Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.7 L+₹2.0 L (7.99%)Rejected-Finance 41 CUSTODIAN ANNEXE BEHIND WOOD LAND SCHOOL SHIVPORA SRINAGAR JAMMU KASHMIR 190004 | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance Being L2 |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
4 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE 134 Wks Engrs
HQ 134 Wks Engrs PIN-914134 c/o 56 APO
PROVISION OF HT DISTRIBUTION AT KHUNDRU UNDER GE 861 EWS
2020_MES_382508_1
134 WE-54/2020-21
Open Tender
Civil Works
Item Rate
180 days
Srinagar
PLEASE SEE TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE 861 EWS
₹49,000
Yes
18 Dec 2020
30 Sept 2020
6 Nov 2020
30 Sept 2020
4 Nov 2020
18 Oct 2020
60 days
Amount
Supply, installation, electrically connecting, testing and commissioning of 750 KVA voltage stabilizer for automatic and manual operation, three phase, suitable for unbalanced load and unbalanced supply, naturally oil cooled, outdoor type, copper wound and designed for input voltage between 8 to 11 KV, 3 phase 50 Hz and output voltage stabilizer at 11 KV with accuracy + 1% 3 phase 50 Hz and speed of correction 80V to 85V per second. Input/output voltage shown by digital voltmeter on front panel. Auto/ manual provision on front pannel with first fill of transformer oil and by pass arrangement in emergency case etc complete all as specified with the following technical specification :- (a) Capacity - 750 KVA (b) Input Voltage - 8 KV/11 KV 3 phase 50 Hz (c) Output Voltage - 11 KV +1% 3 phase 50 Hz (d) Type - Suitable for Balanced supply unbalanced load (e) Application - Completely Outdoor type (f) Standard - IS 2026/77 (g) Phase - 3 Phase, 3 wires (h) Frequency - 50 Hz (j) Response Time - Instantaneous (mili sec) (k) Speed of Correction - 80 v to 85 v/sec (l) Mode of operation - Automatic/ Manual/ Hand control (m) Suitability - Suitable for all power factors (n) Duty cycle - Continuous 24 Hrs at 100% load (o) Efficiency - More than 99% (p) Looses at No load - As per IS standard (q) Losses at Full load - As per IS standard (r) Cooling - ONAN (Oil Natural/ Air Natural) Transformer Oil - " A Grade" tested & Certified as per IS 335 Operating temperature - 00C - 450 C above ambient Laminations Used - Imported low loasses CRGO Laminations - M4 Grade Carbon Rollers Used - Imported High Grade Graphite Rollers Make : Andrew yule/ Servokon/ AE/Vinitec/Volina/Electric field
Supply, laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, HT electric power cable (heavy duty) with stranded aluminium conductor, 11000 volts (earthed system) grade cross sectional area 120 sqmm 3 core complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, HT electric power cable (heavy duty) with stranded aluminium conductor, 11000 volts (earthed system) grade cross sectional area 95 sqmm 3 core complete all as specified and directed by Engr-in-Charge.
Supply and fixing steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410-SP-55 ( 11mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified and derected by engir-in charge. (note- Excavation and PCC shall be measured and paid seperately )
Plain cement concrete (1: 2 : 4) type B-2 (using 40mm graded crushed stone aggregates) as in foundation for sub base of plateform/ pole etc complete all specified and directed by Engr-in-Charge.
Plain cement concrete (1: 4:8) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling or mass concrete etc including necessary form work for rough finished surfaces complete all specified and directed by Engr-in-Charge.
Plain cement concrete, (1:2:4), type B-1( using 20mm graded crushed stone aggregates) as in coping, benching including weathering, slightly rounded or chamfered on edges and throating including necessary form work complete all as specified and directed by Engr-in-Charge.
Supply and fixing cable jointing kit for 11KV (Earthed) grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 95 Sqm, complete all as specified and directed by Engr-in-Charge.
Supply and fixing cable jointing kit for 11KV (Earthed) grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out any type of soil for laying of cable, errection of pole, stays etc complete all as specified and directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and deapth exc 1.5m but n.exc 3 m and getting out any type of soil for laying of cable, errection of pole, stays etc complete all as specified and directed by Engineer-in-charge.
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed by Engineer -in-charge.
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level not exc 1.5 mtr above the ground level/starting point compalete all as specified and directed by Engineer -in-charge.
River sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after laying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured
Supply and laying un-reinforced precast concrete cable cover, class HVP, Type 2 with size 450 mm x 180 mm x 40 mm laid with width along the length of cable on sand cushioning complete all as specified and directed by Engr in Charge
M/ L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and convensional skull and bone in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 25cm x 20 cm size.
S&F in replacement of GOD triple pole 11000 Volts, mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 Amp with dropout fuse complete, all as specified and directed by Engineer-in-Charge.
Pin type, Porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade, complete all as specified and directed by Engr-in-Charge.
Aluminium conductor steel reinforced any size in over head lines on HT poles including stretcing the aluminium conductor and binding with binding wires of aluminium or aluminium tapes etc. Jumpers and connections complete all as specified and directed by Engr-in-Charge.
S & F in repairs Galvanaised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces incl taking down / dismantling the old items complete all as specified and directed by engr-in charge.
Earthing with copper earth plate electrode, 600mm x 600mm x 3.15mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to copper strip 25x3mm as earth lead by means of bolts, nuts and washers of GI after welding to full length of earth electrode and 32mm bore light grade GI protection pipe up to test point, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 and 40mm bore light grade GI protection pipe (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as specified and directed. Notes: (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metres length shall deem to be included in the unit rate quoted against this item. (ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for seperately under appropriate item of Sch A part-I. (iii) On testing after completion if desired resistanace is not obtained, the contrator shall redo the earthing without any extra cost to the department.
S&F and connecting GI strip 32x6mm, buried in ground or fixed to wall etc for loop earthing, complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing 1100 volt grade XLPE insulated heavy duty cable, 95 sqmm 3.5 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable etc complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
Supply, laying and testing 1100 volt grade XLPE insulated heavy duty cable, 120 sqmm 3.5 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable etc complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
S&F cable route indicator made out of 50X50X6mm angle iron , 60 mm long embedded in PCC block of suitable size with moulded letter "HT cable" suitable inscribed including PCC 1:3:6 type C2 (using 40 mm graded aggregate block of 150x150x150mm size complete all as specified and directed by Engr-in-Charge.
Lightening arrestors expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amps suitable for 11000 volts (11KV) confirming to IS -3070 , complete all as required at site or as directed by Engr-in-Charge.
Anti climbing device, spike type fabricated out of MS bar (round, flat or square) including nuts, bolts and washers and welding into two halves made to shape to suit the cross section of pole including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Razdan Builders and Suppliers
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .