Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.6 LAccepted-AOC ADITYAPUR 1 SARAIKELA KHARASWAN | ADITYAPUR | SARAIKELA KHARASWAN | JHARKHAND | L1 | Accepted-AOC L-1 | |
| 2 | L2₹65.3 L+₹4.7 L (7.75%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹66.7 L+₹6.1 L (10.1%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹67.2 L+₹6.6 L (10.9%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹71.8 L+₹11.2 L (18.5%)Rejected-Finance 00 HANSH NAGAR RADHA RAMAN ROAD MAINPURI MAINPURI UTTAR PRADESH 205001 | MAINPURI | UTTAR PRADESH | 205001 | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | S K Enterprises L5 | M/S RANJULA CONSTRUCTION L4 | M/s. Nirala Construction L1 | KAMESHWAR ENTERPRISE L3 | EVOLVING ERA SERVICES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. | 151.94 | Cum | 4,662 ₹7,08,344.28 | 4,360.45 ₹6,62,526.77 | 2,083 ₹3,16,491.02 Lowest | 4,800 ₹7,29,312 | 4,237.74 ₹6,43,882.22 |
| 2.00 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. | 76.79 | Sqm | 634.3 ₹48,707.9 | 593.27 ₹45,557.2 | 700 ₹53,753 | 650 ₹49,913.5 | 576.57 ₹44,274.81 Lowest |
| 3.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Beam | 80.95 | Cum | 5,608.5 ₹4,54,008.08 | 5,245.83 ₹4,24,649.94 | 3,000 ₹2,42,850 Lowest | 6,000 ₹4,85,700 | 5,098.2 ₹4,12,699.29 |
| 4.00 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers | 164 | Sqm | 323.6 ₹53,070.4 | 302.64 ₹49,632.96 | 430 ₹70,520 | 250 ₹41,000 Lowest | 294.12 ₹48,235.68 |
| 4.01 | Centering and Shuttering including Strutting,propping etc.and removal of form for Suspended floors,roofs,landings,balconies and access platform. | 357.13 | Sqm | 387.4 ₹1,38,352.16 | 362.38 ₹1,29,416.77 | 320 ₹1,14,281.6 | 250 ₹89,282.5 Lowest | 352.19 ₹1,25,777.61 |
| 5.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
1:1.5:3 (1 cement: 1.5 coarse sand(zone-HI): 3 graded stone aggregate 20 mmnominal size) | 22.07 | Cum | 5,407.3 ₹1,19,339.11 | 5,057.56 ₹1,11,620.35 | 5,000 ₹1,10,350 | 5,200 ₹1,14,764 | 4,915.23 ₹1,08,479.13 Lowest |
| 6.00 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts | 274.57 | Sqm | 413.7 ₹1,13,589.61 | 386.96 ₹1,06,247.61 | 320 ₹87,862.4 | 250 ₹68,642.5 Lowest | 376.07 ₹1,03,257.54 |
| 7.00 | Centering and shuttering including strutting, propping etc. and removal of form forWeather shade, Chajjas, corbels etc., including edges | 22.47 | Sqm | 396.1 ₹8,900.37 | 370.47 ₹8,324.46 | 450 ₹10,111.5 | 250 ₹5,617.5 Lowest | 360.05 ₹8,090.32 |
| 8.00 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) | 3.4 | M.T. | 74,066.2 ₹2,51,825.08 | 69,275.61 ₹2,35,537.07 | 65,000 ₹2,21,000 Lowest | 83,000 ₹2,82,200 | 67,326.06 ₹2,28,908.6 |
| 9.00providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) | ||||||||
Tender Value
₹80.8 L
EMD Value
₹1.6 L
Closing Date
3 Feb 2026, 11:00 amClosed
E.E., BCD, Building Division, Jamshedpur
E.E., BCD, Building Division, Jamshedpur
Upgradation of 10 Bedded Hospital at Birsa Nagar in the District of East Singhbhum.
2026_BCD_109446_1
BCD/EE,Building Div.Jamshedpur-57/2025-26
Open Tender
Civil Works - Buildings
Works
270 days
Jamshedpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.6 L
18 Apr 2026
21 Jan 2026
4 Feb 2026
21 Jan 2026
3 Feb 2026
21 Jan 2026
Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Beam
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and Shuttering including Strutting,propping etc.and removal of form for Suspended floors,roofs,landings,balconies and access platform.
Reinforced cement concrete work in walls (any thickness), including attached pilasters buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement: 1.5 coarse sand(zone-HI): 3 graded stone aggregate 20 mmnominal size)
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form forWeather shade, Chajjas, corbels etc., including edges
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
(a) 10mm (TMT coil Fe 500)(only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steel Ltd. Bokaro and Vizag(RINL))
b) 12mm (TMT coil Fe 500)(only valid for Tata(Tiscon),SAIL,JSPL,Electrosteel Steel Ltd. Bokaro and Vizag(RINL))
(c) 16mm (TMT Coil Fe 500) {Only Valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd., Bokaro and Vizag (RINL)}
(d) 20mm to 32 mm (TMT Coil Fe 500) {Only Valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd., Bokaro and Vizag (RINL)}
Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.)
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/l.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kg/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litre/10 sqm, complete as the direction of Engineer -in-Charge.
Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With commercial grade colour Tiles.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .
Providing and laying water proofing treatment to vertical and horizontal surface of depressed portions of W.C. and the like consisting of : - (i) I st course of applying cement slurry @ 4.4 kg/sqm mixwd with water proofing compound conforming to IS 2645 in recommended proportions including off junction of vertical and horizontal surface. (ii) II nd course of 20mm cement plaster 1:3 ( 1 cement :3 coarse sand ) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (III) IIIrd course applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (IV) IVth course of 400 micron thick PVC Sheet (overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Providing and fixing Pressed steel door frames conforming to IS: 4351, manufactured from comercial mild steel sheetof 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshoid of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as direction by engineer-in-charge.
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with one side teak decorative and another side commercial veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (+ 0.2 mm). Both vertical sides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (+ 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer’s specification and direction of engineer- in-charge.
Providing and fixing 37 mm thick factory made PVC Door shutter, styles and made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (+ 0.2 mm) with inbuilt beading on one side, thestyles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (+ 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail be of size 110 mm x 37 mm having wall thickness 2 mm (+ 0.2 mm) to welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer’s specification and direction of engineer-in-charge.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sectionsshall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. With float glass panes of 4.0 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Supplying , fitting and fixing M.S Grill made of 20x6 cmm M.S. flat as per approved design and drawing properly fabricated with joints continuous fillet welded and finished smooth carriage of grill to work site hoisting as per building specification and direction of E/I (where materials is not supplied by the depth.)
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.
110 mm Single pushfit Coupler
110x110x110mm Single tee with door
110mm bend
110 mm shoe
Providing and fixing unplasticised -PVC pipe clips of approved designto unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. 110mm
Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm squarewith a height of 8 mm and weighing not less than 100 gms.
Water proofing for Old and New Roof Slab:- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with. brush, roller or spray for water proofing coating as per manufacturer specifications with following steps: (a) surface preparation:-Providing and cleaning of concrete surface to remove dust, oil, grease Including removal of existing loose paint/ coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to Identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg Dr Fixit/Fosroc or equivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement: sands 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same withcement slurry including all material, labour, tools complete. (b)1st Coat Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green 1st coat should be applied @1.50 kg/SqmU/coat. For the AND purpose of measurement the entire treated surface will be measured." (c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface, 2nd coat should be applied @0,7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:- Sika Topseal 109hl /Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance- Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder- Density 1.6 kg/l (mixed density) at +27°C Tensile Strength - 2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength -2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength-4 N/mm2 (According to FIP 5.15) (According to ASTM D 2370) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According To ASTM D 2370) (d) Protection of treated surface with PCC The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1,5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2 mt x 2mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the screed concrete (paid separately for this items). All comers shall be just leveled with the screed concrete to ensure smooth discharge VERNMES of water-the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture Insensitive epoxy putty of Sika India Pvt.Ltd./MYK Schomberg / Dr Fixit/Fosroc .For the purpose of measurement the entire treated surface will be measured." (e)Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately). Brand- Sika India Pvt.Ltd. /MYK Schomberg/Dr Per M AND Fixit/Fosroc Warranty for five years.
Covering of treated surface with PCC :- Providing 25 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm
Providing and Filling of 6mm thick Groove between 25 mm PCC Panels with Plysulphide Sealant (Poring Grade) as Drawing and Technical specification and direction of E in Charge (with 18% GST) Brand Sika Plysulphide, Fosroc Thioflex 600 Dr. Fixit Pidiseal PS (42P) MYK Seal PS or Equivalent
Providing and fixing false ceiling at all height including providing andfixing of frame work made of special sections, power pressed fromM.S. sheets and galvanized with zinc coating of 120 gms/sqm (bothside inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at1200 mm centre to centre, one flange fixed to the ceiling with dashfastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flangef cleat fixed to the angle hangers of 25x10x0.50 mm of requiredlength with nuts & bolts of required size and other end of anglehanger fixed with intermediate G.I. channels 45x15x0.9 mmrunningat the spacing of 1200 mm centre to centre, to which the ceilingsection 0.5 mm thick bottom wedge of 80 mm with tapered flangesof 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channelwith connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mmthick 27 mm high having flanges of 20 mm and 30 mm long, theperimeter of ceiling fixed to wall/partition with the help of rawl plugsat 450 mm centre, with 25mm long dry wall screws @ 230 mminterval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230 mm c/c, including jointing and finishing to a flush finishof tapered and square edges of the board with recommended jointingcompound , jointing tapes , finishing with jointing compound in 3layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification andalso including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitablyfixed, all complete as per drawings, specification and direction ofthe Engineer in Charge but excluding the cost of painting with :
Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Removal of old tarfelt and disposal of debris with all leads complete job as per direction of El.
Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I.
Supply and stacking of Fly ash conforming to IRC- 58 at site, including carriage, loading , unloading & stacking up to any lead (measured stacks will be reduced by 20% for payment).
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be as done with earth having total minimum compacted thickness 30 cm or decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.: 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Carriage of Materials :- from nearest approved sources of supply including loading into trucks and unloading from trucks and stacking properly at work site as directed by the E/I.
I) Sand - 5km
ii) Aggregate - 20Km
iii) Brick - (1+7) km
Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 Coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) Foundation
Centering and shuttering including Struting, Propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases
Providing and laying 25 mm thick kotah stone slab flooring of approved size, texture and colour over 19mm thick base of lime morter (1:1:1) (lime putty : surkhi: coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (iv) 600x600 mm size
Providing and laying 25mm mm thick kotah stone tiles in risers of steps, skirting and pillars of approved size, texture and colour laid over 12mm thick cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing, cleaning and preparing the walls, scafolding, washing of floor and taxes all complete as per building specification and direction of E/l.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Supplying, fitting and fixing 20 guage G.C.I, sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l.
Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.
Horizontal - 32 mm dia not less then 600 gms
Vertical - 32 mm dia not less then 600 gms
40 mm Dia dia not less then 700 gms
25 mm dia dia not less then 375 gms
Cutting chhajja or corince for laying G.I. / C.P.V.C pipe and restoring the same with R.C.C. (1:2:4) brick work in cement mortor (1:4) as per specification and direction of E/I.
Making holes in walls for laying G.I. / C.P.V.C pipe and restoring the same after pipe laying as per specification and direction of E/I.
125 mm thick wall
250 mm thick wall
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.
Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror. Mirror (600 x 450mm)
C.P. brass dish container medium quality with screw and hinges etc.
Supplying the follwing bathroom fittings all complete
bib cock long thread V.I.P
Pillar cock (long neck) V.I.P.
Angular Stop Cock (long Thread)
Paper holder V.I.P.
Glass self
C.P. brass tower rail
C.P. brass soap dish
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and dirction of E/I.
580mm long With 10 Liter Low Level P.V.C. cistern
Supplying, fitting and fixing viterous white glazed earthen ware E.W.C. of Parry Emdustan or any other.... all complete as per specification and direction of E/I.
With 'P' trap - 10.0 ltr. Low level PVC cistern
Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe
Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I.
for classification of soil item-A
Lbour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I.
150mm dia R.C.C. spun pipe
Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
Supplying NP2 R.C.C. hume pipe with colour as work site as per direction of E/I. 150mm dia
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm witha pair of 15 mm C.P. brass pillar taps
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brazsckets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board : 610x460 mm bowl depth 200 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL/ SUPREME) : 15mm dia
20mm dia
25 mm dia
Providing and fixing PTMT grating of approved quality and colour. C.P. Gratings : Circular type - 100mm dia
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
Provding and laying of 110mm dia. H.D.P.E. pipe for outlet of water to outlet drain including all accessories ,l.e lubricants, solvent cement, clamp, ring, sockets etc.(SUPREME SW.R.) 110 M
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 110x110x110mm
110mm shoe
75mm shoe
Point Wiring in PVC Conduit, with Piano type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size of GI box etc as required.
Group-A
Supply and Fixing Light Plug Point with Piano Type Accessories: Supply and Fixing GI/ PVC box of 75 mmx75mm 50mm deep on surface or in recess with phenolic laminated sheet cover in front including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.
Supply and Fixing Light Plug Point with Piano Type Accessories: Supply and Fixing GI box of 121 mm x 173 mmx 48mm (6"x8") on surface or in recess with phenolic laminated sheet cover in front including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps piano type switch, connection, painting etc as required.
Power Plug Wiring in PVC conduit (2x4 sq. mm): Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 number 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.
2x1.5 Sqmm + 1x1.5 sqmm earth wire
2x2.5 Sqmm + 1x2.5 sqmm earth wire
2x6 Sqmm + 1x6 sqmm earth wire-
2x10 Sqmm +1x10 sqmm earth wire-
4x6 Sqmm + 2x6 sqmm earth wire-
S/F SP MCB DB: Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR).
8 ways Double Door -(Power +Lighting) DB combined for Kitchen at lower ground floor
S/F TP MCB DB: Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR).
4 way(4+12) Double door Horizontal type
S/F 'C' series SP MCB: Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required.
6/32A Single Pole
40A TPN MCB - for Lighting DBs
40A DP MCB for outer light
63A DP MCB
100A 4P MCCB.16kA
S/F VERTICAL Type T.P. MCB DB and fixing of following ways surface/ recess mounting vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned coPPer bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Nobe : Vertical type MCB TPDB is Normally used where 3 phase outleb are required.) Note: Vertical tlpe MCB TPDB is normally used where three phase outlets arc rcquircd. 4 way (8 + 12), Double door, Vertical tlpe
4 way(4+12) Double door Vertical type- Main DBs(1 no GL)
S/F Ceiling Rose: Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
S/F Dingdong Call bell: Supplying and fixing ding dong Sound Call bell, single phase 230 volt, complete as required.
ITC fluorescent fitting directly on surface :- installation testing and commissioning of Pre - wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc, directly on ceiling / wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper cond.
ITC fluorescent fitting with down rods :- installation testing and commissioning of Pre - wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc, including supplying and fixing ball and socket arrangement, 2 nos. down roda of 20mm dia stee.
ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required.
TV cable in Existing Conduit: Supplying and drawing co-axial cable RG-6 grade 0.7mm solid copper conductor, PE insulated with fine tinned copper bread and protectid PVC sheath in the existing surface/ recessed PVC conduit as required.
S/F Piano type Switch / Socket: Supplying and fixing following piano type switch / socket on the existing switch box including connections etc as required.
5/6 AMPS, one way switch
5/6 Amps, 3 pin socket outlet
TV antenna socket outlet
Electronic step fan regulator, mini
S/F PVC/ GI Boxes: Supplying and fixing following size PVC/GI box on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc as required.
75mmX75mmX50mm deep
ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required.
Supplying and fixing following size ISI marked PVC conduit along with acccessories in recess including cutting the wall and marking good the same as required.
20 mm dia
S/F Batten Holder: Supplying and fixing batten/angle holder including connection etc. as required.
Copper Earth Plate Elecrode:- Earthing with copper plate 600mmx 600mmx 3mm thick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or cock and salt) complete etc. as required.
S/L 8 SWG copper wire in ground :- Supplying and laying 8SWG copper wire at 0.50 metere below ground level for conductor earth electrode, including soldering etc. as required.
GI lightning conductor tape in horizontal run - Providing and fixing of GI tape 20mm X3mm thick on parapet or surface of wall for lighting conductor etc complete as required.
GI lightning conductor tape in Vertical run - Providing and fixing of GI tape 20mm X3mm thick on parapet or surface of wall for lighting conductor etc complete as required.
MV Cable:- Supply of ISI marked aluminium cable conductor XLPE PVC insulated cable as per IS:7098 armoured, served, sheathed, 1100V grade with Termination and Laying of cable. Make:- Finolex / Polycab / Havells / Universal
3.5x50 sq. mm armoured AL Cable. For JSEB supply.
MV cable Laying upto 120 Sqmm in ground without sand and cover: Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 120 sq.mm. direct in ground but excluding , sand cushioning, protective covering as required.
Supply Installadon, testing and commissioning of follwing size ceiling fan 3 Blades confirming to 15:374:2019 includlng wtrlng the down rods of standard length (upto 30cm) with 1.Ssq.mm. FR PVC insulaled, coppcr wlre ruttable for 230V 50H2, slngle phase supply etc. complete as required t400mm (56') Cclllng Fan
Supply of Exhaust metal Fan: Supply and fitting of 230mm, 230V AC metal exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required( Make- Polar/ Havells/Crompton)
Supply of Exhaust metal Fan(15") for Kitchen: Supply and fitting of 380mm(15"), 230V AC metal exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required( Make- Polar/ Havells/Crompton)
S.I.T.C of floowlng tatlng surface mounted LED tube Ught fitting suitable for 230V S0Hz, single phase supply etc. complete ar requlred. 20/22W LEDTube light
LED Bulb 9W/10W : Supplying and fixing of LED 9W /10W bulb and accessories as required. ( Make -Bajaj / Havells/ Philips)
S'I'T'C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply vol tage 100-270y AC, soHz. Luminarie shall be conJirm to IS: 10322 part-5/section-5 and shall be Complete wlth all neccssary accessories as required 90800W LED Ftood light
Downlighter(Surface) 18/20W LED: Supply erection and commissioning of LED 18/20W, sleek surface-mounted, round LED downlight for soft diffused lighting and all accessories as required. ( make Havells/ Baja-BGSLO 18 WH / Philips)
Add 18 % GST (in Basic Rate must fill 12)
Add 1% Labour Cess (in Basic Rate must fill 1)
stage.html
html • 0.06 MB
technical_147850.pdf
techsummary_147850.pdf
finance_147850.pdf
BOQ Comparative Chart
xlsx
finsummary_147850.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
F-2.pdf
Tender Documents • 3.80 MB
BOQ_147850.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .