Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.5 L+₹30,545 (1.08%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹29.7 L+₹1.5 L (5.15%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹33.3 L+₹5.0 L (17.9%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹34.4 L+₹6.2 L (22.1%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹33.9 L
EMD Value
₹67,800
Closing Date
7 Jan 2020, 6:00 pmClosed
GE Jaipur
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
SPECIAL REPAIR OF 04 TOILET BLOCKS OF MH JAIPUR AND REPAIR AND REPLACEMEMT OF LED LIGHTS IN VARIOUS WARDS AND DEPT OF NEW HOSPITAL BLDG NO P-48 AND REWIRING TO BLDG NO P-01 UNDER ZONE II AT JAIPUR MIL STN
2019_MES_308230_1
GE/J-52/2019-2020
Open Tender
Civil Works
Item Rate
120 days
GE Jaipur
Class D and Category a(i) and b(i)
8 documents required · 8 mandatory
₹500
GE Jaipur
₹67,800
Yes
1 Feb 2020
20 Dec 2019
9 Jan 2020
20 Dec 2019
7 Jan 2020
1 Jan 2020
20 Dec 2019 - 31 Dec 2019
Amount
Scrapping roof surface with wire brushes and washing with water etc including taking down old cement plaster, PCC in any situation position and roof treatment any type for making good to receive new roof treatment any type and removal of same from site to outside of MOD land complete all as specified and directed.
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean drysand 1:1 (by weight).
M&L for screed/plaster 15mm thick in (CM 1:4) on roof for surfaces mixed with appd liquid type water proofing compound as per manufacture instuctions. Work or concrete surfaces.
Supply only liquid water proofing compound
M&L paddiing in PCC 1:2:4 type B-0 (using 12.5mm size graded stone aggregates) laid to average consolidated thickness of 40 mm to provide a finished slope of 1:30
M&L for water proofimg treatment to non accessible roof slabs by applying one coat of bituminous primer conforming to IS-3384 @ 0.30 ltr /sqm and laying Actitic Polypropylene (APP) modified memmbrane, reinforced with non woven polyester , of 3.5 kg /sqm ( minimum 3 mm thick), with minimum 75 mm side over laps and 100 mm end over laps, laid by torch application and applying one coat of bituminous aluminium paint over APP membrane all as specified and directed .
Dismantling water tanks,exc 500 and n.exc 1000 litr
Dismantling water tanks,exc 250 and n.exc 500 litr
S&F rotational moulded polyethylene water storage tanks of 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including taking down old damaged tanks.
S&F rotational moulded polyethylene water storage tanks of 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including taking down old damaged tanks
S & F Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20mm dia (minimum weight 210 gms) complete
Takig up or down 15 mm GI tubing medium grade with all fitting and fixed to walls and ceiling or laid in floor complete
Takig up or down 20 mm GI tubing medium grade with all fitting and fixed to walls and ceiling or laid in floor
Takig up or down 25 mm GI tubing medium grade with all fitting and fixed to walls and ceiling or laid in floor
Supply and Fixing 15 mm GI steel tubing medium grade with all fittings fixed to walls and ceiling or laid in floor complete
Supply and Fixing 20mm GI steel tubing medium grade with all fittings fixed to walls and ceiling or laid in floor complete
Supply and Fixing 25 mm GI steel tubing medium grade with all fittings fixed to walls and ceiling or laid in floor complete
S & F in repairs 15mm bore angle stop valves cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for union
S & F in repairs 15mm bore CP angle valve cast copper alloy screwed down,high pressure with capston head,screwed both ends for iron pipe or for union.Make-Jaquar Cat part No QQT 7053 fixed in repairs.
S&F in repair central hole single lever wash basin mixer 15mm dia 450 mm Jaquar Cat part No QQT 7001 B fixed in repairs.
S&F in repair 15mm bore bib tap two way,cast copper alloy chromium plated.fancy type with capston head,screwed down, screwed for iron pipe or for brass ferrule.Make Jaquar Cat Part No QQT -7041 fixed in repairs.
S&F in repair Jet suitable forEWC with 01 mtr pipe.
S&F in repair Vitreous China snow white colour wash basin,Cyress pattern Size with pedestal,32mm dia CP waste cupling,bottle trap & all Connected items.Make CERA Cat Part No 1071 & 1171 or equivalent as approved by GE
S&F in repair soap tray chromium plated complete all as specified and directed.Make CERA Cat Part No CA 606 or Equilant in Jaguar or equivalent as approved by GE
S&F in repair brass CP Maggine holder complete all as specified.
S&F in repair toilet paper holder Make-Cera Cat Part No CA 106 or Equilant in Jaquar or equivalent as approved by GE
S&F in repair corner glass self large 300mmx300mm complete all as specified.
S&F in Repair PVC low level flushing cistern 10 litres capacity with inlet ball valve, float and handles including brackets, 15mm dia PVC Connection & Flushing pipe all as specified & directed . Make Cera or equivalent as approved by GE
S&F in repair Bib taps in rep, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
S&F in Repair Gun Metal Gate valves with iron wheel head screwed both ends for iron pipes of 20mm dia.
S&F in Repairs Tubular Towel Rail of 20mm dia of 60cm in length, D shaped, with brass chromium plated brackets all as specified and directed.
S&F in Repair Vitreous China Wash down water closet pan pedastel pattern (EWC) white in colour with and incl plastic water seat and cover white closed pattern with flat bottom and cover and MS chromium plated hinging device incl connection to outgoing pipe and flushing pipe complete all as specified & directed by Engineer-in-charge.Make Cera
Taking down eaves gutters and rain water pipes (any size or pattern) including all fittings, heads, shoes, bends swan neck etc.
M&L for 75mm bore PVC (SWR) Pipes single socketed in any length with rubber ring joints, laid in floors
M&L for 110mm bore PVC (SWR) Pipes single socketed in any length with rubber ring joints, laid in floors
M&L for PVC (SWR) bends 110mm dia any radius
M&L for PVC (SWR) bends 75mm dia any radius
M&L for PVC (SWR) junction single, (Single T) equal or unequal of 75mm bore of pipe
M&L for PVC (SWR) junction single, (Single T) equal or unequal of 110mm bore of pipe
M&L for 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc complete.
M&L for 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc complete.
M&L for PVC (SWR bends) 110mm dia provided with access doors.
M&L for PVC (SWR) bends 75mm dia provided with access doors.
M&L for PVC (SWR) junction double, (Double T) equal or unequal of 110mm bore of pipe
M&L for PVC (SWR) junction single, (Double T) equal or unequal of 75mm bore of pipe
M&L for PVC (SWR) Vent Cowl 110mm dia
M&L for PVC (SWR) Vent Cowl 75 mm dia
M&L for PVC (SWR) floor trap, plain with grating including jointing with solvent cement fixed to 75mm bore of pipe
M&L for Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 for dia of pipe
All as per item No 50 above but 75mm dia of pipe.
Taking down cement plaster or cement lime plaster/ tiles of any description on PCC/ stone surface/ brick surfaces of wall or ceiling including raking outs joint hacking for key scrubbing down with water etc
M & L rendering 15mm thick on stone masonary surfaces or surface other than fair faces of brick work on wall in CM (1:6) finished even and smooth without using extra cement.
M&L for rendering 15mm thick on stone masonry walls in CM 1:4 on walls finished even and fair without using extra cement.
M&L for rendering 10 mm thick in CM 1:3 on ceiling finished even and fair without using extra cement.
Dismantling floor, heart or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises
S&F non skid jt free coloured ceramic tiles fisrt quality of size 300x300x 7 to 8 mm th , in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match shade of tiles over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F joint free coloured glazed ceramic tiles fisrt quality of size 300x450x 7 to 8 mm th , in skirting,dado etc set and jointed in neat cement slurry and pointed in coloured cement to match shade of tiles over and including 10mm thick screed bed in CM 1:4 complete all as specified and directed
Taking down chowkats or frames with shutters n exc 1.50 Sqm each (without taking off shutters from the frames).
Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing
S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed Length of bolt 100 mm
S&F Extruded aluminium alloy handles, fabricated type, anodised size of handle 100 mm
Disconnecting old unserviceable soak well and M&L for construction of soak well 2.40 metre internal dia and over all depth of 3.00 including necessary excavation and earth work in any type of soil PCC 1:4:8 type D-2 using 40mm graded stone aggregate and RCC 1:2:4 type B-1 complete all as specified and shown on drg No CEJZ/2004/TD/S-35 sh 1/1 dated 11 May 2004.
S & F Butt hinges, extruded aluminium alloy 100mm
S/F framed work as in doors or gates of angle or other section as chowkhat., tie bar, hold fast, guard bars complete cooler stand etc, drilled for fixing complete Fe-410
M&L stainless steel wire mesh 0.36mm dia and 1.40mm average aparture.and fixed with stain lesselste wire staples.
M&L 150mm long handle cast type anodised .
M&L 75mm long aluminium door stoppers with two rubber shoes.
S & F stainless steel butt hinges, medium weight, , 100 mm long, fixed to angle iron chowkhats including welding or toPVC/ wooden chokhats complete.
S&F 3mm th sheet glass ordinay quality glazing with oil putty in square n exc0 .5 sqm in each pane fixed to metal framewith glazing pins complete.
M & L Preparing newly untreated steel surfaces of any descripton over 10 cm wiidth or girth and applying two coat of synthetic enamel paints over a coat of red oxide primer
Demolition of brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M & L Brickwork old size brick with fly ash bricks, traight or curved on plan exc 6m mean radius, built in CM 1:6
M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of primer.
M&L preparation of newly plastered surfaces and applying two coats of oil bound distemper over a coat of Birla putty on walls.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of Oil bond Distemper on ceiling
M&L Preparation of old plastered surfaces of wall and applying one coat of cement base paint.
M&L Preparation of old plastered surfaces of wall and applying one coats of oil bound distemper.
M & L for preparation of new plastered surfaces of ceiling and applying two coats of white wash on ceiling
M & L one coat of synthetic enamel paint (ordinary tint) after preparation of old painted steel surface , over 10 cm width or girth not otherwise described.
Dismantling RCC trellies work(jafri) all as specified and as directed.
Providing precast cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate for louvres and jallies, 30 mm thick (measured solid), including all mouldings but excluding frame set in cement mortar 1:4 all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons laid bedded and pointed in any mortar and removal of same from outside MOD land complete all as specified and as directed by Engineer-in-Charge.
M & L machine pressed rubber moulded precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness M-35 grade, with grey cement laid over and including 25 mm thick sand cushion and joints of interlocking tiles filled with dry sand and compacted with mechanical plate vibrator over 75mm thick PCC (1:4: 8) using 40mm graded stone aggregate complete all as specified and directed
M&L for Providing, pre cast rubber moulded kerb stone in cement concrete 1:2:4 type B1 using 20mm graded stone aggregate all as specified and as directed
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out hard/dense soil
All as per item No 87 here-in-before but for depth exc 1.5m and not exc 3m
M&L concrete bed in PCC 1:4:8 type D-2 to drain pipes 100mm bore of pipes including packing under and haunching against the sides of pipes after they are laid and tested
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm each
Removing the excavated material exc 250m but not exc 1.5km and deposing where directed at a level not exc 1.5m above the starting point
Demolition and breaking up drain pipes (salt glazed stoneware, AC or reinforced concrete pipes) 150mm internal dia set in cement mortar
S&F salt glazed stoneware drain pipes as per IS-651 150mm dia laid in trenches and jointed in cement complete all as specified.
M&L concrete bed in PCC 1:4:8 type D-2 to drain pipes of 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested.
M&L providing precast cement concrete 1:2:4 type B-1 using 20mm graded aggregate as in cover slabs (for manholes etc) and shifting to different places and set in cement mortar 1:4 all as directed by Engineer-in-Charge.
M&L TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia
S&F in repairs Vitreous China bowl urinal flat black, size of 465 x 355 x 265mm white with grating and union for discharge pipe incl providing and fixing plugs, bedding urinal against wall in CM 1:2 securing urinal to plugs with & incl 60mm long brass screws, pointing around urinal back in cement
S&F Vitreous China urinals, bowl type (back or corner wall type), 420x395x635mm size of make Cera cat part no 5001 or equvalent complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe.
S &F in repairs Vitreous China Squatting pan, Orrisa' pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern & flush pipe) and making good to floor.
S &F in repairs Vitreous China wash down water closet (Pedestal pattern) complete fixed in repairs
S&F grating doom 125mm dia with waste hole of PTMT (Minimum weight 40 gms) fixed in repair.
S&F in repairs Steel ventilator with top hung shutter with glazing bars including hinges steel peg stay etc complete incl taking down old ventilator.
S & F 200mm long mild steel barrel tower bolts, stove enameled black with bright bolt (ISI marked)
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets, light fittings etc and making good disturbed surfaces even and smooth using 1:3 including white/colour wash to match the existing surface complete.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators as required for for one light point controlled by one switch.
All as per item 105 but one fan point controlled by one switch.
All as per item 105 but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item 105 but one socket outlet 6 amp controlled by one switch on indepdendent board.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets as required for one 16 amp socket outlet point controlled by one switch on independent board.
S&F angle holder, insulated polycabonate body with back plate complete. Make - Havells Reo / Anchor Penta PC / SSK as approved.
S&F switch piano flush button single pole one way 6 amp complete. Make - Havells Reo / Anchor Penta PC / SSK as approved.
S&F switch piano flush button single pole one way 16 amp complete. Make - Havells Reo / Anchor Penta PC / SSK as approved.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete. Make - Havells Reo / Anchor Penta PC / SSK as approved.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete. Make - Havells Reo / Anchor Penta PC / SSK as approved.
S&F ceiling rose 3 plates polycarbonate body complete. Make - Havells Reo / Anchor Penta PC / SSK as approved.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete. Make - Havells Reo / Anchor Penta PC / SSK as approved.
S&F LED batten (1.2 m) made of CRCA sheet housing with a PC glossy difusser and mounting accessories duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 19 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make - Philips cat ref no. ENDURALED BATTEN "BN 108C LED 20S PSU CDL WH" or equivalent in other specified make as approved.
S&F LED bulkhead fitting 9 watt IP 66 & IK 09 with pressure diecast aluminum housing & polycarbonate diffuser duly prewired connection with 0.75 sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable all as per Philips cat ref no. WT202W LED6S PSU S1 PC or equivalent in other specified make as approved.
S&F energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required. Make - Philips cat ref no. RC365B LED33- 6500 PSU OD WH or equivalent in Wipro or Havells as approved.
Taking down carefully tube lightt fittinngs upto 40 watt
Taking down carefully old ceiling fittings including disconnecting complete
Taking down carefully old bulk head fitting
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in modular metal flush boxes with modular white cover plate with frame switches, sockets, fan regulators as required for one light point controlled by one switch. (Note - The cost of cutting chases in stone masonary and making good disturbed surfaces using CM 1:3 and white/colour washing to match the surface shall deemed to be included in quoted rate of the concealed wiring)
All as per item 123 but one fan point controlled by one switch.
All as per item 123 but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item 123 but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item 123 but one light point controlled by two, two way switches.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 2.5 Sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and sunken galvanised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenoic laminated white sheet cover for mounting switches, sockets as required for one 16 Amps socket outlet point controlled by one switch on independent board. (Note - The cost of cutting chases in stone masonary and making good disturbed surfaces using CM 1:3 and white/colour washing to match the surface shall deemed to be included in quoted rate of the concealed wiring)
S&F switch modular 1 way 6 Amps, 230 volts, 1 module.Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular switch 1 way 16 Amps, 230 volts, 1 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and terminated in modular metal flush boxes with modular white cover plate with frame for one socket point 16 Amps controlled by one switch. (Note - The cost of cutting chases in stone masonary and making good disturbed surfaces using CM 1:3 and white/colour washing to match the surface shall deemed to be included in quoted rate of the concealed wiring)
S&F modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular fan regulator 120 watts, 2-module AC 230 Volts. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F switch modular 2 way 6 Amps, 230 volts, 1 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S & F modular blanking plate 1 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F TV socket 1 Module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F RJ 11 telephone socket 1 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular whiter cover plate with frame and metal flush box 1/2 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular whiter cover plate with frame and metal flush box 3 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular whiter cover plate with frame and metal flush box 4 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular whiter cover plate with frame and metal flush box 6 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular whiter cover plate with frame and metal flush box 8 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F ceiling rose 3 plates polycarbonate body complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F in repair LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 125 lumen per watt and total power consumption not more than 16 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete. Make : Philips Cat Ref No. Endura Next Batten "BN 308C LED 20S -6500 L 60 PSU WH" or equivalent in CG/ Bajaj/Panasonic as approved.
S&F LED bulk head fitting 9 watt IP 66 & IK 09 with pressure die cast aluminium housing & polycarbonate diffuser duly pre wired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable all as per Philips Cat Ref No. WT 202W LED 6S PSU S2 PC or equivalent in Panasonic/Havells/CG as approved.
S&F revolving type mirror light of polycarbonate body of capacity 11 watts having lumens output 95 lumens/watts.
S&F in repair surface mounted LED panel of size 220mmx220mm, 12 watt 1500 lumen output having luminous efficacy >85 Im/W, 6500K, 50Hz, p.f. .0.90, CRI80, THD ,30%, 25000 burning hours including making connection. Make : Philips Cat Part No SM 260C LD 12S-6500 PSU WH or equivalent in Havells/CG/Panasonic as approved.
Supply and fixing in replacement 8 watts wall mounted LED decorative luminary with standard accessories and lamp including fixing the same with existing wall. Make : Philips cat part No. LHJE01106499 or equivalent in bajaj/Philips/Panasonic as approved by GE
M&L for sub main wiring along with earth continuity conductor with, PVC insulated FRLS multistranded copper conductor cable (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories 2x6 Sqmm + 1x6 Sqmm earth wire in 20mm dia conduit.
M&L for sub main wiring along with earth continuity conductor with, PVC insulated FRLS multistranded copper conductor cable (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories 4x10 Sqmm + 1x10 Sqmm earth wire in 32mm dia conduit.
S&F MCB distribution board, powder coated, SPN , 240 volts, 8 ways,CRCA steel sheet, degree of protection IP 43 - IK 09, with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. Legrand Cat Ref No. 507611 or Schneider cat ref No A9HSND08 or equivalent in Hager as approved.
S&F MCB distribution board, powder coated, TPN , 415 volts, 4 ways,CRCA steel sheet constructed as per IS:8623, degree of protection IP 43 - IK 09, with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. Legrand Cat Ref No. 507670 or Schneider cat ref No A9HTND04 or equivalent in Hager as approved.
S&F MCBs of 'C' series four pole 40 to 63 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete. Make : Legrand Cat Ref No. 408700 to 408702 or Schneider cat ref No A9N4P40C to A9N4P63C or equivalent in Hager as approved.
S&F MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete. Make : Legrand Cat Ref No. 408587 to 408595 or equivalent in Schneider/Hager as approved.
S&F MCBs of 'C' series double pole 10 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete. Make : Legrand Cat Ref No. 408631 to 408636 or equivalent in Schneider/Hager as approved.
Supply, installation, testing and commissioning of LT panel board fabricated out of 2mm thick stainless steel (SS 316) with copper bus bar 4 pole equal of capacity in colour code R, Y & B, 100 Amps 415 volts outdoor type installed on procelain insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class IP 42 class, front opening & compartmental type with approach for cable entry and for easy maintenance duly internally wired with FRLS, PVC insulated stranded copper conductor cable of 1.0 Sqmm including LED indicator for R, Y & B and comprising of the following :- Incoming :- (a) On load change over switch 160 Amps 4 Pole AC 415 volts - 01 No. (b) MCCB 160 Amps 4 pole 16 KA 415 volts, 70-100%, 50 Hz - 01No. Outgoing :- (a) MCCB 63 Amps 3 pole 16 KA 415 volts ICS = Icu - 02 Nos. (b) MCB DB 10 to 32 Amps AC 230 VOlts - 04 Nos. (c) MCB SP 10 to 32 Amps AC 230 volts - 10 Nos (d) Multifuntional digital meter to read the values of voltage, current frequency & power factor 415 volts. (e) Digital type tamper proof energy meter three phase 0-150 Amps with CTs and wiring complete - 01 Nos.
M&L for earthing with galvanized steel earth plate electrode 600mmx 600mmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with the top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 25x6mm by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No. 03 of MES Schedule Part -I connected to earthing point and testing on completion with and including 40mm grade G.I. protection pipe (upto 7.5 mtr beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mmdiaM.S. bar 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earh work including testing on completion.
S&F single pole and neutral, 20 amp socket outlet with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16 Amp as required. Make : Legrand/Hager/Schneider as approved.
M&L for brick work with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 and plastering 10mm thick in CM 1:4 and 2 coats of white/colour washing to match the existing surface complete.
Supplying, laying/fixing on wall with suitable size of SWR metal clamp having 1.5 mm thickness and 18mm width and passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape/wire armoured underground stranded aluminium conductor cable of 16 Sqmm 2 core. Make : Havells/polycab/Finoles/Universal as approved)
Excavation in soft/loose soil in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out complete.
Removing surplus soil to a distance not exceeding 50m and depositing at alevel not exceeding 1.5m above the starting point complete.
M&L for sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete.
Supplying and laying old size bricks, common burnt clay building bricks sub class 'B' designation 75 laid in trenches over sand for cable protection complete.
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 80mm & inner pipe dia 50mm duly filled with highly conductive and anti corresive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc Sulphate 10%, Aluminium Sulphate 10% burried in ground by digging a bore of 150mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth strip 32 x 6 mm, making PCC pit of size 0.3m x 0.3m x 0.3m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with lifting hook made out of 8mm dia bar and testing on completion to achieve value not more than 2.0 ohm complete. (Note - GI strip size 32x6mm upto 7.5 included in the item)
Supply & fix exhaust fans AC single phase 230/240 V of size 300mm sweep with louve. Make : Bajaj/Havells/Usha or equivalent as approved by GE
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes not less than 1.0 mm and white modular mounting cover plate with frame for mounting modular switches, sockets, fan regulators etc as required for the one light point controlled by one switch.
All as per item No 168 but one fan/exhaust fan point controlled by one switch
Supplying & fixing in repairs LED batten 9 watts, 900 lumens operating voltage 160 to 360 volts, colour temperature 6500K including connection all as per philips Astra Line 9 Watt LED Batten or equivalent in Wipro or CG as approved.
S&F LED bulb 12 watt.
Taking down industrial plug and socket including one number sigle pole MCB any make, any capacity after disconnecting complete.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnection complete.
Schedule of Credit
M/S Mohan Lal Gupta
M/S S R CONSTRUCTION
J.J.ENGINEERING
Smita Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .