| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹5.8 L+₹1.3 L (29.0%)Rejected-Finance 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance HIGHER AMOUNT QUOTED | |
| 3 | L3₹5.9 L+₹1.5 L (32.9%)Rejected-Finance | L3 | Rejected-Finance HIGHER AMOUNT QUOTED | |
| 4 | L4₹7.9 L+₹3.5 L (77.1%)Rejected-Finance 9 SHUBHASH BHAWAN RAJENDAR MARG MOUNT ABU 307 501 | MOUNT ABU | SIROHI | RAJASTHAN | 307501 | L4 | Rejected-Finance HIGHER AMOUNT QUOTED | |
| 5 | L5₹8.0 L+₹3.5 L (78.3%)Rejected-Finance | L5 | Rejected-Finance HIGHER AMOUNT QUOTED |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
29 Aug 2020, 6:00 pmClosed
AGE I UDAIPUR
ASST. GARRISON ENGINEER (I) EKLINGGARH CANTT, UDAIPUR (RAJ.) - 313001
REPAIR AND MAINT OF INTERNAL ELECTRIFICATION AND FITTINGS OF MD AND OTM ACCN IN ARMY AREA AT MOUNT ABU
2020_MES_367040_1
8539/E8/AGE I UDAIPUR
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ARMY AREA MOUNT ABU
AS PER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹500
AGE I UDAIPUR
₹15,000
Yes
19 Dec 2020
6 Aug 2020
31 Aug 2020
6 Aug 2020
29 Aug 2020
14 Aug 2020
Amount
Taking down carefully aluminum/copper point wiring (light/fan/socket/power) complete including fittings such as switch, socket, ceiling roses light fittings etc and making good disturbed surface of wall all as specified and directed by Engineer-in-Charge. (Serviceable light fitting to be kept separately for re-use).
Material and labour point wiring complete with 1.5 sq mm single core multi stranded copper conductor PVC (F.R.L.S) insulated unsheathed 1100 Volt grade cable in and incl PVC casing capping of size as required (ISI Marked) with accessories including new pressed steel terminal boxes (sunk in wall ) including, 3.00 mm thick plastic laminated sheet top cover with 1.50 sq mm insulated unsheathed PVC multistranded covered copper conductor for common earth and connecting to earth dolly and making good disturbed surface of wall incl matching the colour of wall/ceiling with extisting wall/ceiling all as specified and directed for :-
(a) One light point controlled by one switch one way
(b) One fan point controlled by one switch one way
(c) One socket out let 5 Amps 5 Pin on same board with other switch
(d) One socket out let 5 Amps 5 pin on independent board
(e) One call bell point controlled by one bell push .
(f) One light point controlled by two switch two way
All as per item No 2 here in before but cable of size 2.5 Sqmm for one 15 Amps socket outlet on independent board and multistanded insulated copper earth continuity conductor of size 1.5 Sq mm all as spd and directed by Engr-in-Charge.
Material and labour point wiring complete with 1.5 sq mm single core multi stranded copper conductor PVC (F.R.L.S) insulated unsheathed 1100 Volt grade cable in and incl concealed PVC Conduit of 25/32 mm (ISI Marked) with accessories including new pressed steel terminal boxes or modular metal flush box (sunk in wall ) and 3.00 sq mm thick plastic laminated sheet top cover or modular cover plate (modular cover plate paid seperately) with 1.50 sq mm insulated unsheathed PVC multistranded covered copper conductor for common earth and connecting to earth dolly making good disturbed surface of wall incl matching the colour of wall/ceiling with extisting wall/ceiling all as specified and directed for :-
(a) One light point controlled by one switch one way
(b) One fan point controlled by one switch one way
(c) One socket out let 5 Amps 5 Pin on same board with other switch
(d) One socket out let 5 Amps 5 pin on independent board
(e) One call bell point controlled by one bell push .
(f) One light point controlled by two switch two way
All as per item No 4 here in before but cable of size 2.5 Sqmm for one 15 Amps socket outlet on independent board and multistanded insulated copper earth continuity conductor of size 1.5 Sq mm all as specified and directed by Engr-in-Charge.
Material and labour for Elect bell AC 230 Volts single phase musical type.
Material and labour for bell push flush type 5 Amps .
Supply and fixing switch piano flush type 5 Amps single pole one way.
Supply and fixing socket out let 2 in 1 multi pin 5 Amps flush type universal.
Supply and fixing switch socket combination 2 in 1, multi pin 5 Amps flush type universal.
Supply and fixing 5 Amp switch two way flush type
Supply and fixing Ceiling rose on PVC board size 65 X 50 mm three terminal Complete.
Supply and fixing angle lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings.
Supply and fixing stepped type electronic fan regulator flush type including cutting slot on the existing phenolic laminated sheet or replace Phenolic laminated sheet all as per site requirement and directed .
Taking down old DBs and Supply and fixing Double door MCB DB SPN 8 way comprising of sheet metal enclosure powder coated fitted with bus bar 200 Amps 240 volts.
Taking down old DBs and Supply and fixing Double door MCB DB TPN 4 way comprising of sheet metal enclosure powder coated fitted with bus bar 200 Amps 415 volts.
Taking down old fittings and supply & fixing LED Tube light fitting 20 Watt including tube rod , flexible copper cable of required length from ceiling rose to light fitting complete all as specified. Make : crompton/Philips or approved by Engr-in-charge
Taking down existing fittings/holder and supply & Fixing LED tube light fitting 9w 2 feet Make : phillips astro line or equivalent to CG approved by Engr-in-charge
Supply &fixing of bedside light 3W with flexible arm to set light focus as per requirement Make : Philips 48042 or equivalent of approved make or approved by Engr-in-charge.
Supply and fixing of ceiling LED light 2'x2' 36 W
Taking out old worn out wooden frame/rusted metal boxes and supply & fixing sheet metal board complete with flush door handle with locking arrangement painted with powder coated finishing with necessary PCC work complete size 60x60x20 cm x 2.00 mm thick including refixing the old DBs, MCBs and Electric Meter.
Taking out old worn out wooden frame/rusted metal boxes and supply & fixing sheet metal board complete with flush door handle with locking arrangement painted with powder coated finishing with necessary PCC work complete size 90x65x30 cm x 3.00 mm thick including refixing the existing serviceable DB etc.
Taking down and Supply & Fixing MCB single pole 240 volts upto 10 Amps
Taking down and Supply & Fixing MCB SP 240 volts upto 16 Amps.
Taking down and Supply & Fixing MCB SPN 240 volts upto 32 Amps.
Taking down and Supply & Fixing MCB TPN 415 volt 40 to 63 Amps.
Taking down old submain wiring and M & L for sub main wiring with 2 single core 6 Sqmm copper conductor (Multistandered) in PVC conduit of suitable size as required, PVC board with all fittings including 2.5 Sqmm copper conductor as earth continuity all as directed.
Taking down old submain wiring and M & L for sub main wiring with 2 single core 4 Sqmm copper conductor (Multistandered) in PVC conduit of suitable size as required, PVC board with all fittings including 2.5 Sqmm copper conductor as earth continuity all as directed.
Dismantling carefully for cutting down and removing old burnt copper wire winding of ceiling fans of size 1200 mm sweep of any make and rewinding with new enameled super copper wire of existing gauge as per old copper winding incl providing insulation by varnishing (golden), cleaning, oiling, greasing etc and refixing all as specified and directed by Engr-in-Charge.
Dismantling carefully for cutting down and removing old burnt copper wire for winding of exhaust fan of size upto 450 mm sweep of any make and rewinding with new enamelled super copper wire of existing gauge as per old copper winding including provinding insulation by varnishing (golden), cleaning, oiling, greasing etc and refixing all as specified and directed.
Disconnecting/taking down ceiling fan including down rod and dismantling carefully all parts of ceiling fans of 48" (1200mm) sizes, cleaning, oiling, greasing etc and refixing all the parts, replace bolts-nuts-washers & pins to connect down rod, remounting and testing all as specified & directed by Engr-in-Charge.
Note : (i) For Srl No 29 to 31 : The super enameled winding wire is to be provided shall be appropriate gauge as directed by Engr-in-Charge. (ii) Any unsv parts reqd for replacement shall be measured and paid separately under respective item of Sch 'A' as supply only
Supply only ball bearing suitable for ceiling fans of following size complete all as specified and directed by Engr-in-Charge
Supply only ball bearing suitable for exhaust fans of following size complete all as specified and directed by Engr-in-Charge
Supply only capacitor 2.5/4.0 mfd for ceiling fans/exhaust fan of following capacity/ISI marked :-
Supply & fixing of shackle clamp of mild steel galvanised iron, heavy duty with rubber reel bolt suitable for ceiling fans (Any type, sweep and make) complete all as specified and directed by Engr-in-Charge.
Taking down cleaning, scraping of surface of ceiling fan and two coat of synthetic enemal white spray paint over fan motor, blade set & down rod, writing of fan number in black paint all as directed.
Supply and fixing of ceiling fan blade for 1200mm sweep in white colour as per sample with screw.
M/S Balkishan Panwar Construction
boon construction company
Haritwal traders
Choudhary Traders and Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .