing new mild steel sheet, angle iron/MS flat including necessary bending, welding. reveting etc. including making provision for mounting of fan motors, compressor, and condenser complete all as specified and as directed by Engineer-in-charge.
Complete removing old faded paint from steel surfaces of water cooler by scrapers making the surface smooth including filing material and painting the surface of any description over 10 Cm in width of girth not otherwise described with one coat of red oxide primer and two coats of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge.
Taking down deffective fan motor from water coolers, dismentling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size. Make : Milan/Chetak including replacement of shaft, boshes, mounting rubbers, nuts, bolts and refixing after reassembling and testing in existing water cooler for under mentioned fan motors :- (Note : The unit rate coated shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers, insulating materials and clams) Fan motors of capacity 1/16 HP 230 Volts single phase.
a) Fan motors of capacity 1/32 HP 230 Volts single phase.
b) Fan motors of capacity 1/35 HP 230 Volts single phase.
c) fan blade made out of aluminium as per sample
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/35 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and as directed by Engineer-in-charge.
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/16 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and as directed by Engineer-in-charge.
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/10 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and as directed by Engineer-in-charge.
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/25 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and as directed by Engineer-in-charge.
S & F push cock (stainlees steel) for water cooler as per sample existing.
S & F thermostat for water cooler as per sample existing.
S & F relay with OLP suitable for water cooler existing as per sample.
S & F runing capacitor 36 MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 60/80 MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 80/100 MFD. Make : Tibcon/Sharda/ Epcos
S & F runing capacitor 100/120 MFD. Make : Tibcon/Sharda/ Epcos
S & F runing capacitor 10MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 15MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 40/60 MFD. Make : Tibcon/Sharda/Epcos
Cable, 3 core, copper conductor size 40/0.0076 for water cooler. Make: plaza /finolex/kalinga
Air Conditioner Taking down unserviceable compresor 2TR capacity from the window/split AC of any make and supply and fixing new compresor 2 Ton capacity of including bushes, grommets, sleeves, washers, mounting rubbers, nuts, bolts, terminal covers, brazing and clips from existing AC complete all as specified and as directed by Engineer-in-charge.
All as per srl Item No. 53 here-in before but for window type AC 1.5 TR capacity of any make as per existing.
Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing window/split type air conditioner of 1.5/2 TR capacities of make and model as per existing complete all as specified and as directed by Engineer-in-charge.
Taking down unserviceable fan motor of any capacity from the window type air conditioner 1.5/2 TR capacity and dismantling old and unserviceable burnt winding wire and rewinding with super enameled copper wire of existing guage and size including heat varnishes replacement of shaft, bearing and bush complete all as found unserviceable after opening complete all as specified and as directed by Engineer-in-charge.
Removing of existing window/split type AC 1.5/2 Ton capacity mounting, cleaning of evaporator and condenser with alkaline based solution, washing of AC, oiling of fan motor and refixing on mounting including provn for making opening air tight and dust proof including testing and commissioning complete all as specified and as directed by Engineer-in-charge.
S & F running capacitor 45 MFD Make : Tibcon/Sharda/Epcos
S & F running capacitor 60 MFD Make : Tibcon/Sharda/Epcos
S & F running capacitor 50 MFD Make : Tibcon/Sharda/Epcos
S & F PCB (Printed Circuit Board) of window/split type capacity 1.5/2 Ton complete all as specified and as directed by Engineer-in-charge.
Replacement of remote control of 1.5/2 Ton window/split type AC of any make/type complete all as specified and as directed by Engineer-in-charge.
Taking down carefully the following parts from the existing AC and in lieu providing new accessories/parts as per existing and complete overhoauling of AC 1.5/2 ton capacity complete all as specified and as directed by Engineer-in-charge. : -Note- Accessories/parts paid saperately under relevent items
a) PVC filters for AC (window/split)
b) Contactor for split AC
c) Starting relay for AC
Replacement of burnt out transformer and S&F new transformer of 3 or 4 KVA voltage stabilizer of any make.:'V' guard complete all as specified and as directed by Engineer-in-charge.
Taking down unserviceable indoor unit of split AC capacity 1.5 TR from existing place and supply and fix new indoor unit of split AC 1.5 TR capacity of including mounting frame with nuts, bolts in existing place complete all as specified and as directed by Engineer-in-charge. Make :- Sumsung
Taking downunserviceable Exhaust rooler of split AC capacity 2.0 TR from existing place and supply and fix new Exhaust rooler of split AC 1.5 TR capacity of including bush/bearing as per existing type complete accessories fix in existing place complete all as specified and as directed by Engineer-in-charge. Make :- Sumsung
Taking downunserviceable out door unit of split AC capacity 1.5 TR from existing place and supply and fix new indoor unit of split AC 1.5 TR capacity of including mounting frame with nuts, bolts and complete accessories fix in existing place complete all as specified and as directed by Engineer-in-charge. Make :- Sumsung
Supply and laying PVC insulated stranded aluminium conductor cable heavy duty 1100 Volts grade served with an inner sheathing of PVC tape & overall PVC sheathed 06 Sqmm 2 core nominal cross section incl remove unserviceable cable complete all as specified and as directed by Engineer-in-charge. Make - (Asian Cable Co./Finolex/Polycab)
Ceiling Fan Taking down ceiling fan for repair/servicing i.e. winding/greasing/oiling etc., 1200/1400 mm sweep, of any make and any type model, ceiing cable end with tape, dismandling the blades, removing fan and deposit the blades/motor to store for repairing/servicing complete all as specified and as directed by Engineer-in-charge. (Note:- Contractor will be taking down ceiling fan of each camp in MFFR and carrying with saftey deposit for repair/sevicing i.e winding/greasing /oiling in AGE MFFR yard and camp wise marked each fan by permnent marker and informed to JE E/M )
M&L re-winding of ceiling fan of size 1200/1400 mm sweep with super enameled copper winding wire of gauge as per existing size/No of wire conforming to IS, including varnishing the motor windings with best quality varnish, capacitor 2.5 Mfd and fixing the same place complete all as specified and as directed by Engineer-in-charge. (Note:- Contractor will be arranged all required T&P repair for ceiling fan/sevicing i.e winding/greasing /oiling in AGE MFFR yard)
S&F in replacement of ball bearing of size/No. 6201 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of ball bearing of size/No. 6202 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of ball bearing of size/No. 6203 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of brass bush suitable for ceiling fan of any make and model conforming to IS complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Shaft suitable for ceiling fan as per existing size and shape complete all as specified and as directed by Engineer-in-charge
S&F fabricated down rod made out of 15mm dia MS pipe medium duty 60cm long including nut, bolt, & washer etc and including drilling holes on top and bottom fan fixing with fan hooks and ceiling respectively as required suitable for 1200/1400 mm sweep of ceiling fan all as required at site and as directed by Engineer in charge.
S&F D clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site and as directed by Engineer in charge.
S&F PVC canopies (set of two) as required at site and as directed by Engineer in charge.
S&F condenser 2.5 MFD conforming to IS complete all as specified and as directed by Engineer-in-charge.
S & F of flexible wire of size 23/.0076 stranded copper conductor complete all as specified and directed by Engr -in-charge.
S&F in replacement stepped type electronic fan regulator flush type on existing laminated sheet as per requirement including taking down old regulator complete all as specified and as directed by Engineer-in-charge.
Taking down and dismantling of exhaust fan 250 mm/350 mm/450 mm sweep of any make and model, opening the cover, separating the rotor and startor assembly, locating the fault and maing the fan in fully serviceable condition including replacing the defected worn out screw, flexible wire size 23/0.0076, oiling/greasing the fan and re-assembling the samd and testing complete to the entire satisfaction of Engineer-in-charge.
Re-winding of exhaust fan 250 mm sweep with super enameled copper winding wire as per existing size conforming to IS including varnishing the motor windings with best quality varnish, capacitor and fixing the same place complete all as specified and as directed by Engineer-in-charge. Note:- Contractor will be arranged all required T&P repair for exhaust fan/sevicing i.e winding/greasing /oiling in AGE MFFR yard)
Ditto all as per item No. 86 here in above but of size 350 mm sweep complete all as specified and as directed by Engineer-in-charge.
Ditto all as per item No. 86 here in above but of size 450 mm sweep complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of blades suitable size for exhaust fan 250 mm duly approved by Engineer in charge complete all as specified and as directed by Engineer-in-charge.
Ditto all as per item No. 89 here in above but size of exhaust fan 350 mm sweep complete all as specified and as directed by Engineer-in-charge.
Ditto all as per item No. 89 here in above but size of exhaust fan 450 mm sweep complete all as specified and as directed by Engineer-in-charge.
Taking down unsv louver and supply and fix new louver of exhaust fan of size 300 mm complete all as specified and directed by Engr-in- charge.
Taking down unsv louver and supply and fix new louver of exhaust fan of size 450 mm complete all as specified and directed by Engr-in- charge.
Supply and fixing PVC fresh air fan (Exhaust fan) of size 250/300 mm sweep and connecting up including three core PVC insulated multi stranded copper conductor cable of size 1.5 Sqmm wire from ceiling rose/connector to fan of length not less than 1.0 meter complete all as specified and as directed by Engineer-in-charge. Make: - Usha/Bajaj/Havells
Cleaning and preparation of old surface pf ciling and exhaust fan complete of any size and spray coat painting with synthetic enameled paint complete all as specified and as directed by Enge-in-charge.
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge.
All as per Srl item No. 96 here in before but exc 1.5m and not exceeding 3.0 in depth complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by the Engineer-in-Charge.
Protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ burnt-clay bricks having compressing strength not less than 75 kg/Square cm complete all as specified and as directed by the Engineer-in-Charge.
M&L for Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations of poles above ground level including finishing to exposed concrete surfaces even and fair and provision of form work for rough finished surface complete all as specified and as directed by Engineer-in-charge.
M&L for Plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations for stays and coping complete all as specified and as directed by Engineer-in-charge.
Dismantling and taking down old damaged/broken pre-stressed concrete/steel LT electric poles of any type inclding breaking down existing pcc foundation and removing from site complete all as specified and as directed by the Engineer-in-Charge.
Taking out old U/S panel any type any description and size carefully by disconecting LT cables carefully after ensuring proper shut down incl breaking up old pcc complete all as specified and as directed by the Engineer-in-Charge.
Taking out old U/S street light or street light fittings with brackets from poles, wall etc any type and description complete all as specified and as directed by the Engineer-in-Charge.
Taking out old US/faulty PVC armoured/un-armoured LT under ground cable of size 10 Sqmm to 120 sqmm 2/3 1/2 4 core complete all as specified and as directed by the Engineer-in-Charge.
Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts LT grade of cross-sectional area 06 Sqmm 2 core laid in trenches/through pipe in road crossings/paths/drains/ducts/floors/along poles/walls/ceilings/equipments etc supplied and fixed including commissioning and testing complete all as specified and as directed by the Engineer-in-Charge. Note : (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (ii) Road/boring roads manualy cutting/floor cutting/cutting holes etc in wall required for laying fising of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same.
Ditto All as per srl item No. 108 here in above but aluminium conductor 100 Volts LT of size 10 Sqmm 2 core
Ditto All as per srl item No. 108 here in above but aluminium conductor 1100 Volts LT of size 16 Sqmm 2 core
Ditto All as per srl item No. 108 here in above but aluminium conductor 1100 Volts LT of size 25 Sqmm 4 core
Ditto All as per srl item No. 108 here in above but aluminium conductor 1100 Volts LT of size 35 Sqmm 3.5 core
Ditto All as per srl item No. 108 here in above but aluminium conductor 1100 Volts LT of size 50 Sqmm 3.5 core
Ditto All as per srl item No. 108 here in above but aluminium conductor 1100 Volts LT of size 70 Sqmm 3.5 core
Ditto All as per srl item No. 108 here in above but aluminium conductor 1100 Volts LT of size 95 Sqmm 3.5 core
Ditto All as per srl item No. 108 here in above but aluminium conductor 1100 Volts LT of size 120 Sqmm 3.5 core
Boring of holes under road, pavement, hard standing by manually without damaging of road, material & labour including pipe 80/100 mm dia suitable complete all as specified and as directed by the Engineer-in-Charge. Note; lenth of pipe to be measured and paid seperately under relavant item
Supply and fixing in replacement of LED based street lights, housing made of pressure die cast aluminium alloy with effective thermal management sturdiness. The fixture should have a minimum system efficacy of more than 80 lumen/Watt and a minimum system lumen output of not less than 3600 lumens and maximum system wattage 45 watts. The fuxture shall have a color temperature of minimum 5000k at a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, lngress protection of IP66 (lamps and gear compartment and Mechanical Impact) Resistance Rating of IK>= 05. The fixture should comply with the parameters as per IEC 60598 and IS 10322, and LED drive should apply to IEC 61000-3-2 ed 3.2. per haronics IEC 61347-2-13, 2006 in confirmation with IEC 61347-1 ed, 2.0, 2007 for electrical safety, LM 79 and LM 80 test report needs to be sumitted above parameters. The fixture driver should have an operating voltage range of 140-300V, frequency 50-60 Hz, surge protection not less than 4KV, PF>0.95 and THD<15%. The driver should have double phase protection. LED lights fitting should be suitable for ambient temperature from (-) 10 digree C to (+) 50 digree C, including street light GI bracket 40mm dia bent to shape 1200 and down 15mm Bore GI pipe with GI clamps with junction box for fixing LED light required, with suitable size clamp, nut bolts and washers as per site requirement complete all as specified as directed by Engineer-in-charge. (Note-The manufacture of LED fitting shall give Guarantee for 5 years from the date of installation and complete fixed with suitable bracket & Accessories) Make-Phillips, CG, Bajaj, Wipro, C&S and surya.
Supply and fixing in replacement for two core PVC insulated weather proof cable with aluminum conductor size 4 sqmm (nominal area), & drawing into hollow street light pole from fitting to juntion box or fitting to over head line complete all as specified and as directed by the Engineer-in-Charge.
Pre-stressed concrete poles 9 meter long, 102mm x 172 mm at top and 102 mm x 279 mm at bottom, class 10, complying with requirements of IS-1678, including painting with two coats of synthetic enamel paint (in alternate black & white/yellow strips of 30 cm height) upto 1.5 meter height from top of PCC coping and also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint incl required iron channels/clamps/GI pipe for the protection of flexible cable connecter box with bus bars, bolts & nuts complete all as specified and as directed by the Engineer-in-Charge.
S&F in replacement GI pipe light grade 50 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/Ceiling/along walls/path/drain/floors with and including all necessary clamps, nuts, bolts washers etc all fittings as required complete all as specified and as directed by the Engineer-in-Charge. (Note: - excavation, earth work and same work shall be measured and pain for separately.)
Ditto All as per srl item No 121 here in above but dia of pipe 40 mm.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre depth below normal ground level) with top edge of plate at a depth not less than 1.5 mtr below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 04 mm dia with and including bolts, nuts, check nuts and washers of galvanised iron or steel and riveted to earth plate and one end and connecting to main switch board or metallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 15 mm bore GI light grade pipe with all fittings, from top of electrode to body of equipment fixed with and including flatiron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CI cover complete all specified and shown in electrical plate No 03 of SSR Pt-I connecting earth electrode to test point with and including earthing lead including neessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed by Engineer-in-Charge. (Notes 1. The rate quoted shall be deemed to include for all the above provisions. 2. PCC chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting maner) .
Supply and laying Cable jointing kit for LT 1100 V cable for straight through end termination (Epoxy), hot shrinkable type joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm 3.5/4 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-charge.make: m seal/dension.
Ditto all as per srl item No. 124 here in above but 70 to 95 Sqmm
Ditto all as per srl item No. 124 here in above but 120 to 150 Sqmm
S&F inreplacement of change over switch 200 Amps, four pole, 415 Volt, cubical type and including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge Make-C&S, Cat part-CSSDF200B4CO or equivalent cat part in make Crompton Greaves/L&T/Siemens/Alstom.
Repair the following work to existing bus bar chamber(pillar box) outdoor cubical type factory made vermin protected dust proof, water proof made out of MS sheet 1.6 mm thick and 50 cm x50 cm x6mm thick angle iron base frame having insulated bus bar aluminum 200amps cap 3 phase with neutral bus bar including fixing in PCC bed block complete all as reqd at site and as directed by Engineer in Charge with following
a) welding of brocken/cracked joints of the feeder pillar box
b) Replacing to locking arrangement of the feeder pillar box as per sample existing.
c) Painting with one coat of synthatic enamel paint after applying one coat of red oxide as a primer complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of US Feeder pillar box outdoor cubical type factory made vermin protected dust proof with canopy, water proof made out of MS sheet 1.6 mm thick and 50 cm x50 cm x1.6mm thick angle iron base frame having insulated bus bar aluminum 200amps cap 3 phase with neutral bus bar including fixing in PCC bed block complete all as reqd at site of all four camps and DBS as directed by Engineer in Charge.
M&L for Aluminium conductor, steel reinforced (ACSR) of size 3/6x2.59 mm/make including jionting for over head line on pole including binding wire 14 SWG, jumpers line tapes etc complete all as specified and as directed by Engineer-in-charge. ( for measurement and payment purpose of ACSR the weight of winding wire shall not be considered.)
M & L for repairing of broken ACSR vessal/ squarel /ferrot/ mink conductor after proper shutdown of electric supply and jumpring / cut points changing the damaged/burned conductor, cable endes, change over MCCBs condutor broken due to wind/storm and binding with the aluminium wire etc and changing the damaged pin/disc insulators and replace the broken conductor, repairing the faults in the 11/0.44 KV outdoor/ indoor electric panels at sub stations complete all as specified and directed by engineer-in-charge.( Note :- cost of fues wire minor spares, aluminium binding wire shall be deemed included in the above quoted item.,(ii) Cost of items that is pin insulator,disc insulator etc. shall be measured and paid seprately under respective items.(iii)contrator take complaints from complaints cell(JE E/M)and rectify the same day and duely signed by the users and deposited the same.one down breakdown/coplaint by attended shall be the each job.
Supplied and fixed in repair Disc type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 145 mm height, 255 mm dia. for working pressure 11000 volts grade, complete all as specified and as directed by Engineer-in-Charge.
Supplied and fixed in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia. for working pressure 11000 volts grade, complete all as specified and as directed by Engineer-in-Charge.
Supply and laying Cable indoor / outdoor end terminals jointing kit for LV/LT 1100 V cable heat shrinkable type joint kit complete with jointing material and accessories, thimbles etc suitable for 16 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-Charge.
Ditto All as per Srl item No .137 here in above but 70 Sqmm to 120 sqmm 3.5 Core
Ditto All as per Srl item No 137 here in above but 150 Sqmm to 185 sqmm 3.5 Core
M&L for repair in replacement and fixing of Maintenance free battery capacity 80 AH, 12 Volt with proper copper wire complete all as specified and as directed by Engineer-in-charge.
M&L for repair in replacement and fixing with suitable clamp of LED solar light of capacity 15 watt complete all as specified and as directed by Engineer-in-charge.
M&L for repair in replacement charger control/circuit for solar battery 12 volt including connecting to existing wiring circuit or complete all as specified or directed by engineer in charge
M&L for repair in replacement of solar plate /Solar Cell Module of capacity 12 Volt 3.25 watt complete all as specified and as directed by Engineer-in-charge.
. S&F in replcement of MCCB 4 pole 200 Amp, adjustable type 36 KA, 415 Volt including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge. Make- havells/HPL/Legrand
. S&F in replcement of MCCB 4 pole 125 Amp, fixed type 25 KA, 415 Volt including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge. Make- havells/HPL/Legrand
. S&F in replcement of MCCB 4 pole 100 Amp, fixed type 16 KA, 415 Volt including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge. Make- havells/HPL/Legrand
. S&F in replcement of MCCB 4 pole 160 Amp, Adjustable type 16 KA, 415 Volt including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge. Make- havells/HPL/Legrand
Taking down carefully the defective street light fittings 36/45/72 Watt from the poles/walls and refixing the same on poles/walls after repair complete all as directed by Engineer in Charge.( Note: A Team of workers for emergency are avlaible inside the camp for 24 Hours) 1. T&P i.e, ladder and vehicle will provided by the contractor.
Supply and fixing in replacement Driver unit with surge protection suitable for LED street light ftg of capacity 36 to 45 watt. Make – Bajaj/Philips/Crompton Greaves
Supply and fixing in replacement Driver unit surge protection suitable for LED street light ftg of capacity 72 to 80 watt. Make – Bajaj/Philips/Crompton Greaves
a) 90 Degree LED Module 3030SMD 150-160LM/W LED with Array Lens coomplete For Watts 36 to 45 watt.
b) 91 Degree LED Module 3030SMD 150-160LM/W LED with Array Lens coomplete For Watts 72 to 90 watt.
M&L for dismantling unservicable radiator of 25 KVA DG Set to 63.5 KVA, Make : Cummins/Kiloskar/Stamford, transporting to civil workshop and repairing including replacement of new radiator core made out of aluminium tube and fins, installation, commissioning and testing on full load complete all as specified and as directed by Engineer-in-charge.
M&L for complete servicing of 25 KVADG set of any make and type to made functional replacing unserviceable spare parts, old oil filer, fuel filter , air cleaner filter element including drain out old engine oil (lubricants) and coolant including commissioning & testing on full load upto satisfaction after repair/ replacement at unserviceable parts/filter engine oil/ coolant etc. complete all as specified and directed.complete all as specified and as directed by Engineer-in-charge. (Note:- Replaced Spare parts/ engine oil/ coolant shall be measured & paid under appropriate items of Sch 'A')
M&L for dismantling of engine of 25 KVA DG set of any make & type by strip opening and repairing of diesel engine gen set with following repairs/ replacement of worn out spare parts commissioning testing on full load and entire satisfication of Engineer-in-charge after complete repairing (Testing shall be carried out for 08 hrs continious and diesel for testing shall be supplied by the deptt free for testing). (Note:- Spare parts shall be measured & paid as supply only under appropriate items of Sch 'A') (a) Valve set cutting and fixing of valve guide. (b) Fixing of cylinder linner. (c) Cylinder block liner bearing and threading of existing bores. (d) Fixing of piston ring complete. (e) Repair to cylinder block injector sleeves including fixing and testing complete.
M&L for complete servicing of 45 KVADG set of any make and type to made functional replacing unserviceable spare parts, old oil filer, fuel filter , air cleaner filter element including drain out old engine oil (lubricants) and coolant including commissioning & testing on full load upto satisfaction after repair/ replacement at unserviceable parts/filter engine oil/ coolant complete all as specified and as directed by Engineer-in-charge. (Note:- Replaced Spare parts/ engine oil/ coolant shall be measured & paid under appropriate items of Sch 'A')
M&L for dismantling of engine of 45KVA DG set of any make & type by strip opening and repairing of diesel engine gen set with following repairs/ replacement of worn out spare parts commissioning testing on full load and entire satisfication of Engineer-in-charge after complete repairing (Testing shall be carried out for 08 hrs continious and diesel for testing shall be supplied by the deptt free for testing). (Note:- Spare parts shall be measured & paid as supply only under appropriate items of Sch 'A') (a) Valve set cutting and fixing of valve guide. (b) Fixing of cylinder linner. (c) Cylinder block liner bearing and threading of existing bores. (d) Fixing of piston ring complete. (e) Repair to cylinder block injector sleeves including fixing and testing complete.
M&L for complete servicing of 63 KVADG set of any make and type to made functional replacing old oil filer, fuel filter , air cleaner filter element including drain out old engine oil (lubricants) and coolant including commissioning & testing on full load upto satisfaction after repair/ replacement at unserviceable parts/filter engine oil/ coolant etc. complete all as specified and as directed by Engineer-in-charge. (Note:- Replaced Spare parts/ engine oil/ coolant shall be measured & paid under appropriate items of Sch 'A')
M&L for dismantling of engine of 63KVA DG set of any make & type by strip opening and repairing of diesel engine gen set with following repairs/ replacement of worn out spare parts commissioning testing on full load and entire satisfication of Engineer-in-charge after complete repairing (Testing shall be carried out for 08 hrs continious and diesel for testing shall be supplied by the deptt free for testing). (Note:- Spare parts shall be measured & paid as supply only under appropriate items of Sch 'A') (a) Valve set cutting and fixing of valve guide. (b) Fixing of cylinder linner. (c) Cylinder block liner bearing and threading of existing bores. (d) Fixing of piston ring complete. (e) Repair to cylinder block injector sleeves including fixing and testing complete.
Supply only following spare parts suitable for engine of 25 KVA DG to 63.5 KVA DG set of any make and type. (a) Main Bearing
(b) Con Rod bearing
(c) Bearing t/w Kir
(d) pIston ASSEMBLY
(e) Cylender liner
(f) Valve pair inlet & Exhuast
(g) Valve guide
(h) wire snap ring
(j) wire stem seal
(k) Set of joints
(l) Intermediate ring 1.3 mm
(m) Shim Ring cylender
(n) Set of rings
(o) Oil Seal Big size as per requirement
(p) Oil Seal small size as per requirement
(q) Bearing C /Bush Kir
(r) Bearing IG Bush
(s) KOEL CARE super geniune oil 13 Ltr CAN
(t) Fuel filter element pre
(u) Fuel filter element micro
(v) Lube oil filter element
(W) Lube oil pump Assy
(X) Sealing ring
(Y) Hose for air cleaner 70 IDX 80L.
(z) Set of high pressure pipe.
Supply only element fuel filter both primary and secondary suitable for 25 KVA DG set complete all as specified and as directed by Engineer-in-charge. Make:- Mico/Cummins.
Supply only oil filter suitable for 25 KVA DG set complete all as specified and as directed by Engineer-in-charge. Make:- Mico/Cummins.
Supply only element air cleaner inner and outer suitable for 25 KVA DG set complete all as specified and as directed by Engineer-in-charge. Make:- Mico/Cummins
M&L for dismantling unservicable AVR and supply & fixing new AVR, suitable for 25KVA DG set, Make:Kiloskar/Stamford, commissioning & testing on full load complete all as specified and as directed by Engineer-in-charge.
M&L dismantling unservicable. self starter 12 Volt DC with solonied switch suitable for 25 KVA DG set, transporting to civil workshop, complete repairing by replacing unserviceable parts, inatallation, commissioning & testing on full load complete all as specified and as directed by Engineer-in-charge. .Make: Lucas/ Delco
Supply only element fuel filter both primary and secondary suitable for 45 KVA DG set complete all as specified and as directed by Engineer-in-charge. Make:- Mico/Cummins.
Supply only oil filter suitable for 45 KVA DG set complete all as specified and as directed by Engineer-in-charge. Make:- Mico/Cummins.
Supply only element air cleaner inner and outer suitable for 45 KVA DG set complete all as specified and as directed by Engineer-in-charge. Make:- Mico/Cummins
M&L for dismantling unservicable AVR and supply & fixing new AVR, suitable for 45 KVA DG set, Make:Kiloskar/Stamford, commissioning & testing on full load complete all as specified and as directed by Engineer-in-charge.
M&L dismantling unservicable. self starter 12 Volt DC with solonied switch suitable for 45 KVA DG set, transporting to civil workshop, complete repairing by replacing unserviceable parts, inatallation, commissioning & testing on full load complete all as specified and as directed by Engineer-in-charge. .Make: Lucas/ Delco
Supply only element fuel filter both primary and secondary suitable for 63.5KVA DG set complete all as specified and as directed by Engineer-in-charge. Make:- Mico/Cummins.
Supply only oil filter suitable for 62.5/63 KVA DG set complete all as specified and as directed by Engineer-in-charge. Make:- Mico/Cummins.
Supply only element air cleaner inner and outer suitable for 63.5 KVA DG set complete all as specified and as directed by Engineer-in-charge. Make:- Mico/Cummins
M&L for dismantling unservicable AVR and supply & fixing new AVR, suitable for 62.5/63 KVA DG set, Make:Kiloskar/Stamford, commissioning & testing on full load complete all as specified and as directed by Engineer-in-charge.
M&L dismantling unservicable. self starter 12 Volt DC with solonied switch suitable for 62.5/63 KVA DG set, transporting to civil workshop, complete repairing by replacing unserviceable parts, inatallation, commissioning & testing on full load complete all as specified and as directed by Engineer-in-charge.Make: Lucas/ Delco
M&L dismantling unservicable. self starter 12 Volt DC with solonied switch suitable for 25 TO 45 KVA DG set, transporting to civil workshop, complete repairing by replacing unserviceable parts, inatallation, commissioning & testing on full load complete all as specified and as directed by Engineer-in-charge. Make: Lucas/ Delco
M&L dismantling unservicable. self starter 12 Volt DC of 63 KVA DG set, and supply & fixing new self starter 12 Volt DC suitable for 40 KVA DG set, inatallation, commissioning & testing on full load complete all as specified and as directed by Engineer-in-charge. Make: Lucas/ Delco
Supply & replacement of DC battery 12 volts, 180AH complete all as specified and as directed by Engineer-in-charge. Make:-EXIDE/POWER TECH
M&L for dismantling unservicable. battery charging alternator 12V, DC suitable for 25 to 62.5 KVA DG sets, trasporting to civil workshop, complete repairing/ overhauling by replacing unsv parts, inatallation, commissioning & testing on full load complete all as specified and as directed by Engineer-in-charge.
Supply and topping up coolent in radiater of DG sets complete all as specified and as directed by Engineer-in-charge. Make : Castrol or equivalent as approved by GE.
S&F MCCB 100 Amp 25 KA 4 pole 415 Voltscomplete all as specified and as directed by Engineer-in-charge. Make:- Legrand/Shalabh/Havelles.
M&L for painting of DG Set on one coat of synthetic enameled paint of DG set of any make and type installed at varries sites 25 KVA to 62.5 KVA capacity complete with alternator as well as electric panel board by means of spray including preparation of surfaces before painting complete all as specified and as directed by Engineer-in-charge.
Taking out old unserviceble cable of any size complete all as specified and as directed by Engineer-in-charge.
Supply and laying in Trenches/floor/walls/roof cable XLPE insulated PVC un sheathed steel tape/ wire armoured multistranded aluminium conductor cable 1100 volts heavy duty of size 25 sqmm 3.5 core with jointing material like cable lugs ,gland and connecting up complete all as specified and as directed by Engineer-in-charge. Make:- polycab/Havells/plaza
Supply and laying in Trenches/floor/walls/roof cable XLPE insulated PVC un sheathed steel tape/ wire armoured multistranded aluminium conductor cable 1100 volts heavy duty of size 16 sqmm 3.5 core with jointing material like cable lugs ,gland and connecting up complete all as specified and as directed by Engineer-in-charge. Make:- polycab/Havells/plaza
Dismantling of existing defective Rotor of the 45 kva DG set disconnecting the electric connecting coupling pulley and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying ovening overhauling greeasing and fixing in the same position making necessary electric connection and testing on DG set complete all as specified and as directed by Engineer-in-Charge.
Dismantling of existing defective Stator of the 45 kva DG set disconnecting the electric connecting coupling pulley and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying ovening overhauling greeasing and fixing in the same position making necessary electric connection and testing on DG set complete all as specified and as directed by Engineer-in-Charge.
Dismantling of existing defective Excitor of the cap 45 kva to63.5 KVA DG set disconnecting the electric connecting and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying ovening overhauling greeasing and fixing in the same position making necessary electric connection and testing on DG set complete all as specified and as directed by Engineer-in-Charge.
Dismantling of panel wiring of DG set of capaity 25 to 62.5 KVA DG set, and rewiring with suitable size copper wire complete all as specified and as directed by Engineer-in-charge.
M&L for Chane of silicon diode of suitable cap for DG set of cap 25 KVA to 62.5 KVA , commissioning & testing on full load complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of four pole offload changeover switch 100 Amps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Make :- L&T/Siemens/Havells/C&S
S&F in replacement of four pole offload changeover switch 200 Amps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Make :- L&T/Siemens/Havells/C&S
M & L for Shifting to DG set of any Cap and any Size From office complex to E/M installation ( approx 90Km) and commissioning ,testing after refixing the same with connecting acessories as required at site as specified and as directed by Enge -in-charge . transporation deemed to included in rate item
Gill Construction Co
M/s Rohit Construction Co.
J.M.D. CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .