Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹36.9 L+₹2.8 L (8.13%)Rejected-Finance PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance Highest amount quoted |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2022_MES_530453_2
8437/E8
Open Tender
Civil Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D a(i) and a (ii)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹94,000
Yes
12 Aug 2022
14 Jun 2022
29 Jul 2022
14 Jun 2022
27 Jul 2022
1 Jul 2022
14 Jun 2022 - 21 Jun 2022
Amount
Demolition of cement concrete of any description in any position, concrete filling in sunken floor complete all as specified.
M & L PCC 1:7:12 type F 2 with bricks course aggregate as in filling of sunken slab after laying carrying out required tests for CI pipes joints WPT complete all as specified.
Roughening surfaces of old concrete floor by picking, sweepping clean and washing down with water to remove dust etc complete all as specified.
M&L for 15mm thick rendering to sides and bottom of sunken slab in CM 1:3 with water proofing compound, finishing the surfaces even and smooth without using extra cement. Note :- WPC shall be measured & paid seperately.
M&L 40mm thick cement concrete type B-0 using 12.5 mm graded stone aggregate in sunken floors finished even and fair complete all as specified.
S&F in repairs GI spouts 50mm bore medium grade, projecting at least 10 cm clear of the wall complete all as specified and directed.
M & L for applying two coats of hot bitumen 85/25 grade @ 1.70 Kg/Sqm over vertical surfaces and floor of sunken slab after laying all CI connection branch pieces etc after covering joints with and including PCC (1:2:4) mixed with WPC complete all as specified and directed.
M & L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified & applying two coats of aluminium paint.
M&L for preparation of surface including cleaning, drying and removing all oil, grease, dust etc and priming the surface with a coat of Dr. Fixit primeseal apply at the rate of 8-10 Sqm/Ltr and applying two coats of Dr. Fixit Hydroshield PUD plus by brush or roller to achieve a total depth of 0.8 - 1mm with coverage of approximately 0.60Litre/Sqm per coat. including filling the gap between roof tiles with creck filler properly. Note : (i) The contents of Dr. Fixit Hydroshield PUD plus shall be thoroughly stirred for at least 2 - 3 minutes using a slow speed (300-400 RPM) drill machine attached with a mixing paddle. Do not dilute with water. Keep on stirring during application. (ii) All joints corners/drainage outlets and penetration points shall be treated prior to all application of Dr. Fixit Hydroshield PUD plus. All corners, gaps, joints, protrusions and outlets should be coated with an extra coat incorporating reinforcing fabric. (iii) Allow complete drying between coats with a minimum 3 to 4 hours depending on the weather conditions.
M & L for 40 mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in floor finished even and smooth without using extra cement complete all as specified and directed.
Dismantling floor,hearth or wall tilling including cement mortar bedding ( but not backing), and rubbish off the premises complete all as specified.
M & L non skid ceramic coloured tiles 7 to 8 mm thick (square rectangular ) area of each tile exc 0.11 sqm but nexc 0.18 sqm,in floors/skirting laid over & including 15 mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white cement to match.
M & L non skid ceramic coloured tiles 7 to 8 mm thick (square rectangular ) area of each tile exc 0.18 sqm but nexc 0.36 sqm,in floors/skirting laid over & including 15 mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white cement to match
M & L glazed ceramic coloured & digital tiles 350 x 250 x 7/450x350/7 mm thick on vertical surfaces of wall set and jointed in neat cement slurry and pointed in white/coloured cement to match shade of tiles over and including 10mm thick rendering in CM 1:4 complete all as specifed and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection finished even and fair incl expansion joint at every 3.0m interval and every corner complete all as specified and directed.
Demolition of brick masonary built in cement mortar all as specified.
M & L brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cm (1:6) all as specified.
Same all as Item Srl No 17 above but except bricks.
Taking down cement plaster from brick walls including racking out joints hacking for keys scrubbing down with water etc complete all as specified.
M&L for Rendering 15 mm thick on brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified & directed.
M&L for Rendering 15mm thick on brick work or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified & directed.
M & L preparing surface of newly plastered walls and applying two coats of oil bond distemper over chalk whitening preparatory to distempering.
M & L preparing surface of old plastered walls and applying two coats of oil bond distemper over chalk whitening preparatory to distempering.
M&L Preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer.
M&L 3mm thick wallcare putty on wall complete.
Taking down chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frame) & removing from site complete all as specified and directed.
Taking down shutters of any description but exc 1 Sqm each and not exc 2 Sqm each.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frame) & removing from site complete all as specified and directed.
S&F 2nd class teak HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed.
S & F factory made 35 mm thick, 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain, chamferd or rounded, fitted with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Part-I Section 8 Clause 8.24(a), etc complete all as directed by Engineer-in-Charge.
S & F factory made 35 mm thick, plain framed panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part - I), kiln seasoned and chemically pressure treated.
S&F factory made soild PVC door frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet reinforced with mild steel square tube and edges will be painted to match with single side prelam sheet as per specification and drawing given on MES schedule Part-II (2010) complete all as specified and directed.
S & F Factory made solid PVC moulded door shutter with wood free EPS, 28 to 30 mm thick ( stiles ), with 2, 4 or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specifications and drawings.
S&F (factory made) steel windows with side hung shutters including projecting type hinges with lugs steel handles and steel peg stays, with glazing bars, devetailed or welded complete all as specified and directed.
S&F (factory made) steel windows with side hung shutters of glazed or fly proofing including projecting type hinges with steel handle and steel peg stay, complete with out glazing bars, dovetailed or welded complete all as specified and directed.
S&F (factory made) steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel complete all as specified and directed.
M&L Mild steel work framed such as grills,gratings etc. with ends of bars souldered and or rivetted or forged into spikes,framed guard bars, frame work of water tanks and similar work conforming to Fe-290 (Gd-E-165) complete all as specified and directed.
S&F in repairs Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apperture 1.40 mm and with stainless steel wire staples complete all as specified.
M&L 3mm thick sheet glass ordinary quality and glazing with oil putty in square nexc. 0.5 sqm in each pane complete all as specified.
Same all as Item Srl No 39 above but frosted glass at one side.
S&F 100 mm long stainless steel but hings medium weight complete.
S&F 75 mm long stainless steel but hings medium weight complete.
S & F 150 mm long extruded aluminium alloy handles, fabricated type anodized complete
S & F 100mm aluminium handles, cast type, anodised complete all as specified and as directed by the Engineer-in-Charge.
S & F 200mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge
S & F 100mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S/F 300 mm long aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified.
S & F M S 300 mm ordinary rat tail rod pattern springs including roller and roller plate complete.
S&F floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring with rubber shoe over all length as cover plate 150 mm complete as in repairs.
S&F mild steel small articles as in hold fasts, bands, supports, straps etc complete all as specified and directed. Note : The hold fasts shall be treated with 2 coats of black bituminous paint & cost of the same will be included in the above quoted rate.
M&L for Preparing surface of wood and wood based materials new or old of any description and girth not otherwise described and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified.
M&L preparation of new steel surfaces of any description and apply two coat of synthetic enamel paint over a coat of red oxide not other wise described over 10 cm width or girth over steel surfaces surfaces.
S&F in repairs water closet vitreous China (squatting pan) complete including provision of lime concrete bedding vitreous china squatting pan orrisa pattern of size 580 x 440 mm, white, with CI 100mm bore P or S trap front or back inlet and foot rest any pattern excluding flushing cistern complete all as specified and directed.
S&F in repairs 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified.
S&F in repairs vitreous China Wash Hand Basin, white, flat back size 550×400 mm including cutting for and pinning in ends of brackets including brackets but exclusive taps,waste, chain and leg porcelain stop pan complete all as specified.
S&F in repairs 15mm bore, pillar taps, fany type chromium plated, cast copper alloy, with capston heads, scewed down high pressure, with or without lettered 'hot' or Cold' with long screwed shanks and flynuts, screwed for iron pipe complete all as specified.
S&F in repairs 15mm bore Bib tap standard of cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe and fixed complete all as specified. (Minimum weight 15mm - 90gms/ 20mm- 125gms).
S&F in repairs 15mm bore, angle/stop cock, fancy type, chromium plated,cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified.
S&F grating fixed in repair 100mm dia complete all as specified and directed.
S&F in repairs 15mm size PVC connection with PTMT nuts of length 600 mm.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints complete all as specified.
S&F in repairs 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints complete all as specified.
S & F 75 mm dia, PVC bend complete all as specified and directed.
S&F 110mm dia PVC bend with access door complete all as specified and directed.
S&F 110mm bore PVC junction single 'T' equal with provided access door complete al as specified and directed.
S&F PVC 75mm dia (SWR) branch piece single (Single Y) equal or unequal complete all as specified and directed.
S&F PVC 110mm dia (SWR) branch piece single (Single Y) equal or unequal complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed.
S&F in repairs UPVC waste pipes in any length with or without ears with cement joints fixed to alls 100 mm dia complete all as specified and directed.
S&F in repairs UPVC waste pipes in any length with or without ears with cement joints fixed to alls 75 mm dia complete all as specified and directed.
S&F in repairs 50mm bore High density poythelyne (HDPE) pipes of pressure rating 6kgf/ sq/ m in waste pipe for WHB and sinks,complete all as specified and as directed.
S&F in repairs waste coupling/fitting brass chromium plated for steel sinks,basins etc. with long screwed shanks and fly nuts,flange and bedded in red head cement and other end fixed of bore 32/40 mm.
M&L 75 mm dia PVC (SWR) floor trap with CP grating including jointing with solvent cement.
Taking down 20 mm dia steel tubing and connections, including cleaning for refixing or removal to store.
M&L for 20 mm dia tubes, 'medium grade', galvanised, with all fitting; fixed to wall, laid in trenches incl necessary cutting chasing pinning and making surface good all as directed.
Taking down 15 mm dia steel tubing and connections, including cleaning for refixing or removal to store.
M&L for 15 mm dia tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including necessary cutting, chasing, pinning and making surface good as directed.
Dismantling existing water storage tanks exc 500 and n exc. 1000 liters capacity & removing from site complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks of 1000 ltr capacity double layers (cylindrical vertical with closed top) white colour hoisted and fixed in position complete all as specified and directed.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long as in repairs.
S&F in repairs Soap dish vitreous China white, approximate size 160 x 160 x 90mm.
S&F in repairs tubular towel rail brass chromium plated , 20mm dia, 60cm long between flanges in repairs
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in Sub base of floor complete all as specified and directed.
M&L for 60mm thick rubber mould reflective factory made coloured pre cast PCC interlocking paver blocks/ tiles confirming to IS 15658-2006, M-35 designation of section as approved by GE in hard standing, laid dry over & including 50mm thick sand cushion and filling the voids of paver blocks/tiles with dry sand complete all as specified & directed. Make :- Mehtab Tiles, Indore (MP) or Nitco, Mumbai or Mayur Tiles & Interlocking pavers, Lucknow or Star Tiles & Industries, Ramadevi, Kanpur as approved by GE.
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr deep for fundations, manholes, laying GI/CI pipes etc n.exc 10Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exce 25 cm thick complete all as specified and directed.
Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Cutting existing cast iron pipes in any position for insert of new pipe/tees, branches etc complete all as specified as following size. Note : If required necessary excavation earth work, returning filling and removal of surplus soil shall be measured and paid separately under relevant item here-in-above.
250 mm bore.
200 mm bore.
150 mm bore.
100 mm bore.
Taking up the DI water mains (including all fittings) of size 150 mm dai incuding flanged ends rubber joints with spigot and socket ends and lead joint including burning out joints and recovering lead of size. Note : Excavation/earth work shall be measured and paid separately under relevant items here-in-before.
S&F Ducitile iron pipe double flanged ISI marked 150 mm Daimeter,3- 6 mtr length in Each pipe, 4 mm thickness, finished polished in round shape for drinking water all as specidied and directed by Engr-in-Charge, Location : Mandir line & church line.
M&L for run lead joints for the following size of pipes complete for water mains with spigot & socket pipes and fittings complete all as specified and directed :-
250 mm bore.
200 mm bore.
150 mm bore.
100 mm bore.
80 mm bore.
S&F the following rubber tyton joint of size:-
250 mm bore.
200 mm bore.
150 mm bore.
100 mm bore.
80 mm bore.
S&F rubber gasket joint for flanged end pipe & fittings of following size :-
250 mm bore.
200 mm bore.
150 mm bore.
100 mm bore.
80 mm bore.
S&F in repairs mechanical Gypsum joint ISI marked for spigot end pipe of following sizes :-
250 mm bore.
200 mm bore.
150 mm bore.
100 mm bore.
80 mm bore.
S&F 200/250mm bore spigot/flanged/ socketed CI fittings such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc complete all as specified.
Dismantling/taking out unserviceable sluice valve of size 80mm to 250mm bore dia by opening/cutting rusted nuts, bolts etc all as specified and directed.
S&F the following CI sluice valves both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed. Makee : Kirloskar/L&T/Upadhiya
80 mm bore.
100 mm bore.
S&F the following CI sluice valves both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed. Make : Kirloskar/L&T/Upadhiya
150 mm bore.
200 mm bore.
250 mm bore.
Dismantling/taking out unserviceable air release valve/non return/foot valve/fire hydant valve of any size by opening/cutting rusted nuts, bolts etc all as specified and directed.
Supply and fix CI double end flanged and drilled non return valve of size 200 mm PN-1.6 dia ISI Marked. Make : Kirloskar/Upadhyay/L&T
Supply and fix CI double end flanged and drilled non return valve of size 150 mm dia PN-1.6 ISI Marked. Make : Kirloskar/Upadhyay/L&T
Supply and fix CI double end flanged and drilled non return valve of size 100 mm dia PN-1.6 ISI Marked. Make : Kirloskar/Upadhyay/L&T
Supply and fix CI foot valve, flanged end and drilled of size 150 mm dia ISI Marked. Make : Kirloskar/Upadhyay/L&T
Supply and fix CI foot valve, flanged end and drilled of size 100 mm dia ISI Marked. Make : Kirloskar/Upadhyay/L&T
Supply and fix cast iron double ball air release valves of size 80mm as per IS 14845, PN rating H-7 ISI marked. Make : Kirloskar/Upadhyay/L&T
Cutting of road /hard standing for laying /dismentling of pipe line and making good surfaces matching with the existing surface after laying of pipe line.up to 30 cm.
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification:- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1200 x 1200x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mm x 40mm x 5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing.
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification:- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 900 x 900 x 1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing.
Taking up or down the following old unserviceable GI Tubing and connections including cleaning for refixing. Note :- Excavation/earthwork shall be measured & paid separately under relevant items here-in- before.
15 mm bore.
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
80 mm bore.
100mm bor.e
Refixing the following old GI Tubing and connections in New or old position (walls, Ceiling, Floors etc) of sizes:-
15 mm bore.
20 mm bore.
25 mm bore.
40 mm bore.
Laying only the followiing old serviceable removed GI Tubing from site and connection in New or old position (in trenches) of sizes :-
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
S&F the followiing GI tubing medium grade with all fittings and fixed complete laid in trenches of size :-
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
80 mm bore.
100mm bore.
S&F the followiing GI tubing medium grade with all fittings complete to walls and ceilings or laid in floors of size :
15 mm bore.
20 mm bore.
25 mm bore.
40 mm bore.
Taking down/removing the following Unserviceable Gate valve/stop valve from water supply lines, closing the opening with plug or preparing for new as required necessary fittings complete all as specified.
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
S&F the followiing Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete :- Make : Kartar/Zolto/Sant/Leader
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
Taking down/removing unservieable bib taps 15/20mm bore from pipe line/tanks complete all as specified and directed.
S&F 15mm bore bib tap cast copper alloywith crutch/buterfly handle screwed for iron pipe complete all as specified. Make - Prayag/Polytuff.
S&F 15mm bore bib tap standard of PTMT any colour (minimum wt 15mm - 90gms) screwed for iron pipe complete all as specified. Make - Prayag/Polytuff.
Cutting the following existing galvanised iron pipe in position for insertion of new pipe/tees, branches etc.
15 mm bore.
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
80 mm bore.
100 mm bore.
S&F in replacement the following stainless steel spindle suitable for following dia of sluice valve complete with stainless steel nut and threading as per sample & directed by engr-in-Charge.
250 mm bore sluice valve.
200 mm bore sluice valve.
150 mm bore sluice valve.
100 mm bore sluice valve.
80 mm bore sluice valve.
S&F in replacement Digital water leval indicator system 150 mm size digit direct display, operated on 230v Ac, suitable for upto 20 metre height over head Reservior/underground sump of any capacity, preadjustable alarm for upper & lower level, temp range - 5 to 50 degree, humidity up to 90% RH, reset push switch for silent the alarm including 4 core 1.5 sqmm copper cable. Make: SURYA ELECTRONICS & CONTROLS / RECTRONIC DEVICE & CONTROLS. Location : HQ CMM OH Tank & Mandir line OH Tank.
Taking up Submersible Pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 17.5HP/15 HP Pump Set. (i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3 phase, taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in-Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 17.5/15 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer, assembling the pump and motor including testing complete all as specified and directed.
Taking up Submersible Pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 12.5/10 HP Pump Set .(i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3 Phase ,taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn,providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 12.5/10 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer,assembling the pump and motor including testing complete all as specified and directed.
Taking up Submersible Pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 7.5/5 HP Pump Set. (i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3 Phase, taking out burnt winding wire,with & including pre insulated water proof copper wire with using winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 7.5/5 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer, assembling the pump and motor including testing complete all as specified and directed.
Note for item Srl No 123 to 125 above. (i) Cost of disconnection of electric connection from LT control panel & starter of submersible pumping set & reconnecting with existing pipe and making electrical connection with panel board & starter shall be included in the quoted rate of these items. (ii) Cost of lowering of submersible pump set of any size after repairs and re-connecting with existing pipe shall be included in the quoted rate of these items. (iii) Cost of spare parts shall be included in the quoted rate of these items. (iv) The contractor shall be repair the submersible pump and motor within 72 hours after receiving the complaint failing which recovery/penalty shall be imposed @ Rs 500.00/day. The same shall be recovered from the RAR/FB.
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Vlots, 50 Cycles, and taking out to local workshop induction motor 60/50/40 HP for repair purpose including complete cleaning,varnishing ,insulation and greasing and including shifting back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note - Rewinding will be measure & paid seperately under relavant item of schedule.
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Vlots, 50 Cycles, and taking out to local workshop induction motor 12.5/15/25 HP for repair purpose including complete cleaning,varnishing, reinsulation and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note :- Rewinding will be measure & paid seperately under relavant item of schedule.
M&L for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed by Engr-in-Charge. Make : Atlas/BWC/ Swastik/ Chetak
Taking down unservicable existing motor starter of any size/capacity.
M&L Fully Automatic Star Delta Motor starter 50 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 28-42 complete all as specified. Make : L&T cat No SS 91730 or Equivalent of SIEMENS/Schneider.
M&L Fully Automatic Star Delta Motor starter 35 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 22-32 complete all as specified. Make : L&T cat No SS 91730 or Equivalent of SIEMENS/Schneider.
M&L Fully Automatic Star Delta Motor starter 25 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 13-21 complete all as specified. Make : L&T cat No SS 91855 or Equivalent of SIEMENS/Schneider.
M&L Fully Automatic Star Delta Motor starter 15 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 11-18 complete all as specified. Make : L&T cat No SS 96257 or Equivalent of SIEMENS/Schneider.
M&L Fully Automatic Star Delta Motor starter 12.5 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 9-14 complete all as specified. Make : L&T cat No SS 96257 or Equivalent of SIEMENS/Schneider.
M&L Fully Automatic DOL Motor starter 7.5 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 13-22 complete all as specified. Make : L&T cat No SS 96228 or Equivalent of SIEMENS/Schneider.
M&L Fully Automatic DOL Motor starter 3 HP in sheet-steel enclosure type MF-1. feature (Motor Rating AC-1 Duty, 230V, 50Hz, 1-Ph) and Relay Range 10.5-17.5. Make : L&T cat No cs90319kodo or Equivalent of SIEMENS/Schneider.
Taking down unservicable existing cable from motor/pannel to starter any size/capacity.
S & F PVC Insulated unsheathed cable 10 sq mm, 3 core, multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Policab/Havells/Finolex
S&F in repairs MCCB 250 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : L&T / Schneider/Hager
S&F in repairs MCCB 200 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : L&T / Schneider/Hager
S&F in repairs MCCB 160 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : L&T / Schneider/Hager
S&F in repairs MCCB 125 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : L&T / Schneider/Hager
S&F in repairs MCCB 100 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : L&T / Schneider/Hager
S&F in repairs MCCB 63 A 16 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : L&T / Schneider/Hager
M&L draining water from OH reservoirs not exc. 18 Mtr head/staging, and cleaning internal portion of tank (bottom and walls) by means coir / wire brush etc. and wash the internal portion of tanks by using bleaching powder @ 25 grams per 1000 Ltrs of water after removing sludge and mud etc to a distance not exc 50 mtr including one coat of synthetic enamel paint on all steel surfaces such as ladder, railing, inlet & over flow CI pipes connected sluice valves of the respective OH tanks/ground level reservoir etc writing letters with white paint (date of cleaning and capcity of tank) on black painted surface of tanks all as directed by Engineer-in-Charge.
100000 gallons capcity.
50000 gallons capcity.
All as per item Srl No 145 above but exceeding 18 Mtr head / staging for the following :-
100000 gallons capcity.
All as per item Srl No 145 above but semi underground reservoir/sump of 200000 gallons cap each tanks devided in two poriton
All as per item Srl No 145 above but semi underground reservoir/sump of 100000 gallons cap each tanks devided in two poriton
All as per item Srl No 145 abovebut semi underground reservoir/sump of 50000 gallons cap each tanks devided in two poriton
All as per item Srl No 145 abovebut semi underground reservoir/sump of 25000 gallons cap each tanks devided in two poriton
Supply instll commissining and testing in repairs of CPRI Approved floor mounted outdoor cubicl type LT Feeder Pillar Box of uitabl size abricated out of 3.15 mm thick CRCA Sheet and angle iron 50 x 50 x 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrngement on front and back with locking arrangement cable entry and exist from bottom with cble glands and gaskets, Copper bus bar 750 Amps rating fixed on porcelain insulator with inernal wiiring with suitable size of Copper strips to be used for incoming and outgoing connection of all switchs/MCCB"s & Bus-bar, Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surfce externally & internally over a coat of red oxide primer paint incl, necessary PCC (1:3:6) type C2 as in fjoundation all as directed, comprising of the following :-
(a) INCOMING
(i) Thermal magnetic and microprocessor release MCCB 500 Amps, 4 Pole, 45 KA with front operated locking device - 01 Nos
(b) OUTGOING
Supply install commissioning and testing CPRI Approved floor mounted outdoor cubical type LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA sheet and angle iron 50 x 50 x 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, copper bus bar 450 Amps rating fixed on percelain insulator with internal wiring with suitable size of a copper strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surfce externally & internally over a coat of red oxide primer paint incl, necessary PCC (1:3:6) type C2 as in fjoundation all as directed, comprising of the following :-
(a) INCOMING
(i) Thermal magnetic and microprocessor release MCCB 300 Amps, 4 Pole, 45 KA with front operated locking device - 01 Nos
(b) OUTGOING
S&F in repairs15 HP submersible pump set suitable for 150-200 mm boreing, 1-447 mtr head, 30-740 LPM discharge, including all accessories all as specified and directed by Engr-in-Charge. Make KIRLOSKAR 15 HP BOREWELL SUBMERSIBLE PUMP SET 100HHN-1515 or CROMPTON 15HP BOREWELL SUBMERSIBLE PUMP 8W3K15D-W or Havells Submersible Pumpsets Water Filled Motor H6W6M3F150T 11.2 kW 15 HP.
S&F in repairs10 HP submersible pump set suitable for 150 mm boreing, 5-306 mtr head, 60-2400 LPM discharge, including all accessories all as specified and directed by Engr-in-Charge. Make KIRLOSKAR 10 HP BOREWELL SUBMERSIBLE PUMP SET KS6F-1006R orCROMPTON 10 HP SUBMERSIBLE PUMP SET 650CS100-1010 or Havells Submersible Pumpsets Water Filled Motor 7.5 kW 10 HP.
S&F in repair centrifugal pump 1 HP, single phase, 9-22 mtr head, brass impeller, with complete accessories all as specified and directed by Engr-in-Charge. Make CROMPTON 1 HP MBG12 CENTRIFUGAL WATER PUMP or KIRLOSKAR 1 HP 210V 0.75 KW SINGLE PHASE MONOBLOCK PUMPS KDS-128+ or V-GUARD MONOBLOCK PUMP NEON-WSF100
Note :- Item No 148, 149 & 150 catered against BER items
Schedule of credit amount of Rs. 2,36,703.00 to be deducted during AOC
shri krishna traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .