Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC The lowest e-tenderer | |
| 2 | L2₹31.0 L+₹5.0 L (19.2%)Rejected-Finance | L2 | Rejected-Finance Not Meeting eligibility criteria | |
| 3 | L3₹31.1 L+₹5.0 L (19.4%)Rejected-Finance | L3 | Rejected-Finance Not Meeting eligibility criteria | |
| 4 | L4₹36.2 L+₹10.1 L (38.8%)Rejected-Finance NAGPADA MUMBAI 10TH LANE KAMATHIPURA S P ROAD TELANG BLDG NO 23 ROOM NO 5 10TH LANE MUMBAI 400008 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | L4 | Rejected-Finance Not Meeting eligibility criteria |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri T Rajasekharam, IDSE, SE (SAG)
Headquarters Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
REPAIR MAINTENANCE OF HT SWITCH GEARS RELAY CABLES AND REPLACEMENT OF CERTAIN CONNECTED ITEMS AT ARMY AREA UNDER GE WEST COLABA
2024_MES_646420_1
85111/W/E8
Open Tender
Civil Works
Item Rate
180 days
Garrion Engineer West Colaba
Please ref tender documents
7 documents required · 7 mandatory
₹500
Garrison Engineer (W) Colaba
₹80,000
3 Jun 2024
14 Mar 2024
11 Apr 2024
14 Mar 2024
10 Apr 2024
29 Mar 2024
14 Mar 2024 - 3 Apr 2024
Amount
M&L for Dy hydration/fltration of Transformer oil including testing of dielectric strength of transformer oil of indoor type transformer, 11KV/433 volt, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete as specified. (Note: Transformer oil will be measured & paid seperately.)
M& L for Removing old burnt Transformer oil and Supply and toping of transformer oil with 50KV di-electric strength complete all as specified.
Supply and fixing of hydrogenated nitrile transformer oil seal, with maximum di electric strength duely tightened with bushings complete to avoid leakage from transformer bushings of various transformer installed at variuos locations under Colaba area all as specified and directed .
M & L for spray painting to indoor/outdoor type, step up/step down transformer installed at different location of Colaba area after scraping throughly the existing corroded paint/rust, filing of cavaties and applying two coats of heat resistant paint of approved quality of required colour and writing the details such as SM/MES No. etc.of capacity 100KVA/160 KVA/ 200KVA/315 KVAall as per specified and directed by Engr - in - Charge .
M & L for spray painting to indoor/outdoor type, step up/step down transformer installed at different location of Colaba area after scraping throughly the existing corroded paint/rust, filing of cavaties and applying two coats of heat resistant paint of approved quality of required colour and writing the details such as SM/MES No. etc.of capacity 400KVA/500KVA /630KVA/ 800 KVA all as per specified and directed by Engr - in - Charge .
Dismantling of Damaged Breather and Supply and fixing in repair of breather with 500 Grams celica gel of indoor type transformer 200KVA/300KVA/400/500 KVA, all as specified and directed by Engineer-in-Charge.
Dismantling of Damaged thermometer and Supply and fixing in repair of thermometer(oil temperature gauge) for indoor type transformer, all as specified and directed by Engineer -in -Charge.
Material and labour for Servicing/Repairing of Transformer by disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for removal of sediments,carbon deposits at bottom of transformer tank, on core,on winding etc cleaning with new transformer oil including cleaning of oil tank and attending leakage problem with oil seal and all gaskets and re assembling complete of capacity Transformer 400KVA to 800KVA ,11KV/433Volt all as specified and directed. (Note : New Transformer oil and spare parts will be measured and paid separatley excluding oil seal)
Material and labour for Servicing/Repairing of Transformer by disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for removal of sediments,carbon deposits at bottom of transformer tank, on core,on winding etc cleaning with new transformer oil including cleaning of oil tank and attending leakage problem with oil seal and all gaskets and re assembling complete of capacity Transformer 160KVA to 315KVA ,11KV/433Volt all as specified and directed. (Note : New Transformer oil and spare parts will be measured and paid separatley excluding oil seal)
Material and labour for Servicing/Repairing of Transformer by disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for removal of sediments,carbon deposits at bottom of transformer tank, on core,on winding etc cleaning with new transformer oil including cleaning of oil tank and attending leakage problem with oil seal and all gaskets and re assembling complete of capacity Transformer 160/200KVA ,11KV/433Volt all as specified and directed. (Note : New Transformer oil and spare parts will be measured and paid separatley excluding oil seal)
Material and labour for loading into truck of faulty Transformer of capacity 250 KVA to 500 KVA with the help of Crain and shifting from site to factory premises and unloading complete all as specified and directed.
Material and labour for loading into truck of Transformer capacity 250KVA to 500KVA after carying out the repair with the help of Crain and shifting from factory premises to site and unloading and shifting it inside the sub station and connecting all HT and LT cable connections and earthing connections complete all as specified and directed.
Material and labour for Dismantling the Core and taking out along with windings, replacing faulty winding and cleaning oil tank of transformer 200 to 500KVA, 11KV/415Volts and removing sludges from tank, and all as per manufacturers specifications and standard practice complete all as specified and directed. (Note: Transformer Oil will be measured and paid seperately).
Material and labour for replacing Burnt out Studs and bushing with nuts of any material by providing new copper alloy stud with nut,washers and bushing on HV Side complete all as specified and directed for following capacity transformers:- (a) Transformer 500KVA/400KVA ,11KV/433Volt
Transformer 315KVA/200KVA/ 160 KVA ,11KV/433Volt
Material and labour for replacing Burnt out Studs and Bushing with nuts of any material by providing new copper alloy stud with nut,washers and bushing on LV Side complete all as specified and directed for following capacity transformers:- (a) Transformer 500KVA/400KVA ,11KV/433Volt
Transformer 315KVA/200KVA/ 160 KVA ,11KV/433Volt
Dismantlin of old damaged Cooling Fins and Supply and fix in repair cooling fins of transformer of capacity 160 KVA/ 200 KVA/ 315 KVA as per manufacturer's specifications and standard practice complete all as specified and directed.
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800 Amps from location and repair /overhauling and carrying out with the following activities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare parts will be measured & paid seperately.) (i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of tripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete.
Dismantling of Old Damaged/burnt spare parts from VCB and Supply and fixing in repair of following Spare parts suitable for - VCB 11 KV , 630/800 Amps indoor type all as specified and directed by Engineer-in-Charge. (a) Isolating Contacts flat type
Vaccum InterupterVG2
Insulating Rod
Closing coil 110V /24V DC
Tripping Coil 110V /24V DC
Spring Charging Motor 110V-230V AC/DC
Breaker Auxiliary Switch 6NO +6NC
Motor Cut-off switch
Main Drive Shaft assembly
Trip Fork Linkage Assembly
Rachet Wheel
Pin for Rachet
Handle Block Assembly
Closing coil assembly without coil
Trip coil assembly without coil
Motor cutt off Lever assembly
Trip Proper support assembly
Release lever
Pin for Release lever
Auxiary switch drive Assembly
Charging Pawl
Buffer for Spring
Over Rid Stop
Over Rid Stop Pin
24 Pin Plu and Socket Assembly
Bus Bar Spout Insulator with CC parts for R Phase
Bus Bar Spout Insulator with CCparts for Y Phase
Bus Bar Spout Insulator with CC parts for B Phase
Circuit Spout Insulator with CC Parts
3Phase Spout Insulator assembly Bus bar /Circuit side.
Half Collar (Pair)
Raising and lowering Handle
TNC Switch,16Amps Recom
Ammeter,digital type,DM3110 Schneider
Voltmeter,digital type DM3210 Schneider
Multifunction meter digital typeEM6400NG Schneider
Indicating Lamps24/110V DC LED type
Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts AC and replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts and oil will be measured and paid seperately)
Material and labour for painting of HT VCB capacity 250/350MVA,11KV, 400/630/800Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and in side surface of VCB and all as specified and as directed by Engineer-in-charge.
S&F, testing commissioning of current transformer 50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec for 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800 Amps, panel board complete all as directed and specified by Engineer-in-Charge.
T&P for Testing /Overhauling and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete.
Repair/Overhauling Indoor type, 11 KV, SF 6,RMU Panel and carrying with following and all as specified and directed by engineer in Charge. Note :- (i) Including fixing of spare parts to function RMU smoothly and rate to be included. Notes :- Spare parts and SF6 Gas will be measured and paid separatly. (i) Inspecting/overhauling of Manual/motorised spring drive mechanism by checking mechanism, Motor and gear assembly, Big gear assembly, stop bolt assembly, Main shaft interlocking assembly, closing spring assembly, Small Cam with screw, motor cut -off limit switch, Butter fly switch assembly and apply multi grease lubricant to function smoothly. (ii)Inspecting / overhauling of assembly, earth fault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii)Inspecting / overhauling /cleaning and inspecting insulators, Gas Chamber by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Inspecting of Gas SF6 leakage and Re filling SF6 gas as required and all as directed. (v) Overhauling/testing of Metering Panel with PT (vi) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete. (vii) Cleaning all busbar by rubbing and by CRC liquid cleaner. (viii)Spraying two coat of anti track paint on CTs. (ix) Applying insulating boots for busbar and cables. (x) Supply and fixing all missing nut bolts for panels.
S& F 11 KV, SF 6,RMU Panel Srping Charging Motor, with complete mechanisim 230/110/24 Volts of exiisting make.
S& F 11 KV, SF 6,RMU Panel SF 6 Gas filling up to the indication mark complete all as specified and as directed
S& F DC to DC Converter 110 V DC to 24 Volt dc 20 A (with range from 10A to 20A) with inbuilt short circuit protection supply for control circuit of 11 KV VCB/RMU complete all as specified and as directed
S& F battery SMF EP 100-12 (12V/100AH) complete all as specified and as directed
S& F battery rack and wiring complete all as specified and as directed
Supply, fixing in repair of Power Pack Unit 230 Volts, AC/30 Volts DC suitable consisting MF battery 30 Min power back up for Indoor type VCB, 11 KV, 800 Amps VCB Panel Board for auxiliary supply including necessary wiring and hard ware and all as directed.
Dismantling old burnt Heaters and Supply Fixing Space Heater 80 Watt capacity suitable for VCB,s /OCB' in existing panel including hard ware,wiring and all as directed.
T&P for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 50 sqmm to 95 sqmm all as specified.
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified.
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240 sqmm to 300 sqmm all as specified.
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified.
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240sqmm to 300 sqmm all as specified.
Supply,laying in trench, in duct on wall,and testing in replacement for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sq. mm X 3 core all as specified and as directed.
Supply,laying in trench, in duct on wall,and testing in replacement for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sq. mm X 3 core all as specified and as directed.
Supply and laying High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 110mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings all as specified and directed by Engineer-in-Charge.
T&P for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Material & labour for cable jointing kit, in repair, for LT 1.1 KV grade cable for straight through joint M-Seal type for underground PVC/XLPE armoured heavy duty cable aluminum conductor of size 3.5/4 core 50 Sqmm complete including testing & commissioning complete all as specified and directed.
All as per item No 7 herein before but cable 3.5 core 70 Sq mm
All as per item No 7 herein before but cable 3.5 core 95 Sq mm
All as per item No 7 herein before but cable 3.5 core 120 Sq mm
All as per item No 7 herein before but cable 3.5 core 185 Sq mm
All as per item No 7 herein before but cable 3.5 core 240 Sq mm
All as per item No 7 herein before but cable 3.5 core 300 Sq mm
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric panels by taking shut down from appropiate authority including T&P for Attending Faults/Trippings and rectifieng /repairing the faults in HT/LT Panels Boards/Capacitor Panels Boaeds/ MCCB's/ACB's /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. (i) Tightning the loose connections and cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting as pproved colour and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed . (Note : MCCB,ACB, measured and paid separately under relevant items of this schedule.)
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 240 Sqmm to 300Sqmm x 3.5 core complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 150Sqmm to 240Sqmm x 3.5 core complete all as specified and directed by Engr-in-charge.
M&L for Dismantling of Damaged APFC panel power contactor and Supply and fixing in repair power contactor 3 pole 32 Amp to 55 Amp (MNX 32) 240 Volts suitable for 5 KVAR capacitor to 20 KVAR Capacitor to automatically correct the power factor for indoor type transformer, Complete all as specified and directed by Engineer -in -Charge.
Dismantling of Damaged TP from APFC panel and Supply and fixing in repair TP 40 amp MCB 440 Volts suitable for 5 KVAR capacitor to 20 KVAR Capacitor to automatically correct the power factor for indoor type transformer, Complete all as specified and directed by Engineer -in -Charge.
Dismantling of Damaged APFC Power capacitor and Supply and fixing in repair heavy duty square type 5KVAr capacitor 440 Volts, 6.56 Amp Ir, 3 × 27.4 µF capacitor suitable 100 to 300 KVAR APFC panel to automatically correct the power factor for indoor type transformer, Complete all as specified and directed by Engineer -in -Charge.
Dismantling of Damaged APFC Power capacitor and Supply and fixing in repair heavy duty square type 10 KVAr capacitor 440 Volts, 13.12 Amp Ir, 3 × 54.8 µF capacitor suitable 100 to 300 KVAR APFC panel to automatically correct the power factor for indoor type transformer, Complete all as specified and directed by Engineer -in -Charge.
Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by Engineer-in-Charge.(Note : Spare parts will be measured and paid separately)
Dismantling of Old Damaged/burnt spare parts from ACB and Supply and fixing in repair of following Spare parts suitable for -ACB 415V , 630 to 1200Amps Amps indoor type all as specified and directed by Engineer-in-Charge. (a) Shunt Trip Device
Closing coil assembly
Mismatch Prevention Device
Moving contacts assembly
Fixed Contact assembly
Auxialary Switch
Arc chut with hardware
Current Transformers 630A/5A.
Current Transformers 800A/5A
Current Transformers 1200A/5A
Dismantling of old damaged halogen fitting Supply & fixing in repairs 500 watt Incandescent/ GLS lamp halogen Lamps with holder with aluminum cover 230Volts AC for substation heating to avoid moisture complete all as specified and directed.
S&F of Room Heater 1000 Watt coil type in substation to avoid moisture in HT installation room complete all as specified and directed by Engr-in-charge.
Dismantling of old damaged Lamps and Supply & fixing in repairs 200 watt Incandescent/ GLS lamp 230Volts AC for substation heating to avoid moisture complete all as specified and directed.
Cleaning the vegetation including glass, bushes small trees and all vegetation growth complete including digging out the root of bushes and small trees around the installation/sump/OH reservoir, valve chamber etc. filling the rough holes with earth and levelling the surfaces by removing all debris outside MD land complete all as specified and directed.
Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth lead strip 32 x 6 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No3 of MESschedule part-I, earth lead strip connected to indicated position including concrete pit in PCC(1:3:6, C1),Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as specified and as directed and testing on completion.
Manufacturing, supplying and fixing at various sub stations for SINGLE LINE DIAGRAM of HT Cable network farme board of size 600 mm x 900mm having fully covered by suitable plain glass as approved by GE . Letter ,symbols, MES Logo ,borders etc.on A-1 Size papaer all as required colour scheme in all respects as per direction of Engineer-in-charge.
Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out complete in soft/loose soil all as specified.
All as per sl. item No.115 above but in hard/dense soil.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assembly and laying of U/G cables etc. and getting out in soft disintegrated rocks/road cutting/RCC/PCC complete all as specified and directed.
Supply and providing sand/stone dust for sand cushioning for cable protection or filling in trenches of sand in cable ducts after cleaning of ducts all as directed and specified Note:. for the purpose of payment punned thickness will be measured.
Supply and providing unreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) of sizes Class HVP type I with peak, flat size 300x180x40 mm putting adjecent to each other as specified.
Returning,filling in soft/loose soil including spreading, levelling, watering ,well ramming in layers n.exc 25 cm complete all as specified.
Removing of excavated material not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point.in soft /loose soil
Removing of excavated material from the site of work and transporting out of MD land complete all as specified and directed.
M & L and fabrication work with Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specifeid and diredted by Engr-in-charge.
M/s Qureshi Construction Co
NOEL ENGINEERS
SHREE SHIV ELECTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .