| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹33.9 L+₹1.3 L (3.95%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹35.3 L+₹2.8 L (8.45%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
5 Sept 2022, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR MAINT OF SUMMER AND COOLING APPLIANCES REPAIR REWIRING AND FLAME PROOF FITTINGS INTERNAL WIRING AT TECH AREA TAKU AND COMPREHENSIVE MAINT OF CRANE ELECT OPERATED GATE DG SET DAY TO DAY MAINT OF CERTAIN BLDG AT ADMIN AREA TECH AREA CPE ITARSI
2022_MES_544471_1
8917/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
ITARSI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹94,000
Yes
28 Sept 2022
10 Aug 2022
7 Sept 2022
10 Aug 2022
5 Sept 2022
24 Aug 2022
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Repair/ Rewiring of flame proof electric wiring at Tech Area Taku (Restricted Area) :
Taking down existing unserviceable light point wiring, fitting and fixtures and M&L for flame proof point wiring on wall surface wiring on ceiling with necessary fixing arrangements for one light point controlled by one switch with stranded PVC, FRLS insulated and unsheathed copper multistranded conductor of size 2.5 sqmm, 1100 volts grade drawn in and including 14 gauge ERW rigid steel conduit (metallic) not less than 20 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc., including PVC-FRLS insulated and unsheathed copper stranded conductor of size 2.5 sqmm, 1100 volts grade for continuous earthing making good the distrubed surface either by means of plaster of paris/ putti or distemper/ colour wash with same existing colour surfaces complete all as specified and directed. Note:- (i) Junction box flame proof shall be measured and paid under relavent item. (ii) Earth wire shall be of green colour (iii) Colour code should be maintined
All as per item No.1.20 here in before but for fan point wiring, complete all as specified and directed.
All as per item No.1.20 here in before but two light point controlled by one flame proof switch, complete all as specified and directed.
All as per item No.1.20 here in before but power point wiring using 4 sqmm copper conductor cable and 4.0 sqmm as earth wire, complete all as specified and directed.
M&L for sub main wiring with two single core 4 sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable, including ERW rigid metallic steel conduit medium grade, ISI marked, 19/20 mm dia for sub main wiring including 4.0 sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/ recess with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc and making good to the disturbed surfaces to match the existing surfaces complete including taking down existing unserviceable sub main wiring complete all as specified and directed. Note:- (i) three runs of 4 sqmm copper conductor cable, and one run of ERW rigid metallic conduit will be measured as one unit.
S&F flame proof junction box with spigotted cover in LM-6, three way/terminal block 4 way strip type cable entry, 20 mm dia hole aluminium constructed, internal dimension 80 mm dia and 40 mm depth, duly approved by CMRI Dhanbad complete including taking down existing unserviceable junction boxes of any type and size complete all as specified and directed.
S&F flame proof bend any radius of CI/MS with brass nickle threaded of size 20mm complete including taking down existing unserviceable flame proof bend of any type and size complete all as specified and directed.
S&F flame proof union brass of size 20 mm complete including taking down existing unserviceable flame proof union brass of any type and size complete all as specified and directed, incl taking out old unsv complete all as specified and directed.
S&F flame proof plug brass of size 20 mm complete including taking down existing unserviceable flame proof plug brass of any type and size complete all as specified and directed, incl taking out old unsv complete all as specified and directed.
S&F flame proof flexible metalic hose conduit of size 3/4" dia and 300 mm long suitable for explosive atmosphere with explosive dustproof complete including taking down existing unserviceable metallic hose conduit of any type and size complete all as specified and directed.
S&F flame proof rotary switch in LM6, 10/16 amps, single pole, 250 volts and enclosed cast aluminium body with threaded cover with switch operated by a sigle pole knob with double entries suitable for 20 mm dia ERW threaded steel conduit duly approved by CMRI dhanbad and as manufacturers intructions including taking down existing unserviceable rotary switches of any type and size complete all as specified and directed.
S&F flame proof switch socket outlet with plug combination in LM-6, 16 Amps, 250 Volts, two pin and earth with no spare plug complete all as per manufacturer's instruction complete including taking down existing unserviceable switch sockets of any type and size complete all as specified and directed.
S&F flame proof LED light fitting 2X20 Watts, epoxy finish LM6 aluminium housing with heat resistant tubular glass cover held in two aluminium cups, with built-in control gear accessories, prewired including complete including taking down existing unserviceable light fittings complete all as specified and directed.
S&F flame proof Bulk head flat type glass fittings, 30 Watts LED ceiling/wall mounted complete including taking down existing unserviceable bulk head fittings of any type and size all as specified and directed.
Taking out old well glass light fitting and S&F flame proof well glass light fittings, 30 Watts LED ceiling/wall mounted complete including taking down existing unserviceable bulk head fittings of any type and size complete all as specified and directed.
M&L for rewinding of burnt out copper winding of flame proof ceiling fans of any make, size 1200 mm/1400mm sweep, rewinding with super enamelled copper wire of approved quality of existing gauge and size including necessary insulation with leathoroid sheet varnishing of winding of coil, packing, proper insulation, gasket etc including cleaning the rotor & the stator, overhauling, lubricating with fresh graese, etc and re-hanging the same and testing and commissioning, including taking out old unsv complete all as specified and directed.
All as per item No. 16.00 here in before but flame proof Exhaust fan of any size, complete all as specified and directed.
S&F flame proof ceiling fan regulator etc. including taking down existing unserviceable ceiling fan regulator of any type and size complete all as specified and directed.
S&F flame proof cast iron enclosure distribution board 415 volts, 4 way, TPN with ELCB and MCB suitable for explosive atmosphere with explosive including necessary panel board for required connection from busbar to different outgoing and including making good to the disturbed surfaces of walls, floors etc.complete all as approved by CMRI Dhanbad with following incoming and outgoing controls including taking down existing unserviceable MCBs of any type and size complete all as specified and directed. :- (i) Incoming:- ELCB 4 pole, 415 volts, 63 Amps - 01 No. (ii) Outgoing:- MCB 16 amps - 8 Nos.
S&F flame proof cast iron enclosure Main Switch Rotary Type 63 Amp 4 Pole, 415 Volt with all fixing arrangement and making good to the disturbed surfaces of walls, floors etc complete including taking down existing unserviceable main switches of any type and size complete all as specified and directed.
M&L for Earthing connected with Bldg main Lightining arrestor etc. with galvanised iron earth plate of size 600 x 600 x 6 mm thick burried directly in ground not less than 2.5 mtr below grond level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm connected by GI earth strip of size 32 x 6 mm thick soldered and revetted to earth plate attesters. GI earth strip will be protected by using 50mm bore GI pipe (light grade) earth plate to the including flat iron clamp 25 x 3 mm including bolts, nuts & washers complete. The earthing includes necessary excavation, PCC pit, CI cover with frame duly groted with PCC, watering pipe 20 mm bore, funnel with wire mess etc. all as specified and shown in electrical plate No 3 of SSR Part - I. Note: The unit rate shall also including earth work in any type of soil, PCC 1:3:6, type C1 for chamber, CI cover with frame duly groted with PCC with locking system, funnel with GI watering pipe 20mm dia light grade, GI protection pipe light grade 40mm dia and wire mesh complete all as specified and directed.
M&L for Air termination single pointed aluminium rod 12mm dia, 300mm long fixed on GI Pipe complete including taking down unserviceable air termination point complete all as specified and directed.
M&L GI Pipe 40mm dia medium grade for air termination rod fixing, including fitting supported with GI Flange 40 mm bore, incl taking down unserviceable GI pipe complete all as specified and directed. Note: GI Flange will be measured and paid seperately under relevent item
M&L for GI reducer of size 40x12 mm dia medium grade with threaded type suitable to fit air termination complete all as specified and directed.
M&L for providing cement concrete on roof of type B1 1:2:4 20 mm graded stone aggregate for foundation of GI pipe fo lightning protection /as per existing at site complete all as specified and directed.
Taking down and refixing the old removed Aluminium/GI strip any size on roof/wall incl replacement of 'T' type insulators complete all as specified and directed. Note: 'T' type porcelain insulators shall be measured and paid separately under relevent item
S&F 'T' type heavy duty insulators made of DMC material suitable for supporting 25 x 3 mm / 32 x 6 mm strip on roof or as down conductor on wall/surface including all fixing accessories required complete all as specified and directed.
S&F aluminium strip 25X3.15mm with saddler and drilled holes, nut bolt washers and fixing srewed on wall/ roof etc for roof conductor down conductors on roof/wall run on porcelain insulators between suitable distance including taking down unserviceable aluminum strip complete all as specified and directed. Note :- Necessary nut, bolt and washer for fixing alongwith drilled holes shall be deemed to included in quoated rate.
M&L for GI strip 32x6mm burried in ground/fixing on wall/floors complete with drilled hole alongwith necessary nut, bolt and whasher including taking down unsereviceable G I strip complete all as specified and directed. Note :- Necessary nut, bolt and washer for fixing alongwith drilled holes shall be deemed to included in quoated rate.
Taking out old unsv tube rod and supply and fix in replacement of LED tube rod 20 watt capacity single side connection (for flame proof fitting) complete all as specified and directed.
All as per item No 30.00 but double side connection.
Taking out old static handle discharge copper tube any size, supply and fix static handle discharge copper tube of size 25 mm dia and 600 mm long complete all as specified and directed.
M&L for test point terminal block made of gunmetal or phasphorus bronze of size 75x75x25mm drilled and srewed including 03 Nos 8mm dia 25mm long hexagonal head screwed including taking down old terminal block complete all as specified and directed.
Repair/ Rewiring of internal electric wiring and light fittings at Tech Area Taku (Restricted Area) :
Taking down existing unservicable point wiring, fixtureS&Fittings complete and M&L for light/Fan/Exhaust Point wiring with PVC insulated unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable 1100 Volts grade & 1.5 Sq mm multi stranded copper conductor cable as continuous earth wire drawn in PVC conduit as concealed conduit not less than 19/20 mm dia with all fittings, shunk in MS Pressed steel terminal boxes suitable depth and 1.6mm thick (duly painted with two coat of anti corrosive paint out side and Aluminium paint inside) with top cover 2.8 mm thick Hylem sheet cover for mounting of switches/sockets and fan regulators etc complete all as specified and directed. Note: (i) On RCC roof/ceiling PVC conduit will be carried out by proper fixing with clips (ii) Colour coding should be maintained.
All as per item No. 34.10 above but with socket outlet 5 Amps controlled by one switch on the same board, complete all as specified and directed.
All as per item No. 34.10 above but with One socket outlet 5 Amps controlled by one switch on independent board, complete all as specified and directed.
All as per item No. 34.10 but for call bell point wiring, complete all as specified and directed.
All as per item No. 34.10 above but with 2.5 Sq mm for one 15 Amps socket outlet on independent board and 2.5 Sq mm PVC insulated multisranded copper conductor cable as continuous earth wire complete all as specified and directed.
M&L for Sub main wiring with PVC insulated, unsheathed, multistranded copper condurtor FRLS cable of size 3 runs x 4 Sqmm (Phase, neutral & earth) drawing into PVC conduit complete including taking down existing unservicable sub main wiring and making good the disturbed surfaces of wall/ floor etc complete all as specified and directed.
M&L for Sub main wiring for sub main DB's with PVC insulated, unsheathed, multistranded copper condurctor FRLS cable of size 3 runs x 6 Sqmm (Phase, neutral & earth) drawing into 25mm dia surface PVC conduit complete, including taking down existing unservicable sub main wiring and making good the disturbed surfaces of wall/ floor etc complete all as specified and directed.
S&F for Switch piano flush button type single pole, one way 5 Amps, 240 Volts, complete all as specified and directed.
Taking out old unsv switch and supply and fix Switch piano flush button type single pole, one way 5 Amps, 240 Volts, complete all as specified and directed.
S&F for Socket outlet 5 pin, 5 Amps, 240 volts flush type complete all as specified and directed.
Taking out old unsv socket outlet 5 amps and supply and fix Socket outlet 5 pin, 5 Amps, 240 volts flush type complete all as specified and directed.
S&F bell push piano flush type 6 Amps, 240V complete all as specified and directed.
Supply and fixing calling bell ding dong, AC 230 volts single phase complete all as specified and directed.
S&F Switch Socket combination 2 in 1, 5 Amps flush type, 230 Volts complete all as specified and directed. (with point wirng)
Taking out old unsv switch socket combined and supply and fix Switch Socket combination 2 in 1, 5 Amps flush type, 230 Volts complete all as specified and directed.
S&FSwitch Socket combination, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 Volts complete all as specified and directed. (with point wiring)
Taking out old unsv switch socket combined 15 Amps and supply and fix switch socket combined, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 Volts complete all as specified and directed.
S&F for ceiling rose surface bakelite 3 terminals complete all as specified and directed.
Taking out old unsv modular switch and supply and fix in replacement of existing modular switch single pole, one way 6 Amps, 240 Volts, complete all as specified and directed.
Taking out old unsv modular socket 6 Amps and supply and fix in replacement of existing modular socket 6 pin 6 Amp multi purpose 2 in 1 flush type, 230 Volts complete all as specified and directed.
Taking out old unsv modular socket 6/16 Amps and supply and fix in replacement of existing modular socket 6 pin 5 Amp multi purpose 2 in 1 flush type, 230 Volts complete all as specified and directed.
Taking out old unsv modular switch and supply and fix in replacement of existing modular switch single pole, one way 16 Amps, 240 Volts, complete all as specified and directed.
Taking out old unsv modularFan regulator and supply and fix in replacement of existing modular fan regulator one module 240 Volts, complete all as specified and directed.
Taking out old unsv modular Fan regulator and supply and fix in replacement of existing modular fan regulator two module 240 Volts, complete all as specified and directed.
S&F electronic fan regulator step 5/dimmer type , 250V flush type on the exiting phenolic laminated sheet complete all as specified and directed.
S&F Lamp holder PVC/ Polycarbonate insulated body with back plate for angle/batten fittings incl LED bulb 9 watt complete all as specified and directed. (with point wiring)
Taking out old unsv LED bulb and supply and fix LED bulb 10 watt LED bulb 5 star rating complete all as specified and directed.
Taking down old unsv tube light fitting any type and S&F new generation energy saving, wall mounted LED Tube light batten fittings, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 10 Watt LED 6K (2 ft long ) with LED rod 10 watt, 230 Volts 50 Hz. complete all as specified and directed.
Taking down old unsv tube light fitting any type and S&F new generation energy saving ,wall mounted LED Tube light batten fittings , extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 20 Watt LED 6K (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz. complete all as specified and directed.
Taking out old unsv bulk head fitting any type and S&F LED bulk head luminaries IP65 with opal diffuser 10 watt, 230 Volts complete all as specified and directed.
S&F in replacement of and fabrication bracket made out of GI tubing 25 mm dia, light grade upto 1.2 mtr length, bend to shape suitable for bldg security light fitting with necessary MS clamps, nut, bolt, washers etc and including taking out unserviceable bracket and removing from site of work complete all as specified and as directed.
Supply and fixing in replacement of LED bldg security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F Switch disconnector fuse unit Triple Pole with Neutral link 415 Volts AC, 50 Hz, with HRC Fuse set of three suitable for interior mounting in sheet metal enclosure of capacity 63 Amps including taking down existing unservicable switch fuse unit of any type and size complete all as specified and directed.
All as per item No 67.00 above but capacity 100 Amps, complete all as specified and directed.
S&F for powder coated sheet metal encloser deep drawn DB with plug and socket including installed nutral link adjustable din rail and connecting links one MCB single pole 20 Amps complete including taking down existing unservicable DBs/Plugs, complete all as specified and directed.
S&F sheet metal enclosure MCB TPN distribution board, 4 way, Double door with IP-43 protection single phase 440 Volts, including suitable size copper bus bar and neutral link, fixed flush in wall including taking out old unsv DB and making good disturbed wall/surfaces to match with existing specification, complete all as specified and directed.
S&F sheet metal enclosure MCB SPN distribution board, 8 way, Double door with IP-43 protection single phase 240 Volts, including suitable size copper bus bar and neutral link, fixed flush in wall including taking out old DB's and cutting chases to wall as per site requirement for fixing DB and making good disturbed wall/surfaces to match with existing specification, complete all as specified and directed.
All as per item No 71.00 above but MCB SPN DB 4 way, complete all as specified and directed.
Supply and fix in replacement MCB TPN 'C' series, 240/415 Volts, 50Hz, 63 Amps, suitable for high inrush current loads complete all as directed incl taking out old unsv complete all as specified and directed.
S&F in replacement of MCB SPN, 40 Amps 'C' series, 240 volts complete all as specified and directed.
All as per item No. 74.00 above but with 'C' series MCB DP, 40 amps, complete all as specified and directed.
All as per item No. 74.00 above but with 'C' series MCB SP, 6 to 32 amps, complete all as specified and directed.
S&F in replacement of PVC insulated multistranded aluminium conductor twin core of size 6 sq mm, 1100 Volts grade heavy duty service cable, served with inner sheathing of PVC tape and over all PVC sheathed in service connections complete all as specified and directed.
Comprehensive maint of EOT and Chain pully crain, DG Sets at Tech Area (Restricted Area) and Adm Area (Unrestricted Area):
Comprehensive preventive maint for operationaly fit for HOT Crane 5 ton capacity OH travelling hand operated single girder Make M/s Cranex Ltd located Bldg No 211 of Bofors Shed at Tech area Taku. Servicing routine maint of longitutinal travel/cross travel/ assembly system and checking/ lubricating of gear pully/brake system for proper tightness, checking of housing pulley/hock and lubricaing thereof, hoist steel wire rope for cut abberation, cleaning up all grease/clipping materials for its safe operation, The following minor spare parts if reqd to be replaced i.e gasket, nuts, bolts, washer & Oiling/Greasing, etc,the contractor to apply two coat of painting for complete system and written on SM No, Machine No, Make, Date of installation & Capacity,the rates are deemed to be included in the quoted rate. All other remaining items to be checked if necessary to replace the worm out parts complete time to time for safe and satisfactory run of crane. Spares parts crane will be measured and paid seperatly all as specified and directed. Note :- i) Contractor will carry out comprehensive maint once in a month in addition he will also attend to any type of break down on emergency basis as and when intimated byJE E/M or Engr-in-Charge. (ii) Contractor will ensure serviceability and safty of crane during his each visit by way of maintaining job card duly signed by JE E/M (iii) Contractor to maintain records for replacement of spares parts.
Comprehensive preventive maint for operationaly fit for EOT Crane 7.5 ton capacity make M/s Vishal Cranex (P) Ltd located at Bofors Shed bldg No 211 at Tech area Taku. Preventive maint/servicing and routine maint of the following : longitutinal travel/cross travel for frequent reversing frequent acceleration as well as break, power panel, fuse switches for electric control system limit switches for hoisting lowering trolley.and coupling unit travel track, base plate,Gear wheel/ housing assembly system. Checking/ lubricating servicing setting and testing of gear box assembly/braek pully system for proper tightness. Hoist steel wire rope for cut abberation, cleaning up all grease/clipping materials for its safe operation, setting right and replacement of damaged wiring of electrical system in PVC trolly cable outside cabin & main switches to control panel, inspect/checking, decarbonizing and tightening of electrical connection in total system, setting and tightening the same as per their capacity. The following minor spare parts if reqd to be replaced i.e gasket, nuts, bolts, washer, & Oiling/Greasing etc, the contractor to apply two coat of painting for complete system once in entire contract and written on SM No, Machine No, Make, Date of installation & capacity the rates are deemed to be included in the quoted rate. All other remaining items to be checked if necessary to replace the worm out parts complete time to time for safe and satisfactory run of crane. Spares parts will be measured and paid seperatly. all as specified and directed. Note :- i) Contractor will carry out comprehensive maint once in a month in addition he will also attend to any type of break down on emergency basis as and when intimated byJE E/M or Engr-inCharge. ii) Contractor will ensure serviceability and safty of crane during his each visit by way of maintaining job card duly signed by JE E/M (iii) Contractor to maintain records for replacement of spares parts.
All as per item No 78.00 here in before but HOT Hoist Crane 5 Ton capacity (02 Nos) of bldg No 61, Barrel shed & Eqpt store at Tech area Taku of CPE Itarsi Make M/s Morris SWL Safex. Note;- Each crane shall be measured as one unit (2 crane x 11 month =22 month)
All as per item No 78.00 here in before but HOT Hoist Crane 3 Ton capacity (03 Nos) of bldg No 64 Barrel cleaning shed and main shed and Bldg No 69 at Tech area Taku of CPE Itarsi Make M/s Morris SWL Reva. Note;- Each crane shall be measured as one unit (3 crane x 11 month =33 month)
S&F Gear Pully complete set of ISI marked suitable for EOT Crane 7.5 Ton Capacity complete all as specified and directed.
S&F Gear Pully complete set of ISI marked suitable for HOT Hoist Crane of capasity 5 Ton Capacity complete all as specified and directed.
S&F Gear Pully complete set of ISI marked suitable for HOT Hoist Crane of capasity 3 Ton Capacity complete all as specified and directed.
S&F Bearing set of ISI marked suitable for HOT Hoist Crane of 5 Ton Capacity complete all as specified and directed.
S&F Bearing set of ISI marked suitable for HOT Hoist Crane of 3 Ton Capacity complete all as specified and directed.
S&F Bearing set of ISI marked suitable for EOT Crane 7.5 Ton Capacity all as specified and directed.
M&L for removing/servicing/rewinding and refixing the Motor for EOT Crane 7.5 Ton capacity complete all as specified and directed.
M&L for removing/servicing/rewinding and refixing the Motor for HOT Hoist Crane 5 Ton capacity complete all as specified and directed.
M&L for removing/servicing/rewinding and refixing the Motor for HOT Hoist Crane 3 Ton capacity complete all as specified and directed.
M&L for Limit switches of existing make HOT Hoist Crane 5 Ton capacity complete all as specified and directed.
M&L for Limit switches of existing make HOT Hoist Crane 3 Ton capacity complete all as specified and directed.
M&L for Limit switches of existing make EOT Crane 7.5 Ton capacity complete all as specified and directed.
M&L for PVC Trolly Cable (Copper conductor 4core 10 Sqmm) EOT/HOT Hoist Crane 3 to 7.5 Ton capacity including cable trolly accessories complete all as specified and directed.
M&L for replace existing damaged Gear wheel for full set EOT 7.5 Ton capacity complete all as specified and directed.
M&L for replace existing damaged Gear wheel for full set HOT Hoist Crane 3 Ton capacity complete all as specified and directed.
M&L for Push button set HOT Hoist Crane 3/5 Ton capacity complete all as specified and directed.
M&L for Push button set EOT Crane 7.5 Ton capacity complete all as specified and directed.
M&L for replace the damaged base plate of HOT Hoist Crane 3/5 Ton capacity complete all as specified and directed.
M&L for replace the damaged base plate of EOT Crane 7.5 Ton capacity complete all as specified and directed.
Supply & replace hoist steel wire rope 10 mm dia for 3 to 7.5 Ton capacity Hoist/ EOT/HOT Crane complete all as specified and directed.
M&L for replace the damaged fuse switches for 3 Ton cap of HOT Hoist Crane & EOT Crane complete all as specified and directed.
M&L for replace the damaged fuse switches for 5 Ton cap of HOT Hoist Crane & EOT Crane complete all as specified and directed.
M&L for replace the damaged fuse switches for 7.5 Ton cap of HOT Hoist Crane & EOT Crane complete all as specified and directed.
Comprehensive preventive maint for operationaly fit to run DG set 82.5 KVA , three phase , 415 volt, 50 HZ , AC supply alternator of Kirloskar make coupled with diesel engine set, at Proof House Tech Area Taku CPE Itarsi by Servicing and routine maint of the following:- checking/ lubricating system, toping up of lubricant of its desired level, replacement of gasket insulation paper sheet glass sleeve of connecting leads, nuts, bolts and washers, split pins for proper tightness, cleaning up all filter, if reqd to be replace Air filter, fuel filter, Oil filter,grease/clipping materials for its safe operation, cleaning the startor, excitor coil and cleaning the complete assemblies by taking out perished glass sleeve, insulation paper,binding cloth and washing with carbon tetra chloride, decarbonising and cleaning the rotor The following minor spare parts if reqd to be replaced i.e gasket, nuts, bolts, washer, Rod push, clamp hose, control safety, control vernier Oiling/Greasing etc, All other remaining items to be checked if necessary to replace the worm out parts complete time to time for safe and satisfactory run of DG Set. Note :- (i) Spares for DG Set/Alternator will be measured and paid seperatly. ( ii) Contractor will carry out comprehensive maint once in a month in addition he will also attend to any type of break down on emergency basis as and when intimated by JE E/M or Engr-in Charge. (iii) Contractor will ensure serviceability and safty of system complete all as specified and directed.
All as per item No 105.00 but capacity 62.5 KVA at main sub station Adm Area CPE, Itarsi, complete all as specified and directed.
All as per item No 105.00 but capacity 30 KVA at Pump House No 1 Adm Area CPE Itarsi, complete all as specified and directed.
Supply only diesel filter with O ring suitable for following capacities of DG sets :-
(a) D. G . Set 82.5 KVA Proof House Tech Area Taku CPE Itasri
(b) D. G . Set 62.5 KVA Main sub station CPE itarsi
(c) D. G . Set 30 KVA PH No 1 Adm Area CPE Itarsi
Supply only Engine oil filter element with O ring suitable for following capacities of DG sets:-
(a) D. G . Set 82.5 KVA Proof House Tech Area Taku CPE Itasri
(b) D. G . Set 62.5 KVA Main sub station CPE itarsi
(c) D. G . Set 30 KVA PH No 1 Adm Area CPE Itarsi
Supply and and fixing in replacement of Air filter element suitable for following cap of DG sets:-
(a) D. G . Set 82.5 KVA Proof House Tech Area Taku CPE Itasri
(b) D. G . Set 62.5 KVA Main sub station CPE itarsi
(c) D. G . Set 30 KVA PH No 1 Adm Area CPE Itarsi
Supply only by pass filter element with O ring suitable for following capacities of DG sets:-
(a) D. G . Set 82.5 KVA Proof House Tech Area Taku CPE Itasri
(b) D. G . Set 62.5 KVA Main sub station CPE itarsi
(c) D. G . Set 30 KVA PH No 1 Adm Area CPE Itarsi
Supply and fixing in replacement V belt suitable for following capacities of DG sets
(a) D. G . Set 82.5 KVA Proof House Tech Area Taku CPE Itasri
(b) D. G . Set 62.5 KVA Main sub station CPE itarsi
(c) D. G . Set 30 KVA PH No 1 Adm Area CPE Itarsi
Supply and fixing in replacement rubber hose pipe set with clamps suitable for following capacities of DG sets:-
(a) D. G . Set 82.5 KVA Proof House Tech Area Taku CPE Itasri
(b) D. G . Set 62.5 KVA Main sub station CPE itarsi
(c) D. G . Set 30 KVA PH No 1 Adm Area CPE Itarsi
M&L for disconnecting Fuel Injection Pump (FIP) of DG set of capacity 30 KVA to 82.5 for servicing/calliberation from authorised service centre, and refitting after calliberation including replacement of injector nozzle, delivery valvs, gaskit, fuel pump gear, flange assembly, plunger, copper washer, adaptor, set both etc. as required to make the FIP serviceable, complete all as specified and directed. Note : Any additional Spare Parts required shall to be measured and paid seperately as Supply only under relevant Item.
(a) Supply only Main Shaft as per sample
(b) Supply only Tachno Shaft as per sample
(c ) Supply only Weight Carrier as per sample
(d) Supply only Governer Barrel Plunger as per sample
(e) Supply only MVS Plunger as per sample
(f) Supply only Gasket Sets as per sample
(g) Supply only Damper assembly as per sample
Dismantling/taking down radiator assembly for repair/servicing of DG set of following capacity and carry out complete internal cleaning, brazzing to tubing and rectification of leakage and refitting including replacement of minor spare parts like inlet/outlet rubber hose with MS clamps, pipe for thermostate to radiator washer, nut, bolts complete all as specified and directed.
(a) D. G . Set 82.5 KVA Proof House Tech Area Taku CPE Itasri
(b) D. G . Set 62.5 KVA Main sub station CPE itarsi
(c) D. G . Set 30 KVA PH No 1 Adm Area CPE Itarsi
Repair/ servicing of self starter 12 volts DC complete with and including replacement burnt/UNSV spare parts, clutch assembly, carbon brush, solenoid switch, plunger, armature and refixing for DG set 30 to 82.5 KVA, complete all as specified and directed.
Dismantling/repair/over hauling of charging alternator of DG set having capacity of 30 to 82.5 KVA and replacement of UNSV/defective parts like carbon brushes, bearing, leaver, pulley, spacer, commutator assembly, armature, washer etc. and refitting after repair, complete all as specified and directed.
Supply and fixing in replacement of diode and rectifier for alternator suitable for DG set 30 to 82.5 KVA complete all as specified and directed.
Supply and fix in replacement maintenance free heavy duty battery 100 AH, complete all as specified and directed.
Supply and filling in sump / topping up engine oil, multi grade 20w /40w in engine or replacement of engine oil, complete all as specified and directed.
Supply and topping up coolant to the existing radiator for the generating set 30 to 82.5 KVA, complete all as specified and directed.
M&L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc for DG Set of capacity 30 KVA to 82.5 KVA DG Set complete all as specified and directed.
Replacement of defective/unserviceable automatic Voltage Regulator(AVR) suitable for 30 KVA DG Set to 82.5 KVA DG Set complete all as specifed and directed.
Supply and fix in replacement battery leads set with thimble, PVC insulated multisranded, copper conductor 6 Sqmm not less than 1.5 mtr long each duly fixed with brass clamps, copper lugs suitable for 30 KVA DG Set to 82.5 KVA DG Set, complete all as specified and directed.
Supply and filling electrolyte of suitable Sp gravity for lead acid batteries in sealed container complete all as specified and directed.
Supply and fixing in replacement high pressure fuel pipe steel braded with benzo bolts, clamp and spring washer etc complete all as specified and directed.
Supply and fixing in replacement of battery charger heavy duty, 100 AH, 12 volts with lead ,volt/Amp meter, complete all as specified and directed.
Repair/maint of Summer Appliances at Tech Area Taku (Restricted Area) :
Taking down carefully AC ceiling fan 1200mm/1400mm sweep, exhaust fan 300mm to 450mm sweep and wall moundted bracket fan 300/450mm sweep from their position complete for servicing such as removing dust and dirt from fan motor, washing blades with detergent powder including greasing to bearing, checking & replacing worn out screws with spring washers, rubber befit washers of fan blades, fan motor body, spilt pin/screw for fan down rod/check nuts as required for different makes of ceiling/exhaust fans to put fans fans to smooth and satisfactory working and refixing ceiling fan/exhaust fan after executing necessary servicing to their position connecting to electric system with suitable size of cable and testing, complete all as specified & directed. Note : Rates quoted by contractor shall deemed to be inclusive all minor items and no extra payment shall be admissible except for the items which are to be replaced which shall be measured and paid separately under respective item of Schedule 'A'.
Material & labour for preparation of old painted surfaces of ceiling fan, exhaust fan & wall mounting fan by scrubbing, cleaning with sand paper/wire brush etc making good surfaces and painting by applying synthetic enamelled first quality paint using spray gun in situ including filling cavities with filler and marking Srl No SM No / MES No with black paint, complete all as specified and directed.
Material and labour for rewinding of AC ceiling fan, 230 volts, 50 Hz, 1200mm/1400mm sweep of any make with appropriate gauge super enamelled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified & directed.
Material and labour for rewinding of exhaust fan/wall mounted fan, 230 volts, 50 Hz, 300/450mm sweep of any make with appropriate gauge super enamelled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified & directed.
Supply & fixing ball bearing 6202/6203 in replacement suitable for AC ceiling fan of 1200/1400mm sweep/ exhaust fan/ air circulation fan of any make to replace the unserviceable bearing including greasing as required, complete all as specified & directed.
Supply & fixing in replacement capacitor, 4/5 mfd 230 volts, AC, 50 Hz, complete all as specified & directed.
Supply & fixing in replacement capacitor, 2.5 mfd 230 volts, AC, 50 Hz, complete all as specified & directed.
Supply and fix in repair of split pin with hook , rubber and nut bolt of suitable for ceiling fan/exhaust fan of any sweep and make complete all as specified and directed.
Supply and fix in repair of shaft of approved quality for ceiling fan/exhaust fan any make, type and size complete all as specified and directed.
Supply and fix in repair of self lubricating bush of gun metal as per ceiling fan/exhaust fan complete all as specified and directed.
Supply & fixing in replacement fan canopy, complete all as specified and directed.
Supply and fix repair and replacement of hanging rod 1ft/2 ft complete all as specified and directed
Supply and fix in repair and replacement of fan blade 1200/1400 mm complete all as specified and directed
S&F in repair of Electronic step type Fan regulator (mini switch dimmer) 120/280 watt capacity including connecting up complete all as specified and directed.
Supply and fix in repair of PVC insulated, unsheathed three core copper flexible cable of size 1.5 sqmm including connection complete all as specified and directed.
Taking down carefully Geyser of capacity 25/35 ltrs from its position for repair/servicing such as removal of dust, checking, replacing worn out parts, rubber etc, re-assembling at its position after repair, testing & commissioning & connecting to electric system with suitable size cable, complete all as specified & directed. Note : Rates quoted by contractor shall deemed to be inclusive all minor items and no extra payment shall be admissible except for the items which are to be replaced which shall be measured and paid separately under respective item of Schedule 'A'.
Supply & fixing galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., , fixed complete to walls and ceilings or laid in floors, complete including taking down all as specified and directed.
Supply & fixing galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., , fixed complete to walls and ceilings or laid in floors, complete including taking down all as specified and directed.
Supply & fixing geyser tank of capacity 25 ltrs, complete all as specified & directed.
Supply & fixing geyser tank of capacity 35 ltrs, complete all as specified & directed.
Supply & fixing heating element for geyser, 1500 watt, round type, complete all as specified & directed.
Supply & fixing heating element for geyser, 2000 watt, round type, complete all as specified & directed.
Supply & fixing heating element for geyser, 1500 watt, triangle type, complete all as specified & directed.
Supply & fixing heating element for geyser, 2000 watt, triangle type, complete all as specified & directed.
Supply & fixing thermostat suitable for geyser of any capacity, complete all as specified & directed.
Supply & fixing Angle stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., fixed in repair, complete all as specifed & directed.
Supply & fixing Bib tap, 15mm bore, fancy type, chromium plated , cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, fixed in repair, complete all as specified & directed.
Supply & fixing Stainless steel connection 15mm dia, 900mm long with brass CP nuts and washers at both ends for hot water & Cold Water , fixed in repair, complete all as specified & directed.
Taking down/out Deep freezer/Refrigerator transporting to contractor's workshop for carrying out repairs, taking out assembly, welding/brazing after detecting the leakage, as mentioned in respective items of Schedule including transporting back after repair, re-fixing at site, making it functional after replacement of worn out nuts, bolts, washer etc. including re-connecting electrical connection and testing, complete all as specified & directed. Note :- Cost of material and labour for providing new items shall be measured and paid for separately under relevant items of Sch 'A'.
Taking down/out Water Cooler of 40/80 ltrs and 60/120 ltr capacity , transporting to approved workshop for carrying out repairs, taking out assembly, welding/brazing after detecting the leakage, as mentioned in respective items of Schedule including transporting back after repair, refixing at site, making it functional after replacement of worn out nuts, bolts, washer etc. including re-connecting electrical connection testing complete all as specified & directed. Note :- Cost of material and labour for providing new items shall be measured and paid for separately under relevant items of Sch 'A'.
Material & labour for preparation of old painted surfaces by scrubbing, cleaning with sand paper/wire brush etc making good surfaces and repainting by applying two coats of synthetic enamelled first quality paint using spray gun over over one coat of red oxide zinc chrome primer and marking Srl No SM No / MES No with black paint of Deep Freezer/Refrigerator/water cooler of capacity up to 320 Litres, complete all as specified & directed.
Supply and fixing in replacement of following unserviceable items of Deep freezer/refrigerator of 300/310/320 litres as required at site including testing of the same, complete all as specified & directed :-
(a) MS condensing coil with fixing arrangement for 300/310/320 litres capacity complete with gas charging.
(b) Over load protector.
(c ) Thermostat switch (Auto defrost).
(d) Temp control knob with defrost push button.
(e) Electrical lamp pin/threaded type 15 watt, 240 volts AC supply.
(f) PVC ice tray of superior quality.
(g) Relay as per existing.
Supply, fixing and testing new compressor, single phase, 240 Volts, AC supply in replacement including cost of rubber bushes, bolts, nuts washers, copper tubing capillary tube, dryer filter terminal cover, thimbles, electrical wiring oil and gas charging (R-134 or as recommended by manufacture) and testing complete for the following including transportation etc :-
(a) Compressor of Deep freezer/Refrigerator of cap 300/310 Ltr.
(b) Compressor of Water Cooler of capacaity 40/80, 60/120 Litres.
Supply and fixing in replacement of following unserviceable items by opening of water cooler of 40/80 or 60/120 Ltrs capacity frost free for following replacement of unserviceable accessories and refixing, connecting and testing complete all as specified & directed :-
(a) Copper Condensing coil complete with fixing arrangement.
(b) Fan motor 1/2 HP, 240 volts, single phase AC supply.
(c ) Aluminium Blade for fan motor complete blower.
(d) Thermostat.
(e) Relay as per existing make.
(f) Over load protector.
(g) Float Valve brass 15 MM bore.
(h) Push type tap 15mm bore, brass chromium plated
Supply and filling/charging of following water collers/Deepfreezer with refrigerant R-22A/134 or as recommended by manufacturer including flushing out oil, vacuming, top up oil, brazing, leak detection, testing etc for following cooling appliances including replacement of capillary tube and dryer filter :- Note:-. The type of refrigerant gas shall be charged as per manufacturer recommendation.
(a) Water cooler 60/120 litres capacity.
(b) Deep Freezer/Refrigerator of capacity up to 320 Litres.
Supply and fixing in repair of blower motor, 230 volts, single phase, 50 Hz, suitable for desert cooler /Exhaust fan size 350/450 mm as per site requirement including kit consists of mounting clamps, blades, speed contol switch, nut, bolts and washers complete all as specified and directed.
Supply & fix in replacement of exhaust fan louver of any size complete all as specified and directed
Supply and Replacement/repair of voltage stabilizer of capacity 5 KVA installing and testing complete all as specified and directed.
Taking down defective Split/Window AC of 1.5 Ton capacity from any height and any places for repair and refixing at its original place after replacement of defective/wornout parts & making serviceable, complete all as specified & directed. Note:- Worn out spares parts required for making AC serviceable/functional shall be measured and paid separately under appropriate item as 'Supply only'.
(a) Supply only fan motor for 1.5 ton AC.
(b) Supply only AC compressor for 1.5 ton AC.
(c ) Supply and charging gas 22 R for 1.5 ton AC.
(d) Supply only AC copper pipe of size 8mm and 15 mm for 1.5 ton AC.
(e) Supply only 45 Mfd capacitor for 1.5 ton AC. Make.
(f) Supply only contactor, single phase, 30 Amp for 1.5 ton AC.
(g) Supply only fan belt for 1.5 Ton AC.
(h) Supply only printed circuit board of split AC/Window AC 1.5 ton
(j) Over load protector.
Maintenance for operationaly fit of RO based aqua guard installed for water cooler, with replacement of candle, Replacement of Membrane, Replacement of Pree filter candle, Replacement of Diaphragm Pump 24 volt DC and open flow minimum 2.0 Ltr/min checking of AC supply circuitary of aqua guard and made functional, replacement of step down transformer 230 volt to 12/24 volts, as per sample, incl servicig of RO complete all as specified and directed.
Dismantling and refixing the complete unit with new solar water heater plate (set of 5) of capacity 500 LPD installed at various sites complete all serviceable accessories including repairing/replacing all defective parts such as water tank, nuts, bolts, washers, drain plug, cleaning tanks, defective tubes and all other minor accessories as required at site including painting the solar water heater by rubbing the old paint and applying with two coats of synthetic enameled paint by spray painting where necessary and testing the same after repair complete all as specified and directed. Note:- Replacement of parts shall be measured and paid under item 190.00 here in after.
Supply & fixing the following items/spares in replacement for solar heaters of various capacities as mentioned in Srl No 168.00 here-in-before all as specified :-
(a) Heating element of capacity upto 2 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½” complete all as specified.
(b) Heating element of capacity upto 1.5 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½” complete all as specified.
(c) Glycol (Anti freezing solution) for filling in copper tubes complete all as specified.
(c ) Dead flange with nut, bolts and washers complete all as specified.
(d) Float valve assembly 15mm dia complete all as specified.
(e) Thermostat suitable for solar heater complete all as specified
(f) Hot water steel tank non stick 2mm thick with ceramic lining of capacity 500 Ltrs each including making necessary connections complete all as specified.
Petty repair and Day to day maint of certain bldgs at Tech Area Tahu (Restricted Area) :
S&F in repair 15mm dia PTMT bib taps screwed down screwed for iron pipe fixed in reps complete all as specified and directed.
S&F in repair bib taps 15mm dia chromium plated fancy type with capstan head screwed down screwed for iron pipe or for brass ferrule and fixed in reps complete all as specified and directed.
S&F in repair Pillar taps fancy type 15mm of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-110gms), complete all as specified and directed.
S&F in repair 15 mm pillar taps fancy type cast copper alloy with capstan heads, chromium plated, screed down high pressure, with or without lettered 'Hot; or 'cold' with long screwed shanks and fly nut, screwed for iron pipe and fixed, complete all as specified and directed.
S&F in repairs 15 mm dia Angle/stop cock cast copper alloy, fancy type chromium plated screwed down high pressure, complete all as specified and directed.
S&F in repair 15mm bore concealed stop valve fancy type chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for unions pipe complete all as specified and directed.
S&F in repair 15mm bore dia of pipe ball brass valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed.
S&F PVC connections 15mm dia and 450mm long with PTMT nuts complete all as specified and directed.
S&F PVC connections 15mm dia and 600mm long with PTMT nuts complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 Ltr capacity valveless symphonic action type white as approved with ball valve flat back & handle including brackets and flush pipe of polyethylene of low or high density or PVC 32mm dia, for low level cistern complete all as specified and directed.
S&F in repair plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S&F in repair CP brass jet spray (health faucet) with flexible pipe 1.50m long fixed to EWC and bib tap suitable for 15mm bore of pipe complete all as specified and directed.
S&F in repairs Wash basins, vitreou china (flat back or angle back type) size 550x400mm white , incl cutting for & pinning in ends of brackets or erecting stand, brackets, CP brass waste coupling and waste pipe of standard length complete all as specified and directed.
S&F in repair PVC bath cabinet with mirror 350x450mm, complete all as specified and directed.
S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard bard railing 60 cm long complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections incl cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections incl cleaning for refixing or removal to store all as specified and directed.
Refixing 15mm dia steel tubing and connection in new or old position (in wall ceiling floors etc) all as specified and directed.
Refixing 20mm dia steel tubing and connection in new or old position (in wall ceiling floors etc) all as specified and directed.
S&F 15mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in flors complete all as specified and directed.
S&F 20mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
M&L cleaning and removing all scale and dirt etc. from tanks and from mounts of circulating pipes etc. capacity of tanks exc. 250 Ltr and nexc. 500 ltr complete all as specified and directed. Note : Any damage to float valve, pipe etc shall be make good by the contractor.
All as per items 192.00 above but capacity of tanks exc. 500 ltr and nexc. 1000 Ltr complete all as specified and directed.
S&F in repairs rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylindrical Vertical with closed top) (three layered, ISI marked) hoisted and fixed in position all as specified including 20mm dia float valve and dismantling of existing tank complete all as specified and directed.
S&F in repairs rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylindrical Vertical with closed top) (three layered, ISI marked) hoisted and fixed in position all as specified complete including 20mm dia float valve and dismantling of existing tank complete all as specified and directed.
S&F 21-22 inch dia galvanised mild steel pan mortar (Tasla/ghamela) not less than 1mm thick with for 04 Nos bolt of 5-6mm dia with 4 Nos nut bolt with 4 Nos washer including fixing on water storage tank as tank cover complete all as specified and directed.
S&F in repair 15mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe screwed for iron pipe and fixed. (Minimum and fixed. (Minimum weight 15mm-142gms) complete all as specified and directed
S&F in repair 15 mm nipple suitable for HDPE water tanks including necessary driling holes etc fixed complete all as specified and directed.
S&F in repair 20 mm nipple suitable for HDPE water tanks including necessary driling holes etc fixed complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description not exc 1.00 sqm each, complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description exc 1.00 sqm and not exc 2.00 sqm each, complete all as specified and directed.
S&F in repairs galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinted tacks or galvanised wire staples fixed with wooden beading complete all as specified and directed.
Hacking out old broken glass panes of any thickness description from wooden frame or stone concrete or steel frame,or brick surrounds, glazed with putty or fixed with beads and prepared to receive new glas panes complete all as specified and directed.
S&F 3mm sheet glass ordinary quality and glazing with oil putting in squares nexc 0.50 Sqm each, complete all as specified and directed.
S&F 3mm sheet frosted glass ordinary quality and glazing with oil putting in squares nexc 0.50 Sqm each, complete all as specified and directed.
S&F 3mm thick figured glass sheet fixed with beads or oil putty complete all as specified and directed.
S&F in repars mild steel pressed handles oval type stove enameled black size 100mm, complete all as specified and directed.
S&F in repair butt hinges 100mm size medium weight cold rolled mild steel complete all as specified and directed.
S&F butt hinges 75mm size medium weight cold rolled mild steel complete all as specified and directed.
S&F in repairs mild steel barrel tower bolts, stove enameled black, with bright bolt size 150mm, complete all as specified and directed.
S&F in repairs mild steel barrel tower bolts, stove enameled black, with bright bolt size 100mm, complete all as specified and directed.
S&F in repairs 300mm long M/S sliding door bolt plate type stove enameled black with bright bolt not less then 12mm dia with and incl a minimum of 6 boldts and nuts four or bolt plate and two on staple plate, complete all as specified and directed.
S&F in repairs 150mm floor door stopper of aluminimum alloy body and tongue anodized with hard drawn steel spring, complete all as specified and directed.
S&F in repairs 300mm mild steel ordinary rat tail red pattern spring incl roller plate complete all as specified and directed.
S&F in repairs door closer hydraulicaly regulated, univarsal type, aluminium body, complete all as specified and directed.
S&F in repair Grating doom PTMT 100mm dia ( min. wt. 25 gms) fixed, complete all as specified and directed.
S&F in repair Grating doom PTMT 125mm dia ( min. wt. 40 gms) fixed, complete all as specified and directed.
S&F in repair stainless steel plate rack (utencil rack for kitchen of size 750 x 600 x 250mm and min 0.80 to 1.00 mm thick fixed with stainless steel screw and rawl plug complete all as specified and directed.
S&F in repair Kitchen Sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste coupling/waste pipe; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs kitchen sink waste coupling, including PVC waste pipe complete all as specified & directed.
S&F urinal waste pipe fixed complete all as specified & directed
S&F waste coupling of CP brass (half and full threaded) complete all as specified and directed.
S&F in repairs vitreous china urinal, half stall type, with all necessary fitting complete all as specified & directed.
Dismantling of CI pipe of 75/100mm dia fixed with cement joint, complete all as specified and directed.
Dismantling of AC/PVC pipe 100mm dia fixed with cement joint, complete all as specified and directed.
S&F PVC (SWR) pipes 110mm dia in any length with rubber ring joint fixed to wall complete all as specified and directed.
S&F PVC (SWR) pipes 75mm dia in any length with rubber ring joint fixed to wall complete all as specified and directed.
S&F PVC (SWR) bends 110mm dia, in any radius, complete all as specified and directed.
S&F PVC (SWR) bends 75mm dia, in any radius, complete all as specified and directed.
S&F in repairs brass chroumium plated shower rose 125mm size complete all as specified and directed.
S&F tubular, towel rail brass chromium plated 20mm dia D type 60cm long between flanges complete all as specified and directed.
Demolition of brick work built in cement mortar incl all quions order pillar etc complete all as specified and directed.
M&L for brick work using sub class'B' bricks straight or corved on plan exc 6 mean radius in CM 1:6, complete all as specified and directed.
M&L for brick work except bricks using sub class'B' bricks straight or corved on plan exc 6 mean radius in CM 1:6, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, complete all as specified and directed.
Taking down cement plaster from wall's/ceiling incl raking out joints hacking for key scrubbing down with water complete all as specified and directed.
M&L15mm thick rendering on fair faces of concrete/ brick surfaces of walls in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L 15mm thick rendering on other than fair faces of concrete brick surfaces of walls in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L 10mm thick rendering on celing in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of wall & applying two coats of oil bound distemper over and including a one coat of birla white putty 1-2mm thick on walls complete all as specified and directed.
M&L for two coats of white wash on new surfaces of ceiling incl preparation of surfaces complete all as specified and directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint (weather proof paint on external surfaces) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces at any height of building / tower complete all as specified and directed.
S&F in repair non skid ceramic tiles coloured 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc over and including screed bed in cement mortar 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed.
S&F in repair glazed ceramic tiles in vertical surface 450x350x7mm thick over and including screed bed in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified and directed.
M&L in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F in repair curtain rails/rod 20mm dia fix in repair, mild steel, chromium plated with fixing brackets, stops, rollers and finnels including designer doom for curtain rod on both end and with all necessary fittings complete all as specified and directed.
Petty repair and Day to day maint of certain bldgs at Adm Area CPE (Unrestricted Area) :
S&F in repair 15mm dia PTMT bib taps screwed down screwed for iron pipe fixed in reps complete all as specified and directed.
S&F in repair bib taps 15mm dia chromium plated fancy type with capstan head screwed down screwed for iron pipe or for brass ferrule and fixed in reps complete all as specified and directed.
S&F in repair Pillar taps fancy type 15mm of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-110gms), complete all as specified and directed.
S&F in repair 15 mm pillar taps fancy type cast copper alloy with capstan heads, chromium plated, screed down high pressure, with or without lettered 'Hot; or 'cold' with long screwed shanks and fly nut, screwed for iron pipe and fixed, complete all as specified and directed.
S&F in repairs 15 mm dia Angle/stop cock cast copper alloy, fancy type chromium plated screwed down high pressure, complete all as specified and directed.
S&F in repair 15mm bore concealed stop valve fancy type chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for unions pipe complete all as specified and directed.
S&F in repair 15mm bore dia of pipe ball brass valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed.
S&F PVC connections 15mm dia and 450mm long with PTMT nuts complete all as specified and directed.
S&F PVC connections 15mm dia and 600mm long with PTMT nuts complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 Ltr capacity valveless symphonic action type white as approved with ball valve flat back & handle including brackets and flush pipe of polyethylene of low or high density or PVC 32mm dia, for low level cistern complete all as specified and directed.
S&F in repair plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S&F in repair CP brass jet spray (health faucet) with flexible pipe 1.50m long fixed to EWC and bib tap suitable for 15mm bore of pipe complete all as specified and directed.
S&F in repairs Wash basins, vitreou china (flat back or angle back type) size 550x400mm white , incl cutting for & pinning in ends of brackets or erecting stand, brackets, CP brass waste coupling and waste pipe of standard length complete all as specified and directed.
S&F in repair PVC bath cabinet with mirror 350x450mm, complete all as specified and directed.
S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard bard railing 60 cm long complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections incl cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections incl cleaning for refixing or removal to store all as specified and directed.
Refixing 15mm dia steel tubing and connection in new or old position (in wall ceiling floors etc) all as specified and directed.
Refixing 20mm dia steel tubing and connection in new or old position (in wall ceiling floors etc) all as specified and directed.
S&F 15mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in flors complete all as specified and directed.
S&F 20mm dia GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
M&L cleaning and removing all scale and dirt etc. from tanks and from mounts of circulating pipes etc. capacity of tanks exc. 250 Ltr and nexc. 500 ltr complete all as specified and directed. Note : Any damage to float valve, pipe etc shall be make good by the contractor.
All as per items 269.00 above but capacity of tanks exc. 500 ltr and nexc. 1000 Ltr complete all as specified and directed.
S&F in repairs rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylindrical Vertical with closed top) (three layered, ISI marked) hoisted and fixed in position all as specified in SSR Part 1 etc complete including 20mm dia float valve and dismantling of existing tank complete all as specified and directed.
S&F in repairs rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylindrical Vertical with closed top) (three layered, ISI marked) hoisted and fixed in position all as specified in SSR Part 1 etc complete including 20mm dia float valve and dismantling of existing tank complete all as specified and directed.
S&F 21-22 inch dia galvanised mild steel pan mortar (Tasla/ghamela) not less than 1mm thick with for 04 Nos bolt of 5-6mm dia with 4 Nos nut bolt with 4 Nos washer including fixing on water storage tank as tank cover complete all as specified and directed.
S&F in repair 15mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe screwed for iron pipe and fixed. (Minimum and fixed. (Minimum weight 15mm-142gms) complete all as specified and directed
S&F in repair 15 mm nipple suitable for HDPE water tanks including necessary driling holes etc fixed complete all as specified and directed.
S&F in repair 20 mm nipple suitable for HDPE water tanks including necessary driling holes etc fixed complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description not exc 1.00 sqm each, complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description exc 1.00 sqm and not exc 2.00 sqm each, complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinted tacks or galvanised wire staples fixed with wooden beading complete all as specified and directed.
Hacking out old broken glass panes of any thickness description from wooden frame or stone concrete or steel frame,or brick surrounds, glazed with putty or fixed with beads and prepared to receive new glas panes complete all as specified and directed.
S&F 3mm sheet glass ordinary quality and glazing with oil putting in squares nexc 0.50 Sqm each, complete all as specified and directed.
S&F 3mm sheet frosted glass ordinary quality and glazing with oil putting in squares nexc 0.50 Sqm each, complete all as specified and directed.
S&F 3mm thick figured glass sheet fixed with beads or oil putty complete all as specified and directed.
S&F in repars mild steel pressed handles oval type stove enameled black size 100mm, complete all as specified and directed.
S&F in repair butt hinges 100mm size medium weight cold rolled mild steel complete all as specified and directed.
S&F butt hinges 75mm size medium weight cold rolled mild steel complete all as specified and directed.
S&F in repairs mild steel barrel tower bolts, stove enameled black, with bright bolt size 150mm, complete all as specified and directed.
S&F in repairs mild steel barrel tower bolts, stove enameled black, with bright bolt size 100mm, complete all as specified and directed.
S&F in repairs 300mm long M/S sliding door bolt plate type stove enameled black with bright bolt not less then 12mm dia with and incl a minimum of 6 boldts and nuts four or bolt plate and two on staple plate, complete all as specified and directed.
S&F in repairs 150mm floor door stopper of aluminimum alloy body and tongue anodized with hard drawn steel spring, complete all as specified and directed.
S&F in repairs 300mm mild steel ordinary rat tail red pattern spring incl roller plate complete all as specified and directed.
S&F in repairs door closer hydraulicaly regulated ,univarsal type, aluminium body, complete all as specified and directed.
S&F in repair Grating doom PTMT 100mm dia ( min. wt. 25 gms) fixed, complete all as specified and directed.
S&F in repair Grating doom PTMT 125mm dia ( min. wt. 40 gms) fixed, complete all as specified and directed.
S&F in repair stainless steel plate rack (utencil rack for kitchen of size 750 x 600 x 250mm and min 0.80 to 1.00 mm thick fixed with stainless steel screw and rawl plug complete all as specified and directed.
S&F in repair Kitchen Sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste coupling/waste pipe; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs kitchen sink waste coupling, including PVC waste pipe complete all as specified & directed.
S&F urinal waste pipe fixed complete all as specified & directed
S&F waste coupling of CP brass (half and full threaded) complete all as specified and directed.
S&F in repairs vitreous china urinal, half stall type, with all necessary fitting complete all as specified & directed.
Dismantling of CI pipe of 75/100mm dia fixed with cement joint, complete all as specified and directed.
Dismantling of AC/PVC pipe 100mm dia fixed with cement joint, complete all as specified and directed.
S&F PVC (SWR) pipes 110mm dia in any length with rubber ring joint fixed to wall complete all as specified and directed.
S&F PVC (SWR) pipes 75mm dia in any length with rubber ring joint fixed to wall complete all as specified and directed.
S&F PVC (SWR) bends 110mm dia, in any radius, complete all as specified and directed.
S&F PVC (SWR) bends 75mm dia, in any radius, complete all as specified and directed.
S&F in repairs brass chroumium plated shower rose 125mm size complete all as specified and directed.
S&F tubular, towel rail brass chromium plated 20mm dia D type 60cm long between flanges complete all as specified and directed.
Demolition of brick work built in cement mortar incl all quions order pillar etc complete all as specified and directed.
M&L for brick work using sub class'B' bricks straight or corved on plan exc 6 mean radius in CM 1:6, complete all as specified and directed.
M&L for brick work except bricks using sub class'B' bricks straight or corved on plan exc 6 mean radius in CM 1:6, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, complete all as specified and directed.
Taking down cement plaster from wall's/ceiling incl raking out joints hacking for key scrubbing down with water complete all as specified and directed.
M&L15mm thick rendering on fair faces of concrete/ brick surfaces of walls in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L 15mm thick rendering on other than fair faces of concrete brick surfaces of walls in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L 10mm thick rendering on celing in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of wall & applying two coats of oil bound distemper over a one coat of birla white putty 1-2mm thick on walls complete all as specified and directed.
M&L for two coats of white wash on new surfaces of ceiling incl preparation of surfaces complete all as specified and directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint (weather proof paint on external surfaces) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces at any height of building / tower complete all as specified and directed.
S&F in repair non skid ceramic tiles coloured 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc over and including screed bed in cement mortar 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed.
S&F in repair glazed ceramic tiles in vertical surface 450x350x7mm thick over and including screed bed in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified and directed.
M&L in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F in repair curtain rails/rod 20mm dia fix in repair , mild steel, chromium plated with fixing brackets, stops, rollers and finnels including designer doom for curtain rod on both end and with all necessary fittings complete all as specified and directed.
Schedule of credit (calculation will be done off line) Rs. 115982.00
TANUJ CONST. CO.
M/s Prayag Construction
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .