| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹3.6 L−₹8.1 L (69.6%)Rejected-Finance | L2 | Rejected-Finance Not L1 |
Tender Value
₹11.6 L
EMD Value
₹23,200
Closing Date
31 Dec 2019, 6:00 pmClosed
CWE(ARMY)SECUNDERABAD
CWE(ARMY) MUDFORT COMPLEX, SECUNDERABAD- 500003
SPECIAL REPAIRS/REPLACEMENT TO CENTRAL FIRE PREVENTION SYSTEM AT IT CENTRE AT CDM SECUNDERABAD
2019_MES_283575_1
CWE(S)/UTILITY/TOKEN-17 OF 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Secunderabad
As per NIT
6 documents required · 6 mandatory
₹500
GE(Utility) Secunderabad
₹23,200
Yes
8 Feb 2020
19 Sept 2019
6 Jan 2020
19 Sept 2019
31 Dec 2019
30 Nov 2019
Amount
Supply,Installtion,commissioning and testing of control panel to preform automatic 24/7 fire protection. Detection options include smoke, heat and flame detection. Control panel consisting zone type microprocessor based panel. the process detection signals from protected conventional 2 zones and actuation to gas Release and is connected to CO2 cylinder bank of two main zones consisting of 07 cylinders in each zone of 45 kg. and complete all as specified and directed. Make; Reliance fire and safety ltd/Tata honeywell/Siemens/Notifier/Esis
M&L for filling of CO2 gas in 45 kg cylinders of CO2 bank and Painting and including disconnecting the cylinders from manifold and refixing carefully with necessary teflon thread seal tape and hardware at site complete all as specified and directed.
Supply,Installation,commissioning and testing of smoke detector of type Photoelectric / Optical with base with self inbuilt intelligence and compared to EN-45 addressable type complete all as specified and directed. Make: Reliance/Zeco Wizmart/Notifier
Supply,Installtion,commissioning and testing of Hooter/Siren type Optical with base with self inbuilt intelligence and compared to EN-45 addressable type complete all as specified and directed. Make: Reliance/Zeco Wizmart/Notifier
Supply,Installtion,commissioning and testing of Heat detector type Photoelectric / Optical with base with self inbuilt intelligence andcompared to EN-45 addressable type complete all as specified and directed. Make: Reliance/Zeco Wizmart/Notifier
Supply and replacement of 1/4'' highly inflamable hose pipe assy of length 300mm (as per sample) and is connected to CO2 gas cylinder master valve to slave valve assy and approved ISI std and specified and directed.
Supply and replacement of 1/4'' highly inflamable hose pipe assy of length 500mm (as per sample) and is connected to CO2 gas cylinder master valve to header pipe and complete all as approved ISI std and specified and directed.
Supply only PVC insulated (FRLS) multi stranded copper conductor two core of size 1.5 Sqmm complete all as specified and directed. Make: Polycab/Havells/HPL
M&L for fire proof heavy duty PVC conduiting for zone 1 and zone 2 cables and control room panel detection cables should be proper wiring and conduiting at site and complete all as specified and directed.make; GB/Supreme/Bharat Note: Supply of copper conductor shall be measured and paid separatly under item No.09 above
Installation,testing and commissioning of flooding system and each by creating artificial smoke/fire in the presence user/CDM and MES representive and resetting the system after testing at site and preparing the test result sheet complete all as specified and directed.
Taking out and dismantling of U/s CO2 Master valve assembly from the cylinder complete all as specified and as directed.
Supply and fixing copper alloy CO2 master valve complete with 24 solenoid and manual release lever from the cylinder and approved ISI std all as specified and as directed.
Refixing of after Repair and cleaning of all dismantling parts of CO2 master valve complete with 24 solenoid and manual release lever and complete all as specified and as directed. Note : serviceable Item obained from item No.11 above shall be utilized under this item
Taking out and dismantling of Unsv / damaged CO2 slave valve complete with pneumatic actuator and manual lever and complete all as specified and as directed.
Supply and fixing copper alloy CO2 slave valve assembly with pneumatic actuator and manual lever from the cylinder and Approved ISI std all as specified and as directed.
M&L for clean agent type cylinder less gas based automatic fire suppression and detection system consists of a heat sensitive tube made of special plastic which is closed by stainless steel fittings and the tube ruptures at 90 to 100 degree temparature for panels & services racks. Clean agent should have self life of 5 years and operational 24/7 without power supply model no. TD300EA ( 100 cm) (contains 750 gms_+" clean gas agent HFC-227ea).Make: ASKA or Equivalent
M&L 10Kg ceiling mounted fire extiguisher clean agent stored pressure guage weight 14.8Kg, empty weight 4.8Kg can height 316MM, diameter 300MM, dischrage time less 10Secs, Auto dischrage mechanism on temperature rise applicable on class A,B,C and electrically started fire, can construcrion: Deep drawn & CO2, mig welded valve construction forging & machining, internal coating of Can: Epoxy coating external coating of can: Epoxy polyster powder coating sheet metal thickness: 2.0MM helium leak detection tested, 5 Years warranty. Make: CEASEFIRE or Equivalent
M&L 10Kg ceiling mounted fire extiguisher clean agent stored pressure guage weight 7.7Kg, empty weight 2.7Kg can height 267MM, diameter 230MM, dischrage time less 10Secs, Auto dischrage mechanism on temperature rise applicable on class A,B,C and electrically started fire, can construcrion: Deep drawn & CO2, mig welded valve construction forging & machining, internal coating of Can: Epoxy coating external coating of can: Epoxy polyster powder coating sheet metal thickness: 1.6MM helium leak detection tested, 5 Years warranty. Make: CEASEFIRE or Equivalent
Sri Surya Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .